Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Acoust Soc Am ; 150(3): 1934, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34598651

RESUMO

Learning about new sounds is essential for cochlear-implant and normal-hearing listeners alike, with the additional challenge for implant listeners that spectral resolution is severely degraded. Here, a task measuring the rapid learning of slow or fast stochastic temporal sequences [Kang, Agus, and Pressnitzer (2017). J. Acoust. Soc. Am. 142, 2219-2232] was performed by cochlear-implant (N = 10) and normal-hearing (N = 9) listeners, using electric or acoustic pulse sequences, respectively. Rapid perceptual learning was observed for both groups, with highly similar characteristics. Moreover, for cochlear-implant listeners, an additional condition tested ultra-fast electric pulse sequences that would be impossible to represent temporally when presented acoustically. This condition also demonstrated learning. Overall, the results suggest that cochlear-implant listeners have access to the neural plasticity mechanisms needed for the rapid perceptual learning of complex temporal sequences.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Estimulação Acústica , Acústica , Testes Auditivos
2.
Hear Res ; 403: 108176, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33524792

RESUMO

While electrically-evoked auditory brainstem response (eABR) thresholds for low-rate pulse trains correlate well with behavioral thresholds measured at the same rate, the correlation is much weaker with behavioral thresholds measured at high rates, such as used clinically. This implies that eABRs to low-rate stimuli cannot be reliably used for objective programming of threshold levels in cochlear implant (CI) users. Here, we investigate whether the use of bunched-up pulses (BUPS), consisting of groups of closely-spaced pulses may be used as an alternative stimulus. Experiment 1 measured psychophysical detection thresholds for several stimuli having a period of 32 ms in nine CI subjects implanted with a Med-EL device. The stimuli differed in the number of pulses present in each period (from 1 to 32), the pulse rate within period (1000 pps and as high as possible for BUPS) and the electrode location (apical or basal). The correlation between psychophysical thresholds obtained for a high-rate (1000 pps) clinical stimulus and for the BUPS stimuli increased as the number of pulses per period of BUPS increased from 1 to 32. This first psychophysical experiment suggests that the temporal processes affecting the threshold of clinical stimuli are also present for BUPS. Experiment 2 measured eABRs on the apical electrode of eight CI subjects for BUPS having 1, 2, 4, 8, 16 or 32 pulses per period. For most subjects, wave V was visible for BUPS having up to 16 pulses per period. The latency of wave V at threshold increased as a function of the number of pulses per period, suggesting that the eABR reflects the integration of multiple pulses at such low levels or that the neural response to each individual pulse increases along the sequence due to facilitation processes. There was also a strong within-subject correlation between electrophysiological and behavioral thresholds for the different BUPS stimuli. This demonstrates that the drop in behavioral threshold obtained when increasing the number of pulses per period of the BUPS can be measured electrophysiologically using eABRs. In contrast, the across-subject correlation between eABR thresholds for BUPS and clinical thresholds remained relatively weak and did not increase with the number of pulses per period. Implications of the use of BUPS for objective programming of CIs are discussed.


Assuntos
Implante Coclear , Implantes Cocleares , Limiar Auditivo , Estimulação Elétrica , Potenciais Evocados Auditivos do Tronco Encefálico , Frequência Cardíaca , Humanos
3.
J Speech Lang Hear Res ; 64(1): 196-205, 2021 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-33267729

