Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 897
Filtrar
1.
Am J Cardiol ; 232: 1-7, 2024 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-39251079

RESUMO

The contemporary health care resource utilization after an acute myocardial infarction (MI) is not well-known. All patients admitted because of MI between January 2015 and December 2021 across 28 hospitals in the Baylor Scott & White Health system were studied. Patient characteristics and outcomes, including all-cause and cardiovascular (CV) rehospitalizations, emergency department (ED) visits, and outpatient visits were evaluated. Of 6,804 patients admitted because of MI, 6,556 were discharged alive. The median age was 69 years, 60% were men, and 77% had non-ST-elevation MI; 17% (1,090) had multivessel disease. The number of patients with first all-cause readmissions within 30 days, 3 months, and 12 months of discharge were 844 (13%), 1,372 (21%), and 2,306 (35%), respectively, with a higher readmission rate in patients with non-ST-elevation MI, previous heart failure (HF), new-onset HF, and left ventricular ejection fraction ≤40%. ED visits at 12 months for any cause were 2,401 (37%), of which 1,321 (55%) were for any CV cause, with a higher incidence in patients with previous HF. Of the 6,556 patients, 4,102 (63%) had at least 1 primary care visit in the past year, 5,009 (76%) had CV specialty visits, and 3,860 (59%) had non-CV visits, with a similar distribution across subgroups. Patients hospitalized with an MI had a high risk of subsequent hospital readmissions and ED and outpatient visits, especially those with a previous HF diagnosis and those discharged with an MI and HF diagnosis.

2.
Struct Heart ; 8(5): 100333, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39290680

RESUMO

Background: The implications of pulmonary vein (PV) flow patterns in patients with heart failure (HF) and mitral regurgitation (MR) are uncertain. We examined PV flow patterns in the Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation (COAPT) trial (NCT01626079), in which patients with HF and moderate-to-severe or severe functional MR were randomized to transcatheter edge-to-edge repair (TEER) with the MitraClip device plus guideline-directed medical therapy (GDMT) vs. GDMT alone. We sought to evaluate the prognostic utility of baseline PV systolic flow reversal (PVSFR) in HF patients with severe MR and to determine whether the presence of PVSFR can discriminate patients most likely to benefit from TEER in COAPT trial patients. Methods: Patients were categorized by the echocardiographic core laboratory-assessed baseline presence of PVSFR. Two-year outcomes were examined according to PVSFR and treatment. Results: Baseline PV flow patterns were evaluable in 526/614(85.7%) patients, 48.9% of whom had PVSFR. Patients with PVSFR had more severe MR, reduced stroke volume and cardiac output, greater right ventricular dysfunction, and worse hemodynamics. By multivariable analysis, PVSFR was not an independent predictor of 2-year all-cause death, or heart failure hospitalization (HFH). The reductions in the 2-year rates of all-cause death and HFH with TEER compared with GDMT alone were similar in patients with and without PVSFR (Pinteraction = 0.40 and 0.12, respectively). The effect of TEER on improving Kansas City Cardiomyopathy Questionnaire scores and 6-minute walk distance were also independent of PVSFR. Conclusions: In the COAPT trial, PVSFR identified HF patients with severe MR and more advanced heart disease. Patients with and without PVSFR had consistent reductions in mortality, HFH, and improved quality-of-life and functional capacity after TEER. Clinical Trial Registration: ClinicalTrial.gov IdentifierNCT01626079.

3.
Am J Cardiol ; 230: 50-57, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39117008

RESUMO

Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has been associated with favorable outcomes in patients with degenerated stentless bioprosthesis. However, whether the outcomes after ViV TAVR for failed stentless bioprosthesis differ between balloon-expandable valves (BEVs) and self-expanding valves (SEVs) remains unknown. Therefore, we retrospectively analyzed 59 consecutive patients who underwent ViV TAVR for failed stentless bioprsothesis with BEVs (n = 42) versus SEVs (n = 17) in a single-health care system between 2013 and 2022. Overall, the mean age was 70.8 years and 74.6% were men. The mean transcatheter valve size was 26.3 ± 2.2 mm for BEVs and 26.4 ± 4 mm for SEVs (p = 0.93). The mean Society of Thoracic Surgeons score was 6.0 ± 3.6 for BEVs and 7.5 ± 5.5 for SEVs (p = 0.22). Compared with patients who received BEVs, those who received SEVs had higher rates of device malposition (2.4% vs 23.5%, p <0.01), postdeployment balloon dilation (11.9% vs 35.5%, p = 0.04) and need for a second transcatheter device (2.4% vs 35.5%, p <0.01). However, both groups showed similar improvement in aortic valve function at 30-day and 1-year follow-up (incidence of 1-year severe patient-prosthesis mismatch in BEVs: 17.6% vs 14.3% in SEVs, p = 0.78). The 1- and 3-year mortality did not differ between BEVs and SEVs (11.9% vs 11.8% and 25% vs 30%, respectively, Log rank p = 0.9). In conclusion, performing ViV TAVR for failed stentless bioprsothesis is technically challenging, especially when using SEVs; however, satisfactory positioning is possible in most cases, with excellent hemodynamic and clinical outcomes with BEVs and SEVs.

4.
JACC Adv ; 3(7): 100981, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39130036

RESUMO

Shared decision-making (SDM) and multidisciplinary team-based care delivery are recommended across several cardiology clinical practice guidelines. However, evidence for benefit and guidance on implementation are limited. Informed consent, the use of patient decision aids, or the documentation of these elements for governmental or societal agencies may be conflated as SDM. SDM is a bidirectional exchange between experts: patients are the experts on their goals, values, and preferences, and clinicians provide their expertise on clinical factors. In this Expert Panel perspective, we review the current state of SDM in team-based cardiovascular care and propose best practice recommendations for multidisciplinary team implementation of SDM.

5.
Am J Cardiol ; 231: 11-19, 2024 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-39209242

RESUMO

Data on the long-term outcomes of prosthesis patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) remain controversial. This study aimed to investigate the incidence and clinical outcomes of measured PPM (PPMM) and predicted PPM (PPMP) in patients who underwent TAVI. This is a retrospective analysis of 3,016 patients who underwent TAVI at a large health care system between 2012 and 2021. Effective orifice area indexed to body surface area (EOAi) was measured at discharge using the continuity equation. EOAi was predicted according to the published predictive tables for each model and size of the valve. Primary end point was 5-year survival rate. Mean age was 80 years, and 55.6% were male. The mean Society of Thoracic Surgeons risk score was 4.66%. 74.9% of patients received a balloon-expandable valve (BEV), and 25.1% received a self-expanding valve (SEV). The incidence of severe PPM was markedly lower when defined by predicted versus measured EOAi (0.8% vs 6.3%, p <0.001) and when assessed in SEV versus BEV (5.3% vs 6.6%, p = 0.02). Neither severe PPMp nor severe PPMM was associated with 5-year mortality (hazard ratio 1.26, 95% confidence interval 0.96 to 1.66, p = 0.095; hazard ratio 1.03, 95% confidence interval 0.42 to 2.49, p = 0.954, respectively), irrespective of the presence of high residual pressure gradient. Neither BEV nor SEV was associated with an increased 5-year mortality, irrespective of PPM definition or severity. In this large health care system analysis, neither severe PPMP nor severe PPMM was associated with 5-year all-cause mortality. There was no difference between BEV and SEV in terms of mortality, irrespective of the definition or severity of PPM.

