Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Open Heart ; 8(1)2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33958491

RESUMO

BACKGROUND: In patients with ST-segment elevation myocardial infarction (STEMI), it is unknown how patient delay modulates the beneficial effects of timely reperfusion. AIMS: To assess the prognostic significance of a contact-to-balloon time of less than 90 min on in-hospital mortality in different categories of symptom-onset-to-first-medical-contact (S2C) times. METHODS: A total of 20 005 consecutive patients from the Feedback Intervention and Treatment Times in ST-segment Elevation Myocardial Infarction (FITT-STEMI) programme treated with primary percutaneous coronary intervention (PCI) were included. RESULTS: There were 1554 deaths (7.8%) with a J-shaped relationship between mortality and S2C time. Mortality was 10.0% in patients presenting within 1 hour, and 4.9%, 6.0% and 7.3% in patient groups with longer S2C intervals of 1-2 hours, 2-6 hours and 6-24 hours, respectively. Patients with a short S2C interval of less than 1 hour (S2C<60 min) had the highest survival benefit from timely reperfusion with PCI within 90 min (OR 0.27, 95% CI 0.23 to 0.31, p<0.0001) as compared with the three groups with longer S2C intervals of 1 hour

Assuntos
Serviços Médicos de Emergência/métodos , Intervenção Coronária Percutânea/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Tempo para o Tratamento , Idoso , Feminino , Mortalidade Hospitalar/tendências , Humanos , Incidência , Masculino , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
2.
Indian Pacing Electrophysiol J ; 21(4): 209-218, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33866018

RESUMO

BACKGROUND: In patients with cardiac resynchronization therapy defibrillators (CRT-Ds), intracardiac impedance measured by dedicated CRT-D software may be used to monitor hemodynamic changes. We investigated the relationship of hemodynamic parameters assessed by intracardiac impedance and by echocardiography in a controlled clinical setting. METHODS: The study enrolled 68 patients (mean age, 66 ± 9 years; 74% males) at 12 investigational sites. The patients had an indication for CRT-D implantation, New York Heart Association class II/III symptoms, left ventricular ejection fraction 15%-35%, and a QRS duration ≥150 ms. Two months after a CRT-D implantation, hemodynamic changes were provoked by overdrive pacing. Intracardiac impedance was recorded at rest and at four pacing rates ranging from 10 to 40 beats/min above the resting rate. In parallel, echocardiography measurements were performed. We hypothesized that a mean intra-individual correlation coefficient (rmean) between stroke impedance (difference between end-systolic and end-diastolic intracardiac impedance) measured by CRT-D and the aortic velocity time integral (i.e., stroke volume) determined by echocardiography would be significantly larger than 0.65. RESULTS: The hypothesis was evaluated in 40 patients with complete data sets. The rmean was 0.797, with a lower confidence interval bound of 0.709. The study hypothesis was met (p = 0.007). A stepwise reduction of stroke impedance and stroke volume was observed with increasing heart rate. CONCLUSIONS: Intracardiac impedance measured by implanted CRT-Ds correlated well with the aortic velocity time integral (stroke volume) determined by echocardiography. The impedance measurements bear potential and are readily available technically, not requiring implantation of additional material beyond standard CRT-D system.

