Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Skeletal Radiol ; 51(1): 153-159, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34132888

RESUMO

PURPOSE: Multi-detector computed tomography (MDCT) is superior in fracture detection than conventional radiography; however, dose is increased. Cone-beam computed tomography (CBCT) offers higher spatial resolution and lower dose than MDCT. Manufacturers offer an ultra-low-dose algorithm. This study compares the diagnostic accuracy of the ultra-low-dose CBCT (ULDCBCT) with that of the standard-dose CBCT (SDCBCT). MATERIALS AND METHODS: In total, 64 patients were scanned with both the SDCBCT and the ULDCBCT protocols. Both studies were reported by two consultant radiologists with fellowship training in emergency radiology separated in time. The reporter recorded a diagnosis of fracture or normal and diagnostic confidence using a 5-point Likert scale. The gold standard was taken as the SDCBCT. Reporters were blinded to the indication and the SDCBCT report. Cases of discrepancy were resolved by consensus. RESULTS: There were 34 fractures and 30 cases had no fracture. Several fractures were missed using the UDCBCT, and there were also several cases of overdiagnosis. ULD was inferior to SD for fracture diagnosis (p < 0.00001). The diagnostic accuracy of ULDCBCT was 82.8% (75.1-88.9 CI). The diagnostic accuracy of plain radiograph was 64% (55.1-75.7% CI). Diagnostic confidence was reduced; the mean confidence for SDCBCT was 4.68 vs 4.12 for ULDCBCT (p < 0.001). The Kappa for interobserver agreement was 0.6. CONCLUSION: ULDCBCT is inferior to SDCBCT in fracture detection and confidence is reduced. For diagnostic studies, the standard dose should be used.


Assuntos
Fraturas Ósseas , Radiologia , Tomografia Computadorizada de Feixe Cônico , Fraturas Ósseas/diagnóstico por imagem , Humanos , Tomografia Computadorizada Multidetectores , Radiografia
2.
Clin Radiol ; 76(5): 384-390, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33691952

RESUMO

AIM: To report an audit of the evaluation of suspected, unconfirmed cases of COVID-19 including chest computed tomography (CT), as compared to World Health Organization recommendations. METHODS: A clinical audit was undertaken examining the evaluation of patients with suspected COVID-19 with negative SARS-CoV-2 reverse transcriptase polymerase chain reaction (RT-PCR) results, with comparison to WHO recommendations. A retrospective chart review was undertaken for 90 patients examining investigations, in particular CT, used to clarify the diagnosis. RESULTS: Ninety patients underwent additional investigation. Seventy-five per cent adherence to WHO recommendations was observed. Fifty-two men (57.78%) and 38 (42.22%) women were investigated, with a median age of 69 years (range 20-96 years). Seventy-nine chest CT examinations demonstrated positive, indeterminate, and negative rates for COVID-19 of 3.79%, 24.1%, and 72.15% respectively. Three patients had discordant swab results with initially negative and subsequently positive results for SARS-CoV-2, resulting in false-negative rates of 5.1% for those retested. Combining discordant RT-PCR swab results, positive radiology, and patients treated as COVID-19-positive due to indeterminate radiology and highly consistent symptoms, resulted in a false-negative rate for initial SARS-CoV-2 RT-PCR swabs of 16.67%. CONCLUSION: Seventy-five per cent compliance with relevant WHO guidance and a false-negative rate for initial swabs of 16.67% was demonstrated. Further evidence is needed to fully determine the utility of chest CT in the diagnosis of COVID-19 in the context of initial false-negative RT-PCR results.


Assuntos
COVID-19/diagnóstico por imagem , Procedimentos Clínicos , Fidelidade a Diretrizes , Pulmão/diagnóstico por imagem , Guias de Prática Clínica como Assunto , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Teste de Ácido Nucleico para COVID-19 , Reações Falso-Negativas , Feminino , Humanos , Masculino , Auditoria Médica , Pessoa de Meia-Idade , Equipe de Assistência ao Paciente , Estudos Retrospectivos , SARS-CoV-2 , Organização Mundial da Saúde , Adulto Jovem
3.
Radiography (Lond) ; 27(2): 389-397, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33036913

