Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vet Med Sci ; 83(7): 1075-1080, 2021 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-33994427

RESUMO

Pinnipeds have evolved enlarged ocular bulbs to catch fish in the dark. However, their large protruding eyes are easily damaged, which increases the risk of blindness and death in these animals. In captivity, ophthalmic disorders, manifested as keratitis and cataracts, are common among pinnipeds. In this study, we investigated symptoms of ophthalmic disorders in pinniped species using a questionnaire distributed to 32 zoos and aquariums throughout Japan. We conducted this study in cooperation with the Japanese Association of Zoos and Aquariums. The survey included 295 pinnipeds from four otariid species, five phocid species, and one odobenid species. Of these, 43.1% of the pinnipeds had diseases affecting the lens, cornea, and/or other eye parts. Age was positively associated with lens disorders in California sea lions, South American sea lions, and spotted seals. Conflicts and public appearances were also associated with corneal and/or lens disorders in California sea lions. Treatments were evaluated as effective for corneal disorders and conjunctivitis. The results of this study indicate that ophthalmic disorders in pinnipeds are related to the conditions of their captive environment. Aquariums and zoos should be encouraged to share information regarding optimal maintenance practices to improve the living conditions of pinnipeds.


Assuntos
Caniformia , Leões-Marinhos , Focas Verdadeiras , Animais , Japão/epidemiologia , Inquéritos e Questionários
2.
J Vet Med Sci ; 82(7): 922-925, 2020 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-32435005

RESUMO

The purpose of this study was to investigate the effects of pupil diameter on canine visual evoked potentials with pattern stimulation (P-VEP). Atropine eye drop (1.0%) was applied to both eyes as a cycloplegic drug, and tafluprost eye drop (0.015%) was applied to one eye that was selected randomly for miosis (miosis group). The other eye did not receive tafluprost (mydriasis group). P-VEP was recorded at three pattern sizes. The P100 implicit time at a small pattern size in the mydriasis group was significantly prolonged compared to the miosis group. We hypothesized that the prolonged P100 implicit time under mydriatic conditions was due to increased spherical aberrations and concluded that mydriatic conditions affected P100 implicit time in canine P-VEP recordings.


Assuntos
Cães/fisiologia , Potenciais Evocados Visuais , Pupila/efeitos dos fármacos , Animais , Atropina/administração & dosagem , Feminino , Masculino , Miose , Midriáticos/administração & dosagem , Soluções Oftálmicas/administração & dosagem , Reconhecimento Visual de Modelos , Prostaglandinas F/administração & dosagem , Prostaglandinas F/farmacologia
3.
J Vet Med Sci ; 82(6): 740-744, 2020 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-32295988

RESUMO

A twenty-year-old male Asiatic black bear (Ursus thibetanus) presented at the Rakuno Gakuen University Animal Medical Center with a 10-year history of bilateral blindness and cataracts. Surgical treatment of bilateral cataracts by extracapsular lensextraction using phacoemulsification and aspiration (PEA) was performed under general anesthesia. An anterior capsulectomy was performed using micro iris scissors and micro anterior lens capsule forceps. The cataract was removed with PEA using the two-handed technique. After surgery, systemic corticosteroids, anti-inflammatory drugs and antibiotics were administered. After cataract removal, the bear had recovered vision, and good quality vision has been maintained to date (15 months). PEA can be a safe and effective treatment for cataracts that impair vision in bears.


Assuntos
Catarata/veterinária , Facoemulsificação/veterinária , Ursidae/cirurgia , Animais , Masculino
4.
Vet Ophthalmol ; 22(6): 744-750, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30715776