3.
Artigo em Inglês | MEDLINE | ID: mdl-33609099

RESUMO

AIMS: Current European Society of Cardiology guidelines state that repetitive monitoring and feedback should be implemented for ST-elevation myocardial infarction (STEMI) treatment, but no evidence is available supporting this recommendation. We aimed to analyze the long-term effects of a formalized data assessment and systematic feedback on performance and mortality within the prospective, multicenter Feedback Intervention and Treatment Times in STEMI (FITT-STEMI) study. METHODS: Regular interactive feedback sessions with local STEMI management teams were performed at six participating German percutaneous coronary intervention (PCI) centers over a 10-year period starting from October 2007. RESULTS: From the first to the 10th year of study participation, all predefined key-quality indicators for performance measurement used for feedback improved significantly in all 4926 consecutive PCI-treated patients - namely, the percentages of patients with pre-hospital electrocardiogram (ECG) recordings (83.3% vs 97.1%, p < 0.0001) and ECG recordings within 10 minutes after first medical contact (41.7% vs 63.8%, p < 0.0001), pre-announcement by telephone (77.0% vs 85.4%, p = 0.0007), direct transfer to the catheterization laboratory bypassing the emergency department (29.4% vs 64.2%, p < 0.0001), and contact-to-balloon times of less than 90 minutes (37.2% vs 53.7%, p < 0.0001). Moreover, this feedback-related continuous improvement of key-quality indicators was linked to a significant reduction in in-hospital mortality from 10.8% to 6.8% (p = 0.0244). Logistic regression models confirmed an independent beneficial effect of duration of study participation on hospital mortality (odds ratio = 0.986, 95% confidence interval = 0.976-0.996, p = 0.0087). In contrast, data from a nationwide PCI registry showed a continuous increase in in-hospital mortality in all PCI-treated STEMI patients in Germany from 2008 to 2015 (n = 398,027; 6.7% to 9.2%, p < 0.0001). CONCLUSIONS: Our results indicate that systematic data assessment and regular feedback is a feasible long-term strategy and may be linked to improved performance and a reduction in mortality in STEMI management.

4.
Clin Res Cardiol ; 109(7): 911-917, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31823040

RESUMO

BACKGROUND: In patients with high risk for sudden cardiac death the implantation of a defibrillator is an established treatment. However the benefits and risks for patients in accordance to the number of the leads are not clear. Even in the current guidelines a recommendation to this question is missing. We analyzed advantage and disadvantages of single-chamber implantable cardioverter defibrillators (VVI-ICD) versus dual-chamber implantable cardioverter defibrillators (DDD-ICD) in the prospective German Device Registry. METHODS: The data of 2240 patients who underwent ICD implantation in 45 German Centers between January 2007 and March 2011 were included in a prospective device registry (VVI: n = 1629, male = 1358, EF = 34% ± 13%; DDD: n = 611, male = 491, EF = 35% ± 14%). RESULTS: The in-hospital complications were significantly higher in the DDD-ICD group with higher revision/device complication rates (3.0% vs. 1.2%; p = 0.003) but also higher mortality rate (1.0% vs. 0.1%; p < 0.001). Regarding the adjusted data at 1-year follow-up DDD-ICD caused more device revisions, but no difference in rehospitalization and mortality. CONCLUSION: It is still unclear whether DDD-ICD may be beneficial for patients with preserved sinus and atrioventricular nodal function. Our data show that the decision of the operator to choose a DDD-ICD in these patients must be taken very carefully. By choosing a DDD-ICD the patient is exposed to a significantly higher periprocedural complication rate and higher in-hospital mortality. In absence of relevant bradycardias implantation of a DDD-ICD is not justified.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/complicações , Idoso , Arritmias Cardíacas/complicações , Arritmias Cardíacas/mortalidade , Estudos de Coortes , Desenho de Equipamento , Feminino , Alemanha , Insuficiência Cardíaca/mortalidade , Mortalidade Hospitalar , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros
5.
J Electrocardiol ; 53: 100-108, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30739055