RESUMO

INTRODUCTION: To investigate the impact of parameter optimisation for novel three-dimensional 3D sequences at 1.5T and 3T on resultant image quality. METHODS: Following institutional review board approval and acquisition of informed consent, MR phantom and knee joint imaging on healthy volunteers (n = 16) was performed with 1.5 and 3T MRI scanners, respectively incorporating 8- and 15-channel phased array knee radiofrequency coils. The MR phantom and healthy volunteers were prospectively scanned over a six-week period. Acquired sequences included standard two-dimensional (2D) turbo spin echo (TSE) and novel three-dimensional (3D) TSE PDW (SPACE) both with and without fat-suppression, and T2∗W gradient echo (TrueFISP) sequences. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured for knee anatomical structures. Two musculoskeletal radiologists evaluated anatomical structure visualisation and image quality. Quantitative and qualitative findings were investigated for differences using Friedman tests. Inter- and intra-observer agreements were determined with κ statistics. RESULTS: Phantom and healthy volunteer images revealed higher SNR for sequences acquired at 3T (p-value <0.05). Generally, the qualitative findings ranked images acquired at 3T higher than corresponding images acquired at 1.5T (p < 0.05). 3D image data sets demonstrated less sensitivity to partial volume averaging artefact (PVA) compared to 2D sequences. Inter- and intra-observer agreements for evaluation across all sequences ranged from 0.61 to 0.79 and 0.71 to 0.92, respectively. CONCLUSION: Both 2D and 3D images demonstrated higher image quality at 3T than at 1.5T. Optimised 3D sequences performed better than the standard 2D PDW TSE sequence for contrast resolution between cartilage and joint fluid, with reduced PVA artefact. IMPLICATIONS FOR PRACTICE: With rapid advances in MRI scanner technology, including hardware and software, the optimisation of 3D MR pulse sequences to reduce scan time while maintaining image quality, will improve diagnostic accuracy and patient management in musculoskeletal MRI.


Assuntos
Articulação do Joelho , Imageamento por Ressonância Magnética , Humanos , Imageamento Tridimensional , Joelho/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Razão Sinal-Ruído
5.
Emerg Radiol ; 27(3): 321-328, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32060659

RESUMO

Mass casualty incidents (MCIs) create a large number of casualties in a short period of time. Diagnostic radiology plays an important role in major incident responses but is often underrepresented during major incident planning (MIP) and simulation. Surveys suggest radiologists are unfamiliar with their role during an MCI. We aimed to identify key topics for radiology MIP, familiarize radiologists with their role during an MCI and identify areas for future research. The terms "radiology" and "mass casualty incident" were entered into the advanced search builder on PubMed. Abstracts from this primary search were reviewed and papers selected for inclusion. Additional studies of interest were identified upon review of reference sections of relevant articles and from the related article tab on PubMed. MCI and trauma guidelines were reviewed. Key factors that caused issues during prior MCIs were identified including staff alert mechanisms, patient identification strategies, patient tracking, scan ordering and result communication. Limitations of local imaging resources and capacity should be identified and inform plans for the utilization of diagnostic radiology in the MCI setting. Simulation can help identify areas for improvement and familiarize staff with their roles. Further development of reliable MCI alert technology and patient identification strategies are needed as well as prospective validation of trauma CT selection criteria to identify patients who will benefit most from CT. Radiology should take part in MIP to address key issues encountered during prior MCIs and in MCI simulation to optimize major incident response.


Assuntos
Diagnóstico por Imagem , Incidentes com Feridos em Massa , Ferimentos e Lesões/diagnóstico por imagem , Serviço Hospitalar de Emergência/organização & administração , Humanos , Técnicas de Planejamento , Serviço Hospitalar de Radiologia/organização & administração
6.
Emerg Radiol ; 27(3): 293-301, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32095905

RESUMO

PURPOSE: To qualitatively assess the legibility of radiopaque patient identification stickers and their effect on image quality. These stickers are intended for use as a part of a patient registration and identification pack utilized in a mass casualty incident (MCI), to prevent errors in correlating patients with their diagnostic imaging and reports. METHODS: Four different prototype designs of stickers with radiopaque identification numbers which are legible on radiographs and CT were created. These were affixed to head and thorax phantoms and scanned using standard imaging protocols. Images were reviewed qualitatively for legibility and the presence of image degradation due to the radiopaque sticker materials using Likert scales by four radiologists and four emergency physicians. RESULTS: All four prototypes were confidently legible on forehead, shoulder and sternum on CT on topogram and reconstructed images. Sticker positioning over the temple resulted in unreliable legibility on topogram. All prototypes were confidently legible on shoulder and sternum on CT and radiographs. Significant image degradation was reported on radiographs with sticker position over the sternum. The preferred anatomic position was the forehead. CONCLUSION: In a mass casualty incident, radiopaque patient identification stickers affixed to injured patients may help to ensure confidence in the correlation between patients and their imaging. Tested prototypes were found to be easily legible without substantial degradation of image quality. Preferred anatomical position and construction material was established. Consideration should be given to addition of such radiographic identity aides to MCI patient registration packs.


Assuntos
Incidentes com Feridos em Massa , Sistemas de Identificação de Pacientes , Tomografia Computadorizada por Raios X , Artefatos , Desenho de Equipamento , Testa , Humanos , Imagens de Fantasmas , Ombro , Esterno
7.
Emerg Radiol ; 26(5): 531-540, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31250231

RESUMO

PURPOSE: Fractures of the trapezium are rarely diagnosed on plain radiographs after acute wrist trauma. High-resolution cross-sectional imaging identifies fractures of the trapezium as the most common radiographically occult carpal bone fracture. We review the fracture frequency, mechanisms and patterns of trapezium fractures. METHODS: Cone beam CT was performed in patients with suspected radiographically occult radiocarpal fracture following acute injury. The frequency of carpal bone fractures was assessed and compared. RESULTS: Ninety-three radiographically occult wrist fractures were identified in 166 patients with acute trauma and negative radiographs. The trapezium was the most frequently fractured carpal bone, making up 20.4% of wrist fractures. Seventy-nine percent of trapezium fractures involved the volar ridge. The scaphoid was the clinically suspected fractured bone at initial assessment in 84% of patients with trapezium fractures. CONCLUSION: Fractures of the trapezium in acute wrist trauma are much more common than described in the literature. If initial radiographs are negative, a fracture of the trapezium is more likely to be present than one of the scaphoid, despite high levels of clinical suspicion for scaphoid injuries. Awareness of the types and mechanisms of trapezium fracture is important. Cross-sectional imaging should be considered in all cases of post-traumatic wrist pain with negative radiographs.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Fraturas Ósseas/diagnóstico por imagem , Osso Escafoide/diagnóstico por imagem , Osso Escafoide/lesões , Trapézio/diagnóstico por imagem , Trapézio/lesões , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
AJNR Am J Neuroradiol ; 39(4): E48, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29301778
9.
AJNR Am J Neuroradiol ; 39(3): E46, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29242357
10.
Surgeon ; 16(3): 131-136, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28012704

RESUMO

Scaphoid fractures constitute 71% of all carpal bone fractures.1 Early diagnosis and treatment has significant bearing on fracture union rates and better clinical outcomes. While displaced fractures can be readily seen on plain radiograph, undisplaced fractures can require advanced imaging modalities to confirm that diagnosis. Advanced imaging such as Magnetic Resonance Imaging (MRI), Computerised tomography (CT) and bone scintigraphy are routinely used for the diagnosis of scaphoid fractures but require significant radiation exposure, increased cost and can be difficult to access.2 Tomosynthesis is an emerging imaging modality which uses conventional x-ray systems to produce cross-sectional images. There has yet to be extensive research carried out investigating the diagnostic value of tomosynthesis in scaphoid fractures. The aim of this study is to optimise patient positioning for the diagnosis of scaphoid fractures in a cadaveric model and compare the diagnostic yield of tomography to conventional CT. Using four cadaveric specimens, three limb positions were examined in unfractured and fractured scaphoids to determine the optimal limb positions required for visualisation of the scaphoid. As a result of this study, the optimal position for visualisation of the scaphoid and diagnosis of scaphoid fractures has been determined. The results demonstrate that tomosynthesis is as effective as CT scanning in identifying scaphoid fractures in both sensitivity and specificity. By comparison to CT, tomosynthesis is cheaper, has lower radiation exposure, requires fewer hospital resources and can be performed quickly. Tomosynthesis is a valid diagnostic tool for the diagnosis of scaphoid fractures.


Assuntos
Fraturas Ósseas/diagnóstico por imagem , Osso Escafoide/diagnóstico por imagem , Osso Escafoide/lesões , Anatomia Transversal , Cadáver , Humanos , Posicionamento do Paciente , Tomografia , Tomografia Computadorizada por Raios X
11.
World J Emerg Surg ; 12: 47, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29075316

RESUMO

BACKGROUND: Opportunities to improve emergency surgery outcomes exist through guided better practice and reduced variability. Few attempts have been made to define optimal care in emergency surgery, and few clinically derived key performance indicators (KPIs) have been published. A summit was therefore convened to look at resources for optimal care of emergency surgery. The aim of the Donegal Summit was to set a platform in place to develop guidelines and KPIs in emergency surgery. METHODS: The project had multidisciplinary global involvement in producing consensus statements regarding emergency surgery care in key areas, and to assess feasibility of producing KPIs that could be used to monitor process and outcome of care in the future. RESULTS: Forty-four key opinion leaders in emergency surgery, across 7 disciplines from 17 countries, composed evidence-based position papers on 14 key areas of emergency surgery and 112 KPIs in 20 acute conditions or emergency systems. CONCLUSIONS: The summit was successful in achieving position papers and KPIs in emergency surgery. While position papers were limited by non-graded evidence and non-validated KPIs, the process set a foundation for the future advancement of emergency surgery.


