Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Otolaryngol Head Neck Surg ; 166(5): 943-950, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34399646

RESUMO

OBJECTIVE: To compare differences in audiologic outcomes between slim modiolar electrode (SME) CI532 and slim lateral wall electrode (SLW) CI522 cochlear implant recipients. STUDY DESIGN: Retrospective cohort study. SETTING: Tertiary academic hospital. METHODS: Comparison of postoperative AzBio sentence scores in quiet (percentage correct) in adult cochlear implant recipients with SME or SLW matched for preoperative AzBio sentence scores in quiet and aided and unaided pure tone average. RESULTS: Patients with SLW (n = 52) and patients with SME (n = 37) had a similar mean (SD) age (62.0 [18.2] vs 62.6 [14.6] years, respectively), mean preoperative aided pure tone average (55.9 [20.4] vs 58.1 [16.4] dB; P = .59), and mean AzBio score (percentage correct, 11.1% [13.3%] vs 8.0% [11.5%]; P = .25). At last follow-up (SLW vs SME, 9.0 [2.9] vs 9.9 [2.6] months), postoperative mean AzBio scores in quiet were not significantly different (percentage correct, 70.8% [21.3%] vs 65.6% [24.5%]; P = .29), and data log usage was similar (12.9 [4.0] vs 11.3 [4.1] hours; P = .07). In patients with preoperative AzBio <10% correct, the 6-month mean AzBio scores were significantly better with SLW than SME (percentage correct, 70.6% [22.9%] vs 53.9% [30.3%]; P = .02). The intraoperative tip rollover rate was 8% for SME and 0% for SLW. CONCLUSIONS: Cochlear implantation with SLW and SME provides comparable improvement in audiologic functioning. SME does not exhibit superior speech recognition outcomes when compared with SLW.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adolescente , Adulto , Cóclea/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento
2.
Laryngoscope ; 131(3): 624-632, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32427386

RESUMO

OBJECTIVES: To determine the safety and effectiveness of the middle cranial fossa (MCF) approach in repairing spontaneous cerebrospinal fluid (sCSF) leaks. STUDY DESIGN: Retrospective cohort study. METHODS: Patient with sCSF leaks repaired by MCF approach between January 1, 2014 and August 31, 2019 were included. Demographic information, clinical and surgical findings, and postoperative outcomes were recorded. RESULTS: The cohort (n = 45) included 24 tegmen repairs by multilayer reconstruction using hydroxyapatite cement and 21 cases of multilayer repair without hydroxyapatite cement. Ten MCF repairs were performed on patients ≥65 years old. Twenty (53%) ears had multiple tegmen defects (range, 1-9 tegmen defects) and 78% of patients had ≥1 encephaloceles. All sCSF leaks were resolved with one surgical intervention. There were no major intracranial complications. Transient expressive aphasia occurred in 2 patients. Medical complications occurred in four patients. There were no short-term postoperative CSF leaks with bone cement reconstruction and two postoperative leaks without bone cement. One resolved with lumbar drain (LD) and the other resolved without treatment. The average (SD) length of stay (LOS) with bone cement was shorter than in patients without bone cement (2.54 [0.83] days vs. 3.52 [1.99] days, P < .05). There have been no long-term CSF leak recurrences with an average (SD) follow-up of 13.5 (12.9) months (range 0.25-46 months). CONCLUSIONS: MCF approach for sCSF repairs demonstrate efficacious outcomes, particularly with tegmen reconstruction using hydroxyapatite cement. The approach exhibited no serious adverse events and few complications requiring intervention. Therefore, MCF is a safe and effective approach to resolve sCSF leaks. LEVEL OF EVIDENCE: 3 Laryngoscope, 131:624-632, 2021.


