Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Invest ; 123(10): 4294-308, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24091324

RESUMO

Ischemic damage is recognized to cause cardiomyocyte (CM) death and myocardial dysfunction, but the role of cell-matrix interactions and integrins in this process has not been extensively studied. Expression of α7ß1D integrin, the dominant integrin in normal adult CMs, increases during ischemia/reperfusion (I/R), while deficiency of ß1 integrins increases ischemic damage. We hypothesized that the forced overexpression of integrins on the CM would offer protection from I/R injury. Tg mice with CM-specific overexpression of integrin α7ß1D exposed to I/R had a substantial reduction in infarct size compared with that of α5ß1D-overexpressing mice and WT littermate controls. Using isolated CMs, we found that α7ß1D preserved mitochondrial membrane potential during hypoxia/reoxygenation (H/R) injury via inhibition of mitochondrial Ca2+ overload but did not alter H/R effects on oxidative stress. Therefore, we assessed Ca2+ handling proteins in the CM and found that ß1D integrin colocalized with ryanodine receptor 2 (RyR2) in CM T-tubules, complexed with RyR2 in human and rat heart, and specifically bound to RyR2 amino acids 165-175. Integrins stabilized the RyR2 interdomain interaction, and this stabilization required integrin receptor binding to its ECM ligand. These data suggest that α7ß1D integrin modifies Ca2+ regulatory pathways and offers a means to protect the myocardium from ischemic injury.


Assuntos
Integrinas/metabolismo , Isquemia Miocárdica/metabolismo , Traumatismo por Reperfusão Miocárdica/metabolismo , Miócitos Cardíacos/metabolismo , Sequência de Aminoácidos , Animais , Cálcio/metabolismo , Hipóxia Celular , Células Cultivadas , Humanos , Integrinas/química , Masculino , Potencial da Membrana Mitocondrial , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Dados de Sequência Molecular , Isquemia Miocárdica/patologia , Traumatismo por Reperfusão Miocárdica/patologia , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/metabolismo , Fosforilação , Ligação Proteica , Domínios e Motivos de Interação entre Proteínas , Processamento de Proteína Pós-Traducional , Estabilidade Proteica , Subunidades Proteicas/metabolismo , Ratos , Ratos Sprague-Dawley , Canal de Liberação de Cálcio do Receptor de Rianodina/química , Canal de Liberação de Cálcio do Receptor de Rianodina/metabolismo
2.
Radiother Oncol ; 88(1): 115-20, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17933407

RESUMO

PURPOSE: To compare the dosimetric results between MRI-based and TRUS-based preplanning in permanent prostate brachytherapy, and to estimate the accuracy of MRI-based preplanning by comparing with CT/MRI fusion-based postimplant dosimetry. METHODS AND MATERIALS: Twenty-one patients were entered in this prospective study with written informed consent. MRI-based and TRUS-based preplanning were performed. The seed and needle locations were identical according to MRI-based and TRUS-based preplanning. MRI-based and TRUS-based preplanning were compared using DVH-related parameters. Following brachytherapy, the accuracy of the MRI-based preplanning was evaluated by comparing it with CT/MRI fusion-based postimplant dosimetry. RESULTS: Mean MRI-based prostate volume was slightly underestimated (0.73 cc in mean volume) in comparison to TRUS-based volume. There were no significant differences in the mean DVH-related parameters except with rectal V(100)(cc) between TRUS-based and MRI-based preplanning. Mean rectal V(100)(cc) was 0.74 cc in TRUS-based and 0.29 cc in MRI-based preplanning, respectively, and the values demonstrated a statistical difference. There was no statistical difference in mean rectal V(150)(cc), and rectal V(100)(cc) between MRI-based preplanning and CT/MRI fusion-based postimplant dosimetry. CONCLUSION: Prostate volume estimation and DVH-related parameters in MRI-based preplanning were almost identical to TRUS-based preplanning. From the results of CT/MRI fusion-based postimplant dosimetry, MRI-based preplanning was therefore found to be a reliable and useful modality, as well as being helpful for TRUS-based preplanning. MRI-based preplanning can more accurately predict postimplant rectal dose than TRUS-based preplanning.