Assuntos
Lesões Encefálicas Traumáticas/cirurgia , Pediatria/métodos , Acidentes por Quedas/mortalidade , Acidentes por Quedas/estatística & dados numéricos , Acidentes de Trânsito/mortalidade , Acidentes de Trânsito/estatística & dados numéricos , Adolescente , Mundo Árabe , Lesões Encefálicas Traumáticas/epidemiologia , Criança , Pré-Escolar , Técnica Delphi , Feminino , Humanos , Lactente , Masculino , Oriente Médio/epidemiologia , Pediatria/tendências , Estudos Retrospectivos , Centros de Traumatologia/organização & administração , Centros de Traumatologia/estatística & dados numéricos , Resultado do Tratamento
12.
AJNR Am J Neuroradiol ; 38(10): 1911-1916, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28798219

RESUMO

BACKGROUND AND PURPOSE: Multiphase CTA, a technique to dynamically assess the vasculature in acute ischemic stroke, was primarily developed to evaluate collateral filling. We have observed that it is also useful in identifying distal anterior circulation occlusions due to delayed anterior circulation opacification on multiphase CTA, an observation we term the "delayed vessel sign." We aimed to determine the usefulness of this sign by comparing multiphase CTA with single-phase CTA. MATERIALS AND METHODS: All 23 distal anterior circulation occlusions during a 2-year period were included. Ten M1-segment occlusions and 10 cases without a vessel occlusion were also included. All patients had follow-up imaging confirming the diagnosis. Initially, the noncontrast CT and first phase of the multiphase CTA study for each patient were blindly evaluated (2 neuroradiologists, 2 radiology trainees) for an anterior circulation occlusion. Readers' confidence, speed, and sensitivity of detection were recorded. Readers were then educated on the "delayed vessel sign," and each multiphase CTA study was re-examined for a vessel occlusion after at least 14 days. RESULTS: There was significant improvement in the sensitivity of detection of distal anterior circulation vessel occlusions (P < .001), overall confidence (P < .001), and time taken to interpret (P < .001) with multiphase CTA compared with single-phase CTA. Readers preferred MIP images compared with source images in >90% of cases. CONCLUSIONS: The delayed vessel sign is a reliable indicator of anterior circulation vessel occlusion, particularly in cases involving distal branches. Assessment of the later phases of multiphase CTA for the delayed vessel sign leads to a significant improvement in the speed and confidence of interpretation, compared with single-phase CTA.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Angiografia Cerebral/métodos , Angiografia por Tomografia Computadorizada/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
13.
Ir Med J ; 110(4): 549, 2017 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-28665088

RESUMO

We report a radiologic finding on magnetic resonance imaging (MRI) of the brain of two cases of progressive multifocal leukoencephalopathy (PML) of hypointense signal of subcortical U-fibres on susceptibility weighted (SW) sequence. The first case is a 50-year-old man recently treated with chemotherapy including rituximab for non-Hodgkin's lymphoma. The second case is a 64-year-old woman with human immunodeficiency virus (HIV) infection. Iron deposition is a likely causative factor. We propose that SWI may be especially useful in the assessment of indeterminate cases to reduce the likelihood of a missed diagnosis of PML.


