Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Radiol Med ; 123(3): 185-190, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29086381

RESUMO

PURPOSE: To determine the frequency of unindicated CT phases and the resultant excess of absorbed radiation doses to the uterus and ovaries in women of reproductive age who have undergone CT for non-traumatic abdomino-pelvic emergencies. MATERIALS AND METHODS: We reviewed all abdomino-pelvic CT examinations in women of reproductive age (40 years or less), between 1 June 2012 and 31 January 2015. We evaluated the appropriateness of each CT phase on the basis of clinical indications, according to ACR appropriateness criteria and evidence-based data from the literature. The doses to uterus and ovaries for each phase were calculated with the CTEXPO software, taking into consideration the size-specific dose estimate (SSDE) after measuring the size of every single patient. RESULTS: The final cohort was composed of 76 female patients with an average age of 30 (from 19 to 40 years). In total, 197 CT phases were performed with an average of 2.6 phases per patient. Out of these, 93 (47%) were unindicated with an average of 1.2 inappropriate phases per patient. Unindicated scans were most frequent for appendicitis and unlocalized abdominal pain. The excesses of mean radiation doses to the uterus and ovaries due to unindicated phases were, respectively, of 38 and 33 mSv per patient. CONCLUSION: In our experience, unindicated additional CT phases were numerous with a significant excess radiation dose without an associated clinical benefit. This excess of radiation could have been avoided by widespread adoption of the ACR appropriateness criteria and evidence-based data from the literature.


Assuntos
Abdome/diagnóstico por imagem , Dor Abdominal/diagnóstico por imagem , Apendicite/diagnóstico por imagem , Emergências , Pelve/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Procedimentos Desnecessários , Adulto , Medicina Baseada em Evidências , Feminino , Humanos , Valor Preditivo dos Testes , Doses de Radiação , Efeitos da Radiação , Radiografia Abdominal , Estudos Retrospectivos , Medição de Risco , Sensibilidade e Especificidade , Procedimentos Desnecessários/efeitos adversos
2.
Radiol Med ; 123(3): 168-173, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29086382

RESUMO

PURPOSE: A strong association between breast arterial calcifications (BAC) and cardiovascular disease has been demonstrated. However, BAC quantification tools are lacking. We evaluated the intra- and inter-observer reproducibility of a semi-automatic tool for BAC quantification on digital mammograms. MATERIALS AND METHODS: A multivendor image dataset of 212 mammographic views, 106 cranio-caudal (CC) and 106 medio-lateral oblique (MLO), were retrospectively selected from 53 subjects if BAC were seen in at least one view. Images were segmented twice by two intensively trained residents in Radiodiagnostics with > 6-month experience in mammography using a semi-automatic software. The two observers (O1, O2) independently positioned rectangular ROIs where they recognized BAC on both CC and MLO views, separately. The adaptive thresholding algorithm automatically provided the BAC amount in mm2. Number, size, and position of the ROIs were observer-dependent. Total BAC amount was calculated for each patient. Bland-Altman analysis was used. RESULTS: Total BAC amount was 56.6 (IQR 18.1-91.1) and 41.0 (IQR 18.8-90.9) for O1 and O2, respectively. Intra-observer Bland-Altman analysis showed a bias of 11.9 mm2, a coefficient of repeatability of 32.7 mm2, an average measurement of 72.8 mm2, for a 55% reproducibility; the same data were - 7.0, 61.4, 63.4 mm2, and only 3%, respectively, for the inter-observer analysis. CONCLUSION: Our semi-automatic tool for BAC quantification showed a poor reproducibility. These results pointed out that the human identification of BAC represents the main source of variability. Further research is needed to translate BAC quantification into clinical practice.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Mama/irrigação sanguínea , Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Mamografia , Doenças Mamárias/complicações , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Mamografia/métodos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
3.
Radiol Med ; 121(9): 711-8, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27230670

RESUMO

OBJECTIVES: To conduct a review of literature to summarize the existing MRI protocols for penile trauma, suggesting a tailored protocol to reduce costs and time of examination. MATERIALS AND METHODS: A systematic search was performed in Medline, Embase, Cochrane Library, and Cinahl databases from 1995 to 2015 to identify studies evaluating penis trauma with MRI examination. Studies were included if there was the description of MRI protocol with at least sequences and orthogonal planes used. We chose a systematic approach for data extraction and descriptive synthesis. RESULTS: 12 articles were included in our study. Among the list of 12 articles: 2 were case reports, 3 were clinical series, and 7 were reviews. Clinical trials were not found. There is no unanimous consensus among the authors. Summarizing the data, the most used protocol is characterized by T2 sequences in three orthogonal planes plus T1 sequences in one plane (either axial or sagittal) without contrast medium injection. CONCLUSION: There is a lack of a standard protocol. A tailored protocol to answer the diagnostic question, reducing costs and time of examination, is characterized by T2 sequences in three orthogonal planes plus at least a T1 sequence (either axial or sagittal plane).