Assuntos
Cimentos Ósseos/uso terapêutico , Vazamento de Líquido Cefalorraquidiano/cirurgia , Fossa Craniana Média/cirurgia , Hidroxiapatitas/uso terapêutico , Procedimentos de Cirurgia Plástica/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Osso Temporal/cirurgia , Resultado do Tratamento
3.
J Craniofac Surg ; 32(1): 345-349, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32890157

RESUMO

OBJECTIVE: Temporal bone spontaneous cerebrospinal fluid (sCSF) leaks are characterized by defects in the tegmen along with calvarial thinning without associated thinning of the extracranial zygoma. The authors sought to determine the effect of age and race on calvarial, tegmen, and zygoma thickness. STUDY DESIGN: Retrospective cohort study. SETTING: Tertiary Referral Center. PATIENTS: A total of 446 patients with high-resolution head computer tomography (CT) imaging from 2003 to 2018.Intervention(s): Calvarial, tegmen, and zygoma thicknesses were measured using 3D slicer.Main Outcome Measure(s): Effects of age and race on calvarium, tegmen, zygoma thickness. RESULTS: Among all patients, increased age was associated with increased thickness of the calvarium [95% CI, 0.0002 to 0.007 mm/year, P < 0.05] and tegmen [95% CI, 0.00039 to 0.0075 mm/year, P = 0.03], but decreased thickness of the zygoma [95% CI, -0.013 to -0.005 mm/year, P < 0.001]. When compared to white patients, black patients had thicker mean [SD] calvaria (2.63 [0.61] versus 3.30 [0.79] mm; difference, 0.67 mm; [95% CI, 0.57 to 0.77]; Cohen d, 1.02), tegmen (0.73 [0.34] versus 0.92 [0.36] mm; difference 0.19 mm; [95% CI, 0.101 to 0.279]; Cohen d, 0.533) and zygoma (4.89 [0.81] versus 5.55 [0.91] mm; difference, 0.66 mm; [95% CI, 0.53 to 0.79]; Cohen d, 0.78). CONCLUSIONS: Racial differences exist in calvarial and zygoma thickness. Aging generally leads to increased calvarium and tegmen thickness, suggesting that early onset of obesity and comorbid conditions known to thin the skull base may predispose patients to developing sCSF leaks by reversing the effects of age.


Assuntos
Base do Crânio , Zigoma , Vazamento de Líquido Cefalorraquidiano , Humanos , Estudos Retrospectivos , Osso Temporal , Zigoma/diagnóstico por imagem
4.
Gastrointest Endosc ; 91(1): 115-120, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31299257

RESUMO

BACKGROUND AND AIMS: Devices for flattening colon folds can improve polyp detection at colonoscopy. However, there are few data on the endoscopic ring-fitted cap (EndoRings; EndoAid, Caesarea, Israel). We sought to compare adenoma detection with EndoRings with that of standard high-definition colonoscopy. METHODS: This was a single-center, randomized controlled trial of 562 patients (284 randomized to EndoRings and 278 to standard colonoscopy) at 2 outpatient endoscopy units in the Indiana University Hospital system. Adenoma detection was the primary outcome measured as adenoma detection rate (ADR) and adenomas per colonoscopy (APC). We also compared sessile serrated polyp detection rate, insertion times, withdrawal times, and ease of passage through the sigmoid colon. RESULTS: EndoRings was superior to standard colonoscopy in terms of APC (1.46 vs 1.06, P = .025), but there were no statistically significant differences in ADR or sessile serrated polyp detection rate. Mean withdrawal time (in patients with no polyps) was shorter and insertion time (all patients) was longer in the EndoRings arm by 1.8 minutes and 0.75 minutes, respectively. One provider had significantly higher detection with Endo-Rings and contributed substantially to the overall results. CONCLUSIONS: EndoRings can increase adenoma detection without a significant increase in procedure time, but the effect varies between operators. The use of EndoRings slows colonoscope insertion. (Clinical trial registration number: NCT03418662.).