RESUMO

OBJECTIVE: To investigate meibomian gland (MG) morphology by noncontact infrared meibography in Shih Tzu dogs with or without keratoconjunctivitis sicca (KCS). PROCEDURES: Fourteen eyes of 12 Shih Tzu dogs (mean age of 10.7 years, range of 7-13 years) presented to Yakumo Animal Hospital or Triangle Animal Eye Clinic from 2011 to 2017 with clinical signs and a Schirmer tear test (STT) result consistent with KCS (<10 mm/min) were examined. Twenty-eight eyes of 16 Shih Tzu dogs (mean age of 12.4 years, range of 8 to 15 years) with a STT > 15 mm/min served as healthy controls. Both groups of dogs underwent routine slitlamp biomicroscopy followed by noncontact infrared meibography of the upper eyelid with both desktop-type and mobile-type systems. Results Meibography revealed morphological abnormalities of MGs in 13 eyes of 11 dogs with KCS. The abnormalities included gland shortening in 64% and gland dropout in 64% of the 14 eyes in the KCS group. Morphological changes were also observed in MGs of 16 eyes of 10 dogs in the control group. These changes included shortening in 46% and dropout in 17.8% of the 28 eyes in the control group. Dropout was significantly more common in eyes with KCS than in control eyes (P < 0.01). Conclusions The frequency of MG abnormalities is increased in Shih Tzus with KCS compared with control animals. A reduced quality of the tear film associated with increased evaporation and reduced retention of tear fluid likely exacerbates the effects of a reduced tear volume in animals with aqueous deficiency.


Assuntos
Doenças do Cão/patologia , Ceratoconjuntivite Seca/veterinária , Glândulas Tarsais/patologia , Animais , Cães , Feminino , Humanos , Raios Infravermelhos , Ceratoconjuntivite Seca/patologia , Masculino
5.
J Vet Med Sci ; 81(1): 30-34, 2019 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-30404994

RESUMO

An 8-year-old castrated Toy poodle presented with swelling and proptosis of the right third eyelid caused by an exophytic mass on the bulbar surface. Histologically, the mass was composed of stratified neoplastic basaloid cells, arranged in nests and interconnecting islands, which were mixed with tubular structures. Immunohistochemically, the basaloid cells were positive for p63 and cytokeratin (CK) 14, and the inner epithelial cells of the tubular structures were positive for CK7, CK8, and CK19. According to these findings, the mass was diagnosed as a basal cell adenocarcinoma. Although basal cell adenocarcinoma is rare in animals, it should be included in the list of differential diagnoses for superficial tumors of bulbar conjunctiva of third eyelid in dogs.


Assuntos
Adenocarcinoma/veterinária , Túnica Conjuntiva/patologia , Neoplasias da Túnica Conjuntiva/veterinária , Doenças do Cão/patologia , Membrana Nictitante , Adenocarcinoma/patologia , Animais , Neoplasias da Túnica Conjuntiva/patologia , Cães , Feminino
6.
J Vet Med Sci ; 80(11): 1733-1736, 2018 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-30270234

RESUMO

Intraocular cholesterol granuloma (CG) associated with synchysis scintillans (SS) was diagnosed in a 5-year-old spayed Shetland sheepdog. During the initial clinical examination, the patient exhibited SS in the anterior chamber. Canine SS is usually found in the vitreous cavity, and SS in the anterior chamber has not been described. Since canine SS has been reported to be a non-progressive condition, and its long-term clinical course has not been adequately documented. The present case report describes the long-term clinical course of a case of canine SS, in which SS occurred in the anterior chamber, leading to intraocular CG formation, and eventually glaucoma.


Assuntos
Câmara Anterior/patologia , Colesterol , Doenças do Cão/diagnóstico , Oftalmopatias/veterinária , Animais , Cães , Oftalmopatias/diagnóstico , Oftalmopatias/patologia , Feminino , Granuloma/veterinária
7.
J Vet Med Sci ; 80(11): 1758-1761, 2018 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-30282843

RESUMO

We tried measurement of visual acuity in laboratory beagle using pattern stimulus visual evoked potential (P-VEP). We recorded P-VEP in 6 beagles which were corrected refractive power. The stimulus pattern size was 1.22 mm. The testing distance were 0.5, 1.0, and 2.0 m. The visual angles and spatial frequency were calculated from stimulus pattern size and distance. In all subjects, P-VEP was clearly recorded in all testing distance, and this result means that the eye could recognized grid pattern on the stimulus monitor. When stimulus monitor was set up 2.0 m, spatial frequency was 14.29 cpd. From our results, it was founded that the visual acuity in laboratory beagle which was corrected refractive power was 14.29 cpd and more.