Assuntos
Braquiterapia/métodos , Imagem por Ressonância Magnética Intervencionista , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia Intervencionista , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X , Ultrassonografia de Intervenção
3.
Radiat Med ; 25(7): 329-34, 2007 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-17705002

RESUMO

PURPOSE: No studies have yet evaluated the effects of a dosimetric analysis for different urethral volumes. We therefore evaluated the effects of a dosimetric analysis to determine the different urethral volumes. METHODS: This study was based on computed tomography/magnetic resonance imaging (CT/MRI) combined findings in 30 patients who had undergone prostate brachytherapy. Postimplant CT/MRI scans were performed 30 days after the implant. The urethra was contoured based on its diameter (8, 6, 4, 2, and 0 mm). The total urethral volume-in cubic centimeters [UrV150/200(cc)] and percent (UrV150%/200%), of the urethra receiving 150% or 200% of the prescribed dose-and the doses (UrD90/30/5) in Grays to 90%, 30%, and 5% of the urethral volume were measured based on the urethral diameters. RESULTS: The UrV150(cc) and UrD30 were statistically different between the of 8-, 6-, 4-, 2-, and 0-mm diameters, whereas the UrD5 was statistically different only between the 8-, 6-, and 4-mm diameters. Especially for UrD5, there was an approximately 40-Gy difference between the mean values for the 8- and 0-mm diameters. CONCLUSION: We recommend that the urethra should be contoured as a 4- to 6-mm diameter circle or one side of a triangle of 5-7 mm. By standardizing the urethral diameter, the urethral dose will be less affected by the total urethral volume.


Assuntos
Braquiterapia , Neoplasias da Próstata/radioterapia , Uretra/anatomia & histologia , Uretra/efeitos da radiação , Meios de Contraste , Gadolínio DTPA , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X , Ultrassonografia de Intervenção
4.
Radiat Med ; 25(1): 22-6, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17225049

RESUMO

PURPOSE: The aim of this study was to compare the outcomes between 1-mm and 5-mm section computed tomography (CT)-based postimplant dosimetry. MATERIALS AND METHODS: A series of 21 consecutive patients underwent permanent prostate brachytherapy. The postimplant prostate volume was calculated using 1-mm and 5-mm section CT. One radiation oncologist contoured the prostate on CT images to obtain the reconstructed prostate volume (pVol), prostate V(100) (percent of the prostate volume receiving at least the full prescribed dose), and prostate D(90) (mean dose delivered to 90% of the prostate gland). The same radiation oncologist performed the contouring three times to evaluate intraobserver variation and subjectively scored the quality of the CT images. RESULTS: The mean +/-1 SD postimplant pVol was 20.17 +/- 6.66 cc by 1-mm section CT and 22.24 +/- 8.48 cc by 5-mm section CT; the difference in the mean values was 2.06 cc (P < 0.01). The mean postimplant prostate V(100) was 80.44% +/- 7.06% by 1-mm section CT and 77.33% +/- 10.22% by 5-mm section CT. The mean postimplant prostate D(90) was 83.28% +/- 10.81% by 1-mm section CT and 78.60% +/- 15.75% by 5-mm section CT. In the evaluation of image quality, 5-mm section CT was assigned significantly higher scores than 1-mm section CT. In regard to intraobserver variation, 5-mm section CT revealed less intraobserver variation than 1-mm section CT. CONCLUSION: Our current results suggested that the outcomes of postimplant dosimetry using 1-mm section CT did not improved the results over those obtained using 5-mm section CT in terms of the quality of the CT image or reproducibility.


Assuntos
Braquiterapia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Tomografia Computadorizada por Raios X/métodos , Humanos , Radioisótopos do Iodo/uso terapêutico , Masculino , Dosagem Radioterapêutica
5.
Radiother Oncol ; 81(3): 303-8, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17125859

RESUMO

BACKGROUND AND PURPOSE: To compare the CT-based and CT/MRI fusion-based postimplant dosimetry after permanent prostate brachytherapy and to evaluate the improvement in CT-based dosimetry by physicians with or without experience in using the CT/MRI fusion method. PATIENTS AND METHODS: Thirty-eight consecutive patients agreed to participate in a prospective study. The prostate contours from CT/MRI fusion are the gold standard for determining the prostate volume and dose volume histogram (DVH). CT-based postimplant dosimetries were performed by two physicians. Observer 1 was a radiologist who had never used CT/MRI fusion method for postimplant dosimetric analysis. Observer 2 was a radiation oncologist experienced in postimplant analysis using the CT/MRI fusion method. The prostate dosimetry was evaluated by prostate D90 and V100. RESULTS: No significant difference was observed in the mean prostate volumes between the two observers and the CT/MRI fusion data. However, the correlation coefficient value for observer 2 (R(2)=0.932) was greater than that for observer 1 (R(2)=0.793). The D90 and V100 values as evaluated by the two observers were significantly underestimated in comparison to those evaluated using the CT/MRI fusion methods. The DVH related parameters were underestimated more frequently by observer 1 than by observer 2: (prostate D90: 99.56% for observer 1, 102.97% for observer 2, 109.37% for CT/MRI fusion. Prostate V100: 88.12% for observer 1, 90.14% for observer 2, 91.91% for CT/MRI fusion). CONCLUSIONS: The difference in the mean value in D90 and V100 by observer 1 was significantly greater than that for observer 2. These findings suggest that the CT/MRI fusion method provides accurate feedback which thereby improves CT-based postimplant dosimetry for prostate brachytherapy.


Assuntos
Braquiterapia , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Implantação de Prótese , Tomografia Computadorizada por Raios X/métodos , Humanos , Masculino , Estudos Prospectivos , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica
6.
Int J Radiat Oncol Biol Phys ; 66(2): 597-602, 2006 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-16966002

RESUMO

PURPOSE: The aim of this study was to compare the outcomes between magnetic resonance imaging (MRI)-based and computed tomography (CT)/MRI fusion-based postimplant dosimetry methods in permanent prostate brachytherapy. METHODS AND MATERIALS: Between October 2004 and March 2006, a total of 52 consecutive patients with prostate cancer were treated by brachytherapy, and postimplant dosimetry was performed using CT/MRI fusion. The accuracy and reproducibility were prospectively compared between MRI-based dosimetry and CT/MRI fusion-based dosimetry based on the dose-volume histogram (DVH) related parameters as recommended by the American Brachytherapy Society. RESULTS: The prostate volume was 15.97+/-6.17 cc (mean+/-SD) in MRI-based dosimetry, and 15.97+/-6.02 cc in CT/MRI fusion-based dosimetry without statistical difference. The prostate V100 was 94.5% and 93.0% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p=0.002). The prostate D90 was 119.4% and 114.4% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p=0.004). CONCLUSION: Our current results suggested that, as with fusion images, MR images allowed accurate contouring of the organs, but they tended to overestimate the analysis of postimplant dosimetry in comparison to CT/MRI fusion images. Although this MRI-based dosimetric discrepancy was negligible, MRI-based dosimetry was acceptable and reproducible in comparison to CT-based dosimetry, because the difference between MRI-based and CT/MRI fusion-based results was smaller than that between CT-based and CT/MRI fusion-based results as previously reported.


Assuntos
Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Tomografia Computadorizada por Raios X/métodos , Braquiterapia , Humanos , Masculino , Variações Dependentes do Observador , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica
7.
J Magn Reson Imaging ; 15(3): 330-3, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11891979

RESUMO

We report and assess the imaging findings in a patient with multiple arterioportal shunting mimicking multiple hypervascular tumors that showed multiple areas of hyperintensity with gadolinium-enhanced gradient-recalled-echo images obtained in the hepatic arterial phase and corresponding areas of slight hyperintensity with T2-weighted images.


Assuntos
Malformações Arteriovenosas/diagnóstico , Artéria Hepática/anormalidades , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Veia Porta/anormalidades , Idoso , Meios de Contraste , Diagnóstico Diferencial , Feminino , Gadolínio , Humanos
8.
J Magn Reson Imaging ; 15(2): 199-202, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11836777

RESUMO

Unenhanced T2-weighted fast spin-echo images obtained in a 65-year-old woman with severe cirrhosis showed an area of high signal intensity occupying the left second-order portal vein branch, suggesting portal vein thrombosis in cirrhosis. Doppler sonography, which revealed virtually no blood flow in the vessel, also supported the diagnosis. Gadolinium-enhanced MRI subsequently revealed the patency of the vessel. The extremely slow portal venous flow was considered to be the cause of false-positive findings with unenhanced MRI and sonography.


Assuntos
Imagem Ecoplanar/métodos , Circulação Hepática/fisiologia , Cirrose Hepática/fisiopatologia , Veia Porta/fisiopatologia , Trombose Venosa/etiologia , Trombose Venosa/patologia , Idoso , Feminino , Humanos , Cirrose Hepática/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...