6.
J Soc Cardiovasc Angiogr Interv ; 3(2): 101227, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-39132211

RESUMO

Background: Risk scores may identify patients with mitral regurgitation (MR) who are at risk for adverse events, but who may still benefit from transcatheter edge-to-edge repair (TEER). We sought to cross-validate the MitraScore and COAPT risk score to predict adverse events in patients undergoing TEER. Methods: MitraScore validation was carried out in the COAPT population which included 614 patients with FMR who were randomized 1:1 to guideline-directed medical therapy (GDMT) with or without TEER and were followed for 2 years. Validation of the COAPT risk score was carried out in 1007 patients from the MIVNUT registry of TEER-treated patients with both FMR and degenerative MR who were followed for a mean of 2.1 years. The predictive value was assessed using the area under the receiver operating characteristic curve (AUC) plots. The primary outcome was all-cause mortality. Results: The MitraScore had fair to good predictive accuracy for mortality in the overall COAPT trial population (AUC, 0.67); its accuracy was higher in patients treated with TEER (AUC, 0.74) than GDMT alone (AUC, 0.65). The COAPT risk score had fair predictive accuracy for death in the overall MitraScore cohort (AUC, 0.64), which was similar in patients with FMR and degenerative MR (AUC, 0.64 and 0.66, respectively). There was a consistent benefit of treatment with TEER plus GDMT compared with GDMT alone in the COAPT trial population across all MitraScore risk strata. Conclusions: The COAPT risk score and MitraScore are simple tools that are useful for the prediction of 2-year mortality in patients eligible for or undergoing treatment with TEER.

7.
J Soc Cardiovasc Angiogr Interv ; 3(5): 101345, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-39132458

RESUMO

Background: Transcatheter edge-to-edge repair (TEER) improved outcomes in patients with heart failure (HF) and severe secondary mitral regurgitation (SMR) compared with guideline-directed medical therapy (GDMT) alone regardless of the severity of baseline left ventricular ejection fraction (LVEF). The study aimed to evaluate the effect of early changes in LVEF after TEER and GDMT alone in patients with HF and severe SMR. Methods: Within the COAPT trial, we evaluated outcomes according to changes in LVEF from baseline to 30 days. The primary outcome was all-cause death or HF hospitalization (HFH) between 30 days and 2 years. Results: Among 432 patients with paired echocardiographic data, 182 (42.1%) had increased LVEF (LVEF change 6.0% ± 4.9%) and 250 (57.9%) had a decrease or no change in LVEF (LVEF change -6.6% ± 5.6%) from baseline to 30 days. LVEF at 30 days increased more frequently with GDMT alone compared with TEER plus GDMT (51.4% vs 33.0%; P = .0001). Between 30 days and 2 years, there were no significant differences in death or HFH in the increase LVEF and the decrease LVEF groups (58.8% vs 51.4%; multivariable-adjusted HR, 0.97; 95% CI, 0.87-1.08; P = .59). TEER plus GDMT reduced the 30-day to 2-year rate of death or HFH compared with GDMT alone consistently in patients with increase LVEF and decrease LVEF (Pint = 0.75). Conclusions: Among patients with HF and severe SMR, early improvements in LVEF were more frequent with GDMT alone compared with TEER plus GDMT but were not associated with subsequent outcomes at 2 years. TEER reduced death or HFH during 2-year follow-up irrespective of early LVEF changes.

8.
J Am Coll Cardiol ; 84(9): 832-847, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39168570

RESUMO

Pathologic left ventricular remodeling and valvular heart disease may contribute to the clinical presentation and outcomes of patients presenting with heart failure, and limit the effectiveness of guideline-directed medical therapy. Although surgical interventions including surgical ventricular restoration techniques and valve repair or replacement are effective therapies, there is growing evidence that transcatheter interventions may be options for patients with persistent symptoms of heart failure despite optimal medical therapy, where surgical options may be limited. This scientific statement will review the current available and investigational percutaneous strategies for the management of structural contributors to heart failure: dilated left ventricular cardiomyopathies and valvular heart disease.


