Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Lab Hematol ; 46(3): 538-545, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38303489

RESUMO

INTRODUCTION: Dilute Russell's viper venom time (dRVVT) and activated partial thromboplastin time (APTT) are the mainstay assays in lupus anticoagulant (LA) detection yet they have limitations, particularly in relation to interferences and specificity. The recently validated Taipan snake venom time (TSVT) screening with ecarin time (ET) confirmatory assays overcome many of those limitations due to the innate specificity engendered from direct prothrombin activation, and insensitivity to the effects of vitamin K antagonists (VKA). The present study aimed to further evidence diagnostic utility of TSVT/ET by performing them in samples from 116 nonanticoagulated patients with established triple-positive antiphospholipid syndrome (APS). METHODS: Samples were identified in three expert centres who performed dRVVT, APTT and solid phase antiphospholipid antibody assays with reagents from a variety of manufacturers. All samples additionally received TSVT/ET analysis using standardised reagents. RESULTS: Ninety seven of 116 (83.6%) were dRVVT- and APTT-positive, 85/97 (87.6%) of which were TSVT/ET-positive, 9/116 (7.8%) were dRVVT-positive only, 6 of which were TSVT/ET-positive, and 10/116 (8.6%) were APTT-positive only, 5 of which were TSVT/ET-positive. 96/116 TSVT/ET-positivity returned a high sensitivity for LA of 82.8%. Low coefficients of determination revealed weak relationships between LA potency and anticardiolipin and anti-ß2-glycoprotein I antibody titres for all three LA assays. CONCLUSIONS: TSVT/ET has high sensitivity for the clinically significant LA found in triple positive APS patients. TSVT/ET can establish multiple LA assay positivity in nonanticoagulated patients negative for one of dRVVT or APTT, and is the only assay pairing insensitive to VKAs, the recommended anticoagulation for APS.


Assuntos
Síndrome Antifosfolipídica , Inibidor de Coagulação do Lúpus , Humanos , Síndrome Antifosfolipídica/sangue , Síndrome Antifosfolipídica/tratamento farmacológico , Síndrome Antifosfolipídica/diagnóstico , Inibidor de Coagulação do Lúpus/sangue , Feminino , Masculino , Tempo de Tromboplastina Parcial , Sensibilidade e Especificidade , Pessoa de Meia-Idade , Adulto , Animais , Daboia , Testes de Coagulação Sanguínea/métodos , Testes de Coagulação Sanguínea/normas , Idoso
2.
J Thromb Haemost ; 21(12): 3539-3546, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37597725

RESUMO

BACKGROUND: Triple positivity for all 3 criteria antiphospholipid antibodies confers high risk of symptom development in carriers, and recurrence in antiphospholipid syndrome (APS). Most triple-positivity studies report lupus anticoagulant (LA) testing as positive without distinguishing between positivity with dilute Russell's viper venom time (dRVVT) and activated partial thromboplastin time (APTT) and single-assay positivity or only perform dRVVT. Single LA assay repertoires remain in use in some centers, which risks missing some triple positives. Positivity with both assays may identify higher risk. OBJECTIVES: The aim of this study is to investigate the frequency of single LA assay positivity in triple-positive patients. METHODS: Three hundred forty-two triple-positive profiles from nonanticoagulated patients (237 APS, 45 systemic lupus erythematosus without APS symptoms, and 60 nonclinical criteria) were identified from laboratory databases and assessed for LA positivity by dRVVT and/or APTT. RESULTS: Seventy-three of 237 (30.8%) APS samples were LA-positive with 1 assay, 40/237 (16.9%) by dRVVT only, and 33/237 (13.9%) with APTT only. Nineteen of 45 (42.2%) were LA-positive with 1 assay in the systemic lupus erythematosus cohort; 12/45 (26.7%) with dRVVT only and 7/45 (15.5%) with APTT only. Thirty-three of 60 (55.0%) were LA-positive with 1 assay in the nonclinical criteria cohort; 24/60 (40.0%) with dRVVT only and 9/60 (15.0%) with APTT only. The most common solid-phase assay profile was elevated immunoglobulin G aCL and aß2GPI. CONCLUSION: Up to 55.0% of triple-positive samples were positive in 1 LA assay, representing significant potential for misdiagnosis and inappropriate management via single LA assay repertoires.


Assuntos
Síndrome Antifosfolipídica , Lúpus Eritematoso Sistêmico , Humanos , Síndrome Antifosfolipídica/diagnóstico , Inibidor de Coagulação do Lúpus , Testes de Coagulação Sanguínea , Anticorpos Antifosfolipídeos , Tempo de Protrombina , Tempo de Tromboplastina Parcial , Lúpus Eritematoso Sistêmico/diagnóstico
3.
J Blood Med ; 7: 217-225, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27713652

RESUMO

Acquired hypofibrinogenemia is most frequently caused by hemodilution and consumption of clotting factors. The aggressive replacement of fibrinogen has become one of the core principles of modern management of massive hemorrhage. The best method for determining the patient's fibrinogen level remains controversial, and particularly in acquired dysfibrinogenemia, could have major therapeutic implications depending on which quantification method is chosen. This review introduces the available laboratory and point-of-care methods and discusses the relative advantages and limitations. It also discusses current strategies for the correction of hypofibrinogenemia.

4.
Semin Thromb Hemost ; 36(7): 712-22, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20978992

RESUMO

The thromboelastography trace provides a graphical and numerical representation of the viscoelastic changes associated with fibrin polymerization. When used with whole blood, the shape of this trace is a composite of the effects of white and red cell content and composition, platelet number and function, fibrinogen concentration, as well as coagulation protein function and balance. The trace is also influenced by pharmacological agents such as anticoagulants, antiplatelet therapy, and coagulation factor supplementation. As such the main role of this technology has been as a point-of-care device to guide transfusion of blood components. Recently the technology has moved from the cardiac and hepatic surgical settings, where most of the early work was focused, into other areas of hemostatic monitoring. New applications for pharmaceutical monitoring and patient screening are being explored. This review gives a broad overview of the applications of the technology. In particular it considers the factors that most influence the characteristics of the trace, be they preanalytical, analytical, or clinical.


Assuntos
Anticoagulantes/uso terapêutico , Tromboelastografia/métodos , Hemostasia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...