Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
World J Surg Oncol ; 21(1): 354, 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37978382

RESUMO

PURPOSE: The purpose of this study was to investigate the use of thromboelastography (TEG) in patients with colorectal cancer and to examine whether the TEG parameters can be used as potential markers for disease screening and prediction of disease severity. METHODS: One-hundred fifteen healthy controls (HC), 43 patients with benign adenoma (BA), and 387 patients with colorectal cancers (CRC) were included in the study. TEG parameters (reaction time, R; clot kinetics, K; alpha angle, α-angle; maximum amplitude, MA), conventional laboratory parameters, and clinical information were collected and analyzed among the HC, BA, and CRC groups. Receiver operating characteristics (ROC) were used for differential analysis. The correlation between TEG parameters and pathological information of CRC (differentiation degree, vaso-nerve infiltration, TNM stage) was analyzed. The differences in TEG parameters at different stages of disease and pre-/post operation were compared. RESULTS: Shorter K and higher α-angle/MA were found in patients with CRC compared with HC and BA (P < 0.001). TEG parameters demonstrated moderate diagnostic value (distinguish CRC from HC + BA: K-AUC = 0.693, α-angle-AUC = 0.687, MA-AUC = 0.700) in CRC but did not outperform traditional laboratory parameters. TEG hypercoagulability was closely associated with tumor markers (carcinoma embryonic antigen and carbohydrate antigen 19-9) and pathological information (differentiation degree, vaso-nerve infiltration, and TNM stage) (P < 0.05). Trend analysis showed that K decreased, but α-angle/MA increased gradually as the tumor progressed (P < 0.001). K- and α-angle showed slightly better sensitivity in predicting advanced tumors compared to traditional laboratory parameters. In CRC patients, 3-6 months after tumor resection, K [from 1.8 (1.5, 2.3) to 1.9 (1.6, 2.6)], α-angle [from 65.3 (59.0, 68.6) to 63.7 (56.6, 68.5)], and MA [from 61.0 (58.2, 66.0) to 58.9 (55.8, 61.3)] exhibited modest improvements compared to their preoperative values (P < 0.05). CONCLUSION: TEG parameters possess moderate diagnostic value in CRC diagnosis and predicting advanced tumors, and they are closely linked to surgical interventions. Although TEG parameters do not significantly outperform traditional laboratory parameters, they still hold promise as potential alternative indicators in CRC patients.


Assuntos
Neoplasias Colorretais , Tromboelastografia , Humanos , Curva ROC , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/cirurgia
2.
J Diabetes Complications ; 36(8): 108236, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35773172

RESUMO

AIMS: The purpose of this research was to explore the association of TEG parameters (Reaction time, R; Clot kinetics, K; Alpha angle, α-angle; Maximum amplitude, MA) with vascular complications of type 2 diabetes mellitus (T2DM), and assess whether TEG parameters could predict T2DM patients with vascular complications. METHODS: A total of 68 healthy controls (HC), 57 T2DM patients without vascular complications (NC), 18 T2DM patients with only microvascular complications (MIC), 196 T2DM patients with only macrovascular complications (MAC), and 94 T2DM patients with both microvascular and macrovascular complications (MIC+MAC) were recruited in this study. Participants' clinical information and TEG parameters were recorded. TEG parameters were analyzed by the Jonckheere-Terpstra trend test, assuming the vascular complication was progressing from HC â†’ NC â†’ MIC → MIC+MAC or HC â†’ NC â†’ MAC â†’ MIC+MAC. Receiver operating characteristic (ROC) was performed to explore the diagnostic accuracy of TEG parameters in T2DM with vascular complications. RESULTS: Shorter TEGK, higher TEG-α-angle, and higher TEG-MA were found in T2DM patients with both microvascular and macrovascular complications (MIC+MAC) group compared with healthy controls (HC) group and T2DM patients without vascular complications (NC) group (P < 0.05). Trend analysis showed that TEG-R/K decreased, but TEG-α-angle/MA increased gradually as the vascular complication progressed (P < 0.001). With stratification of urine microalbumin/creatinine ratio (UACR), diabetic nephropathy with macroalbuminuria (grade A3) behaves shorter TEGK, higher TEG-α-angle/MA compared with normal to mildly increased albuminuria (grade A1) and microalbuminuria (grade A2) (P < 0.05). ROC curves implied that TEGK, TEG-α-angle, and TEG-MA have moderate diagnostic values in T2DM without vascular complications (K-AUC: 0.780, α-angle-AUC: 0.773, and MA-AUC: 0.740) as well as T2DM with both microvascular and macrovascular complications (K-AUC: 0.778, α-angle-AUC: 0.757, and MA-AUC: 0.800). CONCLUSION: TEG parameters are associated with the progression of vascular complications in T2DM, and it could be a diagnostic indicator for T2DM without vascular complications or with advanced vascular complications.