Assuntos
Adenoma/diagnóstico por imagem , Neoplasias do Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Colonoscopia/instrumentação , Adenoma/patologia , Idoso , Neoplasias do Colo/patologia , Pólipos do Colo/patologia , Colonoscópios , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia
5.
Gastrointest Endosc ; 90(5): 807-812, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31288028

RESUMO

BACKGROUND AND AIMS: Viscous solutions provide a superior submucosal cushion for EMR. SIC-8000 (Eleview; Aries Pharmaceuticals, La Jolla, Calif) is a commercially available U.S. Food and Drug Administration-approved solution, but hetastarch is also advocated. We performed a randomized trial comparing SIC-8000 with hetastarch as submucosal injection agents for colorectal EMR. METHODS: This was a single-center, double-blinded, randomized controlled trial performed at a tertiary referral center. Patients were referred to our center with flat or sessile lesions measuring ≥15 mm in size. The primary outcome measures were the Sydney resection quotient (SRQ) and the rate of en bloc resections. Secondary outcomes were total volume needed for a sufficient lift, number of resected pieces, and adverse events. RESULTS: There were 158 patients with 159 adenomas (SIC-8000, 84; hetastarch, 75) and 57 serrated lesions (SIC-8000, 30; hetastarch, 27). SRQ was significantly better in the SIC-8000 group compared with hetastarch group (9.3 vs 8.1, P = .001). There was no difference in the proportion of lesions with en bloc resections. The total volume of injectate was significantly lower with SIC-8000 (14.8 mL vs 20.6 mL, P = .038). CONCLUSIONS: SIC-8000 is superior to hetastarch for use during EMR in terms of SRQ and total volume needed, although the absolute differences were small. (Clinical trial registration number: NCT03350217.).


Assuntos
Adenoma/cirurgia , Neoplasias do Colo/cirurgia , Ressecção Endoscópica de Mucosa , Derivados de Hidroxietil Amido/administração & dosagem , Mucosa Intestinal/cirurgia , Poloxâmero/administração & dosagem , Idoso , Feminino , Humanos , Injeções , Masculino , Pessoa de Meia-Idade , Soluções Farmacêuticas/administração & dosagem
6.
Endoscopy ; 51(3): 221-226, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30722072

RESUMO

BACKGROUND: Diminutive colorectal polyps resected during colonoscopy are sometimes histologically interpreted as normal tissue. The aim of this observational study was to explore whether errors in specimen handling or processing account in part for polyps ≤ 3 mm in size being interpreted as normal tissue by pathology when they were considered high confidence adenomas by an experienced endoscopist at colonoscopy. METHODS: One endoscopist photographed 900 consecutive colorectal lesions that were ≤ 3 mm in size and considered endoscopically to be high confidence conventional adenomas. The photographs were reviewed blindly to eliminate poor quality images. The remaining 644 endoscopy images were reviewed by two external experts who predicted the histology while blinded to the pathology results. RESULTS: Of 644 consecutive lesions ≤ 3 mm in size considered high confidence conventional adenomas by a single experienced colonoscopist, 15.4 % were reported as normal mucosa by pathology. The prevalence of reports of normal mucosa in polyps removed by cold snare and cold forceps were 15.2 % and 16.0 %, respectively. When endoscopy photographs were reviewed by two blinded outside experts, the lesions found pathologically to be adenomas and normal mucosa were interpreted as high confidence adenomas by endoscopic appearance in 96.9 % and 93.9 %, respectively, by Expert 1 (P = 0.15), and in 99.6 % and 100 %, respectively, by Expert 2 (P = 0.51). CONCLUSION: Retrieval and/or processing of tissue specimens of tiny colorectal polyps resulted in some lesions being diagnosed as normal tissue by pathology despite being considered endoscopically to be high confidence adenomas. These findings suggest that pathology interpretation is not a gold standard for lesion management when this phenomenon is observed.


