Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
3.
Eur Radiol ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38592419

RESUMO

Medical imaging is both valuable and essential in the care of patients. Much of this imaging depends on ionizing radiation with attendant responsibilities for judicious use when performing an examination. This responsibility applies in settings of both individual as well as multiple (recurrent) imaging with associated repeated radiation exposures. In addressing the roles and responsibilities of the medical communities in the paradigm of recurrent imaging, both the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) have issued position statements, each affirmed by other organizations. The apparent difference in focus and approach has resulted in a lack of clarity and continued debate. Aiming towards a coherent approach in dealing with radiation exposure in recurrent imaging, the IAEA convened a panel of experts, the purpose of which was to identify common ground and reconcile divergent perspectives. The effort has led to clarifying recommendations for radiation exposure aspects of recurrent imaging, including the relevance of patient agency and the provider-patient covenant in clinical decision-making. CLINICAL RELEVANCE STATEMENT: An increasing awareness, generating some lack of clarity and divergence in perspectives, with patients receiving relatively high radiation doses (e.g., ≥ 100 mSv) from recurrent imaging warrants a multi-stakeholder accord for the benefit of patients, providers, and the imaging community. KEY POINTS: • Recurrent medical imaging can result in an accumulation of exposures which exceeds 100 milli Sieverts. • Professional organizations have different perspectives on roles and responsibilities for recurrent imaging. • An expert panel reconciles differing perspectives for addressing radiation exposure from recurrent medical imaging.

4.
J Occup Environ Med ; 66(6): e230-e237, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38527177

RESUMO

BACKGROUND: US nuclear capable shipyard workers have increased potential for occupational radiation exposure. OBJECTIVE: The aim of the study is to examine solid tumor mortality risks at low doses. METHOD: 437,937 workers working from 1957 to 2004 at eight US shipyards were studied. RESULTS: Radiation workers with a median life-time dose at 0.82 mSv had a significantly lower solid tumor mortality risk (relative risk [RR]: 0.96, 95% confidence interval [CI]: 0.94-0.98) than nonradiation workers. Among 153,930 radiation workers, the RRs of solid tumors increased with increasing dose categories without statistical significance. The dose category >0-<25 mSv had significantly lower RR (0.95, 95% CI: 0.91-0.99) versus 0 dose and the excess relative risk was 0.05/100 mSv (95% CI: 0.01-0.08). CONCLUSIONS: Solid tumor risk might increase with radiation dose, but not linearly at low doses. Actual mortality risk may be dependent on dose received.


Assuntos
Neoplasias Induzidas por Radiação , Exposição Ocupacional , Humanos , Neoplasias Induzidas por Radiação/mortalidade , Exposição Ocupacional/efeitos adversos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Estados Unidos/epidemiologia , Doses de Radiação , Navios , Idoso , Doenças Profissionais/mortalidade , Neoplasias/mortalidade , Medição de Risco , Relação Dose-Resposta à Radiação
5.
Med Phys ; 51(4): 2424-2443, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38354310