Assuntos
Imageamento por Ressonância Magnética/métodos , Pênis/lesões , Humanos , Masculino , Ruptura/diagnóstico por imagem
4.
Radiol Med ; 119(11): 852-60, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24700152

RESUMO

PURPOSE: The authors assessed the adequacy and sensitivity of CT-guided bone biopsy in 308 procedures performed in 286 cancer patients with suspected bone metastases. MATERIALS AND METHODS: An electronic search of our CT-guided bone biopsy database was retrospectively performed to evaluate the adequacy of samples and, in the event of negative samples, whether the patients had radiological progression at the site of biopsy (false negative). Adequacy and false-negative rate were compared with radiological features, biopsy location, specimen length and complications to assess any statistically relevant association with a multivariate logistic regression model. RESULTS: A total of 290/308 (94.1 %) samples were adequate. Forty-five patients had normal bone marrow and were followed-up, with evidence of progression at the site of biopsy in 10 cases (false-negative cases); overall sensitivity was 96.7 %. Specimen length was significantly correlated to the probability of an adequate biopsy (p = 0.035) and inversely correlated to the probability to obtain a false-negative result (p = 0.02). We encountered 11/308 (3.5 %) minor complications and no major complications. CONCLUSION: CT-guided biopsy of bone lesions in cancer patients allows for a final diagnosis in 94 % of cases. A specimen longer than 1 cm may lead to a significant result in terms of adequacy and sensitivity. Negative biopsies with positive positron emission tomography or magnetic resonance imaging and specimen shorter than 1 cm should be repeated to avoid a false-negative result.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/patologia , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/patologia , Tomografia Computadorizada por Raios X , Adulto , Idoso , Biópsia por Agulha/métodos , Neoplasias Ósseas/secundário , Feminino , Humanos , Biópsia Guiada por Imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
Eur J Radiol ; 83(5): 858-64, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24581810

RESUMO

OBJECTIVES: This study compared the MR measurement of minimum uninvolved cervical stroma and maximum stromal invasion, and the detection of positive lymph nodes with the pathological results. In addition, tumour type and grade were correlated with nodal status and apparent diffusion coefficient (ADC) values. METHODS: Patients who underwent surgery and MR at our centre for early stage cervical cancer (FIGO IA1-IIB) were included. Data recorded included: age, date of MR, clinical FIGO (International Federation of Gynacology and Obstetrics) stage, histological type and grade, adjuvant therapy, pre-surgical conisation. MR evaluation included: measurement of the minimum uninvolved stroma, maximum thickness of stromal involvement, presence and site of positive pelvic lymph nodes, calculation of ADC values. Statistical analysis was performed to compare MR and pathological results. The agreement between MR and pathology in measuring depth of stromal invasion was analysed by Bland-Altman plot, calculating the limits of agreement (LoA). RESULTS: 113/217 patients underwent adjuvant therapies. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of MR in evaluation of minimum thickness of uninvolved cervical stroma were 88%, 75%, 70%, 90% and 80%; the same values in evaluation of pelvic positive lymph nodes were 64%, 85%, 65%, 84% and 78%. The mean difference between MR and pathological results in measuring maximum depth of stromal invasion was -0.65mm (95% LoA: -9.37mm; 8.07mm). Depth of stromal invasion was strongly related to positive nodal status (p<0.001). ADC values (available in 51/217 patients) were not associated with the features assessed. CONCLUSIONS: Pre-surgical MR is accurate (80%) in evaluating the minimum thickness of uninvolved cervical stroma; MR measurements of maximum depth of stromal invasion differed ±9mm from the pathological results in 95% of cases. Furthermore, a strong association was found between the depth of stromal invasion and the presence of positive lymph nodes, suggesting that inclusion of these measurements in the MR report might guide the choice of the best treatment option for early cervical cancer patients.


Assuntos
Quimioterapia Adjuvante , Linfonodos/patologia , Imageamento por Ressonância Magnética/métodos , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/terapia , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Metástase Linfática , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Cuidados Pré-Operatórios , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...