RESUMO

AIMS: Remote monitoring by implantable devices substantially improves management of heart failure (HF) patients by providing diagnostic day-to-day data. The use of thoracic impedance (TI) as a surrogate measure of fluid accumulation is still strongly debated. The multicenter HomeCARE-II study evaluated clinically apparent HF events in the context of remote device diagnostics, focusing on the controversial role of TI. METHODS AND RESULTS: We followed 497 patients (66.6 ±â€¯10.1 years, 77% male, QRS 139.8 ±â€¯36.0 ms, ejection fraction 26.8 ±â€¯7.0%) implanted with a CRT-D (67%) or an ICD (33%) for 21.4 ±â€¯8.1 months. An independent event committee confirmed 171 HF events of which 82 were used to develop a TI-based algorithm for the prediction of imminent cardiac decompensation. Highly inter-individual variations in patterns of TI trends were observed. The algorithm resulted in a sensitivity of 41.5% (50.0%) with 0.95 (1.34) false alerts per patient year, and a positive predictive value of 7.9% overall and 27.9% in the HF event group of patients. Averaged ratio statistics showed a significant pre-hospital decrease and a highly significant in-hospital increase in TI after intensified diuresis. Recurrent decompensations turned out to be preceded by a significantly stronger decrease of TI compared to first events with a higher chance for detection (63.6% sensitivity, p < 0.05). CONCLUSIONS: Overall performance in predicting imminent decompensation by monitoring TI alone is limited due to its high inter-patient variability. TI stand-alone applications should be redirected towards a target population with more advanced symptoms where post-hospital observation aimed to maintain the patient's discharge status might be the most valuable approach. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier NCT00711360 (HomeCARE-II) and NCT01221649 (J-HomeCARE-II).


Assuntos
Cardiografia de Impedância/instrumentação , Insuficiência Cardíaca/fisiopatologia , Idoso , Algoritmos , Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Impedância Elétrica , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Humanos , Masculino , Estudos Prospectivos , Sensibilidade e Especificidade , Volume Sistólico
6.
Eur Heart J ; 39(13): 1065-1074, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29452351

RESUMO

Aims: The aim of this study was to investigate the effect of contact-to-balloon time on mortality in ST-segment elevation myocardial infarction (STEMI) patients with and without haemodynamic instability. Methods and results: Using data from the prospective, multicentre Feedback Intervention and Treatment Times in ST-Elevation Myocardial Infarction (FITT-STEMI) trial, we assessed the prognostic relevance of first medical contact-to-balloon time in n = 12 675 STEMI patients who used emergency medical service transportation and were treated with primary percutaneous coronary intervention (PCI). Patients were stratified by cardiogenic shock (CS) and out-of-hospital cardiac arrest (OHCA). For patients treated within 60 to 180 min from the first medical contact, we found a nearly linear relationship between contact-to-balloon times and mortality in all four STEMI groups. In CS patients with no OHCA, every 10-min treatment delay resulted in 3.31 additional deaths in 100 PCI-treated patients. This treatment delay-related increase in mortality was significantly higher as compared to the two groups of OHCA patients with shock (2.09) and without shock (1.34), as well as to haemodynamically stable patients (0.34, P < 0.0001). Conclusions: In patients with CS, the time elapsing from the first medical contact to primary PCI is a strong predictor of an adverse outcome. This patient group benefitted most from immediate PCI treatment, hence special efforts to shorten contact-to-balloon time should be applied in particular to these high-risk STEMI patients. Clinical Trial Registration: NCT00794001.


Assuntos
Angioplastia Coronária com Balão , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Tempo para o Tratamento , Idoso , Idoso de 80 Anos ou mais , Serviços Médicos de Emergência , Feminino , Alemanha , Hemodinâmica , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Parada Cardíaca Extra-Hospitalar/mortalidade , Parada Cardíaca Extra-Hospitalar/fisiopatologia , Parada Cardíaca Extra-Hospitalar/cirurgia , Estudos Prospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Choque Cardiogênico/fisiopatologia , Choque Cardiogênico/cirurgia
7.
Am J Cardiol ; 118(2): 264-74, 2016 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-27265676