Assuntos
Adenoma/patologia , Competência Clínica , Pólipos do Colo/patologia , Colonoscopia/métodos , Neoplasias Colorretais/patologia , Erros de Diagnóstico/estatística & dados numéricos , Adenoma/cirurgia , Biópsia , Pólipos do Colo/cirurgia , Neoplasias Colorretais/cirurgia , Diagnóstico Diferencial , Humanos , Fotografação , Manejo de Espécimes
7.
Gastrointest Endosc ; 90(1): 96-100, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30465771

RESUMO

BACKGROUND AND AIMS: Serrated polyposis syndrome (SPS) increases colorectal cancer risk. We describe the numbers of colonoscopies and polypectomies performed to achieve and maintain low polyp burdens, and the feasibility of expanding surveillance intervals in patients who achieve endoscopic control. METHODS: We retrospectively evaluated a prospectively collected database on 115 patients with SPS undergoing surveillance at Indiana University Hospital between June 2005 and May 2018. The endoscopist provided surveillance interval recommendations based on polyp burden. Endoscopic control was considered successful if surveillance examinations exhibited fewer polyps and if no or only an occasional polyp ≥1 cm in size was present at follow-up. Initial control was designated as the clearing phase and the maintenance phase was surveillance after control was established. RESULTS: In total, 87 patients (75.7%) achieved endoscopic control, with some others currently in the clearing phase. Achieving control required a mean of 2.84 colonoscopies (including the baseline) over 20.4 months and a mean total of 27.9 polyp resections. After establishing control, 71 patients were recommended to receive ≥24-month follow-up. Of those, 60 patients (69.0% of patients with initial control) continued surveillance at our center. The mean interval between colonoscopies during maintenance was 19.3 months with 6.74 mean polypectomies per procedure on polyps primarily <1 cm. There were no incident cancers or colon surgeries during maintenance. CONCLUSION: Most patients achieved control of polyp burden with 2 to 3 colonoscopies over 1 to 2 years. After reaching control, 60 patients returned at intervals up to 24 months with no incident cancers and no surgeries required. Expansion of surveillance intervals to 24 months is effective and safe for many patients with SPS who reach control of polyp burden.


Assuntos
Pólipos Adenomatosos/cirurgia , Pólipos do Colo/cirurgia , Colonoscopia/métodos , Neoplasias Colorretais/cirurgia , Ressecção Endoscópica de Mucosa , Pólipos Adenomatosos/patologia , Assistência ao Convalescente , Idoso , Pólipos do Colo/patologia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Detecção Precoce de Câncer , Estudos de Viabilidade , Feminino , Humanos , Hiperplasia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Síndrome , Carga Tumoral
8.
Gastrointest Endosc ; 89(3): 591-598, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30367879

RESUMO

BACKGROUND AND AIMS: Although water exchange may improve adenoma detection compared with CO2, it is unclear whether water is a better medium to fill the lumen during withdrawal and visualize the mucosa. Total underwater colonoscopy (TUC) involves the use of water exchange with the air valve off during insertion followed by the inspection of the mucosa under water. Our goal was to compare miss rates for TUC with standard CO2 for polyps and adenomas using a tandem colonoscopy design. METHODS: We randomized participants to undergo tandem colonoscopies using TUC or CO2 first. In TUC, water exchange was performed during insertion, and withdrawal was performed under water. For the CO2 colonoscopy, both insertion and withdrawal were performed with CO2. The main outcomes were miss rates for polyps and adenomas for the first examination calculated as the number of additional polyps/adenomas detected during the second examination divided by the total number of polyps/adenomas detected for both examinations. Inspection times were calculated by subtracting the time for polypectomy, and care was taken to keep the times equal for both examinations. RESULTS: A total of 121 participants were randomized with 61 having CO2 first. The overall miss rate for polyps was higher for the TUC-first group (81/237; 34%) compared with the CO2-first cohort (57/264; 22%) (P = .002). In addition, the overall miss rate for all adenomas was higher for the TUC-first group (52/146; 36%) compared with the CO2 group (37/159; 23%) (P = .025). However, 1 of the 3 endoscopists had higher polyp/adenoma miss rates for CO2, but these were not statistically significant differences. The insertion time was longer for TUC than for CO2. After adjusting for times, participant characteristics, and bowel preparation, the miss rate for polyps was higher for TUC than for CO2. CONCLUSIONS: We found that TUC had an overall higher polyp and adenoma miss rate than colonoscopy performed with CO2, and TUC took longer to perform. However, TUC may benefit some endoscopists, an issue that requires further study. (Clinical trial registration number: NCT03231917.).


Assuntos
Adenoma/diagnóstico , Dióxido de Carbono , Pólipos do Colo/diagnóstico , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Erros de Diagnóstico/estatística & dados numéricos , Água , Idoso , Feminino , Humanos , Insuflação , Masculino , Pessoa de Meia-Idade
9.
Clin Transl Gastroenterol ; 9(8): 174, 2018 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-30093661

RESUMO

BACKGROUND: Efficiency is an important aspect of endoscopic practice that has received limited study. We evaluated the impact of scribing electronic pre-procedure history and physical examinations, and electronic procedure reports on endoscopist efficiency. METHODS: We used a stopwatch to measure the time between the procedures (scope out to scope in), pre-procedure patient assessment time, and procedure report generation time for 180 consecutive procedures performed by a single endoscopist with or without a scribe for recording history and physical and procedure reports. Schedulers were unaware of whether a scribe would be present. RESULTS: Mean times for recording the pre-procedure history and physical and procedure reports were reduced by 34% (p = 0.001) and 71% (p < 0.0001), respectively, when scribes were used. The mean time saved by the endoscopist from scribing the history and the physical and procedure reports was 2.12 and 1.59 min, respectively. When both processes were scribed, the endoscopist spent 42% (p = 0.033) longer in the recovery area (absolute mean increase 1.01 min) compared with when no scribes were utilized. The total time saved per 6.5-h procedure block with both scribes averaged to 41.7 min. CONCLUSION: The use of scribes to record history and physical examination notes and procedure reports saved enough endoscopist time to allow additional procedures or longer procedures, or to free the time for other tasks.


Assuntos
Eficiência Organizacional , Registros Eletrônicos de Saúde/organização & administração , Endoscopia Gastrointestinal/métodos , Anamnese/métodos , Exame Físico/métodos , Humanos , Estudo de Prova de Conceito , Fatores de Tempo
10.
Endoscopy ; 47(3): 245-50, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25590185

RESUMO

BACKGROUND AND STUDY AIMS: The adenoma detection rate (ADR) and adenomas detected per colonoscopy (APC) are measures of the quality of mucosal inspection during colonoscopy. In a resect and discard policy, pathologic assessment for calculation of ADR and APC would not be available. The aim of this study was to determine whether ADR and APC calculation based on photography alone is adequate compared with the pathology-based gold standard. PATIENTS AND METHODS: A prospective, observational, proof-of-concept study was performed in an academic endoscopy unit. High definition photographs of consecutive polyps were taken, and pathology was estimated by the colonoscopist. Among 121 consecutive patients aged ≥ 50 years who underwent colonoscopy, 268 polyps were removed from 97 patients. Photographs of consecutive polyps were reviewed by a second endoscopist. RESULTS: The resect and discard policy applied to lesions that were ≤ 5 mm in size. When only photographs of lesions that were ultimately proven to be adenomas were included, the reviewer assessed ADR and APC to be lower than that determined by pathology (absolute reductions of 6.6 % and 0.17, and relative reductions of 12.6 % and 13.1 % in ADR and APC, respectively). When all photographs were included for calculation of ADR and APC, the reviewer determined the ADR to be 3.3 % lower (absolute reduction) and the APC to be the same as the rates determined by pathology. CONCLUSIONS: In a simulated resect and discard strategy, a high-level detector can document adequate ADR and APC by photography alone.