Assuntos
Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/terapia , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/terapia , Procedimentos Cirúrgicos Cardíacos/métodos , Cardiomiopatia Dilatada/terapia , Cardiomiopatia Dilatada/fisiopatologia
10.
Circ Cardiovasc Interv ; 17(8): e013782, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39034924

RESUMO

BACKGROUND: Transcatheter mitral valve-in-valve replacement offers a less-invasive alternative for high-risk patients with bioprosthetic valve failure. Limited experience exists in intermediate-risk patients. We aim to evaluate 1-year outcomes of the PARTNER 3 mitral valve-in-valve study. METHODS: This prospective, single-arm, multicenter study enrolled symptomatic patients with a failing mitral bioprosthesis demonstrating greater than or equal to moderate stenosis and regurgitation and Society of Thoracic Surgeons score ≥3% and <8%. A balloon-expandable transcatheter heart valve (SAPIEN 3, Edwards Lifesciences) was used via a transeptal approach. The primary end point was the composite of all-cause mortality and stroke at 1 year. RESULTS: A total of 50 patients from 12 sites underwent mitral valve-in-valve from 2018 to 2021. The mean age was 70.1±9.7 years, mean Society of Thoracic Surgeons score was 4.1%±1.6%, and 54% were female. There were no primary end point events (mortality or stroke) through 1 year, and no left-ventricular outflow tract obstruction, endocarditis, or mitral valve reintervention was reported. Six patients (12%) required rehospitalization, including heart failure (n=2), minor procedural side effects (n=2), and valve thrombosis (n=2; both resolved with anticoagulation). An additional valve thrombosis was associated with no significant clinical sequelae. From baseline to 1 year, all subjects with available data had none/trace or mild (grade 1+) mitral regurgitation and the New York Heart Association class improved in 87.2% (41/47) of patients. CONCLUSIONS: Mitral valve-in-valve with a balloon-expandable valve via transseptal approach in intermediate-risk patients was associated with improved symptoms and quality of life, adequate transcatheter valve performance, and no mortality or stroke at 1-year follow-up. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03193801.


Assuntos
Bioprótese , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Valva Mitral , Desenho de Prótese , Falha de Prótese , Recuperação de Função Fisiológica , Humanos , Feminino , Masculino , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Valva Mitral/diagnóstico por imagem , Idoso , Estudos Prospectivos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Fatores de Tempo , Resultado do Tratamento , Fatores de Risco , Pessoa de Meia-Idade , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Medição de Risco , Idoso de 80 Anos ou mais , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/mortalidade , Estados Unidos , Estenose da Valva Mitral/cirurgia , Estenose da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/mortalidade , Estenose da Valva Mitral/diagnóstico por imagem , Hemodinâmica , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade
11.
Ann Thorac Surg ; 118(4): 920-930, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38972369

RESUMO

BACKGROUND: Perioperative blood transfusion is associated with adverse outcomes and higher costs after coronary artery bypass graft (CABG) surgery. We developed risk assessments for patients' probability of perioperative transfusion and the expected transfusion volume to improve clinical management and resource use. METHODS: Among 1,266,545 consecutive (2008-2016) isolated CABG operations in The Society of Thoracic Surgeons Adult Cardiac Surgery Database, 657,821 (51.9%) received perioperative transfusions of red blood cells (RBC), fresh frozen plasma (FFP), cryoprecipitate, and/or platelets. We developed "full" models to predict perioperative transfusion of any blood product, and of RBC, FFP, or platelets. Using least absolute shrinkage and selection operator model selection, we built a rapid risk score based on 5 variables (age, body surface area, sex, preoperative hematocrit, and use of intra-aortic balloon pump). RESULTS: C statistics for the full model were 0.785, 0.815, 0.707, and 0.699 for any blood product, RBC, FFP, and platelets, respectively. C statistics for rapid risk assessments were 0.752, 0.785, 0.670, and 0.661 for any blood product, RBC, FFP, and platelets, respectively. The observed vs expected risk plots showed strong calibration for full models and risk assessment tools; absolute differences between observed and expected risks of transfusion were <10.8% in each percentile of expected risk. Risk assessment-predicted probabilities of transfusion were strongly and nonlinearly associated (P < .0001) with total units transfused. CONCLUSIONS: These robust and well-calibrated risk assessment tools for perioperative transfusion in CABG can inform surgeons regarding patients' risks and the number of RBC, FFP, and platelets units they can expect to need. This can aid in optimizing outcomes and increasing efficient use of blood products.