RESUMO

Purpose An increasing number of individuals with residual or even normal contralateral hearing are being considered for cochlear implantation. It remains unknown whether the presence of contralateral hearing is beneficial or detrimental to their perceptual learning of cochlear implant (CI)-processed speech. The aim of this experiment was to provide a first insight into this question using acoustic simulations of CI processing. Method Sixty normal-hearing listeners took part in an auditory perceptual learning experiment. Each subject was randomly assigned to one of three groups of 20 referred to as NORMAL, LOWPASS, and NOTHING. The experiment consisted of two test phases separated by a training phase. In the test phases, all subjects were tested on recognition of monosyllabic words passed through a six-channel "PSHC" vocoder presented to a single ear. In the training phase, which consisted of listening to a 25-min audio book, all subjects were also presented with the same vocoded speech in one ear but the signal they received in their other ear differed across groups. The NORMAL group was presented with the unprocessed speech signal, the LOWPASS group with a low-pass filtered version of the speech signal, and the NOTHING group with no sound at all. Results The improvement in speech scores following training was significantly smaller for the NORMAL than for the LOWPASS and NOTHING groups. Conclusions This study suggests that the presentation of normal speech in the contralateral ear reduces or slows down perceptual learning of vocoded speech but that an unintelligible low-pass filtered contralateral signal does not have this effect. Potential implications for the rehabilitation of CI patients with partial or full contralateral hearing are discussed.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Audição , Humanos , Fala
4.
J Assoc Res Otolaryngol ; 21(1): 89-104, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32020417

RESUMO

Cochlear implant (CI) performance varies dramatically between subjects. Although the causes of this variability remain unclear, the electrode-neuron interface is thought to play an important role. Here we evaluate the contribution of two parameters of this interface on the perception of CI listeners: the electrode-to-modiolar wall distance (EMD), estimated from cone-beam computed tomography (CT) scans, and a measure of neural health. Since there is no objective way to quantify neural health in CI users, we measure stimulus polarity sensitivity, which is assumed to be related to neural degeneration, and investigate whether it also correlates with subjects' performance in speech recognition and spectro-temporal modulation detection tasks. Detection thresholds were measured in fifteen CI users (sixteen ears) for partial-tripolar triphasic pulses having an anodic or a cathodic central phase. The polarity effect was defined as the difference in threshold between cathodic and anodic stimuli. Our results show that both the EMD and the polarity effect correlate with detection thresholds, both across and within subjects, although the within-subject correlations were weak. Furthermore, the mean polarity effect, averaged across all electrodes for each subject, was negatively correlated with performance on a spectro-temporal modulation detection task. In other words, lower cathodic thresholds were associated with better spectro-temporal modulation detection performance, which is also consistent with polarity sensitivity being a marker of neural degeneration. Implications for the design of future subject-specific fitting strategies are discussed.


Assuntos
Limiar Auditivo , Cóclea/fisiologia , Implantes Cocleares , Percepção da Fala , Adulto , Idoso , Cóclea/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Humanos , Pessoa de Meia-Idade , Adulto Jovem
5.
Front Neurosci ; 13: 1119, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31736684

RESUMO

Previous studies in patients with single-sided deafness (SSD) have reported results of pitch comparisons between electric stimulation of their cochlear implant (CI) and acoustic stimulation presented to their near-normal hearing contralateral ear. These comparisons typically used sinusoids, although the percept elicited by electric stimulation may be closer to a wideband stimulus. Furthermore, it has been shown that pitch comparisons between sounds with different timbres is a difficult task and subjected to various types of range biases. The present study aims to introduce a method to minimize non-sensory biases, and to investigate the effect of different acoustic stimulus types on the frequency and variability of the electric-acoustic pitch matches. Pitch matches were collected from 13 CI users with SSD using the binary search procedure. Electric stimulation was presented at either an apical or a middle electrode position, at a rate of 800 pps. Acoustic stimulus types were sinusoids (SINE), 1/3-octave wide narrow bands of Gaussian noises (NBN), or 1/3-octave wide pulse spreading harmonic complexes (PSHC). On the one hand, NBN and PSHC are presumed to better mimic the spread of excitation produced by a single-electrode stimulation than SINE. On the other hand, SINE and PSHC contain less inherent fluctuations than NBN and may therefore provide a temporal pattern closer to that produced by a constant-amplitude electric pulse train. Analysis of mean pitch match variance showed no differences between stimulus types. However, mean pitch matches showed effects of electrode position and stimulus type, with the middle electrode always matched to a higher frequency than the apical one (p < 0.001), and significantly higher across-subject pitch matches for PSHC compared with SINE (p = 0.017). Mean pitch matches for all stimulus types were better predicted by place-dependent characteristic frequencies (CFs) based on an organ of Corti map compared with a spiral ganglion map. CF predictions were closest to pitch matches with SINE for the apical electrode position, and conversely with NBN or PSHC for the middle electrode position. These results provide evidence that the choice of acoustic stimulus type can have a significant effect on electric-acoustic pitch matching.

