Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Small ; 16(34): e2002035, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32700460

RESUMO

"After a certain high level of technical skill is achieved, science and art tend to coalesce in aesthetics, plasticity, and form. The greatest scientists are always artists as well." said Albert Einstein. Currently, photographic images bridge the gap between microfluidic/lab-on-a-chip devices and art. However, the microfluidic chip itself should be a form of art. Here, novel vibrant epoxy dyes are presented in combination with a simple process to fill and preserve microfluidic chips, to produce microfluidic art or art-on-a-chip. In addition, this process can be used to produce epoxy dye patterned substrates that preserve the geometry of the microfluidic channels-height within 10% of the mold master. This simple approach for preserving microfluidic chips with vibrant, colorful, and long-lasting epoxy dyes creates microfluidic chips that can easily be visualized and photographed repeatedly, for at least 11 years, and hence enabling researchers to showcase their microfluidic chips to potential graduate students, investors, and collaborators.

2.
PLoS One ; 8(10): e78194, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24205153

RESUMO

Evaluation of pleural fluids for metastatic cells is a key component of diagnostic cytopathology. However, a large background of smaller leukocytes and/or erythrocytes can make accurate diagnosis difficult and reduce specificity in identification of mutations of interest for targeted anti-cancer therapies. Here, we describe an automated microfluidic system (Centrifuge Chip) which employs microscale vortices for the size-based isolation and concentration of cancer cells and mesothelial cells from a background of blood cells. We are able to process non-diluted pleural fluids at 6 mL/min and enrich target cells significantly over the background; we achieved improved purity in all patient samples analyzed. The resulting isolated and viable cells are readily available for immunostaining, cytological analysis, and detection of gene mutations. To demonstrate the utility towards aiding companion diagnostics, we also show improved detection accuracy of KRAS gene mutations in lung cancer cells processed using the Centrifuge Chip, leading to an increase in the area under the curve (AUC) of the receiver operating characteristic from 0.90 to 0.99. The Centrifuge Chip allows for rapid concentration and processing of large volumes of bodily fluid samples for improved cytological diagnosis and purification of cells of interest for genetic testing, which will be helpful for enhancing diagnostic accuracy.


Assuntos
Derrame Pleural Maligno/diagnóstico , Derrame Pleural Maligno/patologia , Área Sob a Curva , Biomarcadores Tumorais/genética , Epitélio/patologia , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patologia , Microfluídica/métodos , Patologia Molecular/métodos , Derrame Pleural Maligno/genética , Proteínas Proto-Oncogênicas/genética , Proteínas Proto-Oncogênicas p21(ras) , Curva ROC , Sensibilidade e Especificidade , Proteínas ras/genética
3.
Lab Chip ; 13(6): 1011-26, 2013 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-23380972

RESUMO

The cellular components of body fluids are routinely analyzed to identify disease and treatment approaches. While significant focus has been placed on developing cell analysis technologies, tools to automate the preparation of cellular specimens have been more limited, especially for body fluids beyond blood. Preparation steps include separating, concentrating, and exposing cells to reagents. Sample preparation continues to be routinely performed off-chip by technicians, preventing cell-based point-of-care diagnostics, increasing the cost of tests, and reducing the consistency of the final analysis following multiple manually-performed steps. Here, we review the assortment of biofluids for which suspended cells are analyzed, along with their characteristics and diagnostic value. We present an overview of the conventional sample preparation processes for cytological diagnosis. We finally discuss the challenges and opportunities in developing microfluidic devices for the purpose of automating or miniaturizing these processes, with particular emphases on preparing large or small volume samples, working with samples of high cellularity, automating multi-step processes, and obtaining high purity subpopulations of cells. We hope to convey the importance of and help identify new research directions addressing the vast biological and clinical applications in preparing and analyzing the array of available biological fluids. Successfully addressing the challenges described in this review can lead to inexpensive systems to improve diagnostic accuracy while simultaneously reducing overall systemic healthcare costs.


Assuntos
Líquidos Corporais/citologia , Técnicas Analíticas Microfluídicas , Líquido Amniótico/citologia , Células Sanguíneas/citologia , Células da Medula Óssea/citologia , Líquido da Lavagem Broncoalveolar/citologia , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Manejo de Espécimes , Líquido Sinovial/citologia , Urina/citologia
4.
Biomicrofluidics ; 5(2): 22206, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21918676

RESUMO

Cell isolation in designated regions or from heterogeneous samples is often required for many microfluidic cell-based assays. However, current techniques have either limited throughput or are incapable of viable off-chip collection. We present an innovative approach, allowing high-throughput and label-free cell isolation and enrichment from heterogeneous solution using cell size as a biomarker. The approach utilizes the irreversible migration of particles into microscale vortices, developed in parallel expansion-contraction trapping reservoirs, as the cell isolation mechanism. We empirically determined the critical particle∕cell diameter D(crt) and the operational flow rate above which trapping of cells∕particles in microvortices is initiated. Using this approach we successfully separated larger cancer cells spiked in blood from the smaller blood cells with processing rates as high as 7.5×10(6) cells∕s. Viable long-term culture was established using cells collected off-chip, suggesting that the proposed technique would be useful for clinical and research applications in which in vitro culture is often desired. The presented technology improves on current technology by enriching cells based on size without clogging mechanical filters, employing only a simple single-layered microfluidic device and processing cell solutions at the ml∕min scale.

5.
Lab Chip ; 11(17): 2827-34, 2011 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-21804970

RESUMO

The standard centrifuge is a laboratory instrument widely used by biologists and medical technicians for preparing cell samples. Efforts to automate the operations of concentration, cell separation, and solution exchange that a centrifuge performs in a simpler and smaller platform have had limited success. Here, we present a microfluidic chip that replicates the functions of a centrifuge without moving parts or external forces. The device operates using a purely fluid dynamic phenomenon in which cells selectively enter and are maintained in microscale vortices. Continuous and sequential operation allows enrichment of cancer cells from spiked blood samples at the mL min(-1) scale, followed by fluorescent labeling of intra- and extra-cellular antigens on the cells without the need for manual pipetting and washing steps. A versatile centrifuge-analogue may open opportunities in automated, low-cost and high-throughput sample preparation as an alternative to the standard benchtop centrifuge in standardized clinical diagnostics or resource poor settings.


Assuntos
Separação Celular/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Automação , Linhagem Celular Tumoral , Separação Celular/métodos , Centrifugação/instrumentação , Corantes Fluorescentes/química , Humanos , Técnicas Analíticas Microfluídicas/métodos , Miniaturização , Modelos Teóricos
6.
Biotechnol Bioeng ; 107(2): 302-11, 2010 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-20589838

RESUMO

Cell separation is broadly useful for applications in clinical diagnostics, biological research, and potentially regenerative medicine. Recent attention has been paid to label-free size-based techniques that may avoid the costs or clogging issues associated with centrifugation and mechanical filtration. We present for the first time a massively parallel microfluidic device that passively separates pathogenic bacteria cells from diluted blood with macroscale performance. The device was designed to process large sample volumes in a high-throughput, continuous manner using 40 single microchannels placed in a radial array with one inlet and two rings of outlets. Each single channel consists of a short focusing, gradual expansion and collection region and uses unique differential transit times due to size-dependent inertial lift forces as a method of cell separation. The gradual channel expansion region is shown to manipulate cell equilibrium positions close to the microchannel walls, critical for higher efficiency collection. We demonstrate >80% removal of pathogenic bacteria from blood after two passes of the single channel system. The massively parallel device can process 240 mL/h with a throughput of 400 million cells/min. We expect that this parallelizable, robust, and label-free approach would be useful for filtration of blood as well as for other cell separation and concentration applications from large volume samples.


Assuntos
Bactérias/isolamento & purificação , Sangue , Separação Celular/métodos , Equipamentos e Provisões , Filtração/métodos , Microfluídica/métodos
7.
Anal Bioanal Chem ; 397(8): 3249-67, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20419490

RESUMO

Cell separation and sorting are essential steps in cell biology research and in many diagnostic and therapeutic methods. Recently, there has been interest in methods which avoid the use of biochemical labels; numerous intrinsic biomarkers have been explored to identify cells including size, electrical polarizability, and hydrodynamic properties. This review highlights microfluidic techniques used for label-free discrimination and fractionation of cell populations. Microfluidic systems have been adopted to precisely handle single cells and interface with other tools for biochemical analysis. We analyzed many of these techniques, detailing their mode of separation, while concentrating on recent developments and evaluating their prospects for application. Furthermore, this was done from a perspective where inertial effects are considered important and general performance metrics were proposed which would ease comparison of reported technologies. Lastly, we assess the current state of these technologies and suggest directions which may make them more accessible.


Assuntos
Separação Celular/métodos , Células/citologia , Técnicas Analíticas Microfluídicas/métodos , Animais , Separação Celular/instrumentação , Células/química , Humanos , Técnicas Analíticas Microfluídicas/instrumentação
8.
J Biol Chem ; 283(17): 11596-605, 2008 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-18292092

RESUMO

The bacterial adhesive protein, FimH, is the most common adhesin of Escherichia coli and mediates weak adhesion at low flow but strong adhesion at high flow. There is evidence that this occurs because FimH forms catch bonds, defined as bonds that are strengthened by tensile mechanical force. Here, we applied force to single isolated FimH bonds with an atomic force microscope in order to test this directly. If force was loaded slowly, most of the bonds broke up at low force (<60 piconewtons of rupture force). However, when force was loaded rapidly, all bonds survived until much higher force (140-180 piconewtons of rupture force), behavior that indicates a catch bond. Structural mutations or pretreatment with a monoclonal antibody, both of which allosterically stabilize a high affinity conformation of FimH, cause all bonds to survive until high forces regardless of the rate at which force is applied. Pretreatment of FimH bonds with intermediate force has the same strengthening effect on the bonds. This demonstrates that FimH forms catch bonds and that tensile force induces an allosteric switch to the high affinity, strong binding conformation of the adhesin. The catch bond behavior of FimH, the amount of force needed to regulate FimH, and the allosteric mechanism all provide insight into how bacteria bind and form biofilms in fluid flow. Additionally, these observations may provide a means for designing antiadhesive mechanisms.


Assuntos
Adesinas de Escherichia coli/química , Escherichia coli/metabolismo , Proteínas de Fímbrias/fisiologia , Regulação Bacteriana da Expressão Gênica , Adesinas Bacterianas/química , Adesinas de Escherichia coli/fisiologia , Regulação Alostérica , Sítio Alostérico , Aderência Bacteriana , Proteínas de Fímbrias/química , Cinética , Microscopia de Força Atômica , Modelos Biológicos , Modelos Químicos , Conformação Molecular , Conformação Proteica , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...