Assuntos
Transfusão de Sangue , Ponte de Artéria Coronária , Bases de Dados Factuais , Sociedades Médicas , Humanos , Ponte de Artéria Coronária/efeitos adversos , Masculino , Feminino , Medição de Risco , Transfusão de Sangue/estatística & dados numéricos , Idoso , Pessoa de Meia-Idade , Cirurgia Torácica , Estudos Retrospectivos , Estados Unidos/epidemiologia , Doença da Artéria Coronariana/cirurgia
12.
JACC Cardiovasc Interv ; 17(14): 1631-1651, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39048251

RESUMO

Transcatheter aortic valve replacement (TAVR) has become more common than surgical aortic valve replacement since 2016, with over 200,000 procedures globally each year. As patients increasingly outlive their TAVR devices, managing these cases is a growing concern. Treatment options include surgical removal of the old TAVR device (transcatheter aortic valve [TAV] explant) or implantation of a new transcatheter aortic valve (redo TAV). Redo TAV is complex because of the unique designs of TAV devices; compatibility issues; and the need for individualized planning based on factors such as implant depth, shape, and coronary artery relationships. This review serves as a comprehensive guide for redo TAV, detailing the design characteristics of TAV devices, device compatibility, standardized terminology, and a structured approach for computed tomography analysis. It aims to facilitate decision making, risk identification, and achieving optimal outcomes in redo TAV procedures.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Reoperação , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Resultado do Tratamento , Fatores de Risco , Tomada de Decisão Clínica , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Terminologia como Assunto , Valor Preditivo dos Testes
13.
JACC Adv ; 3(3): 100853, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38938841

RESUMO

Background: Low stroke volume index <35 ml/m2 despite preserved ejection fraction (paradoxical low flow [PLF]) is associated with adverse outcomes in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). However, whether the risk associated with PLF is similar in both sexes is unknown. Objectives: The purpose of this study was to analyze the risk associated with PLF in severe aortic stenosis for men and women randomized to TAVR or SAVR. Methods: Patients with ejection fraction ≥50% from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were stratified by sex and treatment arm. The impact of PLF on the 2-year occurrence of the composite of death or heart failure hospitalization (primary endpoint) and of all-cause mortality alone (secondary endpoint) was analyzed. Analysis of variance was used to assess baseline differences between groups. Multivariate Cox regression analysis was used to identify predictors of the endpoint. Results: Out of 2,242 patients, PLF was present in 390 men and 239 women (30% vs 26%, P = 0.06). PLF was associated with a higher rate of NYHA functional class III to IV dyspnea (60% vs 54%, P < 0.001) and a higher prevalence of atrial fibrillation (39% vs 24%, P < 0.001). PLF was a significant predictor of the primary endpoint among women undergoing SAVR in multivariate analysis (adjusted HR: 2.25 [95% CI: 1.14-4.43], P = 0.02) but was not associated with a worse outcome in any of the other groups (all P > 0.05). Conclusions: In women with PLF, TAVR may improve outcomes compared to SAVR. PLF appears to have less impact on outcomes in men.