Assuntos
Encéfalo/diagnóstico por imagem , Leucoencefalopatia Multifocal Progressiva/diagnóstico por imagem , Imageamento por Ressonância Magnética , Antineoplásicos Imunológicos/uso terapêutico , Feminino , Infecções por HIV/complicações , Humanos , Linfoma não Hodgkin/tratamento farmacológico , Masculino , Pessoa de Meia-Idade , Rituximab/uso terapêutico
14.
AJNR Am J Neuroradiol ; 38(9): 1664-1671, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28408630

RESUMO

Imaging for the diagnosis and follow-up of patients with suspected or confirmed multiple sclerosis is a common scenario for many general radiologists and subspecialty neuroradiologists. The field of MS therapeutics has rapidly evolved with multiple new agents now being used in routine clinical practice. To provide an informed opinion in discussions concerning newer MS agents, radiologists must have a working understanding of the strengths and limitations of the various novel therapies. The role of imaging in MS has advanced beyond monitoring and surveillance of disease activity to include treatment complications. An understanding of the new generation of MS drugs in conjunction with the key role that MR imaging plays in the detection of disease progression, opportunistic infections, and drug-related adverse events is of vital importance to the radiologist and clinical physician alike. Radiologists are in a unique position to detect many of the described complications well in advance of clinical symptoms. Part 1 of this review outlines recent developments in the treatment of MS and discusses the published clinical data on the efficacy and safety of the currently approved and emerging therapies in this condition as they apply to the radiologist. Part 2 will cover pharmacovigilance and the role the neuroradiologist plays in monitoring patients for signs of opportunistic infection and/or disease progression.


Assuntos
Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/tratamento farmacológico , Radiologistas , Encéfalo/diagnóstico por imagem , Humanos , Imunossupressores/efeitos adversos , Imunossupressores/uso terapêutico , Farmacovigilância
15.
AJNR Am J Neuroradiol ; 38(9): 1672-1680, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28428206

RESUMO

An understanding of the new generation of MS drugs in conjunction with the key role MR imaging plays in the detection of disease progression, opportunistic infections, and drug-related adverse effects is of vital importance to the neuroradiologist. Part 1 of this review outlined the current treatment options available for MS and examined the mechanisms of action of the various medications. It also covered specific complications associated with each form of therapy. Part 2, in turn deals with the subject of pharmacovigilance and the optimal frequency of MRI monitoring for each individual patient, depending on his or her unique risk profile. Special attention is given to the diagnosing of progressive multifocal leukoencephalopathy in patients treated with natalizumab as this is a key area in which neuroradiologists can contribute to improved patient outcomes. This article also outlines the aims of treatment and reviews the possibility of "no evidence of disease activity" becoming a treatment goal with the availability of more effective therapies. Potential future areas and technologies including image subtraction, brain volume measurement and advanced imaging techniques such as double inversion recovery are also reviewed. It is anticipated that such advancements in this rapidly developing field will improve the accuracy of monitoring an individual patient's response to treatment.


Assuntos
Esclerose Múltipla/tratamento farmacológico , Esclerose Múltipla/terapia , Radiologistas , Anticorpos Monoclonais Humanizados/efeitos adversos , Anticorpos Monoclonais Humanizados/uso terapêutico , Humanos , Leucoencefalopatia Multifocal Progressiva/complicações , Leucoencefalopatia Multifocal Progressiva/diagnóstico , Leucoencefalopatia Multifocal Progressiva/tratamento farmacológico , Leucoencefalopatia Multifocal Progressiva/terapia , Esclerose Múltipla/complicações , Natalizumab/efeitos adversos , Natalizumab/uso terapêutico , Resultado do Tratamento
16.
Eur J Radiol ; 86: 184-189, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28027745

RESUMO

OBJECTIVE: The aims of our study were to evaluate the contribution of contrast-monitoring techniques to breast dose in pregnant and non-pregnant women, and to investigate the effect of a reduced peak kilovoltage (kV) monitoring scan protocol on breast dose and Computed Tomography Pulmonary Angiography (CTPA) diagnostic quality. MATERIALS AND METHODS: Single center retrospective study of 221 female patients undergoing a reduced kV 80kV contrast-monitoring CTPA protocol compared to 281 patients using the conventional 120kV contrast-monitoring protocol (Siemens Somatom Definition AS+). 99 pregnant patients analyzed separately. ImPACT dosimetry software was used to calculate dose. Group subsets were evaluated to assess CTPA diagnostic quality. RESULTS: The contrast-monitoring component of a CTPA study constituted 27% of the overall breast dose when using a standard 120kV protocol compared to only 7% of the overall breast dose in the 80kV study group. The dose to the breast from the contrast-monitoring component alone was reduced by 79% in the non-pregnant patients (0.36mGy±0.37 versus 1.7mGy±1.02; p<0.001), and by 88% in the pregnant population (0.25mGy±0.67 versus 2.24mGy±1.61; p<0.001). There was no statistical difference in CTPA diagnostic quality or timing. CONCLUSION: Despite a short scan length and relatively small DLP, contrast-monitoring techniques (test-bolus or bolus-tracked) set at 120kV can account for 27% of the overall breast dose accrued from a CTPA study. By decreasing the kilovoltage of the contrast-monitoring component, a significant reduction in breast dose for pregnant and non-pregnant female patients can be achieved without affecting CTPA quality or timing.