6.
Trends Hear ; 23: 2331216519866029, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31533581

RESUMO

Cochlear implantation in subjects with single-sided deafness (SSD) offers a unique opportunity to directly compare the percepts evoked by a cochlear implant (CI) with those evoked acoustically. Here, nine SSD-CI users performed a forced-choice task evaluating the similarity of speech processed by their CI with speech processed by several vocoders presented to their healthy ear. In each trial, subjects heard two intervals: their CI followed by a certain vocoder in Interval 1 and their CI followed by a different vocoder in Interval 2. The vocoders differed either (i) in carrier type-(sinusoidal [SINE], bandfiltered noise [NOISE], and pulse-spreading harmonic complex) or (ii) in frequency mismatch between the analysis and synthesis frequency ranges-(no mismatch, and two frequency-mismatched conditions of 2 and 4 equivalent rectangular bandwidths [ERBs]). Subjects had to state in which of the two intervals the CI and vocoder sounds were more similar. Despite a large intersubject variability, the PSHC vocoder was judged significantly more similar to the CI than SINE or NOISE vocoders. Furthermore, the No-mismatch and 2-ERB mismatch vocoders were judged significantly more similar to the CI than the 4-ERB mismatch vocoder. The mismatch data were also interpreted by comparing spiral ganglion characteristic frequencies with electrode contact positions determined from postoperative computed tomography scans. Only one subject demonstrated a pattern of preference consistent with adaptation to the CI sound processor frequency-to-electrode allocation table and two subjects showed possible partial adaptation. Those subjects with adaptation patterns presented overall small and consistent frequency mismatches across their electrode arrays.


Assuntos
Implante Coclear/métodos , Implantes Cocleares/normas , Perda Auditiva Unilateral/reabilitação , Adulto , Surdez/reabilitação , Feminino , Humanos , Masculino , Som , Fala , Percepção da Fala/fisiologia , Gânglio Espiral da Cóclea
7.
J Neural Eng ; 16(1): 016023, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30523898

RESUMO

The performance of cochlear implant (CI) listeners is limited by several factors among which the lack of spatial selectivity of the electrical stimulation. Recently, many studies have explored the use of multipolar strategies where several electrodes are stimulated simultaneously to focus the electrical field in a restricted region of the cochlea. OBJECTIVE: These strategies are based on several assumptions concerning the electrical properties of the inner ear that need validation. The first, often implicit, assumption is that the medium is purely resistive and that the current waveforms produced by several electrodes sum linearly. The second assumption relates to the estimation of the contribution of each electrode to the overall electrical field. These individual contributions are usually obtained by stimulating each electrode and measuring the resulting voltage with the other inactive electrodes (i.e. the impedance matrix). However, measuring the voltage on active electrodes (i.e. the diagonal of the matrix) is not straightforward because of the polarization of the electrode-fluid interface. In existing multipolar strategies, the diagonal terms of the matrix are therefore inferred using linear extrapolation from measurements made at neighboring electrodes. APPROACH: In experiment 1, several impedance measurements were carried out in vitro and in eight CI users using sinusoidal and pulsatile waveforms to test the resistivity and linearity hypotheses. In experiment 2, we used an equivalent electrical model including a constant phase element in order to isolate the polarization component of the contact impedance. MAIN RESULTS: In experiment 1, high-resolution voltage recordings (1.1 MHz sampling) showed the resistivity assumption to be valid at 46.4 kHz, the highest frequency tested. However, these measures also revealed the presence of parasitic capacitive effects at high frequency that could be deleterious to multipolar strategies. Experiment 2 showed that the electrical model provides a better account of the high-resolution impedance measurements than previous approaches in the CI field that used resistor-capacitance circuit models. SIGNIFICANCE: These results validate the main hypotheses underlying the use of multipolar stimulation but also suggest possible modifications to their implementation, including the use of an impedance model and the modification of the electrical pulse waveform.


Assuntos
Surdez/fisiopatologia , Surdez/terapia , Orelha Interna/fisiopatologia , Impedância Elétrica/uso terapêutico , Terapia por Estimulação Elétrica/métodos , Eletrodos Implantados , Adulto , Idoso , Idoso de 80 Anos ou mais , Implantes Cocleares , Estimulação Elétrica/instrumentação , Estimulação Elétrica/métodos , Terapia por Estimulação Elétrica/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
J Assoc Res Otolaryngol ; 18(5): 711-727, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28755309

RESUMO

Three experiments studied the extent to which cochlear implant users' spatial selectivity can be manipulated using asymmetric waveforms and tested an efficient method for comparing spatial selectivity produced by different stimuli. Experiment 1 measured forward-masked psychophysical tuning curves (PTCs) for a partial tripolar (pTP) probe. Maskers were presented on bipolar pairs separated by one unused electrode; waveforms were either symmetric biphasic ("SYM") or pseudomonophasic with the short high-amplitude phase being either anodic ("PSA") or cathodic ("PSC") on the more apical electrode. For the SYM masker, several subjects showed PTCs consistent with a bimodal excitation pattern, with discrete excitation peaks on each electrode of the bipolar masker pair. Most subjects showed significant differences between the PSA and PSC maskers consistent with greater masking by the electrode where the high-amplitude phase was anodic, but the pattern differed markedly across subjects. Experiment 2 measured masked excitation patterns for a pTP probe and either a monopolar symmetric biphasic masker ("MP_SYM") or pTP pseudomonophasic maskers where the short high-amplitude phase was either anodic ("TP_PSA") or cathodic ("TP_PSC") on the masker's central electrode. Four of the five subjects showed significant differences between the masker types, but again the pattern varied markedly across subjects. Because the levels of the maskers were chosen to produce the same masking of a probe on the same channel as the masker, it was correctly predicted that maskers that produce broader masking patterns would sound louder. Experiment 3 exploited this finding by using a single-point measure of spread of excitation to reveal significantly better spatial selectivity for TP_PSA compared to TP_PSC maskers.


Assuntos
Implantes Cocleares , Percepção da Fala , Idoso , Humanos , Percepção Sonora , Pessoa de Meia-Idade , Acústica da Fala
9.
J Assoc Res Otolaryngol ; 18(3): 513-527, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28138791

RESUMO

Most cochlear implants (CIs) activate their electrodes non-simultaneously in order to eliminate electrical field interactions. However, the membrane of auditory nerve fibers needs time to return to its resting state, causing the probability of firing to a pulse to be affected by previous pulses. Here, we provide new evidence on the effect of pulse polarity and current level on these interactions. In experiment 1, detection thresholds and most comfortable levels (MCLs) were measured in CI users for 100-Hz pulse trains consisting of two consecutive biphasic pulses of the same or of opposite polarity. All combinations of polarities were studied: anodic-cathodic-anodic-cathodic (ACAC), CACA, ACCA, and CAAC. Thresholds were lower when the adjacent phases of the two pulses had the same polarity (ACCA and CAAC) than when they were different (ACAC and CACA). Some subjects showed a lower threshold for ACCA than for CAAC while others showed the opposite trend demonstrating that polarity sensitivity at threshold is genuine and subject- or electrode-dependent. In contrast, anodic (CAAC) pulses always showed a lower MCL than cathodic (ACCA) pulses, confirming previous reports. In experiments 2 and 3, the subjects compared the loudness of several pulse trains differing in current level separately for ACCA and CAAC. For 40 % of the electrodes tested, loudness grew non-monotonically as a function of current level for ACCA but never for CAAC. This finding may relate to a conduction block of the action potentials along the fibers induced by a strong hyperpolarization of their central processes. Further analysis showed that the electrodes showing a lower threshold for ACCA than for CAAC were more likely to yield a non-monotonic loudness growth. It is proposed that polarity sensitivity at threshold reflects the local neural health and that anodic asymmetric pulses should preferably be used to convey sound information while avoiding abnormal loudness percepts.


Assuntos
Limiar Auditivo , Implantes Cocleares , Percepção Sonora , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade
10.
J Assoc Res Otolaryngol ; 18(3): 495-512, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28224320

RESUMO

Electrical stimulation of auditory nerve fibers using cochlear implants (CI) shows psychophysical forward masking (pFM) up to several hundreds of milliseconds. By contrast, recovery of electrically evoked compound action potentials (eCAPs) from forward masking (eFM) was shown to be more rapid, with time constants no greater than a few milliseconds. These discrepancies suggested two main contributors to pFM: a rapid-recovery process due to refractory properties of the auditory nerve and a slow-recovery process arising from more central structures. In the present study, we investigate whether the use of different maskers between eCAP and psychophysical measures, specifically single-pulse versus pulse train maskers, may have been a source of confound.In experiment 1, we measured eFM using the following: a single-pulse masker, a 300-ms low-rate pulse train masker (LTM, 250 pps), and a 300-ms high-rate pulse train masker (HTM, 5000 pps). The maskers were presented either at same physical current (Φ) or at same perceptual (Ψ) level corresponding to comfortable loudness. Responses to a single-pulse probe were measured for masker-probe intervals ranging from 1 to 512 ms. Recovery from masking was much slower for pulse trains than for the single-pulse masker. When presented at Φ level, HTM produced more and longer-lasting masking than LTM. However, results were inconsistent when LTM and HTM were compared at Ψ level. In experiment 2, masked detection thresholds of single-pulse probes were measured using the same pulse train masker conditions. In line with our eFM findings, masked thresholds for HTM were higher than those for LTM at Φ level. However, the opposite result was found when the pulse trains were presented at Ψ level.Our results confirm the presence of slow-recovery phenomena at the level of the auditory nerve in CI users, as previously shown in animal studies. Inconsistencies between eFM and pFM results, despite using the same masking conditions, further underline the importance of comparing electrophysiological and psychophysical measures with identical stimulation paradigms.


Assuntos
Potenciais de Ação , Adaptação Fisiológica , Implantes Cocleares , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
11.
J Acoust Soc Am ; 139(4): 1578, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-27106306

RESUMO

Temporal pitch perception in cochlear implantees remains weaker than in normal hearing listeners and is usually limited to rates below about 300 pulses per second (pps). Recent studies have suggested that stimulating the apical part of the cochlea may improve the temporal coding of pitch by cochlear implants (CIs), compared to stimulating other sites. The present study focuses on rate discrimination at low pulse rates (ranging from 20 to 104 pps). Two experiments measured and compared pulse rate difference limens (DLs) at four fundamental frequencies (ranging from 20 to 104 Hz) in both CI and normal-hearing (NH) listeners. Experiment 1 measured DLs in users of the (Med-El CI, Innsbruck, Austria) device for two electrodes (one apical and one basal). In experiment 2, DLs for NH listeners were compared for unresolved harmonic complex tones filtered in two frequency regions (lower cut-off frequencies of 1200 and 3600 Hz, respectively) and for different bandwidths. Pulse rate discrimination performance was significantly better when stimulation was provided by the apical electrode in CI users and by the lower-frequency tone complexes in NH listeners. This set of data appears consistent with better temporal coding when stimulation originates from apical regions of the cochlea.