14.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38866455

RESUMO

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estimulação Cardíaca Artificial , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Fatores de Risco , Idoso , Fatores de Tempo , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Medição de Risco , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Estados Unidos/epidemiologia
15.
Am J Cardiol ; 225: 171-177, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38897265

RESUMO

Severe tricuspid regurgitation remains largely undertreated given limited treatment options. Transcatheter tricuspid valve interventions have emerged as a promising therapy for these patients, and the TRISCEND II pivotal trial is the first randomized controlled trial to evaluate transcatheter tricuspid valve replacement (TTVR). The TRISCEND II pivotal trial studies the transcatheter EVOQUE (Edwards Lifesciences, Irvine, California) tricuspid valve replacement system using a United States Food and Drug Administration Breakthrough Device Designation-a program intended to provide timely access to medical devices by speeding up development, assessment, and review. The TRISCEND II trial is a prospective, multicenter trial that randomizes patients with symptomatic severe tricuspid regurgitation to treatment with either TTVR in conjunction with optimal medical therapy or optimal medical therapy alone. The trial's novel 2-phase design evaluates 30-day safety and 6-month effectiveness end points for the first 150 patients in the initial phase and a 1-year safety and effectiveness end point for the full cohort of 400 patients in the second phase. The TRISCEND II trial's 2-phase trial design provided an opportunity for early review and led to the first commercial approval of a TTVR system. In conclusion, the design of the TRISCEND II trial will likely inform future transcatheter tricuspid device trials.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/métodos , Valva Tricúspide/cirurgia , Estudos Prospectivos , Próteses Valvulares Cardíacas , Resultado do Tratamento
16.
Proc (Bayl Univ Med Cent) ; 37(4): 569-575, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38910820

RESUMO

Background: Among patients with bicuspid aortic valves (BAV) who are potential candidates for valve-sparing root replacement (VSRR), the long-term durability of this technique is not well understood. This study aimed to compare the clinical and echocardiographic outcomes of VSRR in those with BAV and tricuspid aortic valve (TAV) morphology. Methods: This was a retrospective analysis of patients who underwent VSRR between 2007 and 2021 at a single center. Kaplan-Meier and log-rank analysis were used to estimate and compare freedom from mortality, progression to >2+ aortic insufficiency (AI), and reoperation between groups (BAV vs TAV). Preoperative and postoperative echocardiographic data were collected and assessed for temporal changes in mixed-effect models. Results: A total of 185 patients (BAV, n = 52, 28.1%; TAV, n = 133, 71.9%) underwent VSRR. At baseline, BAV patients were younger (42.4 ± 11.6 vs 52.3 ± 12.6 years; P < 0.01) and had more severe AI (47.9% vs 27.0%; P = 0.02). Average cardiopulmonary bypass and cross-clamp times were similar. There were no differences in rates of postoperative complications, intensive care unit or hospital days, or 30-day readmission. TAV patients' 1-, 5-, and 8-year survival rates were 99.2% [95% CI 97.8-100], 96.7% [93.5-99.9%], and 92.2% [85.6-99.3%], respectively. Overall, there were no differences between groups regarding freedom from mortality (P = 0.18), reoperation (P = 0.51), or recurrent >2+ AI (P = 0.97). . Conclusions: VSRR can be safely performed on patients with BAV and TAV morphology, yielding similar midterm freedom from mortality, recurrent >2+ AI, and reoperation. This technique should be considered in carefully selected patients with aortic root pathology and BAV anatomy when performed at experienced centers.

