1.
J Hand Surg Asian Pac Vol ; 22(3): 320-328, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28774241

RESUMO

BACKGROUND: In order to introduce new pharmacological agents with the intent to inhibit the adhesion formation, it is important to test such products on laboratory animals under a protocol that can evaluate the quantitative and qualitative aspects of healing of the tendons. Most experimental models focus on the tensile strength and histological analysis of the tendons, failing to sufficiently quantify the degree of the adhesion formation. METHODS: The experiment included six male New Zealand rabbits that underwent surgery of their right forepaws. The deep flexor tendon of the middle finger was transected and repaired and after six weeks the rabbits were killed. In order to assess the extent of adhesions, the functional stiffness of the tendons and the range of motion of the specimens' fingers was studied using a tensile testing machine. The setup used allowed the simultaneous recording of the specimens' motion and the pulling force values. RESULTS: The mean values of the left and right forepaws were expressed in the same chart showing a clear difference between the operated and non operated forepaws. CONCLUSIONS: Using a relatively simple set up in the laboratory we had the chance to focus on a more elaborate analysis of the data with the help of low cost and accessible software.


Assuntos
Traumatismos dos Tendões/fisiopatologia , Tendões/fisiologia , Resistência à Tração/fisiologia , Aderências Teciduais/fisiopatologia , Animais , Fenômenos Biomecânicos/fisiologia , Modelos Animais , Coelhos , Amplitude de Movimento Articular/fisiologia
2.
Hippokratia ; 19(4): 352-255, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-27688701

RESUMO

During revision surgery of total hip arthroplasties, surgeons may come across the challenging complication of a proximally fractured femoral stem, which however maintains sufficient distal fixation. Such cases, although rare, are extremely demanding due to lack of available attachments that would assist surgical explantation of the broken implant. It is herein presented a metal sterilisable surgical tool designed for the removal of the femoral stem broken at the level of the "neck". Hippokratia 2015; 19 (4): 352-355.

3.
ISRN Orthop ; 2013: 328246, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24959355

RESUMO

The aim of this study was to provide a preliminary evaluation of the possible effect that femoral version may have on the bearing equilibrium conditions developed on the medial tibiofemoral compartment. A digital 3D solid model of the left physiological adult femur was used to create morphological variations of different neck-shaft angles (varus 115, normal 125, and valgus 135 degrees) and version angles (-10, 0, and +10 degrees). By means of finite element modeling and analysis techniques (FEM-FEA), a virtual experiment was executed with the femoral models aligned in a neutral upright position, distally supported on a fully congruent tibial tray and proximally loaded with a vertical only hip joint load of 2800 N. Equivalent stresses and their distribution on the medial compartment were computed and comparatively evaluated. Within our context, the neck-shaft angle proved to be of rather indifferent influence. Reduction of femoral version, however, appeared as the most influencing parameter regarding the tendency of the medial compartment to establish its bearing equilibrium towards posteromedial directions, as a consequence of the corresponding anteroposterior changes of the hip centre over the horizontal tibiofemoral plane. We found a correlation between femoral anteversion and medial tibiofemoral compartment contact pressure. Our findings will be further elucidated by more sophisticated FEM-FEA and by clinical studies that are currently planned.

4.
Injury ; 43(3): 266-71, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21371707

RESUMO

The aim of this laboratory work was to study the compressive and flexural characteristics of various commercially available bone graft substitute (BGS) ceramic cements, in their initial as-mixed condition, and compare them to polymethylmethacrylate (PMMA). The tested biomaterials were two different calcium phosphate cements, two different calcium sulphate cements, one nanocrystalline hydroxyapatite and one PMMA cement. All biomaterials were prepared according to manufacturers instructions and the methodology described in ISO 5833 (2002) for acrylic bone cement was followed, as the one closest approaching in vivo requirements. All BGS cements had a brittle behaviour and when subjected to mechanical stress they all failed under sudden crack propagations in their bulk. Both in compression and bending, all BGS cements failed under loads lower than those of PMMA. In compression, the calcium sulphate extra strength cement showed a strength value of approximately 60% of PMMA, the other cements following at a distance. In bending, all BGS cements showed strengths below 22% of PMMA. However, due to limited number and fragility of specimens, calculated bending strengths can only be considered as indicative figures with limited comparative value. The results of this in vitro study showed a varying mechanical performance between tested BGS ceramic cements, whilst all of them exhibited lower compression and bending strength than the selected PMMA. These findings, of course, cannot be directly extrapolated to surgical or clinical implications, since the adopted in vitro context does not necessarily reflect the actual in vivo conditions met by such biomaterials.