Assuntos
Cóclea/inervação , Implante Coclear/instrumentação , Implantes Cocleares , Pessoas com Deficiência Auditiva/reabilitação , Discriminação da Altura Tonal , Estimulação Acústica/métodos , Adulto , Idoso , Estudos de Casos e Controles , Implante Coclear/métodos , Discriminação Psicológica , Estimulação Elétrica , Feminino , Humanos , Percepção Sonora , Masculino , Pessoa de Meia-Idade , Pessoas com Deficiência Auditiva/psicologia , Fatores de Tempo
12.
Adv Exp Med Biol ; 894: 133-142, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27080654

RESUMO

Most cochlear implants (CIs) stimulate the auditory nerve with trains of symmetric biphasic pulses consisting of two phases of opposite polarity. Animal and human studies have shown that both polarities can elicit neural responses. In human CI listeners, studies have shown that at suprathreshold levels, the anodic phase is more effective than the cathodic phase. In contrast, animal studies usually show the opposite trend. Although the reason for this discrepancy remains unclear, computational modelling results have proposed that the degeneration of the peripheral processes of the neurons could lead to a higher efficiency of anodic stimulation. We tested this hypothesis in ten guinea pigs who were deafened with an injection of sysomycin and implanted with a single ball electrode inserted in the first turn of the cochlea. Animals were tested at regular intervals between 1 week after deafening and up to 1 year for some of them. Our hypothesis was that if the effect of polarity is determined by the presence or absence of peripheral processes, the difference in polarity efficiency should change over time because of a progressive neural degeneration. Stimuli consisted of charge-balanced symmetric and asymmetric pulses allowing us to observe the response to each polarity individually. For all stimuli, the inferior colliculus evoked potential was measured. Results show that the cathodic phase was more effective than the anodic phase and that this remained so even several months after deafening. This suggests that neural degeneration cannot entirely account for the higher efficiency of anodic stimulation observed in human CI listeners.


Assuntos
Implantes Cocleares , Colículos Inferiores/fisiologia , Animais , Nervo Coclear/fisiologia , Estimulação Elétrica , Potenciais Evocados Auditivos , Cobaias
13.
J Acoust Soc Am ; 139(2): 986-91, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26936577

RESUMO

Noise- and sine-carrier vocoders are often used to acoustically simulate the information transmitted by a cochlear implant (CI). However, sine-waves fail to mimic the broad spread of excitation produced by a CI and noise-bands contain intrinsic modulations that are absent in CIs. The present study proposes pulse-spreading harmonic complexes (PSHCs) as an alternative acoustic carrier in vocoders. Sentence-in-noise recognition was measured in 12 normal-hearing subjects for noise-, sine-, and PSHC-vocoders. Consistent with the amount of intrinsic modulations present in each vocoder condition, the average speech reception threshold obtained with the PSHC-vocoder was higher than with sine-vocoding but lower than with noise-vocoding.


Assuntos
Implante Coclear/instrumentação , Implantes Cocleares , Pessoas com Deficiência Auditiva/reabilitação , Processamento de Sinais Assistido por Computador , Percepção da Fala , Estimulação Acústica , Estimulação Elétrica , Humanos , Ruído/efeitos adversos , Mascaramento Perceptivo , Pessoas com Deficiência Auditiva/psicologia , Reconhecimento Psicológico , Inteligibilidade da Fala , Teste do Limiar de Recepção da Fala
14.
Adv Exp Med Biol ; 894: E1, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-29978447

RESUMO

In the original version of the chapter, the labels on the x-axis of Figure 2, panels A and B were wrong. This incorrect figure has been replaced with the below figure.

15.
Hear Res ; 319: 32-47, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25449010

RESUMO

Several electrophysiological and psychophysical studies have shown that the spatial excitation pattern produced by bipolar stimulation of a cochlear implant (CI) can have a dual-peak shape. The perceptual effects of this dual-peak shape were investigated using noise-vocoded CI simulations in which synthesis filters were designed to simulate the spread of neural activity produced by various electrode configurations, as predicted by a simple cochlear model. Experiments 1 and 2 tested speech recognition in the presence of a concurrent speech masker for various sets of single-peak and dual-peak synthesis filters and different numbers of channels. Similarly as results obtained in real CIs, both monopolar (MP, single-peak) and bipolar (BP + 1, dual-peak) simulations showed a plateau of performance above 8 channels. The benefit of increasing the number of channels was also lower for BP + 1 than for MP. This shows that channel interactions in BP + 1 become especially deleterious for speech intelligibility when a simulated electrode acts both as an active and as a return electrode for different channels because envelope information from two different analysis bands are being conveyed to the same spectral location. Experiment 3 shows that these channel interactions are even stronger in wide BP configuration (BP + 5), likely because the interfering speech envelopes are less correlated than in narrow BP + 1. Although the exact effects of dual- or multi-peak excitation in real CIs remain to be determined, this series of experiments suggest that multipolar stimulation strategies, such as bipolar or tripolar, should be controlled to avoid neural excitation in the vicinity of the return electrodes.