17.
JAMA Cardiol ; 9(7): 631-639, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38776106

RESUMO

Importance: The use of valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has been rapidly expanding as an alternative treatment to redo surgical aortic valve replacement (SAVR) for failed bioprosthetic valves despite limited long-term data. Objective: To assess mortality and morbidity in patients undergoing intervention for failed bioprosthetic SAVR. Design, Setting, and Participants: This was a retrospective population-based cohort analysis conducted between January 1, 2015, and December 31, 2020, with a median (IQR) follow-up time of 2.3 (1.1-4.0) years. A total of 1771 patients with a history of bioprosthetic SAVR who underwent ViV-TAVR or redo SAVR in California, New York, and New Jersey were included. Data were obtained from the California Department of Health Care Access and Information, the New York Statewide Planning and Research Cooperative System, and the New Jersey Discharge Data Collection System. Exclusion criteria included undergoing TAVR or redo SAVR within 5 years from initial SAVR, as well as infective endocarditis, concomitant surgical procedures, and out-of-state residency. Propensity matching yielded 375 patient pairs. Data were analyzed from January to December 2023. Interventions: ViV-TAVR vs redo SAVR. Main Outcomes and Measurements: The primary outcome was all-cause mortality. Secondary outcomes were stroke, heart failure hospitalization, reoperation, major bleeding, acute kidney failure, new pacemaker insertion, and infective endocarditis. Results: From 2015 through 2020, the proportion of patients undergoing ViV-TAVR vs redo SAVR increased from 159 of 451 (35.3%) to 498 or 797 (62.5%). Of 1771 participants, 653 (36.9%) were female, and the mean (SD) age was 74.4 (11.3) years. Periprocedural mortality and stroke rates were similar between propensity-matched groups. The ViV-TAVR group had lower periprocedural rates of major bleeding (2.4% vs 5.1%; P = .05), acute kidney failure (1.3% vs 7.2%; P < .001), and new pacemaker implantations (3.5% vs 10.9%; P < .001). The 5-year all-cause mortality rate was 23.4% (95% CI, 15.7-34.1) in the ViV-TAVR group and 13.3% (95% CI, 9.2-18.9) in the redo SAVR group. In a landmark analysis, no difference in mortality was observed up to 2 years (hazard ratio, 1.03; 95% CI, 0.59-1.78), but after 2 years, ViV-TAVR was associated with higher mortality (hazard ratio, 2.97; 95% CI, 1.18-7.47) as well as with a higher incidence of heart failure hospitalization (hazard ratio, 3.81; 95% CI, 1.57-9.22). There were no differences in 5-year incidence of stroke, reoperation, major bleeding, or infective endocarditis. Conclusions and Relevance: Compared with redo SAVR, ViV-TAVR was associated with a lower incidence of periprocedural complications and a similar incidence of all-cause mortality through 2 years' follow-up. However, ViV-TAVR was associated with higher rates of late mortality and heart failure hospitalization. These findings may be influenced by residual confounding and require adjudication in a randomized clinical trial.


Assuntos
Bioprótese , Reoperação , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Idoso , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Reoperação/estatística & dados numéricos , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos
18.
Am J Cardiol ; 223: 7-14, 2024 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-38788821