Assuntos
Materiais Biocompatíveis , Cimentos Ósseos , Substitutos Ósseos , Fosfatos de Cálcio , Durapatita , Teste de Materiais/métodos , Polimetil Metacrilato , Análise de Variância , Materiais Biocompatíveis/análise , Materiais Biocompatíveis/normas , Cimentos Ósseos/química , Cimentos Ósseos/normas , Substitutos Ósseos/química , Substitutos Ósseos/normas , Fosfatos de Cálcio/análise , Força Compressiva , Durapatita/análise , Elasticidade , Humanos , Projetos Piloto , Polimetil Metacrilato/análise , Estresse Mecânico
5.
Knee Surg Sports Traumatol Arthrosc ; 20(6): 1071-4, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21866350

RESUMO

UNLABELLED: We present a rare case of fracture of the modular femoral component in a varus-valgus constrained total knee arthroplasty (TKA) prosthesis which occurred 2 years after implantation. Both femoral and tibial components underwent a second revision using a constrained hinged TKA. Laboratory analysis revealed insufficient metaphyseal bone stock in association with inadequate cement mantle incorporation which made implant fixation solely reliant on the intramedullary stem construct. It was therefore hypothesized that high repetitive stresses over the junction of the modular component led to the fracture. LEVEL OF EVIDENCE: Case report, Level IV.


Assuntos
Artroplastia do Joelho/instrumentação , Prótese do Joelho , Falha de Prótese/etiologia , Idoso , Mau Alinhamento Ósseo/etiologia , Mau Alinhamento Ósseo/cirurgia , Feminino , Humanos , Instabilidade Articular/etiologia , Instabilidade Articular/cirurgia , Complicações Pós-Operatórias/cirurgia , Reoperação
6.
J Med Eng Technol ; 34(7-8): 448-54, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20858039

RESUMO

Ligament balancing during total knee arthroplasty (TKA) is a controllable and critical procedure necessary for the longevity of the prosthesis. Intraoperative knowledge of the magnitude and location of tibiofemoral forces, can guide the surgeon to an accurate balancing throughout the operation. We developed a novel sensor device in order to monitor tibiofemoral forces during TKA ligament balancing procedure. The device predicts loads with an error of ± 1.5%, following a linear trend of slope = 0.9933 and R(2) = 0.9987; while the location of load is predicted with a practically acceptable error of ± 0.5 mm. The device was subjected to a surgical validation with in situ application during simulated TKAs on composite and cadaveric knees, with a very satisfactory outcome and no operative time elongation. The device can be a useful intraoperative instrument for accurate TKA ligament balancing procedures based on objective and graphically demonstrated and recorded evidence.


Assuntos
Artroplastia do Joelho , Fenômenos Biomecânicos/fisiologia , Articulação do Joelho/fisiologia , Ligamentos Articulares/fisiologia , Modelos Biológicos , Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Desenho de Equipamento , Humanos , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Software , Cirurgia Assistida por Computador/instrumentação
7.
Hip Int ; 15(1): 12-20, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-28224577

RESUMO

A controversy exists regarding the results of cemented Ti-alloy femoral stems. Although most authors reported unfavourable results, there is no clear evidence of the exact reason for the increased failure rate. We studied 35 arthroplasties in 30 patients with a mean age at the time of surgery of 49.7 years (range 27 to 67 years). In most of them (23 hips) the pre-operative diagnosis was hip dysplasia or dislocation. The femoral component used in this study was the Optifix stem. Survival analysis showed a cumulative rate of success at nine years of 90.4% (15.3) with 25.5 femoral components remaining at risk. Three femoral components were retrieved during revision surgery: due to fatigue fracture, fracture of the femur and aseptic loosening respectively. Given that most publications refer to different designs of stems we presume that the problem could be focused on the design rather than the material or the method of fixation. Further information is necessary before Ti-alloy stems fixed with cement are withdrawn from use. (Hip International 2005; 15: 12-20).