Assuntos
Implantes Cocleares , Mascaramento Perceptivo , Inteligibilidade da Fala , Estimulação Acústica , Adulto , Implante Coclear , Simulação por Computador , Eletrodos , Feminino , Testes Auditivos , Humanos , Masculino , Processamento de Sinais Assistido por Computador , Fala , Percepção da Fala , Adulto Jovem
16.
J Acoust Soc Am ; 136(6): 3186, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25480066

RESUMO

Five normally hearing listeners pitch-ranked harmonic complexes of different fundamental frequencies (F0s) filtered in three different frequency regions. Harmonics were summed either in sine, alternating sine-cosine (ALT), or pulse-spreading (PSHC) phase. The envelopes of ALT and PSHC complexes repeated at rates of 2F0 and 4F0. Pitch corresponded to those rates at low F0s, but, as F0 increased, there was a range of F0s over which pitch remained constant or dropped. Gammatone-filterbank simulations showed that, as F0 increased and the number of harmonics interacting in a filter dropped, the output of that filter switched from repeating at 2F0 or 4F0 to repeating at F0. A model incorporating this phenomenon accounted well for the data, except for complexes filtered into the highest frequency region (7800-10 800 Hz). To account for the data in that region it was necessary to assume either that auditory filters at very high frequencies are sharper than traditionally believed, and/or that the auditory system applies smaller weights to filters whose outputs repeat at high rates. The results also provide evidence on the highest pitch that can be derived from purely temporal cues, and corroborate recent reports that a complex pitch can be derived from very-high-frequency resolved harmonics.


Assuntos
Discriminação da Altura Tonal/fisiologia , Espectrografia do Som , Percepção do Tempo/fisiologia , Estimulação Acústica , Vias Auditivas/fisiologia , Limiar Auditivo/fisiologia , Simulação por Computador , Sinais (Psicologia) , Humanos , Discriminação da Altura Tonal/classificação , Psicoacústica
17.
Int J Audiol ; 53(12): 871-9, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25358027

RESUMO

OBJECTIVE: To evaluate a speech-processing strategy in which the lowest frequency channel is conveyed using an asymmetric pulse shape and "phantom stimulation", where current is injected into one intra-cochlear electrode and where the return current is shared between an intra-cochlear and an extra-cochlear electrode. This strategy is expected to provide more selective excitation of the cochlear apex, compared to a standard strategy where the lowest-frequency channel is conveyed by symmetric pulses in monopolar mode. In both strategies all other channels were conveyed by monopolar stimulation. DESIGN: Within-subjects comparison between the two strategies. Four experiments: (1) discrimination between the strategies, controlling for loudness differences, (2) consonant identification, (3) recognition of lowpass-filtered sentences in quiet, (4) sentence recognition in the presence of a competing speaker. STUDY SAMPLE: Eight users of the Advanced Bionics CII/Hi-Res 90k cochlear implant. RESULTS: Listeners could easily discriminate between the two strategies but no consistent differences in performance were observed. CONCLUSIONS: The proposed method does not improve speech perception, at least in the short term.


Assuntos
Estimulação Acústica/instrumentação , Estimulação Acústica/métodos , Implante Coclear/métodos , Adulto , Idoso , Cóclea , Implantes Cocleares , Potenciais Microfônicos da Cóclea , Eletrodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Pulso Arterial/métodos , Percepção da Fala
18.
Curr Biol ; 24(18): R878-R884, 2014 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-25247367

RESUMO

Cochlear implants are the first example of a neural prosthesis that can substitute a sensory organ: they bypass the malfunctioning auditory periphery of profoundly-deaf people to electrically stimulate their auditory nerve. The history of cochlear implants dates back to 1957, when Djourno and Eyriès managed, for the first time, to elicit sound sensations in a deaf listener using an electrode implanted in his inner ear. Since then, considerable technological and scientific advances have been made. Worldwide, more than 300,000 deaf people have been fitted with a cochlear implant; it has become a standard clinical procedure for born-deaf children and its success has led over the years to relaxed patient selection criteria; for example, it is now not uncommon to see people with significant residual hearing undergoing implantation. Although the ability to make sense of sounds varies widely among the implanted population, many cochlear implant listeners can use the telephone and follow auditory-only conversations in quiet environments.


Assuntos
Percepção Auditiva , Implante Coclear/normas , Implantes Cocleares , Audição , Humanos
19.
J Acoust Soc Am ; 136(3): 1281, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25190401

RESUMO

All signals, except sine waves, exhibit intrinsic modulations that affect perceptual masking. Reducing the physical intrinsic modulations of a broadband signal does not necessarily have a perceptual impact: auditory filtering can reintroduce modulations. Broadband signals with low intrinsic modulations after auditory filtering have proved difficult to design. To that end, this paper introduces a class of signals termed pulse-spreading harmonic complexes (PSHCs). PSHCs are generated by summing harmonically related components with such a phase that the resulting waveform exhibits pulses equally-spaced within a repetition period. The order of a PSHC determines its pulse rate. Simulations with a gamma-tone filterbank suggest an optimal pulse rate at which, after auditory filtering, the PSHC's intrinsic modulations are lowest. These intrinsic modulations appear to be less than those for broadband pseudo-random (PR) or low-noise (LN) noise. This hypothesis was tested in a modulation-detection experiment involving five modulation rates ranging from 8 to 128 Hz and both broadband and narrowband carriers using PSHCs, PR, and LN noise. PSHC showed the lowest thresholds of all broadband signals. Results imply that optimized PSHCs exhibit less intrinsic modulations after auditory filtering than any other broadband signal previously considered.

20.
J Acoust Soc Am ; 134(1): 503-9, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23862825

RESUMO

Users of Advanced Bionics, MedEl, and Cochlear Corp. implants balanced the loudness of trains of asymmetric pulses of opposite polarities presented in monopolar mode. For the Advanced Bionics and MedEl users the pulses were triphasic and consisted of a 32-µs central phase flanked by two 32-µs phases of opposite polarity and half the amplitude. The central phase was either anodic (TP-A) or cathodic (TP-C). For the Cochlear Corp. users, pulses consisted of two 32-µs phases of the same polarity separated by an 8-µs gap, flanked by two 32-µs phases of the opposite polarity, each of which was separated from the central portion by a 58-µs gap. The central portion of these quadraphasic pulses was either anodic (QP-A) or cathodic (QP-C), and all phases had the same amplitude. The current needed to achieve matched loudness was lower for the anodic than for the cathodic stimuli. This polarity effect was similar across all electrode locations studied, including the most apical electrode of the MedEl device which stimulates the very apex of the cochlea. In addition, when quadraphasic pulses were presented in bipolar mode, listeners reported hearing a lower pitch when the central portion was anodic at the more apical, than at the more basal, electrode. The results replicate previous reports that, unlike the results of most animal studies, human cochlear implant listeners are more sensitive to anodic than to cathodic currents, and extend those findings to a wider range of cochlear sites, implant types, and pulse shapes.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Percepção Sonora , Discriminação da Altura Tonal , Desenho de Prótese , Estimulação Acústica , Adulto , Idoso , Nervo Coclear/fisiologia , Eletrodos Implantados , Feminino , Humanos , Julgamento , Percepção Sonora/fisiologia , Masculino , Pessoa de Meia-Idade , Discriminação da Altura Tonal/fisiologia , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...