Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Langmuir ; 35(43): 13853-13859, 2019 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-31585036

RESUMO

We have developed a new spray-based method for characterizing surface energies of planar, porous substrates. Distinct spray modes (electrospray versus electrostatic spray), from the porous substrates, occur in the presence of an applied DC potential after wetting with solvents of different surface tension. The ion current resulting from the spray process is maximized when the surface energy of the porous substrate approaches the surface tension of the wetting solvent. By monitoring the selected ion current (e.g., benzoylecgonine, m/z 290 → 168) with a mass spectrometer or the total ion current with an ammeter, we determined the solvent surface tension yielding the maximum ion current to indicate the surface energy of the solid. Detailed evaluations using polymeric substrates of known surface energies enabled effective calibration of the approach that resulted in the correct estimation of the surface energy of hydrophobic paper substrates prepared by gas-phase silanization. A three-parameter empirical model suggests that the experimentally observed ion current profile is governed by differential partitioning of analyte controlled by the interfacial forces between the wetting solvent and the porous substrate.

2.
Anal Chem ; 90(15): 9353-9358, 2018 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-29975501

RESUMO

It is well-known that 2D dried blood spots on paper offer a facile sample collection, storage, and transportation of blood. However, large volume requirements, possible analyte instability, and difficult sample recovery plague this method, lowering confidence in analyte quantification. For the first time, we demonstrate a new approach using 3D dried blood spheroids for stabilization of small volume blood samples, mitigating these effects without cold storage. Blood spheroids form on hydrophobic paper, preventing interaction between the sample and paper substrate, eliminating all chromatographic effects. Stability of the enzyme alanine transaminase and labile organic compounds such as cocaine and diazepam were also shown to increase in the spheroid by providing a critical radius of insulation. On-surface analysis of the dried blood spheroids using paper spray mass spectrometry resulted in sub-ng/mL limits of detection for all illicit drugs tested, representing 1 order of magnitude improvement compared with analysis from 2D dried blood spots.


Assuntos
Teste em Amostras de Sangue Seco/métodos , Temperatura , Alanina Transaminase/sangue , Cocaína/sangue , Diazepam/sangue , Estabilidade Enzimática , Humanos , Interações Hidrofóbicas e Hidrofílicas , Limite de Detecção
3.
Sci Rep ; 6: 35643, 2016 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-27767044

RESUMO

Metaldehyde is extensively used worldwide as a contact and systemic molluscicide for controlling slugs and snails in a wide range of agricultural and horticultural crops. Contamination of surface waters due to run-off, coupled with its moderate solubility in water, has led to increased concentration of the pesticide in the environment. In this study, for the first time, rapid analysis (<~1 minute) of metaldehyde residues in water is demonstrated using paper spray mass spectrometry (PS-MS). The observed precursor molecular ions of metaldehyde were confirmed from tandem mass spectrometry (MS/MS) experiments by studying the fragmentation patterns produced via collision-induced dissociation. The signal intensity ratios of the most abundant MS/MS transitions for metaldehyde (177 → 149 for protonated ion) and atrazine (221 → 179) were found to be linear in the range 0.01 to 5 ng/mL. Metaldehyde residues were detectable in environmental water samples at low concentration (LOD < 0.1 ng/mL using reactive PS-MS), with a relative standard deviation <10% and an R2 value >0.99, without any pre-concentration/separation steps. This result is of particular importance for environmental monitoring and water quality analysis providing a potential means of rapid screening to ensure safe drinking water.

4.
Analyst ; 141(12): 3866-73, 2016 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-27121269

RESUMO

Paper-based microfluidic channels were created from solid wax printing, and the resultant 2D wax-printed paper substrates were used for paper spray (PS) mass spectrometry (MS) analysis of small organic compounds. Controlling fluid flow at the tip of the wax-printed paper triangles enabled the use of lower spray voltages (0.5-1 kV) and extended signal lifetime (10 minutes) in PS-MS. High sensitivity (sub ng mL(-1) levels) and quantitation precision (<10% RSD) have been achieved in the analysis of illicit drugs in 4 µL of raw urine (fresh and dry), as well as corrosion inhibitors and pesticides in water samples. The reported study encourages the future development of disposable 3D microfluidic paper-based analytical devices, which function with simple operation but capable of on-chip analyte detection by MS; such a device can replace the traditional complex laboratory procedures for MS analysis to enable on-site in situ sampling with portable mass spectrometers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...