RESUMO

Patients with genetic cardiomyopathy that involves myocardial hypertrophy often develop clinically relevant arrhythmias that increase the risk of sudden death. Consequently, guidelines for medical device therapy were established for hypertrophic cardiomyopathy, but not for conditions with only anecdotal evidence of arrhythmias, like Fabry cardiomyopathy. Patients with Fabry cardiomyopathy progressively develop myocardial fibrosis, and sudden cardiac death occurs regularly. Because 24-hour Holter electrocardiograms (ECGs) might not detect clinically important arrhythmias, we tested an implanted loop recorder for continuous heart rhythm surveillance and determined its impact on therapy. This prospective study included 16 patients (12 men) with advanced Fabry cardiomyopathy, relevant hypertrophy, and replacement fibrosis in "loco typico." No patients previously exhibited clinically relevant arrhythmias on Holter ECGs. Patients received an implantable loop recorder and were prospectively followed with telemedicine for a median of 1.2 years (range 0.3 to 2.0 years). The primary end point was a clinically meaningful event, which required a therapy change, captured with the loop recorder. Patients submitted data regularly (14 ± 11 times per month). During follow-up, 21 events were detected (including 4 asystole, i.e., ECG pauses ≥3 seconds) and 7 bradycardia events; 5 episodes of intermittent atrial fibrillation (>3 minutes) and 5 episodes of ventricular tachycardia (3 sustained and 2 nonsustained). Subsequently, as defined in the primary end point, 15 events leaded to a change of therapy. These patients required therapy with a pacemaker or cardioverter-defibrillator implantation and/or anticoagulation therapy for atrial fibrillation. In conclusion, clinically relevant arrhythmias that require further device and/or medical therapy are often missed with Holter ECGs in patients with advanced stage Fabry cardiomyopathy, but they can be detected by telemonitoring with an implantable loop recorder.


Assuntos
Arritmias Cardíacas/diagnóstico , Doença de Fabry/terapia , Adulto , Idoso , Anticoagulantes/uso terapêutico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/etiologia , Bradicardia/diagnóstico , Bradicardia/etiologia , Bradicardia/terapia , Estimulação Cardíaca Artificial , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Erros de Diagnóstico , Eletrocardiografia , Eletrocardiografia Ambulatorial , Doença de Fabry/complicações , Feminino , Parada Cardíaca/diagnóstico , Parada Cardíaca/etiologia , Parada Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Estudos Prospectivos , Próteses e Implantes , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Telemedicina
10.
J Mol Cell Cardiol ; 64: 69-78, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23982034

RESUMO

Voltage-gated sodium channels are responsible for the rising phase of the action potential in cardiac muscle. Previously, both TTX-sensitive neuronal sodium channels (NaV1.1, NaV1.2, NaV1.3, NaV1.4 and NaV1.6) and the TTX-resistant cardiac sodium channel (NaV1.5) have been detected in cardiac myocytes, but relative levels of protein expression of the isoforms were not determined. Using a quantitative approach, we analyzed z-series of confocal microscopy images from individual mouse myocytes stained with either anti-NaV1.1, anti-NaV1.2, anti-NaV1.3, anti-NaV1.4, anti-NaV1.5, or anti-NaV1.6 antibodies and calculated the relative intensity of staining for these sodium channel isoforms. Our results indicate that the TTX-sensitive channels represented approximately 23% of the total channels, whereas the TTX-resistant NaV1.5 channel represented 77% of the total channel staining in mouse ventricular myocytes. These ratios are consistent with previous electrophysiological studies in mouse ventricular myocytes. NaV1.5 was located at the cell surface, with high density at the intercalated disc, but was absent from the transverse (t)-tubular system, suggesting that these channels support surface conduction and inter-myocyte transmission. Low-level cell surface staining of NaV1.4 and NaV1.6 channels suggest a minor role in surface excitation and conduction. Conversely, NaV1.1 and NaV1.3 channels are localized to the t-tubules and are likely to support t-tubular transmission of the action potential to the myocyte interior. This quantitative immunocytochemical approach for assessing sodium channel density and localization provides a more precise view of the relative importance and possible roles of these individual sodium channel protein isoforms in mouse ventricular myocytes and may be applicable to other species and cardiac tissue types.


