Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Polymers (Basel) ; 16(9)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38732688

RESUMO

This study evaluated the effect of simulated pulpal pressure (SPP) conditions and storage time on contemporary adhesive systems' microtensile bond strength (µTBS) to dentin. Extracted human molars were prepared and randomly divided into four groups according to the adhesives: Clearfil Megabond 2 (CSE), Beautibond Xtreme Universal (BXU), G2-Bond (G2B), and Scotchbond Universal Plus (SBP). Each adhesive group was further divided following the SPP conditions: control with no simulation (SPP-CTR), SPP with distilled water (SPP-DTW), and SPP with fetal bovine serum (SPP-FBS). Resin composite build-ups were prepared, and teeth were stored in water (37 °C) for 24 h (24 h) and 3 months (3 m). Then, teeth were sectioned to obtain resin-dentin bonded beams and tested to determine the µTBS. Data were analyzed using three-way ANOVA, Tukey post hoc tests (=0.05), and Weibull failure analysis. Failure mode was observed using scanning electron microscopy. The µTBS response was affected by adhesive systems, simulated pulpal pressure conditions, and storage time. SPP-CTR groups presented a higher overall bond strength than SPP-DTW and SPP-FBS, which were not significantly different from each other. Only for SBP, the SPP-FBS group showed higher µTBS than the SPP-DTW group. The Weibull analysis showed that the bonding reliability and durability under SPP-DTW and SPP-FBS were inferior to SPP-CTR, and the 24 h bonding quality of adhesives to dentin was superior to that of 3 m. SPP drastically reduced the µTBS of all adhesives to dentin regardless of solution (distilled water or fetal bovine serum). Storage after 3 m also decreased µTBS despite the SPP condition.

2.
Polymers (Basel) ; 14(21)2022 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-36365534

RESUMO

This study aimed to use quantitative and qualitative evaluations based on micro-tensile bond strength (µTBS) to clarify the appropriate immediate dentin sealing (IDS) approach for improving the bonding of CAD/CAM ceramic crown restorations. Forty-eight extracted human molars were prepared to obtain standardized abutment specimens and divided into three groups: no IDS (group C: control), IDS performed by a single application of an all-in-one adhesive system (group A), and IDS performed by the combined application of an adhesive system and a flowable resin composite (group F). All specimens were restored with a ceramic crown fabricated by a chair-side CAD/CAM system and were divided into no-stress and stressed groups. After cyclic loading (78.5 N; total, 3 × 105 cycles; 90 cycles/min) on the specimens in the stressed group, all specimens were sectioned. The µTBS values for the occlusal and mesioaxial walls were measured (n = 16) and analyzed statistically. The quantitative bonding performance of groups A and F were superior to that of group C, regardless of the cyclic loading and abutment wall conditions. Group F showed the maximum bond strength and the highest bond durability in the qualitative bonding performance even under the cyclic loading condition simulating clinical mastication.

3.
Diagnostics (Basel) ; 12(6)2022 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-35741232

RESUMO

The accurate diagnosis of individual tooth prognosis has to be determined comprehensively in consideration of the broader treatment plan. The objective of this study was to establish an effective artificial intelligence (AI)-based module for an accurate tooth prognosis decision based on the Harvard School of Dental Medicine (HSDM) comprehensive treatment planning curriculum (CTPC). The tooth prognosis of 2359 teeth from 94 cases was evaluated with 1 to 5 levels (1-Hopeless, 5-Good condition for long term) by two groups (Model-A with 16, and Model-B with 13 examiners) based on 17 clinical determining factors selected from the HSDM-CTPC. Three AI machine-learning methods including gradient boosting classifier, decision tree classifier, and random forest classifier were used to create an algorithm. These three methods were evaluated against the gold standard data determined by consensus of three experienced prosthodontists, and their accuracy was analyzed. The decision tree classifier indicated the highest accuracy at 0.8413 (Model-A) and 0.7523 (Model-B). Accuracy with the gradient boosting classifier and the random forest classifier was 0.6896, 0.6687, and 0.8413, 0.7523, respectively. Overall, the decision tree classifier had the best accuracy among the three methods. The study contributes to the implementation of AI in the decision-making process of tooth prognosis in consideration of the treatment plan.

4.
Materials (Basel) ; 14(20)2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-34683637

RESUMO

Incremental techniques are always required for clinical cases of deep and/or large cavities restored with resin composite materials. The purpose of this study was to examine the bonding states of class 2 direct resin composite restoration applied by various incremental techniques after cyclic loading to simulate the intra-oral environment to define the appropriate technique. Three types of resin composites, namely, bulk-fill (B), flowable (F), and conventional resin composite (C), were applied to standardized class 2 cavities by incremental techniques with single- or bi-resin restoratives. After cyclic loading, the micro-tensile bond strength (µ-TBS) of the dentin cavity floor was measured. The Weibull modulus and Weibull stress values at 10%/90% probability of failure were analyzed. Single-resin incremental restorations with B or F and bi-resin incremental restorations with F + B and F + C demonstrated superior µ-TBS (quantitative ability), bonding reliability, and durability (qualitative ability) compared with the single-resin restoration with C (as control). Furthermore, F + B and F + C restoration yielded an excellent performance compared with the single-resin restorations with B, F, and C. In particular, the F + C restoration, which indicates not only the maximum mean µ-TBS, but also the highest values of the Weibull parameters, may be the optimal restoration method, including the esthetic benefits.

5.
Dent Mater J ; 40(4): 994-1006, 2021 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-33827999

RESUMO

The effects of space setting values and restorative materials on the bonding of metal-free CAD/CAM onlay restoration were examined quantitatively and qualitatively. Seventy-two standardized MODB onlay cavities, prepared using human molars were restored under nine conditions, based on three space setting values, Increased (IC), Standard (SC, control), Decreased (DC), and three restorative block materials, resin-composites (RC), lithium disilicate glass-ceramics (LD), Feldspar ceramics (FC, control). All the restored specimens were subjected to cyclic loading and thereafter the microtensile bond strength (µ-TBS) was measured and analyzed statistically. The effect of space setting value on the µ-TBS varied with the restorative material. The bonding reliability of RC and the bonding durability of LD were significantly superior to FC. The bonding characteristics of RC under IC and DC were similar to those under SC. LD under DC and FC under IC were effective in obtaining an excellent bonding reliability relative to their SC.


Assuntos
Colagem Dentária , Cimentos de Resina , Cerâmica , Desenho Assistido por Computador , Porcelana Dentária , Análise do Estresse Dentário , Humanos , Teste de Materiais , Reprodutibilidade dos Testes , Propriedades de Superfície , Resistência à Tração
6.
Dent Mater J ; 39(6): 1022-1032, 2020 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-32727963

RESUMO

The effect of differences in the type of restoration and adhesive resin cement system on the bonding of CAD/CAM ceramic restoration after cyclic loading was examined quantitatively and qualitatively. Seventy-two human maxillary first molars were divided into three restoration groups: MOD-inlay, MODP-onlay, and crown. Immediate dentin sealing was applied to the exposed dentin of all prepared specimens. The 24 specimens of each restoration group were further divided into another three groups, and a different adhesive resin cement system was applied to each group for cementation. All restoratives were fabricated from feldspathic-ceramic-blocks and cemented with each adhesive resin cement system according to the manufacturer's instructions. The microtensile bond-strength was measured after cyclic loading and was not significantly affected by differences in the type of restoration or adhesive resin cement system. However, the type of restorations and adhesive resin cement systems did show significant differences in terms of the bonding reliability.


Assuntos
Colagem Dentária , Cimentos de Resina , Cerâmica , Cimentos Dentários , Análise do Estresse Dentário , Dentina , Humanos , Teste de Materiais , Reprodutibilidade dos Testes , Propriedades de Superfície , Resistência à Tração
7.
Dent Mater J ; 38(6): 970-980, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31434832

RESUMO

This study examined the influences of clinical application of immediate dentin sealing (IDS) and temporary restoration (TR) on prepared abutment surfaces on the bonding of computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic crown restorations after cyclic loading. Standardized abutments were prepared in 60 human mandibular premolars. Dentin surfaces of half of the specimens were sealed with adhesive and flowable composite, while those of the other half were not sealed. A half of both sealed and non-sealed specimens were restored using a temporary cement and temporary crown. Each individual CAD/CAM ceramic crown was fabricated and cemented to an individual abutment. The restored specimens were subjected to cyclic loading, and the micro tensile bond strengths (µ-TBS) were measured. IDS contributed to an increase in the bond strength, whereas TR did not affect the bond strength. IDS restoration without TR yielded the maximum bond reliability in achieve specific µ-TBS values for the restoration and ensuring durability against debonding.


Assuntos
Colagem Dentária , Adesivos Dentinários , Desenho Assistido por Computador , Coroas , Análise do Estresse Dentário , Dentina , Humanos , Teste de Materiais , Reprodutibilidade dos Testes , Cimentos de Resina , Resistência à Tração
8.
J Nanobiotechnology ; 17(1): 34, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30823919

RESUMO

Natural teeth are supported by connective tissue collagen fibers that insert perpendicularly in the tooth cementum. Perpendicular insertion plays an important role in the maintenance of the junction between the oral epithelium and the periodontal connective tissue. Most titanium dental implant surfaces have no micro or macro structure to support perpendicularly oriented collagen attachment. Without this tight biologic seal to resist bacterial invasion and epithelial downgrowth, progressive bone loss in peri-implantitis is seen around dental implants. The purpose of this study was to establish the perpendicularly oriented collagen attachment to titanium oxide nanotube (TNT), and to assess its binding stability. TNT was prepared on the titanium-surface by anodization. Scanning electron microscopy (SEM) showed a regularly aligned TNT with an average 67 nm-diameter when anodized at 30 V for 3 h. Subsequently, collagen type I (CoI) was electrophoretically fused to anodic TNT in native polyacrylamide gel system where negatively charged CoI-C term was perpendicularly navigated to TNT. SEM and atomic force microscopy (AFM) were used to analyze CoI on the TiO2 and TNT surface. Several tens of nanometers of CoI protrusion were recorded by AFM. These protrusions may be long enough to be priming sites for cell-secreted CoI. CoI laid parallel to the titanium surface when fused by a chemical linker. Binding resistance of CoI against drastic ultrasonication was measured by Fourier-transform infrared spectroscopy attenuated total reflection (FTIR-ATR). The electrophoretically fused CoI in the titanium nanotube (TNT-CoIEPF) showed the significantly greatest binding resistance than the other groups (P < 0.01, a 1-way ANOVA and Tukey HSD post hoc test). Furthermore, TNT-CoIEPF surface rejected epithelial cell stretching and epithelial sheet formation. Chemically linked horizontal CoI on titanium oxide (TiO2) facilitated epithelial cell stretching and sheet formation.


Assuntos
Colágeno Tipo I/química , Tecido Conjuntivo/química , Implantes Dentários , Nanotubos/química , Titânio/química , Materiais Biocompatíveis/química , Adesão Celular/efeitos dos fármacos , Técnicas Eletroquímicas , Células Epiteliais/efeitos dos fármacos , Humanos , Tamanho da Partícula , Propriedades de Superfície
9.
PLoS One ; 11(10): e0164693, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27741287

RESUMO

The aim of this study was to produce epithelial attachment on a typical implant abutment surface of smooth titanium. A challenging complication that hinders the success of dental implants is peri-implantitis. A common cause of peri-implantitis may results from the lack of epithelial sealing at the peri-implant collar. Histologically, epithelial sealing is recognized as the attachment of the basement membrane (BM). BM-attachment is promoted by activated platelet aggregates at surgical wound sites. On the other hand, platelets did not aggregate on smooth titanium, the surface typical of the implant abutment. We then hypothesized that epithelial BM-attachment was produced when titanium surface was modified to allow platelet aggregation. Titanium surfaces were coated with a protease activated receptor 4-activating peptide (PAR4-AP). PAR4-AP coating yielded rapid aggregation of platelets on the titanium surface. Platelet aggregates released robust amount of epithelial chemoattractants (IGF-I, TGF-ß) and growth factors (EGF, VEGF) on the titanium surface. Human gingival epithelial cells, when they were co-cultured on the platelet aggregates, successfully attached to the PAR4-AP coated titanium surface with spread laminin5 positive BM and consecutive staining of the epithelial tight junction component ZO1, indicating the formation of complete epithelial sheet. These in-vitro results indicate the establishment of epithelial BM-attachment to the titanium surface.


Assuntos
Peptídeos/química , Receptores de Trombina/metabolismo , Titânio/química , Plaquetas/citologia , Plaquetas/metabolismo , Adesão Celular/efeitos dos fármacos , Moléculas de Adesão Celular/metabolismo , Células Cultivadas , Materiais Revestidos Biocompatíveis/farmacologia , Citocinas/metabolismo , Implantes Dentários , Células Epiteliais/citologia , Células Epiteliais/metabolismo , Células Epiteliais/ultraestrutura , Gengiva/citologia , Humanos , Imuno-Histoquímica , Microscopia Eletrônica de Varredura , Ativação Plaquetária/efeitos dos fármacos , Agregação Plaquetária/efeitos dos fármacos , Receptores de Trombina/química , Propriedades de Superfície , Proteína da Zônula de Oclusão-1/metabolismo , Calinina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...