Assuntos
Adenoma/patologia , Colonoscopia/normas , Neoplasias Colorretais/patologia , Fotografação , Adenoma/cirurgia , Neoplasias Colorretais/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Carga Tumoral
11.
Gastrointest Endosc ; 81(3): 525-30, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24998464

RESUMO

BACKGROUND: Rates of adequate bowel preparation in the 60% to 80% range continue to be reported for colonoscopy. OBJECTIVE: To describe the rate of adequate bowel preparation and intraprocedural work needed to achieve this rate in an open-access endoscopy unit. Universal split dosing and regimens tailored to medical predictors of inadequate preparation were used. DESIGN: Prospective observational study. SETTING: Academic hospital outpatient endoscopy unit and ambulatory surgery center. PATIENTS: Outpatients undergoing colonoscopy. INTERVENTIONS: Prospective assessment of preparation quality for colonoscopy during insertion and after intraprocedural cleansing in 525 patients. MAIN OUTCOME MEASUREMENTS: Rates of adequate preparation and work required to improve cleansing quality. Work time for cleaning was measured with a stopwatch. RESULTS: Adequate preparation to allow recommendation of standard screening or surveillance intervals was achieved in 96% of patients, including 6% for whom preparation was adequate only after intraprocedural cleansing work. The mean time for intraprocedural cleaning was 4.1 minutes and constituted 17% of total procedure time. Work time for cleaning and fluid volume injected increased when worse preparation grades were identified before cleaning. LIMITATIONS: Single-center study with low percentage (4%) of patients receiving Medicaid. CONCLUSION: An open-access unit using split-dose bowel cleansing preparations can achieve high rates of adequate bowel preparation for colonoscopy. Intraprocedural cleansing accounts for a substantial fraction of the total procedure time in colonoscopy and is an important contributor to high rates of adequate preparation.


Assuntos
Colonoscopia/métodos , Adulto , Idoso , Catárticos , Colonoscopia/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Irrigação Terapêutica , Fatores de Tempo
12.
Endoscopy ; 46(3): 172-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24500976

RESUMO

BACKGROUND AND STUDY AIMS: A newer colonoscope series has optical magnification and improvement in image freezing function. We aimed to assess the impact on image capture, image quality, and polyp discrimination. PATIENTS AND METHODS: In consecutive patients undergoing outpatient colonoscopy images of colorectal polyps were taken with Olympus 190 or 180 series instruments. The number of image captures needed to obtain an adequate image, quality of stored images, proportion of polyps with a high confidence estimate of likely histology, and accuracy of interpretations were compared. RESULTS: An acceptable image at the first attempt was obtained in 97.3 % of photos with the 190 device vs. 83.8 % with the 180 instrument (P < 0.001). In the 190 group narrowband imaging (NBI) provided high confidence readings in 9 % more cases than in the 180 group, but did not improve accuracy of polyp categorization. The quality of the stored images was judged better for the 190 device. However, when images that had provided high confidence estimates of polyp histology were re-interpreted later by the original endoscopist, there was agreement with the original interpretation for > 98 % of polyps in both the 180 group and the 190 group. A second endoscopist agreed with the original high confidence interpretations for 90 % of polyps imaged with either the 180 or the 190 scope. CONCLUSION: The new colonoscope had less image blurring, improved subjective quality of stored images, and increased the proportion of high confidence endoscopic estimates of polyp histology, but did not improve accuracy in estimating polyp histology.


Assuntos
Pólipos do Colo/patologia , Colonoscopia/instrumentação , Aumento da Imagem/instrumentação , Imagem de Banda Estreita/instrumentação , Doenças Retais/patologia , Colonoscópios , Humanos , Aumento da Imagem/normas , Imagem de Banda Estreita/normas , Variações Dependentes do Observador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...