Assuntos
Ventrículos do Coração/metabolismo , Miócitos Cardíacos/metabolismo , Canais de Sódio/metabolismo , Animais , Membrana Celular/metabolismo , Imuno-Histoquímica/métodos , Imuno-Histoquímica/normas , Espaço Intracelular/metabolismo , Masculino , Camundongos , Canal de Sódio Disparado por Voltagem NAV1.5/metabolismo , Isoformas de Proteínas , Transporte Proteico , Canais de Sódio/classificação
11.
J Mol Cell Cardiol ; 61: 133-141, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23702286

RESUMO

Voltage-gated sodium channels composed of a pore-forming α subunit and auxiliary ß subunits are responsible for the upstroke of the action potential in cardiac muscle. However, their localization and expression patterns in human myocardium have not yet been clearly defined. We used immunohistochemical methods to define the level of expression and the subcellular localization of sodium channel α and ß subunits in human atrial myocytes. Nav1.2 channels are located in highest density at intercalated disks where ß1 and ß3 subunits are also expressed. Nav1.4 and the predominant Nav1.5 channels are located in a striated pattern on the cell surface at the z-lines together with ß2 subunits. Nav1.1, Nav1.3, and Nav1.6 channels are located in scattered puncta on the cell surface in a pattern similar to ß3 and ß4 subunits. Nav1.5 comprised approximately 88% of the total sodium channel staining, as assessed by quantitative immunohistochemistry. Functional studies using whole cell patch-clamp recording and measurements of contractility in human atrial cells and tissue showed that TTX-sensitive (non-Nav1.5) α subunit isoforms account for up to 27% of total sodium current in human atrium and are required for maximal contractility. Overall, our results show that multiple sodium channel α and ß subunits are differentially localized in subcellular compartments in human atrial myocytes, suggesting that they play distinct roles in initiation and conduction of the action potential and in excitation-contraction coupling. TTX-sensitive sodium channel isoforms, even though expressed at low levels relative to TTX-sensitive Nav1.5, contribute substantially to total cardiac sodium current and are required for normal contractility. This article is part of a Special Issue entitled "Na(+) Regulation in Cardiac Myocytes".


Assuntos
Átrios do Coração/metabolismo , Miocárdio/metabolismo , Canais de Sódio Disparados por Voltagem/metabolismo , Conexina 43/metabolismo , Átrios do Coração/patologia , Humanos , Técnicas In Vitro , Concentração Inibidora 50 , Contração Miocárdica , Miócitos Cardíacos/fisiologia , Especificidade de Órgãos , Subunidades Proteicas/metabolismo , Bloqueadores dos Canais de Sódio/farmacologia , Tetrodotoxina/farmacologia
12.
JACC Cardiovasc Interv ; 5(8): 848-57, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22917457

RESUMO

OBJECTIVES: This study sought to evaluate the effect of systematic data analysis and standardized feedback on treatment times and outcome in a prospective multicenter trial. BACKGROUND: Formalized data feedback may reduce treatment times in ST-segment elevation myocardial infarction (STEMI). METHODS: Over a 15-month period, 1,183 patients presenting with STEMI were enrolled. Six primary percutaneous coronary intervention hospitals in Germany and 29 associated nonpercutaneous coronary intervention hospitals participated. Data from patient contact to balloon inflation were collected and analyzed. Pre-defined quality indicators, including the percentage of patients with pre-announced STEMI, direct handoff in the catheterization laboratory, contact-to-balloon time <90 min, door-to-balloon time <60 min, and door-to-balloon time <30 min were discussed with staff on a quarterly basis. RESULTS: Median door-to-balloon time decreased from 71 to 58 min and contact-to-balloon time from 129 to 103 min between the first and the fifth quarter (p < 0.05 for both). Contributing were shorter stays in the emergency department, more direct handoffs from ambulances to the catheterization laboratory (from 22% to 38%, p < 0.05), and a slight increase in the number of patients transported directly to the percutaneous coronary intervention facility (primary transport). One-year mortality was reduced in the total group of patients and in the subgroup of patients with primary transport (p < 0.05). The sharpest fall in mortality was observed in patients with primary transport and TIMI (Thrombolysis In Myocardial Infarction) risk score ≥ 3 (n = 521) with a decrease in 30-day mortality from 23.1% to 13.3% (p < 0.05) and in 1-year mortality from 25.6% to 16.7% (p < 0.05). CONCLUSIONS: Formalized data feedback is associated with a reduction in treatment times for STEMI and with an improved prognosis, which is most pronounced in high-risk patients. (Feedback Intervention and Treatment Times in ST-Elevation Myocardial Infarction [FITT-STEMI]; NCT00794001).


