Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Transl Vis Sci Technol ; 13(4): 2, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38564202

RESUMO

Purpose: Prior evidence suggests racial disparities in the utilization of visual field testing (VFT) for the diagnosis and monitoring of glaucoma. In this study, we considered the effect of baseline glaucoma severity and socioeconomic disadvantage along with other potential confounders such as test reliability, ancillary tests, and glaucoma surgeries on racial disparity in the frequency of VFT. Methods: The records of all subjects with a diagnosis of glaucoma who received VFT at an academic, tertiary care facility from January 2018 to December 2021 were accessed. Analysis was performed to compare VFT frequency, the total number of office visits (DoS), and the ratio of VFT frequency to DoS (VFT/DoS) across self-reported races while controlling for sex, age, socioeconomic disadvantage (Area Deprivation Index), VF reliability indicators and baseline mean deviation, optical coherence tomography frequency, and glaucoma surgeries. Results: Among the 2654 subjects (1515 White, 782 Black, and 357 Asian) included in this study, Black subjects had the worst socioeconomic status and disease severity at baseline. They also experienced a 3% lower VFT/DoS ratio compared to White subjects (P = 0.031). Asian subjects had a 5% lower VFT/DoS ratio compared to White subjects (P = 0.015). Discussion: We identified racial disparity in performing VFT in subjects with glaucoma even when multiple confounders were considered. Further investigation is necessary to identify other race-associated factors to work toward reducing racial disparities in VFT. Translational Relevance: Black and Asian subjects with glaucoma receive fewer VFT per visit compared to White subjects even when considering socioeconomic disadvantage and disease severity.


Assuntos
Glaucoma , Campos Visuais , Humanos , Asiático , Glaucoma/diagnóstico , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica , Brancos , Negro ou Afro-Americano
3.
Transl Vis Sci Technol ; 12(12): 2, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-38038606

RESUMO

Purpose: Race disparities in the healthcare system and the resulting inequality in clinical data among different races hinder the ability to generate equitable prediction results. This study aims to reduce healthcare disparities arising from data imbalance by leveraging advanced transfer learning (TL) methods. Method: We examined the ophthalmic healthcare disparities at a population level using electronic medical records data from a study cohort (N = 785) receiving care at an academic institute. Regression-based TL models were usesd, transferring valuable information from the dominant racial group (White) to improve visual field mean deviation (MD) rate of change prediction particularly for data-disadvantaged African American (AA) and Asian racial groups. Prediction results of TL models were compared with two conventional approaches. Results: Disparities in socioeconomic status and baseline disease severity were observed among the AA and Asian racial groups. The TL approach achieved marked to comparable improvement in prediction accuracy compared to the two conventional approaches as evident by smaller mean absolute errors or mean square errors. TL identified distinct key features of visual field MD rate of change for each racial group. Conclusions: The study introduces a novel application of TL that improved reliability of the analysis in comparison with conventional methods, especially in small sample size groups. This can improve assessment of healthcare disparity and subsequent remedy approach. Translational Relevance: TL offers an equitable and efficient approach to mitigate healthcare disparities analysis by enhancing prediction performance for data-disadvantaged group.


Assuntos
Disparidades em Assistência à Saúde , Aprendizado de Máquina , Humanos , Negro ou Afro-Americano , Reprodutibilidade dos Testes , Brancos , Asiático
5.
Clin Ophthalmol ; 17: 2929-2938, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37814637

RESUMO

Purpose: To offer clinical guidance and address safety and efficacy concerns regarding the growing use of micro-invasive glaucoma surgery (MIGS) as an initial treatment for glaucoma in adult patients. Design: Narrative literature review. Methods: A review was conducted to assess outcomes and complications of MIGS in the treatment of glaucoma, both alone and in combination with lens replacement. These outcomes were compared with those of standard glaucoma surgery and/or glaucoma management with medication. Results: MIGS are effective at lowering intraocular pressure (IOP) over long periods of follow-up. These techniques share a similarly high safety profile between one another. MIGS were found to have lower complication rates and to be more effective in reducing the total amount of medication needed to maintain control of intraocular pressure than standard surgery approaches. Conclusion: MIGS techniques are growing in popularity and have been demonstrated to be a safe and effective alternative to standard glaucoma surgery. Guidance in the implementation of these procedures has been outlined.

9.
PLoS One ; 18(3): e0270941, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36881575

RESUMO

This study was registered with ClinicalTrials.gov (ID: NCT03715231). A total of 20 participants (37 eyes) who were 18 or older and had glaucoma or were glaucoma suspects were enrolled from the NYU Langone Eye Center and Bellevue Hospital. During their usual ophthalmology visit, they were consented for the study and underwent 360-degree goniophotography using the NIDEK Gonioscope GS-1. Afterwards, the three ophthalmologists separately examined the images obtained and determined the status of the iridocorneal angle in four quadrants using the Shaffer grading system. Physicians were masked to patient names and diagnoses. Inter-observer reproducibility was determined using Fleiss' kappa statistics. The interobserver reliability using Fleiss' statistics was shown to be significant between three glaucoma specialists with fair overall agreement (Fleiss' kappa: 0.266, p < .0001) in the interpretation of 360-degree goniophotos. Automated 360-degree goniophotography using the NIDEK Gonioscope GS-1 have quality such that they are interpreted similarly by independent expert observers. This indicates that angle investigation may be performed using this automated device and that interpretation by expert observers is likely to be similar. Images produced from automated 360-degree goniophotography using the NIDEK Gonioscope GS-1 are similarly interpreted amongst glaucoma specialists, thus supporting use of this technique to document and assess the anterior chamber angle in patients with, or suspected of, glaucoma and iridocorneal angle abnormalities.


Assuntos
Glaucoma , Hipertensão Ocular , Humanos , Reprodutibilidade dos Testes , Glaucoma/diagnóstico por imagem , Olho , Hospitais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...