RESUMO

BACKGROUND: Standards for image quality evaluation in multi-detector CT (MDCT) and cone-beam CT (CBCT) are evolving to keep pace with technological advances. A clear need is emerging for methods that facilitate rigorous quality assurance (QA) with up-to-date metrology and streamlined workflow suitable to a range of MDCT and CBCT systems. PURPOSE: To evaluate the feasibility and workflow associated with image quality (IQ) assessment in longitudinal studies for MDCT and CBCT with a single test phantom and semiautomated analysis of objective, quantitative IQ metrology. METHODS: A test phantom (CorgiTM Phantom, The Phantom Lab, Greenwich, New York, USA) was used in monthly IQ testing over the course of 1 year for three MDCT scanners (one of which presented helical and volumetric scan modes) and four CBCT scanners. Semiautomated software analyzed image uniformity, linearity, contrast, noise, contrast-to-noise ratio (CNR), 3D noise-power spectrum (NPS), modulation transfer function (MTF) in axial and oblique directions, and cone-beam artifact magnitude. The workflow was evaluated using methods adapted from systems/industrial engineering, including value stream process modeling (VSPM), standard work layout (SWL), and standard work control charts (SWCT) to quantify and optimize test methodology in routine practice. The completeness and consistency of DICOM data from each system was also evaluated. RESULTS: Quantitative IQ metrology provided valuable insight in longitudinal quality assurance (QA), with metrics such as NPS and MTF providing insight on root cause for various forms of system failure-for example, detector calibration and geometric calibration. Monthly constancy testing showed variations in IQ test metrics owing to system performance as well as phantom setup and provided initial estimates of upper and lower control limits appropriate to QA action levels. Rigorous evaluation of QA workflow identified methods to reduce total cycle time to ∼10 min for each system-viz., use of a single phantom configuration appropriate to all scanners and Head or Body scan protocols. Numerous gaps in the completeness and consistency of DICOM data were observed for CBCT systems. CONCLUSION: An IQ phantom and test methodology was found to be suitable to QA of MDCT and CBCT systems with streamlined workflow appropriate to busy clinical settings.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Fluxo de Trabalho , Tomografia Computadorizada de Feixe Cônico/métodos , Imagens de Fantasmas , Tomógrafos Computadorizados , Estudos Longitudinais
7.
Radiology ; 309(2): e222590, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37962507

RESUMO

Because ionizing radiation is widely used in medical imaging and in military, industry, and commercial applications, programmatic management and advancement in knowledge is needed, especially related to the health effects of low-dose radiation. The U.S. Congress in partnership with the U.S. Department of Energy called on the National Academies of Sciences, Engineering, and Medicine (NASEM) to develop a long-term strategic and prioritized agenda for low-dose radiation research. Low doses were defined as dose amounts less than 100 mGy or low-dose rates less than 5 mGy per hour. The 2022 NASEM report was divided into sections detailing the low-dose radiation exposure and health effects, scientific basis for radiation protection, status of low-dose radiation research, a prioritized radiation research agenda, and essential components of a low-dose radiation research program, including resources needed and recommendations for financial recourse. The purpose of this review is to summarize this report and examine the recommendations to assess how these pertain to the practice of radiology and medicine.


Assuntos
Proteção Radiológica , Radiologia , Humanos , Radiografia , Indústrias
9.
Int J Radiat Oncol Biol Phys ; 117(4): 1018-1027, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37364800

RESUMO

PURPOSE: This work describes the first implementation and in vivo study of ultrahigh-dose-rate radiation (>37 Gy/s; FLASH) effects induced by kilovoltage (kV) x-ray from a rotating-anode x-ray source. METHODS AND MATERIALS: A high-capacity rotating-anode x-ray tube with an 80-kW generator was implemented for preclinical FLASH radiation research. A custom 3-dimensionally printed immobilization and positioning tool was developed for reproducible irradiation of a mouse hind limb. Calibrated Gafchromic (EBT3) film and thermoluminescent dosimeters (LiF:Mg,Ti) were used for in-phantom and in vivo dosimetry. Healthy FVB/N and FVBN/C57BL/6 outbred mice were irradiated on 1 hind leg to doses up to 43 Gy at FLASH (87 Gy/s) and conventional (CONV; <0.05 Gy/s) dose rates. The radiation doses were delivered using a single pulse with the widths up to 500 ms and 15 minutes at FLASH and CONV dose rates. Histologic assessment of radiation-induced skin damage was performed at 8 weeks posttreatment. Tumor growth suppression was assessed using a B16F10 flank tumor model in C57BL6J mice irradiated to 35 Gy at both FLASH and CONV dose rates. RESULTS: FLASH-irradiated mice experienced milder radiation-induced skin injuries than CONV-irradiated mice, visible by 4 weeks posttreatment. At 8 weeks posttreatment, normal tissue injury was significantly reduced in FLASH-irradiated animals compared with CONV-irradiated animals for histologic endpoints including inflammation, ulceration, hyperplasia, and fibrosis. No difference in tumor growth response was observed between FLASH and CONV irradiations at 35 Gy. The normal tissue sparing effects of FLASH irradiations were observed only for high-severity endpoint of ulceration at 43 Gy, which suggests the dependency of biologic endpoints to FLASH radiation dose. CONCLUSIONS: Rotating-anode x-ray sources can achieve FLASH dose rates in a single pulse with dosimetric properties suitable for small-animal experiments. We observed FLASH normal tissue sparing of radiation toxicities in mouse skin irradiated at 35 Gy with no sacrifice to tumor growth suppression. This study highlights an accessible new modality for laboratory study of the FLASH effect.


Assuntos
Neoplasias , Lesões por Radiação , Animais , Camundongos , Raios X , Camundongos Endogâmicos C57BL , Radiografia , Radiometria
12.
J Appl Clin Med Phys ; 24(3): e13885, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36659841

RESUMO

The historic and ongoing evolution of the practice, technology, terminology, and implementation of programs related to quality in the medical radiological professions has given rise to the interchangeable use of the terms Quality Management (QM), Quality Assurance (QA), and Quality Control (QC) in the vernacular. This White Paper aims to provide clarification of QM, QA, and QC in medical physics context and guidance on how to use these terms appropriately in American College of Radiology (ACR) Practice Parameters and Technical Standards, generalizable to other guidance initiatives. The clarification of these nuanced terms in the radiology, radiation oncology, and nuclear medicine environments will not only boost the comprehensibility and usability of the Medical Physics Technical Standards and Practice Parameters, but also provide clarity and a foundation for ACR's clinical, physician-led Practice Parameters, which also use these important terms for monitoring equipment performance for safety and quality. Further, this will support the ongoing development of the professional practice of clinical medical physics by providing a common framework that distinguishes the various types of responsibilities borne by medical physicists and others in the medical radiological environment. Examples are provided of how QM, QA, and QC may be applied in the context of ACR Practice Parameters and Technical Standards.


Assuntos
Medicina Nuclear , Radioterapia (Especialidade) , Humanos , Radiografia , Controle de Qualidade , Física
13.
Radiology ; 307(1): e221263, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36511806

RESUMO

The U.S. National Council on Radiation Protection and Measurements (NCRP) conducted a retrospective assessment of the U.S. data, and the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) performed a similar worldwide assessment for 2009-2018 (with most data from 2014 to 2017). Using the data from those reports, the frequency of radiologic and nuclear medicine studies, annual collective, and per capita effective dose in the United States for 2016 were compared with worldwide estimates from 2009 to 2018. There were an estimated 691 million radiologic, CT, dental, and nuclear medicine studies performed in the United States in 2016, which represented 16.5% of the 4.2 billion performed worldwide. The United States also accounted for 74 million CT procedures (18% of the world's estimated total), 275 million conventional radiology procedures (11% of the world's total), 8.1 million interventional radiologic procedures (34% of the world's total), 320 million dental radiography procedures (29% of the world's total), and 13.5 million nuclear medicine procedures (34% of the world's total). The U.S. collective effective dose was 717 000 person-sieverts (17.6% of the world's total). The average annual individual effective dose in the United States was 2.2 mSv compared with 0.56 mSv worldwide. The United States accounts for a large and disproportionate share of global medical radiation procedures and collective effective dose, but use of CT has increased more in other countries compared with the United States.


Assuntos
Medicina Nuclear , Lesões por Radiação , Humanos , Estados Unidos , Doses de Radiação , Estudos Retrospectivos , Radiografia
14.
Radiat Res ; 2022 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-36520982

RESUMO

The linear, non-threshold (LNT) hypothesis of cancer induction derived from studies of populations exposed to moderate-to-high acute radiation doses may not be indicative of cancer risks associated with lifetime radiation exposures less than 100 mSv. The objective of this study was to examine risks and dose-response patterns of lymphohematopoietic cancer (LHC) and its types associated with low radiation exposure while adjusting for possible confounding factors. A retrospective cohort of 437,937 U.S. nuclear shipyard workers (153,930 radiation and 284,007 non-radiation workers) was followed from 1957 to 2011, with 3,699 LHC deaths observed. The risk of LHC in radiation workers was initially compared to the risk in non-radiation workers. Time dependent accumulated radiation dose, lagged 2 years, was used in categorical and continuous dose analysis among radiation workers to examine the LHC risks and possible dose-response relationships based on Poisson regression models. These analyses controlled for sex, race, time dependent age, calendar time, socioeconomic status, solvent-related last job, and age at first hire. The median lifetime radiation dose for the radiation worker population was 0.82 mSv and the 95th percentile dose was 83.63 mSv. The study shows: 1. LHC mortality for radiation workers was significantly lower than non-radiation workers relative risk: 0.927; 95% confidence intervals (95% CI): 0.865, 0.992; P = 0.030]. Among LHC types, the risks for lymphoid leukemia and lymphomas in radiation workers were lower than the risk in non-radiation workers with statistical significance, while the risk for the rest of LHC types did not show any statistically significant difference. 2. In categorical dose analysis among radiation workers, sample size weighted linear trend of relative risk (RRs) for LHC and its types in five dose categories (>0-<25, 25-<50, 50-<100, 100-<200, and > = 200 mSv) vs. 0 mSv were not statistically significant, although there was an elevation of RR for chronic myeloid leukemia only in the 50-<100 mSv category (RR: 2.746; 95% CI: 1.002, 7.521; P = 0.049) vs. 0 mSv. 3. The Poisson regression analyses among radiation workers using the time dependent radiation dose as a continuous variable showed an excess relative risk (ERR) for LHC at 100 mSv of 0.094 (95% CI: -0.037, 0.225; P = 0.158) and leukemia less chronic lymphoid leukemia, of 0.178 (95% CI: -0.085, 0.440; P = 0.440) vs. 0 mSv. The ERRs and their linear trend for all other types were not statistically significant.

15.
J Occup Environ Med ; 64(4): e224-e230, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35081587

RESUMO

OBJECTIVE: To examine the risk of diseases among industrial workers with low and fractionated radiation exposures. METHOD: The 372,047 US male shipyard radiation and non-radiation workers were followed for 54 years and compared with US men using standardized mortality ratio (SMR) method. RESULTS: SMRs for both radiation and non-radiation workers had lower risks of death from all causes (0.74; 95% confidence interval [CI] 0.74 to 0.75 and 0.77; 95% Cl 0.77 to 0.78, respectively) and from all cancers (0.92; 95% CI 0.91 to 0.93 and 0.90; 95% CI 0.89 to 0.91, respectively) compared with US men. Asbestos-related diseases including pleural cancers, mesothelioma, and asbestosis, but not lung cancers, were statistically higher in both radiation and non-radiation workers compared with the US men. CONCLUSION: US shipyard male radiation and non-radiation workers did not show any elevated mortality risks that might be associated with radiation exposure.


Assuntos
Amianto , Asbestose , Neoplasias Pulmonares , Mesotelioma , Doenças Profissionais , Exposição Ocupacional , Humanos , Masculino , Doenças Profissionais/etiologia , Exposição Ocupacional/efeitos adversos , Radiação Ionizante
17.
J Am Coll Radiol ; 18(12): 1596-1597, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34762831

Assuntos
Física Médica
19.
Radiol Cardiothorac Imaging ; 3(4): e210053, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34498007

RESUMO

PURPOSE: Conventional CT technology yields only modest accuracy of coronary artery stenosis assessment in severely calcified lesions. Reported herein are this study's initial observations on the potential of ultra-high-resolution CT (UHR-CT) for evaluating severely calcified coronary arterial lesions. MATERIALS AND METHODS: Fifteen patients 45 years of age or older, with history of coronary artery disease, referred for invasive coronary angiography, were prospectively enrolled. Patients underwent UHR-CT within 30 days prior to cardiac catheterization. Image noise levels and diagnostic confidence (level 1-5) using UHR-CT were compared with reconstructed images simulating conventional CT technology. Stenosis assessment for the major coronary arteries and the left main coronary artery with UHR-CT and invasive angiography were compared. Results from clinically driven coronary CT using conventional technology were considered for comparison when available. RESULTS: Mean patient age was 67 years (range, 53-79 years). Thirteen patients were men, nine had obesity. Radiation dose was 9.3 mSv owing to expanded x-ray exposure to accommodate research software application (70%-99% of R-R cycle). Overall image noise was considerably greater for UHR-CT (50.9 ± 7.8 [standard deviation]) versus conventional CT image reconstruction (19.5 ± 8.3, P < .01), yet diagnostic confidence scores for UHR-CT were high (4.3 ± 0.9). Average calcium score in patients without stents (n = 6) was 1205, and of 86 vessels evaluated, 22 had 70% or greater stenosis depicted with invasive angiography (26%). Stenosis comparison with invasive angiography yielded 86% (19 of 22) sensitivity and 88% (56 of 64) specificity (95% CI: 65%, 97%; and 77%, 95%, respectively). CONCLUSION: Initial observations suggest UHR-CT may be effective in overcoming the limitation of conventional CT for accurately evaluating coronary artery stenoses in severely calcified vessels.Keywords: CT-Angiography, Coronary Arteries, ArteriosclerosisClinical trial registration no. NCT04272060See also commentary by Shanbhag and Chen in this issue.© RSNA, 2021.

20.
Med Phys ; 48(8): 4375-4386, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34105167

RESUMO

PURPOSE: Chemical shift-encoded magnetic resonance imaging enables accurate quantification of liver fat content though estimation of proton density fat-fraction (PDFF). Computed tomography (CT) is capable of quantifying fat, based on decreased attenuation with increased fat concentration. Current quantitative fat phantoms do not accurately mimic the CT number of human liver. The purpose of this work was to develop and validate an optimized phantom that simultaneously mimics the MRI and CT signals of fatty liver. METHODS: An agar-based phantom containing 12 vials doped with iodinated contrast, and with a granular range of fat fractions was designed and constructed within a novel CT and MR compatible spherical housing design. A four-site, three-vendor validation study was performed. MRI (1.5T and 3T) and CT images were obtained using each vendor's PDFF and CT reconstruction, respectively. An ROI centered in each vial was placed to measure MRI-PDFF (%) and CT number (HU). Mixed-effects model, linear regression, and Bland-Altman analysis were used for statistical analysis. RESULTS: MRI-PDFF agreed closely with nominal PDFF values across both field strengths and all MRI vendors. A linear relationship (slope = -0.54 ± 0.01%/HU, intercept = 37.15 ± 0.03%) with an R2 of 0.999 was observed between MRI-PDFF and CT number, replicating established in vivo signal behavior. Excellent test-retest repeatability across vendors (MRI: mean = -0.04%, 95% limits of agreement = [-0.24%, 0.16%]; CT: mean = 0.16 HU, 95% limits of agreement = [-0.15HU, 0.47HU]) and good reproducibility using GE scanners (MRI: mean = -0.21%, 95% limits of agreement = [-1.47%, 1.06%]; CT: mean = -0.18HU, 95% limits of agreement = [-1.96HU, 1.6HU]) were demonstrated. CONCLUSIONS: The proposed fat phantom successfully mimicked quantitative liver signal for both MRI and CT. The proposed fat phantom in this study may facilitate broader application and harmonization of liver fat quantification techniques using MRI and CT across institutions, vendors and imaging platforms.


Assuntos
Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Fígado , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...