Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Contemp Clin Dent ; 15(2): 138-142, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39206239

RESUMO

Ulcerated lesions have been observed in SARS-CoV-2 patients and their treatment is a challenge. We aim to report the treatment of oral lesions with low-level laser therapy (LLLT) in a patient with SARS-CoV-2. The patient diagnosed with COVID-19 was admitted to the intensive care unit, on mechanical ventilation, and on a nasogastric tube diet that persisted due to oral lesions. Painful ulcerated lesions, clinically diagnosed as viral ulcer, were found on the tongue, palate, labial commissure, and oropharynx during the oral evaluation. An antimicrobial photodynamic therapy with methylene blue and red laser (high energy) was performed, followed by treatment with LLLT with red laser. Significant clinical improvement of the lesions was observed after seven sessions of LLLT, with the oral diet being reestablished. Oral mucosal lesions in patients with COVID-19 are usually symptomatic and with onset after systemic symptoms. LLLT has been used in the management of these lesions, with promising results.

3.
BMC Oral Health ; 23(1): 322, 2023 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-37231426

RESUMO

BACKGROUND: Implant design and apical stability are principal parameters involved in achieving successful primary stability. Using polyurethane models to simulate post-extraction sockets, we investigated the effects of using differing blade designs on the primary stability of tapered implants and the impact of apical depth. METHOD: Six polyurethane blocks were used to simulate post-extraction pockets. One of the implants presented self-tapping blades (Group A), while the other (Group B) did not. Seventy-two implants were placed at 3 different depths (5 mm, 7 mm, and 9 mm), and a torque wrench was used to measure the stability of the implants. RESULTS: When evaluating the implants (placed at 5 mm, 7 mm, and 9 mm apical to the socket), we observed that the torque of the Group B implants was higher than that of Group A implants (P < 0.01). At the 9-mm depth, there was no difference between the groups (Drive GM 34.92 Ncm and Helix GM 32.33 Ncm) (P > 0.001), and considering the same implant groups, those placed at 7-mm and 9-mm depths presented higher torques (p < 0.01) than those placed at 5-mm (p > 0.01). CONCLUSION: Considering both groups, we concluded that an insertion depth of greater than 7 mm is needed for initial stability, and in situations involving reduced supportive bone tissue or low bone density, a non-self-tapping thread design improves implant stability.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Humanos , Poliuretanos , Alvéolo Dental/cirurgia , Assistência Odontológica , Torque , Planejamento de Prótese Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA