Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Orthop Sports Phys Ther ; 29(8): 470-7, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10444737

RESUMO

STUDY DESIGN: Single-group repeated measures for single rater reliability. OBJECTIVES: To describe the intratester reliability for measurements of active lumbar spine mobility and pelvic inclination during standing obtained with the back range-of-motion (BROM) device. BACKGROUND: The BROM device has often been used to quantify lumbar spine active range of motion. No studies have reported the reliability of the BROM device in a clinical setting. METHODS AND MEASURES: One examiner measured all 3 planes of lumbar range of motion in 40 nonimpaired subjects. For each plane of motion, 2 BROM device measurements were made. Intraclass correlation coefficients were calculated to express the intratester reliability for each plane of motion measured. RESULTS: Intraclass correlation coefficients were in the range of 0.67 to 0.94 for lumbar measurements with the BROM device. CONCLUSIONS: Intratester reliability was fair to poor for sagittal plane measurements and pelvic inclination. Measurements obtained by the same examiner for lumbar lateral flexion and rotation with the BROM device, however, were reliable.


Assuntos
Dor Lombar , Modalidades de Fisioterapia/instrumentação , Amplitude de Movimento Articular , Adulto , Desenho de Equipamento , Feminino , Humanos , Região Lombossacral , Masculino , Variações Dependentes do Observador , Valores de Referência
2.
J Orthop Sports Phys Ther ; 17(3): 155-60, 1993 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8472080

RESUMO

We believe there is a need to identify a practical method for determining objective measurement of forward head posture. In our study, we determined the within-tester and between-tester reliabilities for clinical measurements of static, sitting, forward head posture using the cervical range of motion (CROM) instrument. Repeated measurements were made using a standardized protocol on 40 patients seated in a standardized position. The seven testers had from 1 to 8 years of clinical experience. All measurements were recorded by the same investigator. The intraclass correlation coefficient (ICC[1,1]) was used to quantitate within-tester and between-tester reliability. Measurements of forward head position performed by the same physical therapist had high reliability (ICC = 0.93). Good reliability (ICC = 0.83) was demonstrated when different physical therapists measured the forward head posture of the same patient. We concluded that measurements of forward head posture made by physical therapists trained in the correct use of the CROM instrument are reliable. This reliability is important for determining the effectiveness of treatment programs. On the basis of our data, the CROM instrument will assist clinicians in the objective evaluation and reassessment of the patient population demonstrating forward head posture.


Assuntos
Cabeça/fisiopatologia , Pescoço/fisiopatologia , Dor/etiologia , Postura , Adulto , Idoso , Fenômenos Biomecânicos , Vértebras Cervicais/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modalidades de Fisioterapia/instrumentação , Amplitude de Movimento Articular , Reprodutibilidade dos Testes
3.
Biofeedback Self Regul ; 16(2): 167-79, 1991 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-1854861

RESUMO

Electromyographic (EMG) muscle scanning measures brief samples of integrated muscle action potentials from individual muscles using a hand-held scanner with post-style electrodes. This "scanning" technique is widely used by biofeedback practitioners to quickly assess muscle activity in the diagnosis of musculoskeletal disorders. In an effort to compare muscle scanning with the established technique using attached surface electrodes, ten healthy subjects (25-35 years old) were scanned using 2-second sampling at five bilateral muscle sites while simultaneously monitoring the same sites with surface electrodes. This was repeated using 10-second scanning samplings. Pearson's product-moment correlations between scanning for 2 seconds and prolonged surface recording at all sites were 0.54-0.89. Scanning for 10 seconds improved the correlations to 0.68-0.91. EMG scanning for 2 seconds compares favorably with attached surface electrode recording. Comparisons are further improved by 10-second scans.


Assuntos
Eletrodos , Eletromiografia , Músculos/fisiologia , Adulto , Feminino , Humanos , Masculino , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...