Assuntos
Infarto do Miocárdio/terapia , Tempo para o Tratamento/estatística & dados numéricos , Retroalimentação , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Registros , Estatística como Assunto
13.
Am Heart J ; 163(6): 938-45, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22709745

RESUMO

BACKGROUND: In current guidelines, intraaortic balloon pumping (IABP) is considered a class 1 indication in cardiogenic shock complicating acute myocardial infarction. However, evidence is mainly based on retrospective or prospective registries with a lack of randomized clinical trials. Therefore, IABP is currently only used in 20% to 40% of cardiogenic shock cases. The hypothesis of this trial is that IABP in addition to early revascularization by either percutaneous coronary intervention or coronary artery bypass grafting will improve clinical outcome of patients in cardiogenic shock. STUDY DESIGN: The IABP-SHOCK II study is a 600-patient, prospective, multicenter, randomized, open-label, controlled trial. The study is designed to compare the efficacy and safety of IABP versus optimal medical therapy on the background of early revascularization by either percutaneous coronary intervention or coronary artery bypass grafting. Patients will be randomized in a 1:1 fashion to 1 of the 2 treatments. The primary efficacy end point of IABP-SHOCK II is 30-day all-cause mortality. Secondary outcome measures, such as hemodynamic, laboratory, and clinical parameters, will serve as surrogate end points for prognosis. Furthermore, an intermediate and long-term follow-up at 6 and 12 months will be performed. Safety will be assessed, by the GUSTO bleeding definition, peripheral ischemic complications, sepsis, and stroke. CONCLUSIONS: The IABP-SHOCK II trial addresses important questions regarding the efficacy and safety of IABP in addition to early revascularization in patients with cardiogenic shock complicating myocardial infarction.


Assuntos
Balão Intra-Aórtico , Infarto do Miocárdio/complicações , Choque Cardiogênico/terapia , Ponte de Artéria Coronária , Humanos , Prognóstico , Estudos Prospectivos , Projetos de Pesquisa , Choque Cardiogênico/etiologia , Tiazóis
14.
J Clin Invest ; 122(3): 1119-30, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22354168

RESUMO

Cardiac pacemaker cells create rhythmic pulses that control heart rate; pacemaker dysfunction is a prevalent disorder in the elderly, but little is known about the underlying molecular causes. Popeye domain containing (Popdc) genes encode membrane proteins with high expression levels in cardiac myocytes and specifically in the cardiac pacemaking and conduction system. Here, we report the phenotypic analysis of mice deficient in Popdc1 or Popdc2. ECG analysis revealed severe sinus node dysfunction when freely roaming mutant animals were subjected to physical or mental stress. In both mutants, bradyarrhythmia developed in an age-dependent manner. Furthermore, we found that the conserved Popeye domain functioned as a high-affinity cAMP-binding site. Popdc proteins interacted with the potassium channel TREK-1, which led to increased cell surface expression and enhanced current density, both of which were negatively modulated by cAMP. These data indicate that Popdc proteins have an important regulatory function in heart rate dynamics that is mediated, at least in part, through cAMP binding. Mice with mutant Popdc1 and Popdc2 alleles are therefore useful models for the dissection of the mechanisms causing pacemaker dysfunction and could aid in the development of strategies for therapeutic intervention.