Assuntos
Doenças Cardiovasculares , Diabetes Mellitus Tipo 2 , Diabetes Mellitus Tipo 2/complicações , Humanos , Curva ROC , Tromboelastografia
3.
Zhonghua Yi Xue Yi Chuan Xue Za Zhi ; 30(4): 473-6, 2013 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-23926019

RESUMO

OBJECTIVE: To study a family with Bw subtype of ABO blood group system, and to review safety issues in relation with clinical transfusion. METHODS: The molecular basis for the blood type was studied with serological assay, polymerase chain reaction-sequence specific primer (PCR-SSP) and DNA sequencing, TA clone and haplotype analysis in one blood donor whose ABO blood group were difficulty typed and her family. The bioinformatics analysis was carried out by biological analysis software to investigate the change of structure and function of enzymes influenced by the change amino acid. A retrospective survey was carried out to investigate what is the actual position that the donor blood was used in the clinical transfusion. RESULTS: Three members from the family were found to have a Bw subtype. A substitution of nucleotide C by T at position 721 in exon 7 was discovered, which resulted in replacement of amino acid Arg to Trp. Review of clinical record suggested that there has been no significant abnormality association with past three blood transfusions. CONCLUSION: A 721C>T mutation of the ABO gene probably underlies the Bw subtype. Further research is needed for understanding the clinical significance of this subtype in the blood transfusion.


Assuntos
Sistema ABO de Grupos Sanguíneos/genética , Sistema ABO de Grupos Sanguíneos/classificação , Adulto , Sequência de Aminoácidos , Sequência de Bases , Transfusão de Sangue , Éxons , Feminino , Humanos , Masculino , Dados de Sequência Molecular , Linhagem , Reação em Cadeia da Polimerase , Estudos Retrospectivos
4.
Zhongguo Shi Yan Xue Ye Xue Za Zhi ; 15(4): 888-91, 2007 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-17708827

RESUMO

The purpose of this study was to explore the clinical value of the platelet antibody screening and typing in platelets transfusion by using microcolumn gel immunoassay (MGIA). The platelets antigen-antibody reactions including the antibody screen and blood crossmatch were detected by MGIA. The results indicated that the detection of platelet antibody showed positive in 30 cases of aplastic anemia (AA), 11 cases of myelodysplastic syndrome (MDS), 24 out of 25 cases of leukemia and 1 out of cases of other diseases, while detection of platelet antibody showed negative in 20 normal volunteer donors. The number of platelet antibody crossmatch coincidence in 112 specimens of AA, 42 specimens of MDS and 95 specimens of leukemia were 45, 20 and 40, the coincidence rates were 40.18%, 47.62% and 42.11%. The mean corrected count increment (CCI) in 20 patients received platelet transfusion many times was 18.2 after crossmatch and 4.7 before crossmatch. It is concluded that the positive rate of platelet antibody screening is very high in patients with hematologic malignancies, the coincidence rate of platelet antibody crossmatch in 249 blood samples is between 40% and 48%, and the efficiency of using crossmatched platelets in clinic is enhanced significantly.


Assuntos
Antígenos de Plaquetas Humanas/imunologia , Tipagem e Reações Cruzadas Sanguíneas , Plaquetas/imunologia , Isoanticorpos/sangue , Anemia Aplástica/imunologia , Neoplasias Hematológicas/imunologia , Humanos , Imunoensaio/métodos , Isoanticorpos/imunologia , Transfusão de Plaquetas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...