RESUMO
The goal was to assess the influence of thermal environment on thermal comfort of 15 multiparous lactating Holstein cows. Thermal comfort of the cows in the barn was assessed from the changes in their rectal temperature and respiratory frequency Air temperature and relative humidity were measured outside and inside the barn to characterize the macro-and microclimate. . There was no correlation between micro and macroclimate considering the physiological parameters. The thermal environment variables and physiological parameters were within ideal limits according literature, Therefore, we concluded that the facility may have been effective considering the thermal comfort needs of dairy cows.(AU)
O objetivo desta pesquisa foi avaliar a influência do ambiente térmico sobre o conforto térmico de 15 vacas leiteiras. O conforto térmico dos animais nas instalações foi avaliado mensurando a temperatura retal e frequência respiratória. A fim de caracterizar o micro e o macro clima foram coletados dados de temperatura e umidade relativa do ar do ambiente interno e externo. Não houve correlação entre o micro e o macro clima estudado em relação aos parâmetros fisiológicos avaliados. As variáveis ambientais e fisiológicas estavam dentro dos limites considerados ideias na literatura. Portanto, concluiu-se que as instalações foram eficientes em termos de conforto térmico para vacas em lactação. (AU)
Assuntos
Animais , Feminino , Bovinos , Microclima , Clima , Temperatura , UmidadeRESUMO
The goal was to assess the influence of thermal environment on thermal comfort of 15 multiparous lactating Holstein cows. Thermal comfort of the cows in the barn was assessed from the changes in their rectal temperature and respiratory frequency Air temperature and relative humidity were measured outside and inside the barn to characterize the macro-and microclimate. . There was no correlation between micro and macroclimate considering the physiological parameters. The thermal environment variables and physiological parameters were within ideal limits according literature, Therefore, we concluded that the facility may have been effective considering the thermal comfort needs of dairy cows.
O objetivo desta pesquisa foi avaliar a influência do ambiente térmico sobre o conforto térmico de 15 vacas leiteiras. O conforto térmico dos animais nas instalações foi avaliado mensurando a temperatura retal e frequência respiratória. A fim de caracterizar o micro e o macro clima foram coletados dados de temperatura e umidade relativa do ar do ambiente interno e externo. Não houve correlação entre o micro e o macro clima estudado em relação aos parâmetros fisiológicos avaliados. As variáveis ambientais e fisiológicas estavam dentro dos limites considerados ideias na literatura. Portanto, concluiu-se que as instalações foram eficientes em termos de conforto térmico para vacas em lactação.