Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Infection ; 50(4): 1019-1022, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34652626

RESUMO

PURPOSE: The aim of this study was to assess respiratory function at the time of clinical recovery, 6 weeks, 6 months, and 12 months after discharge in patients surviving to COVID-19 pneumonia. METHODS: Our case series consisted of 13 hospitalized patients with COVID-19 pneumonia. RESULTS: Baseline pulmonary function tests were 55.7 ± 15.6 for FEV1%, 68.6 ± 16.0 for FVC%, and 1.2 ± 0.1 for FEV1/FVC%. Although pulmonary function showed a small improvement after 6 weeks, patients experienced a more significant improvement after 6 and 12 months in FEV1% (95.4 ± 13.7 and 107.2 ± 16.5, respectively; p < 0.001), FVC% (91.3 ± 14.5, and 105.9 ± 15.6, respectively; p < 0.001), and FEV1/FVC% values (1.04 ± 0.04, and 1.01 ± 0.05, respectively; p < 0.001). CONCLUSION: COVID-19 pneumonia may result in significant alterations in lung function, with a mainly restrictive pattern, partly persisting at 6 weeks after recovery from acute phase, but significantly improving during a 12-month follow-up period.


Assuntos
COVID-19 , COVID-19/complicações , Volume Expiratório Forçado , Humanos , Pulmão/diagnóstico por imagem , Testes de Função Respiratória , Espirometria
2.
Infection ; 49(1): 153-157, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32725597

RESUMO

PURPOSE: The aim of our study was to assess respiratory function at the time of clinical recovery and 6 weeks after discharge in patients surviving to COVID-19 pneumonia. METHODS: Our case series consisted of 13 patients with COVID-19 pneumonia. RESULTS: At the time of clinical recovery, FEV1 (2.07 ± 0.72 L) and FVC (2.25 ± 0.86 L) were lower compared to lower limit of normality (LLN) values (2.56 ± 0.53 L, p = 0.004, and 3.31 ± 0.65 L, p < 0.001, respectively), while FEV1/FVC (0.94 ± 0.07) was higher compared to upper limit of normality (ULN) values (0.89 ± 0.01, p = 0.029). After 6 weeks pulmonary function improved but FVC was still lower than ULN (2.87 ± 0.81, p = 0.014). CONCLUSION: These findings suggest that COVID-19 pneumonia may result in clinically relevant alterations in pulmonary function tests, with a mainly restrictive pattern.


Assuntos
COVID-19/fisiopatologia , Tosse/fisiopatologia , Dispneia/fisiopatologia , Febre/fisiopatologia , Pulmão/fisiopatologia , SARS-CoV-2/patogenicidade , Adulto , Idoso , COVID-19/diagnóstico , COVID-19/patologia , COVID-19/virologia , Tosse/diagnóstico , Tosse/patologia , Tosse/virologia , Dispneia/diagnóstico , Dispneia/patologia , Dispneia/virologia , Feminino , Febre/diagnóstico , Febre/patologia , Febre/virologia , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Pulmão/virologia , Masculino , Pessoa de Meia-Idade , Testes de Função Respiratória , Espirometria , Tomografia Computadorizada por Raios X
3.
BMC Pulm Med ; 14: 194, 2014 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-25476922

RESUMO

BACKGROUND: To evaluate noninvasive ventilation (NIV) in diffuse interstitial lung diseases (DILD) patients with acute respiratory failure (ARF) according to baseline radiological patterns and the etiology of ARF. METHODS: In a multicenter, observational, retrospective study, consecutive DILD patients undergoing NIV because of an episode of ARF were evaluated in six Italian high dependency units. Three groups of patients were identified based on the etiology of ARF: those with pneumonia (Group A), those with acute exacerbation of fibrosis, (Group B) and those with other triggers (Group C). Clinical failure was defined as any among in-hospital mortality, endotracheal intubation and extra-corporeal membrane oxygenation use. RESULTS: Among the 60 patients enrolled (63% males; median age: 71 years), pneumonia (42%) and acute exacerbation of fibrosis (39%) were the two most frequent causes of ARF. A significant increase of PaO2/FiO2 ratio during NIV treatment was detected in Group A (p = 0.010), but not in Group B. No significant difference in PaO2/FiO2 ratio, PaCO2 and pH values during NIV treatment was detected in patients with a radiological pattern of usual interstitial pneumonia (UIP) and non-specific interstitial pneumonia (NSIP). 22 patients (37%) suffered for a clinical failure. No significant differences in the study outcome were detected in Group A vs. Group B, as well as among patients with a radiological pattern of UIP vs. NSIP CONCLUSIONS: NIV treatment should be individualized in DILD patients with ARF according to the etiology, but not the baseline radiological pattern, in order to improve oxygenation.


Assuntos
Fibrose Pulmonar Idiopática/complicações , Ventilação não Invasiva , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia , Doença Aguda , Idoso , Pneumonia em Organização Criptogênica/complicações , Pneumonia em Organização Criptogênica/diagnóstico por imagem , Feminino , Humanos , Fibrose Pulmonar Idiopática/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Oxigênio , Pressão Parcial , Pneumonia/complicações , Pneumonia/diagnóstico por imagem , Troca Gasosa Pulmonar , Radiografia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...