Assuntos
Moléculas de Adesão Celular/metabolismo , Proteínas Musculares/metabolismo , Canais de Potássio de Domínios Poros em Tandem/metabolismo , Animais , Relógios Biológicos , Bradicardia/genética , Eletrocardiografia/métodos , Eletrofisiologia/métodos , Frequência Cardíaca , Proteínas de Membrana/metabolismo , Camundongos , Camundongos Transgênicos , Fenótipo , Estrutura Terciária de Proteína , Telemetria/métodos , Fatores de Tempo
15.
Europace ; 14(2): 230-7, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21933802

RESUMO

AIMS: Uncertainty exists over the importance of device-detected short-duration atrial arrhythmias. Continuous atrial diagnostics, through home monitoring (HM) technology (BIOTRONIK, Berlin, Germany), provides a unique opportunity to assess frequency and quantity of atrial fibrillation (AF) episodes defined as atrial high-rate events (AHRE). METHODS AND RESULTS: Prospective data from 560 heart failure (HF) patients (age 67 ± 10 years, median ejection fraction 27%) patients with a cardiac resynchronization therapy (CRT) device capable of HM from two multi-centre studies were analysed. Atrial high-rate events burden was defined as the duration of mode switch in a 24-h period with atrial rates of >180 beats for at least 1% or total of 14 min per day. The primary endpoint was incidence of a thromboembolic (TE) event. Secondary endpoints were cardiovascular death, hospitalization because of AF, or worsening HF. Over a median 370-day follow-up AHRE occurred in 40% of patients with 11 (2%) patients developing TE complications and mortality rate of 4.3% (24 deaths, 16 with cardiovascular aetiology). Compared with patients without detected AHRE, patients with detected AHRE>3.8 h over a day were nine times more likely to develop TE complications (P= 0.006). The majority of patients (73%) did not show a temporal association with the detected atrial episode and their adverse event, with a mean interval of 46.7 ± 71.9 days (range 0-194) before the TE complication. CONCLUSION: In a high-risk cohort of HF patients, device-detected atrial arrhythmias are associated with an increased incidence of TE events. A cut-off point of 3.8 h over 24 h was associated with significant increase in the event rate. Routine assessment of AHRE should be considered with other data when assessing stroke risk and considering anti-coagulation initiation and should also prompt the optimization of cardioprotective HF therapy in CRT patients.


Assuntos
Fibrilação Atrial/dietoterapia , Fibrilação Atrial/mortalidade , Eletrocardiografia Ambulatorial/estatística & dados numéricos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/prevenção & controle , Serviços de Assistência Domiciliar/estatística & dados numéricos , Idoso , Fibrilação Atrial/prevenção & controle , Terapia de Ressincronização Cardíaca , Estudos de Coortes , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Internacionalidade , Masculino , Prevalência , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade , Análise de Sobrevida , Taxa de Sobrevida
17.
Cell Physiol Biochem ; 28(1): 77-86, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21865850

RESUMO

BACKGROUND/AIMS: The aim of the study was to characterize the whole cell current of the two-pore domain potassium channel TASK-1 (K2P3) in mouse ventricular cardiomyocytes (I(TASK-1)) and to analyze the cardiac phenotype of the TASK-1(-/-) mice. METHODS AND RESULTS: We have quantified the ventricular I(TASK-1) current using the blocker A293 and TASK-1(-/-) mice. Surface electrocardiogram recordings of TASK-1(-/-) mice showed a prolonged QTc interval and a broadened QRS complex. The differences in electrocardiograms between wild type and TASK-1(-/-) mice disappeared during sympathetic stimulation of the animals. Quantitative RT-PCR, patch clamp recordings and measurements of hemodynamic performance of TASK-1(-/-) mice revealed no major compensatory changes in ion channel transcription. Action potential recordings of TASK-1(-/-) mouse cardiomyocytes indicated that I(TASK-1) modulates action potential duration. Our in vivo electrophysiological studies showed that isoflurane, which activates TASK-1, slowed heart rate and atrioventricular conduction of wild-type but not of TASK-1(-/-) mice. CONCLUSION: The results of an invasive electrophysiological catheter protocol in combination with the observed QRS time prolongation in the surface electrocardiogram point towards a regulatory role of TASK-1 in the cardiac conduction system.


