Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 20(1-2): 263-9, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10704031

RESUMO

An enzymatic amperometric procedure for measurement of mercury(II) in pharmaceuticals, based on the inhibition of invertase and on a glucose electrode was studied. Analytical parameters for measurements in batch and flow injection analysis (FIA) have been optimised. Mercury(II) was detected in the 10-60 ppb range with RSD < or =2%. A sample throughput of 6 h(-1) for batch and 15 h(-1) for FIA was obtained. The total mercury(II) from thimerosal (thiomersal, sodium ethylmercurithiosalicylate) in eye-drop samples was measured with the amperometric procedure after oxidative cleavage treatment. Results for both batch and FIA procedures correlated well with atomic absorbtion spectroscopy (AAS) data.


Assuntos
Técnicas Biossensoriais , Inibidores Enzimáticos/farmacologia , Glicosídeo Hidrolases/antagonistas & inibidores , Mercúrio/análise , Cromatografia Líquida de Alta Pressão , Eletroquímica , Enzimas Imobilizadas , Análise de Injeção de Fluxo , Glucose/análise , Indicadores e Reagentes , Mercúrio/farmacologia , Espectrofotometria Atômica , Sacarose/análise , beta-Frutofuranosidase
2.
Clin Chem ; 24(3): 448-50, 1978 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-630706

RESUMO

We describe a new, nonenzymatic method for determining serum glucose. This method is based upon the direct electrochemical oxidation of glucose by means of stable nickel-catalyst that is electrodeposited onto a lead dioxide electrode surface. Linear calibration plots are obtained for glucose in the 0.1 to 4500 mg/liter range. Values for 23 sera with glucose concentrations ranging from 300 to 4300 mg/liter showed a linear correlation coefficient of 0.996 when compared with values reported by a hospital laboratory using the hexokinase method. Typically a 25-microliter sample is used, but samples as small as 5 microliter have been successfully analyzed. The sample is added to 25.00 ml of pH 13 electrolyte containing 1 mmol of NiSO4 per liter; the amount of increase in anodic current comproses the analytical signal. For 20 repetitive analyses of a serum specimen, the CV was less than 4%. Ascorbic acid is rapidly decomposed in the electrolyte used and thus does not interfere. Uric acid is inactive at the concentrations present in serum samples. The sensitivity and simplicity of the new method suggest it as an alternative to currently available procedures.


Assuntos
Glicemia/análise , Catálise , Eletrodos , Humanos , Métodos , Níquel , Oxirredução , Potenciometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...