Assuntos
Mama/efeitos dos fármacos , Complicações Cardiovasculares na Gravidez/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Doses de Radiação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Gravidez , Radiometria , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
17.
Ir Med J ; 109(4): 397, 2016 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-27685491

RESUMO

Ischaemic stroke clinical outcomes are improved by earlier treatment with intravenous thrombolysis. An existing pathway at the Mater University Hospital for assessment of suspected acute stroke in the Emergency Department was updated, aiming to shorten door-to-needle time. This study examines the final clinical diagnosis of Dublin Fire Brigade Ambulance Paramedic identified Face-Arm-Speech-Test (FAST) positive patients presenting to the Emergency Department over a 7 month period. A retrospective analysis was carried out of 177 consecutive FAST positive patients presenting between March and November 2014. The final clinical diagnosis was acute stroke in 57.1% (n=101) of patients. Of these, 76 were ischaemic strokes of whom 56.5% (n=43) were thrombolysed. In the pre-hospital setting Ambulance Paramedics can identify, with reasonable accuracy, acute stroke using the FAST test. Over half of the ischaemic stroke patients presenting via this pathway can be treated with intravenous thrombolysis.

19.
J Intellect Disabil Res ; 59(4): 342-52, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25092530

RESUMO

BACKGROUND: People with intellectual disabilities (ID) are rarely asked about their experiences as users of psychological services and little is known about the views of clients with ID who have undergone cognitive behavioural therapy (CBT). This study aimed to gather the views of adults with ID who had recently taken part in a cluster randomised control trial (RCT) of a staff-delivered manualised CBT anger management group intervention. METHOD: A qualitative method, Interpretative Phenomenological Analysis (IPA), was employed and eleven participants were interviewed. The interviews took place after the intervention, within two weeks of the end of the group, to gain an understanding of service users' experiences of participating in a CBT group. RESULTS: IPA of the interview transcripts indicated that the intervention was experienced as effective and enjoyable and a number of themes were identified including: 'the importance of relationships', 'a new me', 'new and improved relationships', 'presenting myself in a positive light' and 'what the group didn't change'. CONCLUSIONS: The results will be discussed in the context of applying group CBT for adults with ID and implications for service development.


Assuntos
Terapia de Controle da Ira/métodos , Terapia Cognitivo-Comportamental/métodos , Deficiência Intelectual/psicologia , Relações Interpessoais , Psicoterapia de Grupo/métodos , Pesquisa Qualitativa , Adulto , Atitude Frente a Saúde , Análise por Conglomerados , Feminino , Humanos , Masculino , Satisfação do Paciente , Resultado do Tratamento , Adulto Jovem
20.
J Intellect Disabil Res ; 59(1): 68-81, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24404992

RESUMO

BACKGROUND: Anger and aggression among adults with intellectual disability (ID) are associated with a range of adverse consequences for their well-being and that of their family or staff carers. The aims were to evaluate the effectiveness of an anger management intervention for adults with mild to moderate ID and to evaluate the costs of the intervention and its impact on health and social care resource use. This paper is concerned with the latter aim. METHODS: A cluster-randomised controlled trial was conducted involving day services for adults with ID in Scotland, England and Wales. Incremental costs of delivering the intervention and its impact on subsequent total health and social care package costs were calculated. Full data comparing costs between baseline and follow-up 10 months later were collected for 67 participants in the intervention arm and 62 participants in the control arm. Cost differences between the groups at follow-up, adjusted for baseline levels, were calculated using non-parametric bootstrapping controlling for clustering. RESULTS: The mean hourly excess cost of intervention over treatment as usual was £12.34. A mean adjusted cost difference of £22.46 per person per week in favour of the intervention group was found but this was not statistically significant. CONCLUSIONS: The baseline-adjusted cost difference at follow-up would result in a fairly immediate compensation for the excess costs of intervention, provided the difference is not a statistical artefact. Further research is needed to clarify the extent to which it might represent a real saving in service support costs.


Assuntos
Ira/fisiologia , Terapia Cognitivo-Comportamental/economia , Serviços de Saúde/economia , Deficiência Intelectual/economia , Deficiência Intelectual/terapia , Adulto , Inglaterra , Feminino , Seguimentos , Serviços de Saúde/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Escócia , País de Gales
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...