Assuntos
Cães/fisiologia , Potenciais Evocados Visuais , Reconhecimento Visual de Modelos , Acuidade Visual , Animais
8.
Vet Ophthalmol ; 20(4): 310-315, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27480239

RESUMO

OBJECTIVE: To study a new approach to indocyanine green (ICG) angiography for contrasting the ocular fundus in cats. ANIMALS STUDIED: Six healthy laboratory cats. PROCEDURES: Fluorescein (FLUO) and ICG angiography were performed using an infrared-sensitive charged coupled device-equipped fundus camera on sedated cats. RESULTS: At 12.3 ± 3.4 s after ICG administration, the choroidal arteries could be seen extending radially from the optic disk. The choroidal veins became apparent at 16.2 ± 4.1 s alongside the choroidal arteries. Gradual fading of the choroidal vessels began 5.8 ± 1.5 min postdye administration and diffuse fluorescence of the fundus appeared. Diffuse fluorescence of the optic disk faded at about 18.8 ± 2.9 min. Mean arterial blood pressure at 1 and 3 min after ICG administration showed no significant change when compared to pre-administration (P > 0.05). However, 5 min (P = 0.054) and 10 min (P < 0.05) postadministration, a significant drop in blood pressure occurred. The time lapse between FLUO administration and its appearance in the ocular fundus was 15.7 ± 3.8 s. Retinal veins became apparent at 22.0 ± 3.6 s alongside retinal arteries. At 31.2 ± 4.1 s, full venous fluorescence was visualized throughout the entire fundus. CONCLUSIONS: While FLUO angiography shows only the retinal vessels, ICG angiography enabled visualization of the choroidal vasculature. ICG angiography provides clear resolution while remaining reliable and simple; thus, a combination of ICG and FLUO angiography shows promise as a diagnostic aid for clinical evaluation of various chorioretinal diseases in cats.


Assuntos
Corioide/irrigação sanguínea , Angiofluoresceinografia/veterinária , Fundo de Olho , Verde de Indocianina , Animais , Pressão Arterial , Doenças do Gato/diagnóstico , Gatos , Oftalmopatias/diagnóstico , Oftalmopatias/veterinária , Disco Óptico/anatomia & histologia , Vasos Retinianos/anatomia & histologia
9.
J Vet Med Sci ; 78(3): 505-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26655769

RESUMO

The purpose of this study was to investigate the effects of refractive error on canine visual evoked potentials with pattern stimulation (P-VEP). Six normal beagle dogs were used. The refractive power of the recorded eyes was measured by skiascopy. The refractive power was corrected to -4 diopters (D) to +2 D using contact lens. P-VEP was recorded at each refractive power. The stimulus pattern size and distance were 50.3 arc-min and 50 cm. The P100 appeared at almost 100 msec at -2 D (at which the stimulus monitor was in focus). There was significant prolongation of the P100 implicit time at -4, -3, 0 and +1 D compared with -2 D, respectively. We concluded that the refractive power of the eye affected the P100 implicit time in canine P-VEP recording.


Assuntos
Doenças do Cão/fisiopatologia , Potenciais Evocados Visuais , Reconhecimento Visual de Modelos , Erros de Refração/veterinária , Animais , Cães , Feminino , Masculino , Retinoscopia/veterinária
10.
J Vet Med Sci ; 77(10): 1335-8, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26074341

RESUMO

The purpose of this study was to evaluate the dark adaptation time in canine electroretinography (ERG) using a contact lens electrode with a built-in LED. Twelve eyes of six normal laboratory beagle dogs were used and exposed to steady room light at 500 lux for 30 min for light adaption. ERG was recorded at different time points during dark adaptation in sedated and light-adapted beagles. The stimulus intensity was 0.0096 cd/m(2)/sec. The b-wave amplitude increased significantly until 25 min of dark adaptation, whereas no significant changes in amplitudes were observed after 30 min. Dark adaptation for more than 25 min would be necessary for accurate ERG in canine ERG using a contact lens electrode with a built-in LED.