RESUMO

The frequency and effectiveness of repeat mitral valve interventions (RMVI) after transcatheter edge-to-edge repair (TEER) for secondary mitral regurgitation (MR) are unknown. We aimed to examine the rate of and outcomes after RMVI after TEER in the Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation (COAPT) trial. Only 3.9% of COAPT trial patients required a repeat mitral valve intervention during 4-year follow-up which was successful in 90% of cases but was associated with an increased rate of heart failure (HF) hospitalizations (HFH). The COAPT trial randomized HF patients with severe secondary MR to TEER with the MitraClip device plus guideline-directed medical therapy (GDMT) versus GDMT alone. We evaluated the characteristics and outcomes of patients who had an RMVI during 4-year follow-up. A MitraClip implant was attempted in 293 patients randomized to TEER+GDMT, 10 of whom underwent an RMVI procedure (9 repeat TEER and 1 surgical mitral valve replacement) after 4 years of follow-up (cumulative incidence 3.90%, 95% confidence interval [CI] 2.08 to 7.08; median 182 days after the initial procedure). Patients with RMVI had larger mitral annular diameters, fewer clips implanted, and were more likely to have ≥3+MR at discharge compared with those without RMVI. Reasons for RMVI included failed index procedure because of difficult transseptal puncture (n = 2) or tamponade (n = 1); residual or recurrent severe MR after an initially successful procedure (n = 5); partial clip detachment (n = 1); and site-assessed mitral stenosis (n = 1). RMVI was successful in 8/10 (80%) patients. Patients who underwent RMVI had higher 4-year rates of HFH but similar mortality compared with those without RMVI. The annualized incidence rates of all HFH in patients who underwent RMVI were 234 events per 100 person-years (95% CI 139 to 395) pre-RMVI and 46 per 100 person-years (95% CI 25 to 86) post-RMVI as compared with 32 events per 100 patient-years (95% CI 28 to 36) in patients without RMVI. The rate ratio of HFH was reduced after RMVI in patients who underwent RMVI (0.20, 95% CI 0.09 to 0.45). In conclusion, the cumulative incidence of RMVI after 4 years was 3.9% in patients who underwent TEER for severe secondary MR in the COAPT trial. Patients who underwent RMVI were at increased risk of HFH which was reduced after the RMVI procedure. Clinical Trial Registration: Clinical Trial Name: Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation (The COAPT Trial) (COAPT) ClinicalTrial.gov Identifier: NCT01626079 URL:https://clinicaltrials.gov/ct2/show/NCT01626079.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Masculino , Feminino , Idoso , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Seguimentos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Reoperação , Insuficiência Cardíaca/terapia
19.
JACC Cardiovasc Imaging ; 17(9): 1015-1027, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38795108

RESUMO

BACKGROUND: Functional mitral regurgitation induces adverse effects on the left ventricle and the left atrium. Left atrial (LA) dilatation and reduced LA strain are associated with poor outcomes in heart failure (HF). Transcatheter edge-to-edge repair (TEER) of the mitral valve reduces heart failure hospitalization (HFH) and all-cause death in selected HF patients. OBJECTIVES: The aim of this study was to evaluate the impact of LA strain improvement 6 months after TEER on the outcomes of patients enrolled in the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) trial. METHODS: The difference in LA strain between baseline and the 6-month follow-up was calculated. Patients with at least a 15% improvement in LA strain were labeled as "LA strain improvers." All-cause death and HFH were assessed between the 6- and 24-month follow-up. RESULTS: Among 347 patients (mean age 71 ± 12 years, 63% male), 106 (30.5%) showed improvement of LA strain at the 6-month follow-up (64 [60.4%] from the TEER + guideline-directed medical therapy [GDMT] group and 42 [39.6%] from the GDMT alone group). An improvement in LA strain was significantly associated with a reduction in the composite of death or HFH between the 6-month and 24-month follow-up, with a similar risk reduction in both treatment arms (Pinteraction = 0.27). In multivariable analyses, LA strain improvement remained independently associated with a lower risk of the primary composite endpoint both as a continuous variable (adjusted HR: 0.94 [95% CI: 0.89-1.00]; P = 0.03) and as a dichotomous variable (adjusted HR: 0.49 [95% CI: 0.27-0.89]; P = 0.02). The best outcomes were observed in patients treated with TEER in whom LA strain improved. CONCLUSIONS: In symptomatic HF patients with severe mitral regurgitation, improved LA strain at the 6-month follow-up is associated with subsequently lower rates of the composite endpoint of all-cause mortality or HFH, both after TEER and GDMT alone. (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation [COAPT]; NCT01626079).


Assuntos
Função do Átrio Esquerdo , Cateterismo Cardíaco , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Recuperação de Função Fisiológica , Humanos , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Masculino , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/diagnóstico por imagem , Idoso , Resultado do Tratamento , Fatores de Tempo , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade
20.
Eur Heart J ; 45(28): 2519-2532, 2024 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-38820201

RESUMO

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.


Assuntos
Endocardite , Falha de Prótese , Infecções Relacionadas à Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/mortalidade , Endocardite/cirurgia , Endocardite/mortalidade , Remoção de Dispositivo , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA