Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am Heart J ; 131(5): 899-906, 1996 May.
Artigo em Inglês | MEDLINE | ID: mdl-8615308

RESUMO

The purpose of this investigation was to compare the accuracy of intravascular ultrasound (IVUS) and electron-beam computed tomography (EBCT) in quantitating human atherosclerotic plaque and calcium. In experiment 1, 12 human atherosclerotic arterial segments were obtained at autopsy and imaged by using IVUS and EBCT. The plaque from each arterial segment was dissected and a volume measurement of the dissected plaque was obtained by water displacement. The plaque from each arterial segment was ashed at 700 degrees F, and the weight of the remaining ashes was used as an estimate of the calcium mass. In experiment II, 11 calcified arterial segments were obtained at autopsy and imaged by using IVUS at one site along the artery. A corresponding histologic cross section stained with Masson's trichrome was prepared. In experiment I, the mean plaque volume measured by water displacement was 165.3 +/- 118.4 microliters. The mean plaque volume calculated by IVUS was 166.1 +/- 114.4 microliters and correlated closely with that by water displacement (r = 0.98, p < 0.0001). The mean calcium mass measured by ashing was 19.4 +/- 15.8 mg. The mean calculated calcium mass by EBCT was 19.9 mg and correlated closely with that by ashing (r=0.98, p<0.001). The mean calculated calcium volume by IVUS was 18.6 +/- 11.2 microliters and correlated linearly with the calcium mass by ashing (r = 0.87, p < 0.0003). In experiment II, the mean cross-sectional area of the calcified matrix was 1.71 +/- 0.66 mm2 by histologic examination compared with 1.44 +/- 0.66 mm2 by IVUS. There was a good correlation between the calcified cross-sectional area by histologic examination and IVUS (r = 0.76, p < 0.007); however, IVUS may underestimate the amount of calcium present depending on the intralesional calcium morphologic characteristics. In conclusion, IVUS accurately quantitates atherosclerotic plaque volume as well as the cross-sectional area and volume of intralesional calcium, especially if the calcium is localized at the base of the plaque. IVUS underestimates the amount of calcium present because of signal drop-off when the calcium is too thick for the ultrasound to completely penetrate. In comparison, EBCT accurately quantitates calcium mass regardless of the intralesional calcium morphologic characteristics; however, EBCT does not accurately quantitate plaque volume and will miss noncalcified atherosclerotic lesions.


Assuntos
Arteriosclerose/patologia , Cálcio/análise , Artéria Ilíaca/química , Tomografia Computadorizada de Emissão , Ultrassonografia de Intervenção , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Humanos , Artéria Ilíaca/patologia , Técnicas In Vitro , Masculino , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Modelos Teóricos
2.
Am Heart J ; 130(5): 976-86, 1995 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-7484759

RESUMO

Intravascular ultrasound imaging was performed in vitro on six histologically normal and 104 minimally diseased arteries in patients aged 13 to 83 years. This study tested the hypothesis that normal coronary arteries produce a three-layer image that corresponds to the histologic layers of intima, media, and adventitia. The results showed a very good correlation between area of the echolucent ultrasound layer with the media and the inner echogenic layer with intimal area. In addition, a three-layer appearance was consistently seen when the internal elastic membrane was present with or without intimal hyperplasia. If the internal elastic membrane was absent, a three-layer appearance was still seen if the collagen content of the media was low. However, a two-layer appearance was observed when there was absence of the internal elastic membrane as well as a high collagen content of the media.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Ultrassonografia de Intervenção , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Doença das Coronárias/patologia , Vasos Coronários/patologia , Feminino , Humanos , Hiperplasia , Masculino , Pessoa de Meia-Idade , Túnica Íntima/diagnóstico por imagem , Túnica Íntima/patologia
3.
J Clin Ultrasound ; 23(8): 461-71, 1995 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-7499516

RESUMO

OBJECTIVES: The purpose of this study was to test the hypothesis that in occlusions of the superficial femoral artery, removal of atherosclerotic plaque would result in a higher long-term patency rate compared to balloon dilatation alone. A secondary hypothesis was that long term patency would be proportional to the amount of plaque removed. METHODS: A randomized controlled study of patients with occluded superficial femoral arteries was performed comparing balloon dilatation alone versus a 2.7 mm or a larger (4.0 mm or 4.7 mm) transcutaneous extraction catheter (TEC) atherectomy device followed by balloon dilatation. The effect of these devices on plaque area was assessed directly by intravascular ultrasound imaging. RESULTS: The mean occlusion length was 19.4 cm +/- 11.7 cm. The mean lumen area increased from 4.7 mm2 to 15.1 mm2, primarily due to balloon dilatation, but the mean atheroma area of 19.8 mm2 did not change with either size of TEC device. Although the initial procedure success rate was high (79%), the 6 month patency was only 45%. There was no difference in 6 month patency between the 3 groups. CONCLUSIONS: The data indicate that the TEC atherectomy devices do not remove a significant amount of atherosclerotic plaque in occluded superficial femoral arteries. The 6 month patency is no different with these atherectomy devices than with balloon dilatation alone. The larger (4.0 mm or 4.7 mm) TEC device does not remove any more tissue than the smaller (2.7 mm) device. The use of intravascular ultrasound to quantitate the effects of this atherectomy device provides important insights into the mechanism of action and lack of efficacy of the TEC atherectomy catheter.


Assuntos
Arteriosclerose/diagnóstico por imagem , Arteriosclerose/cirurgia , Aterectomia/métodos , Artéria Femoral/cirurgia , Ultrassonografia de Intervenção , Idoso , Cateterismo , Feminino , Artéria Femoral/diagnóstico por imagem , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Grau de Desobstrução Vascular
4.
Am Heart J ; 129(5): 841-51, 1995 May.
Artigo em Inglês | MEDLINE | ID: mdl-7732971

RESUMO

The rate of restenosis after directional coronary atherectomy (DCA) is higher than expected. To elucidate why, the current study used intravascular ultrasound (IVUS) imaging to investigate the mechanism of DCA. An in vitro validation study was performed to determine the accuracy of the measurement of plaque removal by IVUS. DCA was performed in eight human atherosclerotic artery segments. The volume of removed plaque was measured by water displacement and was compared with the volume calculated from IVUS images. A clinical study of DCA was performed in 32 lesions. IVUS was performed in 28 lesions after successful DCA. Measurements of lumen dimensions from digital angiograms before and after DCA were compared with observations of lumen and plaque size from the cross-sectional IVUS images. In the in vitro study, the mean plaque volume removed by DCA was 19.9 +/- 8.5 microliters. The calculated estimate of removed plaque volume by IVUS was 18.6 +/- 7.9 microliters and correlated closely with the volume by water displacement (r = 0.92). The calculated volume of plaque removed from histologic sections was 14.3 +/- 6.0 microliters and was linearly correlated with plaque volume by water displacement (r = 0.81). In the clinical study, the angiographic mean minimum lumen diameter increased from 1.0 +/- 0.4 to 2.7 +/- 0.5 mm and the percentage stenosis decreased from 70% to 19% (p < 0.0001). The IVUS images before and after DCA showed that the lumen DCA improved from 2.9 +/- 1.5 to 7.0 +/- 1.5 mm2 (p < 0.0001). In addition the vessel cross-sectional area (CSA) increased from 17.1 +/- 5.9 to 18.7 +/- 5.5 mm2. The atheroma CSA was reduced from 14.2 +/- 5.0 to 11.7 +/- 4.8 mm2. This combined effect of reduction in atheroma CSA and stretching of the outer vessel diameter resulted in an improvement in percentage plaque area stenosis from 83% +/- 7% to 61% +/- 9%. It is concluded that despite a successful angiographic appearance, DCA removed an average of 2.5 mm2 from the atheroma, which corresponds to only 18% of the atheroma CSA. The total lumen CSA increased 4.1 mm2; 61% of the new lumen was created by cutting and removal of plaque, whereas 39% of the new lumen was made by stretching the external wall of the artery. Despite an excellent angiographic result, IVUS imaging reveals that after DCA a significant amount of residual atheroma remains. As in balloon dilatation, a stretching effect is a significant component of DCA.


Assuntos
Aterectomia Coronária , Vasos Coronários/diagnóstico por imagem , Idoso , Angiografia Digital/estatística & dados numéricos , Arteriosclerose/diagnóstico por imagem , Arteriosclerose/patologia , Arteriosclerose/cirurgia , Aterectomia Coronária/instrumentação , Aterectomia Coronária/métodos , Aterectomia Coronária/estatística & dados numéricos , Angiografia Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Estudos de Avaliação como Assunto , Feminino , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/patologia , Artéria Ilíaca/cirurgia , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Recidiva , Ultrassonografia de Intervenção/métodos , Ultrassonografia de Intervenção/estatística & dados numéricos
5.
J Am Coll Cardiol ; 25(3): 633-9, 1995 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-7860907

RESUMO

OBJECTIVES: This study attempted to determine why there is a discrepancy between angiographic and intravascular ultrasound measurements after coronary balloon angioplasty. BACKGROUND: Previous studies have shown a poor correlation between angiographic and intravascular ultrasound measurements after percutaneous coronary balloon angioplasty. METHODS: After successful balloon angioplasty, 91 lesions in 84 patients were studied by intravascular ultrasound. Plaque morphology on intravascular ultrasound was classified as demonstrating a superficial injury if there was either no fracture or only a small tear that did not extend to the media versus a deep injury defined as the presence of a plaque fracture that reached the media. Measurements of minimal lumen diameter were compared between angiography and intravascular ultrasound. RESULTS: On ultrasound imaging, a superficial injury pattern was observed in 44 lesions, whereas a deep injury was seen in 47 lesions. There were no statistical differences at baseline in patient or lesion characteristics. In the superficial injury group there was a significant correlation between angiography and intravascular ultrasound for minimal lumen diameter (r = 0.67) and lumen cross-sectional area (r = 0.69). In the deep injury group there was a poor correlation for minimal lumen diameter (r = 0.05) and lumen cross-sectional area (r = 0.28). After balloon angioplasty, the angiographic appearance showed a normal contour in 34%, the presence of dissection in 38% or a hazy appearance in 23%. On ultrasound imaging after angioplasty, the superficial injury group comprised 65% of lesions with a normal angiographic appearance and 67% of lesions with a hazy appearance, whereas 77% of lesions with an angiographic diagnosis of dissection were in the deep injury group by ultrasound (p = 0.0005). CONCLUSIONS: These observations suggest that the discrepancies between angiographic and ultrasound measurements are due to differences in plaque morphology created by balloon dilation. Superficial injuries demonstrate similar results by angiography or ultrasound, whereas a deep injury to the plaque produces a difference in measurements between angiography and ultrasound. When angiography reveals a dissection, there is a high probability that intravascular ultrasound will demonstrate a plaque fracture extending to the media.


Assuntos
Angioplastia Coronária com Balão , Angiografia Coronária , Doença das Coronárias/patologia , Vasos Coronários/patologia , Idoso , Constrição Patológica , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/terapia , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia
6.
J Natl Med Assoc ; 84(4): 368-70, 1992 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-1507253

RESUMO

A case of a 36-year-old woman with a past history of uterine leiomyosarcoma and an intracerebral metastasis is reported. The patient presented with a 24-hour history of severe headache with coma, and the CT findings were consistent with a metastatic lesion. Pathological examination of the operative specimen showed features of a leiomyosarcoma. Uterine leiomyosarcoma is an uncommon tumor and metastasis to the brain is rare.


Assuntos
Neoplasias Encefálicas/secundário , Leiomiossarcoma/secundário , Lobo Parietal , Neoplasias Uterinas/patologia , Adulto , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Feminino , Humanos , Leiomiossarcoma/diagnóstico por imagem , Leiomiossarcoma/patologia , Tomografia Computadorizada por Raios X
8.
9.
Science ; 241(4870): 1198-200, 1988 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-17740783

RESUMO

The observed increase of superconducting transition temperature (T(c)) with the number of copper oxide planes continues in the four-[CuO(2)](-2) layer (single TI layer) oxide superconductor, which has been prepared with > 80% purity and was magnetically aligned for crystallographic identification. A master scaling curve is proposed, which ties together the T(c)'s of virtually all known Bi and Tl oxide superconductors, and shows that the Tl(Bi) layers play an essential role in the superconductivity. publication 350 of the Barnett Institute.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...