8.
J Biomed Mater Res B Appl Biomater ; 66(1): 299-305, 2003 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-12808587

RESUMO

Failure of total hip arthroplasty femoral stems is a serious clinical complication. Even modern metal alloys and designs sometimes suffer such incidents. The reported study aimed at the investigation of the reasons leading the in vivo fracture of two Ti6Al4V femoral stems. Stems were retrieved during revision surgery approximately 2 years postoperatively. Examination and analysis included XRF spectrometry for identification of chemical composition, macroscopic examination and topographical measurements, SEM study of fracture surfaces, study of alloy microstructure by optical microscopy, and finally measurement of mechanical properties by means of tensile testing conducted on alloy samples machined from the stems themselves. Macroscopic examination and measurements showed close topographical similarity between the two fractures. XRF spectrometry, tensile testing, and microstructure analysis identified the alloy as a typical Ti6Al4V surgical titanium alloy. During SEM analysis the fracture surfaces exhibited characteristic fatigue striations tidally running on the cross sections, which were considered as the weakest ones regarding toward geometry and stress concentration. Fracture in both stems occurred due to fatigue along these cross sections.


Assuntos
Materiais Biocompatíveis , Prótese de Quadril , Falha de Prótese , Titânio , Adulto , Idoso , Ligas , Fenômenos Biomecânicos , Análise de Falha de Equipamento , Feminino , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Espectrometria por Raios X
9.
J Biomed Mater Res B Appl Biomater ; 64(1): 6-12, 2003 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-12474241

RESUMO

A 1/4-in.diameter two-column Isola spinal system implanted in a 13-year-old girl suffering from cerebral palsy and a severe neuromuscular scoliosis of 120 degrees, was replaced 22 months after primary implantation. The system was removed due to fracture of the lower left (concave) bar, between its two cross connectors (i.e., the distal bypass connector and a transverse cross link), as a result of a postoperative infection and a subsequently developed pseudarthrosis. The retrieved implants were analyzed with the use of a multitechnique characterization procedure involving macroscopic and microscopic examination, micro-multiple internal reflectance FTIR spectroscopy, X-ray fluorescence (XRF) spectrometry, roughness measurement, and mechanical testing of the constituent material and components. Findings suggest that the spinal system failed due to in vivo loosening of a two-set screw tandem connector and subsequent overloading of the contralateral bar.


Assuntos
Análise de Falha de Equipamento , Próteses e Implantes , Escoliose/cirurgia , Adolescente , Feminino , Humanos , Espectroscopia de Infravermelho com Transformada de Fourier , Fusão Vertebral
10.
J Endod ; 28(5): 367-70, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12026921

RESUMO

The aim of this study was to examine the current status of standardization of endodontic instruments. Measurements of instrument dimensions were conducted on stainless steel H- and K-files (sizes 08-40), as well as on rotary-driven nickel titanium (NiTi) files (sizes 15-40), to determine the incidence and degree of deviation from ISO 3630-1, 1992 specification. In addition, the dimensions of sets of H- and K-files (sizes 08-25) were measured to identify discrepancies in dimensions among instruments within the same size per manufacturer. The percentage of difference in width were used to determine the graduation from each size to the next. None of the files tested complied with the ISO nominal size. All files were within the ISO tolerance limits. However, under such tolerance limits, there is a high possibility of either sizes overlapping or of great differences between two sequential sizes. These results may explain the clinical difficulty found in negotiating narrow and curved canals and may establish the need for a more comprehensive approach on the evaluation methods used in root-canal instrument dimension specifications.


Assuntos
Instrumentos Odontológicos/normas , Preparo de Canal Radicular/instrumentação , Desenho de Equipamento/normas , Humanos , Níquel , Aço Inoxidável , Titânio
11.
J Biomed Mater Res ; 58(5): 593-8, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11505434

RESUMO

Retrieval analyses of alumina-alumina THA components are conducted in order to investigate in vivo wear of implants and provide guidance to material and design improvements. The contribution of the present study consists of the examination, by digital recording of spherical profiles and scanning electron microscopy, of four matched pairs of ceramic THA implants retrieved after 5, 11, 13, and 13 years in service because of mechanical loosening. Maximum wear depth values on measured surfaces ranged between 10-325 microm for heads and 25-784 microm for cups, while grossly worn areas varied between 240 and 1510 mm(2) for heads and 250 and 1570 mm(2) for cups. The greatest wear characteristics were demonstrated by the pair that served for 5 years, that is, on the cup that was found in a 65 degrees inclination. Quantitative topographical study of the results provided concrete evidence of a cascade of detrimental wear events of changing geometry, intensity, and progression associated with gradual cup tilting. Microscopy findings support previously recognized wear mechanisms.


Assuntos
Artroplastia de Quadril/efeitos adversos , Acetábulo , Adulto , Idoso , Óxido de Alumínio , Materiais Biocompatíveis , Cerâmica , Feminino , Seguimentos , Humanos , Análise por Pareamento , Teste de Materiais , Microscopia Eletrônica de Varredura , Próteses e Implantes/efeitos adversos , Desenho de Prótese , Falha de Prótese , Reoperação , Propriedades de Superfície , Fatores de Tempo
12.
J Biomed Mater Res ; 48(3): 365-73, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10398042

RESUMO

The articular surfaces of 10 retrieved ultrahigh molecular weight polyethylene acetabular sockets were studied by optical microscopy, X-ray fluorescence spectrometry, multiple internal reflectance FTIR spectroscopy, scanning electron microscopy, and wavelength dispersive X-ray microanalysis. The results revealed characteristic wear patterns including polishing, scratching, pitting, cratering, folding, shredding, burnishing, cracking, embedding of particles, and development of acquired biofilms with various degrees of mineralization. The biofilms formed were mainly of proteinaceous origin, and mineralized regions were composed of calcium phosphates with carbonate impurities. The crystallinity of the polyethylene at the articular surfaces was enhanced compared to the bulk, which was possibly due to the cold work produced in vivo. The mineralized regions were classified into two groups based on the grey levels of the backscattered images obtained. The high-contrast regions that were mainly composed of Ca and P with traces of Al and Si were associated with bone fragments; the low-contrast regions composed of K, Na, Ca, Mg, Si, Al, Fe, Cl, and P were associated with acquired biofilm calcification, which implies the active engagement of biofilms in the long term performance of acetabular sockets in vivo.


Assuntos
Artroplastia de Quadril , Materiais Biocompatíveis , Bioprótese , Polietilenos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Propriedades de Superfície
13.
J Rehabil Res Dev ; 36(3): 164-72, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10659799

RESUMO

Observations in the field of lower limb prosthetic rehabilitation have shown that several transfemoral prostheses show signs of wear on some components of the knee unit. This is thought to be a result of severe loading developed during activities associated with kneeling. Some prostheses may have failed due to repetitive action of such loading. In order to determine the nature and magnitude of the loads developed during kneeling by persons with transfemoral amputation, and to investigate the influence of various prosthetic parameters, an analysis of the results of 162 tests in prosthetic knee hyperflexion was undertaken. The services of four males with amputation were enlisted. The measurements involved simultaneous use of two Kistler force platforms, a six-channel strain gauge transducer mounted on the prosthetic shank, and a data acquisition system. The critical loads for this configuration were found to be the shear force on the knee hinge, the shear force imposed by the knee chassis on the shin, and the bending moment tending to hyperflex the knee. These loads ranged from 0.6 to 6.2 kN, 0.9 to 6.7 kN, and from 18.3 to 155.7 Nm, respectively. To achieve a comfortable kneeling position, some prostheses permit foot rotation about the pylon axis of 90 infinity to allow the shank to be approximately parallel to the ground. Tests were also conducted with the prostheses in this configuration and the most influential prosthetic parameter was found to be the external rotation of the foot (toe-out angle). During kneeling, it was found that the loading was dependent upon the position of the torso relative to the prosthesis, but loads were much higher than those developed during level walking.


Assuntos
Membros Artificiais/efeitos adversos , Fêmur/cirurgia , Articulação do Joelho/fisiologia , Postura , Análise de Falha de Equipamento/métodos , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Amplitude de Movimento Articular , Rotação , Processamento de Sinais Assistido por Computador , Transdutores de Pressão , Caminhada , Suporte de Carga
14.
J Bone Joint Surg Br ; 80(1): 48-53, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9460952

RESUMO

We report the long-term radiological results of 58 total hip arthroplasties (THA) using the Charnley offset-bore acetabular socket. Wear was measured at four sites and radiolucent lines and possible migration were recorded. Four cups were retrieved at revision and were examined using light microscopy, SEM and X-ray microanalysis. At a mean follow-up of seven years the mean wear in the DeLee and Charnley zone I was 0.4 mm and in zone II 0.26 mm. The wear rate was 0.06 and 0.04 mm/year, respectively. Progression of radiolucent lines was seen in five cases (8.6%). Three sockets (5.2%) were revised because of aseptic migration at a mean follow-up of 9.8 years and one socket for infection at two years. The offset-bore acetabular cup had excellent wear behaviour and a low migration and revision rate. We recommend that it should be considered in THA since the use of small cups is increasing, particularly in revision cases.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo , Adulto , Idoso , Feminino , Seguimentos , Luxação do Quadril/cirurgia , Humanos , Pessoa de Meia-Idade , Desenho de Prótese , Resultado do Tratamento