Assuntos
Lentes de Contato/veterinária , Adaptação à Escuridão/fisiologia , Cães/fisiologia , Eletrorretinografia/veterinária , Retina/fisiologia , Animais , Eletrodos/veterinária , Luz
11.
J Vet Med Sci ; 77(2): 155-60, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25373729

RESUMO

The purpose of this study was to investigate the effects of sevoflurane concentration on canine visual evoked potentials with pattern stimulation (P-VEPs). Six clinically normal laboratory-beagle dogs were used. The minimum alveolar concentration (MAC) of sevoflurane was detected from all subjects by tail clamp method. The refractive power of the right eyes of all subjects was corrected to -2 diopters after skiascopy. For P-VEP recording, the recording and reference electrode were positioned at inion and nasion, respectively, and the earth electrode was positioned on the inner surface. To grasp the state of CNS suppression objectively, the bispectral index (BIS) value was used. The stimulus pattern size and distance for VEP recording were constant, 50.3 arc-min and 50 cm, respectively. P-VEPs and BIS values were recorded under sevoflurane in oxygen inhalational anesthesia at 0.5, 1.0, 1.5, 2.0, 2.5 and 2.75 sevoflurane MAC. For analysis of P-VEP, the P100 implicit time and N75-P100 amplitude were estimated. P-VEPs were detected at 0.5 to 1.5 MAC in all dogs, and disappeared at 2.0 MAC in four dogs and at 2.5 and 2.75 MAC in one dog each. The BIS value decreased with increasing sevoflurane MAC, and burst suppression began to appear from 1.5 MAC. There was no significant change in P100 implicit time and N75-P100 amplitude with any concentration of sevoflurane. At concentrations around 1.5 MAC, which are used routinely to immobilize dogs, sevoflurane showed no effect on P-VEP.


Assuntos
Anestésicos Inalatórios/farmacologia , Cães/fisiologia , Potenciais Evocados Visuais/efeitos dos fármacos , Éteres Metílicos/farmacologia , Reconhecimento Visual de Modelos/efeitos dos fármacos , Animais , Relação Dose-Resposta a Droga , Feminino , Masculino , Éteres Metílicos/administração & dosagem , Reconhecimento Visual de Modelos/fisiologia , Sevoflurano
12.
J Vet Sci ; 14(1): 77-84, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23388429

RESUMO

Electroretinography (ERG) is a well-established diagnostic procedure for objectively evaluating retinal function. In this study, ERG in beagle dogs, which are a popular experimental animal, was performed to determine the normal range of ERG variables and assess differences between the left and right eyes. ERG findings including rod, combined rod-cone, single-flash cone, and 30-Hz flicker responses were recorded with an LED-electrode in 43 sedated beagle dogs. The subjects were divided into young (< 1 year old), adult (1 ˜ 5 years old), and senile animals (≥ 6 years old). Normal ERG ranges were obtained. Significant differences in b-wave amplitude along with b/a ratio of the combined rod-cone response were found between the young and adult animals as well as young and senile dogs. No significant differences were observed between the left and right eyes. ERG variables in beagle dogs differed by age due to age-related retinal changes. Thus, we propose that normal ERG ranges should be determined according to age in each clinic and laboratory using its own equipment because each institution usually has different systems or protocols for ERG testing.


Assuntos
Cães/anatomia & histologia , Eletrorretinografia/veterinária , Envelhecimento , Animais , Eletrodos/veterinária , Eletrorretinografia/métodos , Feminino , Masculino
13.
J Vet Med Sci ; 73(7): 927-9, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21321477

RESUMO

We examined the refractive value in healthy Beagles by skiascopy. The mean refractive value of 54 eyes of 27 Beagles was 0.08 ± 0.87 (mean ± SD) diopters (D). The numbers of eyes defined as having emmetropia, myopia and hyperopia were 34, 8 and 12, respectively. Anisometropia was detected in 4 dogs. The mean refractive values in the 3-6-year-old and 8-9-year-old groups were 0.26 ± 0.84 and -0.29 ± 0.82 D, respectively, with a significant difference between the two groups (P<0.05).


Assuntos
Cães/anatomia & histologia , Olho/anatomia & histologia , Refração Ocular/fisiologia , Animais , Feminino , Masculino , Retinoscopia/veterinária
14.
Vet Ophthalmol ; 13(5): 289-93, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20840105

RESUMO

OBJECTIVE: To investigate disease in the fellow eye, and consider the relation to rhegmatogenous retinal detachment (RRD) in Shih-Tzus. ANIMALS STUDIED: The fellow eyes of 49 Shih-Tzus (27 male, 22 female; median age: 6.8 years) with unilateral RRD diagnosed by funduscopy or ultrasonography at Rakuno Gakuen University Teaching Animal Hospital were assessed in this study. PROCEDURES: Ophthalmic examinations (including menace response, pupillary light reflex, slit-lamp biomicroscopy, and funduscopy) were performed in the subjects. Electroretinography was performed in 12 eyes that developed retinal degeneration. Maximum follow-up period was 42 months. RESULTS: Cataracts and vitreous opacity were observed in 26 (53%) and 32 eyes (65%), respectively, by slit-lamp biomicroscopy. Retinal degeneration with various degrees of hyper-reflectivity of the tapetal fundus and/or attenuation of retinal vessels was observed in 35 eyes (71%) on funduscopy. A reduction of amplitude in rod, standard combined and 30 Hz flicker electroretinogram was detected in 5 (42%), 10 (83%), and 6 eyes (50%), respectively. During the follow-up period, RRD was detected in six eyes. CONCLUSION: Retinal degeneration was frequently detected by funduscopy and electroretinograms in the fellow eye in Shih-Tzus with RRD. In our subjects, vitreous degeneration was also observed frequently. It has been reported that peripheral retinal degeneration is one of the causes of RRD associated with vitreous degeneration in humans. We assume that primary retinal degeneration with secondary vitreous degeneration is one of the causes of RRD in Shih-Tzus.


Assuntos
Doenças do Cão/patologia , Descolamento Retiniano/veterinária , Animais , Cães , Feminino , Masculino , Descolamento Retiniano/patologia
15.
J Vet Med Sci ; 72(11): 1449-53, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20644341

RESUMO

The aim of this research was to evaluate the changes in the response of pattern-stimulated visual evoked potential (pVEP) with different pattern size, and demonstrate visual acuity from the minimum visual angle. pVEP was recorded from both eyes of six healthy beagles. Prior to pVEP recording, the dogs were sedated, and a traction fiber was used to prevent the eye from rolling down. The stimulator was set 30 cm from the subject's eye. Pattern reversal frequency of the stimulating monitor was 3 rev/sec, and pattern size was set at seven levels; 14-364 arc-min (1.2-31.4 mm). Amplitude of the P100 component was evaluated, and visual acuity was calculated from the minimum visual angle to obtain a pVEP response. A pVEP response (2.3-3.1 µV) was obtained from all subjects. The P100 component was detectable in 3 eyes with a check size of 14 arc-min and 7 eyes with 28 arc-min, and the component was undetectable with 14 arc-min in all subjects in which it was undetectable with 28 arc-min. From the minimum level to obtain the P100 component, the subjects' visual acuity was extrapolated as 0.54-2.14 cycles per degree. We demonstrated the change in P100 component with check size. However, our technique was inadequate to examine visual acuity because the subject's refractive index was ignored. We suggest that, with further study, pVEP with different check sizes would be applicable for canine visual acuity examination.


Assuntos
Cães/fisiologia , Potenciais Evocados Visuais/fisiologia , Reconhecimento Visual de Modelos/fisiologia , Acuidade Visual , Animais , Calibragem , Sedação Consciente/métodos , Sedação Consciente/veterinária , Feminino , Masculino , Valores de Referência , Retina/fisiologia
16.
J Vet Med Sci ; 70(2): 139-44, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18319573

RESUMO

Manganese deficiency results in neurological and skeletal defects, together with ultrastructural disarrangement of the retina in rats. Wild birds show a range of Mn concentrations in their tissues, including the liver, raising the possibility of Mn-related disorders in the wild. Electroretinography (ERG) provides a useful noninvasive approach to evaluate visual function. This method is especially useful in birds, as objective analysis of them is very difficult, while they have well-developed vision. In this study, we carried out a convenient and reliable ERG recording using a contact lens electrode with a built-in light source (LED electrode) of Japanese quail (Coturnix coturnix japonica) fed a Mn-deficient diet. After 10 min light adaptation, single-flash and flicker cone responses were reproducibly recorded to cause an intensity-dependent increase in amplitude of both a-wave and b-wave in single-flash ERG. Mn-deficient feeding markedly decreased the Mn concentration in the liver by almost half in 3 to 6 weeks, followed by body weight loss in 13 to 15 weeks. Implicit time of a-wave and b-wave cone response by single-flash stimulation was significantly delayed in quail with a Mn depletion from 3 to 6 weeks. Every cone response of the Mn-deprived quail had a tendency to decrease amplitude. The ultrastructure of cone photoreceptor cells was disorganized by Mn deficiency, including changes in outer segment discs of photoreceptor cells. These results suggest the essential role of Mn in the integrity of the retinal function of birds.


Assuntos
Coturnix , Eletrorretinografia/veterinária , Manganês/deficiência , Doenças das Aves Domésticas/patologia , Doenças Retinianas/veterinária , Ração Animal , Fenômenos Fisiológicos da Nutrição Animal , Animais , Lentes de Contato/veterinária , Dieta/veterinária , Eletrodos/veterinária , Eletrorretinografia/instrumentação , Retina/ultraestrutura , Doenças Retinianas/patologia
17.
Vet Ophthalmol ; 10(5): 308-12, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17760711

RESUMO

OBJECTIVE: The purpose of this study was to determine the effects of cataract stage, lens-induced uveitis and cataract removal on the electroretinogram (ERG) of dogs with cataract. ANIMALS STUDIED: Fifty-seven dogs diagnosed with unilateral or bilateral cataract whose ERG was recorded at Rakuno Gakuen University Teaching Animal Hospital from 2001 to 2004. PROCEDURES: Four responses were recorded during the ERG: rod ERG, standard combined ERG, single-flash cone ERG and 30-Hz flicker ERG. Cataracts were divided into four stages: incipient, immature, mature and hypermature, and with or without lens induced uveitis (LIU). Noncataractous eyes of dogs with unilateral cataract were used as the control. We compared ERG amplitude, implicit time, and the b- to a-wave amplitude ratio of cataractous vs. noncataractous eyes, preoperative vs. postoperative cataractous eyes, and cataractous eyes with and without LIU. RESULTS: No significant difference was found in ERG amplitude between incipient, immature and hypermature cataractous eyes, while in mature cataractous eyes decreased amplitude was confirmed in all responses compared with control eyes. However, no significant difference in b/a ratio was found at any stage of cataract. In postoperative eyes, increased amplitude was recorded in all responses compared to preoperative values. In eyes with LIU a decreased amplitude in the rod ERG and b-wave of standard combined ERG was recorded and, furthermore, a significant decline was confirmed in b/a ratio. CONCLUSION: ERG values were influenced by cataract stage and LIU. LIU was associated with a reduction in the b/a ratio.


Assuntos
Extração de Catarata/veterinária , Catarata/veterinária , Doenças do Cão/patologia , Eletrorretinografia/veterinária , Uveíte/veterinária , Animais , Catarata/patologia , Extração de Catarata/métodos , Extração de Catarata/normas , Cães , Eletrorretinografia/métodos , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Uveíte/etiologia , Uveíte/patologia
18.
J Vet Med Sci ; 69(5): 465-70, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17551217

RESUMO

In dogs, a variety of diseases of the retina and choroid have been reported, either separately or concomitantly; however, the canine choroid is difficult to evaluate by veterinary techniques currently available. Indocyanine green (ICG) angiography is widely used in human ophthalmology, but has not been investigated for use in canine ophthalmology. The aim of this study was to apply a new approach to ICG angiography and compare the resulting angiograms with fluorescein (FLUO) angiograms of the ocular fundus in dogs. With a fundus camera equipped with an infrared-sensitive charged coupled device (CCD), we performed angiography on eight healthy beagles under inhalation anesthesia. ICG angiography enabled clear visualization of the choroidal vasculature, whereas FLUO angiography showed only the retinal vessels. At 8.4 +/- 3.6 sec after administration of ICG dye into the cephalic vein, the choroidal arteries could be seen extending radially from the optic disc, then the choroidal veins became apparent at 10.2 +/- 4.1 sec, coursing alongside the choroidal arteries. Gradual fading of the choroidal vessels began 13.2 +/- 2.2 min after the dye was administered, and overall diffuse fluorescence of the fundus appeared. Diffuse fluorescence of the fundus continued after the choroidal vessels and optic disc faded at about 58.3 +/- 5.3 min from administration of the dye. In conclusion, ICG angiography provides clear resolution and is reliable and simple, thus offering promise as a diagnostic aid for clinical evaluation of the choroid in dogs.


Assuntos
Angiografia/veterinária , Corioide/irrigação sanguínea , Fundo de Olho , Verde de Indocianina , Vasos Retinianos/anatomia & histologia , Angiografia/métodos , Animais , Cães
19.
Vet Ophthalmol ; 8(6): 407-13, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16359364

RESUMO

It is difficult to detect discrete cone function with the present conventional electroretinography (ERG) examination. In this study, we developed contact electrodes with a built-in color (red (644 nm), green (525 nm), or blue (470 nm)) light source (color LED-electrode), and evaluated an experimental model of digoxin in the dog. First, 17 normal Beagle dogs were used to determine which electrode works well for color ERG measurement on dogs. Then, color ERG was performed on seven normal Beagle dogs at various points during a 14-day period of digoxin administration. A single daily dose of 0.0125 mg/kg/day, which is within the recommended oral maintenance dosage range for dogs, was administered orally for 2 weeks. Ophthalmic examination, measurement of plasma concentration of digoxin, and color ERG examination were performed. On first examination, amplitudes of all responses were significantly (P < 0.01) lower with the red, than with the blue and green electrodes during ERG recording. In ERG using the red electrode, the standard deviation was large. According to these preliminary results, the red electrode was not used in the experimental dog model with digoxin. In the digoxin administrated animals, no significant change was observed in the ophthalmic examination findings. The digoxin level increased steadily throughout the dosing period but was always within the therapeutic range for dogs. In rod ERG, no abnormalities were detected with any electrode. In standard combined ERG, decreased amplitude of the a-wave was detected with every electrode. In single flash cone ERG, prolongation of implicit time was detected by color ERG with the blue and green electrodes. In 30-Hz flicker ERG, decreased amplitude was detected only by color ERG with the blue electrode. The decreased amplitude and prolonged implicit time recovered after termination of digoxin administration. Cone dysfunction induced by digoxin in the dog was revealed by multicolor ERG using blue and green LED-electrodes. Multi-color ERG was useful for detecting cone type-specific dysfunction in the dog.


Assuntos
Defeitos da Visão Cromática/veterinária , Digoxina/administração & dosagem , Doenças do Cão/diagnóstico , Eletrorretinografia/veterinária , Administração Oral , Animais , Defeitos da Visão Cromática/diagnóstico , Digoxina/toxicidade , Cães , Relação Dose-Resposta a Droga , Eletrodos/veterinária , Eletrorretinografia/instrumentação , Eletrorretinografia/métodos , Masculino
20.
J Vet Med Sci ; 67(5): 509-14, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15942136

RESUMO

Electroretinography (ERG) is an effective method for the diagnosis of retinal disease. In the dog, dependable ERG recording is difficult without the use of an expensive device like a Ganzfeld full-field stimulator. The International Society for Clinical Electrophysiology of Vision has defined the standard flash stimulus condition (SF) and evaluation of the retina using the b/a ratio in humans. In dogs, evaluation using the b/a ratio has not been reported, whereas the intensity of SF has been defined. In this study, we performed a convenient ERG recording method using a contact lens electrode with a built-in light source (LED-electrode), and confirmed SF as reported previously. ERG recordings were performed on 15 healthy beagle dogs under sedation. We performed bilateral ERG at 12 different intensities after 30 min dark adaptation. After 10 min light adaptation, we recorded single flash cone and flicker cone response using the SF determined in this study. In this study, SF of 3.0 cd/m(2)/sec (6,000 cd/m(2), 0.5 msec) resulted in b/a=2. The intensity for rod response that recorded only the b-wave was 0.0096 cd/m(2)/sec (80 cd/m(2), 0.12 msec). We could achieve ERG for each response easily and smoothly under sedation, and without general anesthesia. Using an LED-electrode, we could perform more quantitative and reproducible ERG examinations than with traditional methods. We propose that the b/a ratio is the most useful parameter in ERG reporting for evaluating retinal function.


Assuntos
Lentes de Contato/veterinária , Cães , Eletrodos , Eletrorretinografia/veterinária , Animais , Eletrorretinografia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...