Assuntos
Síndrome do QT Longo/etiologia , Proteínas do Tecido Nervoso/genética , Proteínas do Tecido Nervoso/metabolismo , Canais de Potássio de Domínios Poros em Tandem/genética , Canais de Potássio de Domínios Poros em Tandem/metabolismo , Sulfonamidas/farmacologia , ortoaminobenzoatos/farmacologia , Potenciais de Ação/fisiologia , Anestésicos Inalatórios/farmacologia , Animais , Fenômenos Eletrofisiológicos/fisiologia , Frequência Cardíaca/efeitos dos fármacos , Hemodinâmica/fisiologia , Isoflurano/farmacologia , Metoxamina/farmacologia , Camundongos , Camundongos Knockout , Miócitos Cardíacos/efeitos dos fármacos , Miócitos Cardíacos/fisiologia , Proteínas do Tecido Nervoso/deficiência , Canais de Potássio de Domínios Poros em Tandem/deficiência
18.
Am J Cardiol ; 106(2): 216-20, 2010 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-20599006

RESUMO

The high incidence of sudden cardiac death in heart failure (HF) reflects electrophysiologic changes in response to myocardial failure. We previously showed that short-term variability of QT intervals (STV(QT)) identifies latent repolarization disorders in patients with drug-induced or congenital long QT syndrome. This study sought to determine (1) if STV(QT) is increased in patients with dilated cardiomyopathy (DC) and moderate congestive HF and (2) if increased STV(QT) is associated with ventricular arrhythmia in patients with HF. Sixty patients (53 +/- 12 years of age, 14 women) with DC and moderate HF (New York Heart Association classes II to III) were compared to matched controls. Twenty patients had implantable cardiac defibrillators secondary to a history of ventricular tachycardia (VT). Two cardiologists blinded to diagnosis manually measured QT intervals. Beat-to-beat variability of repolarization was determined from Poincaré plots of 30 consecutive QT intervals as was STV(QT). QTc intervals were comparable in patients and controls (419 +/- 36 vs 415 +/- 32 ms, respectively, p >0.05), whereas STV(QT) was significantly higher in patients with HF (7.8 +/- 3 vs 4.1 +/- 2 ms, respectively, p <0.05). STV(QT) was more increased in patients with a history of VT compared to those without VT (10.1 +/- 2 vs 6.6 +/- 2 ms, respectively, p <0.05). Increased STV(QT) and decreased ejection fraction were associated with a history of VT; however, STV(QT) was the strongest indicator. In conclusion, the present study demonstrates for the first time that STV(QT) is increased in patients with DC with HF. Patients with DC and HF and implantable cardiac defibrillators for secondary prevention had the highest STV(QT). Thus, increased STV(QT) in the context of moderate HF may reflect a latent repolarization disorder and increased susceptibility to sudden death in patients with DC, which is not identified by a prolonged QT interval.


Assuntos
Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Insuficiência Cardíaca/complicações , Adulto , Idoso , Eletrofisiologia Cardíaca , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Índice de Gravidade de Doença
19.
Am J Med ; 123(7): 652-7, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20609688

RESUMO

BACKGROUND: The differential diagnosis of hyponatremia is often challenging because of its association with multiple underlying pathophysiological mechanisms, diseases, and treatment options. Several algorithms are available to guide the diagnostic approach to hyponatremia, but their diagnostic and clinical utility has never been evaluated. We aimed to assess in detail the diagnostic utility as well as the limitations of the existing approaches to hyponatremia. METHODS: Each of the 121 consecutive subjects presenting with hyponatremia (serum sodium <130 mmoL/L) underwent 3 different and independent diagnostic and therapeutic approaches: inexperienced doctor applying an established Algorithm, intensive care senior physicians acting as Senior Physician, and senior endocrinologist serving as Reference Standard. RESULTS: The overall diagnostic agreement between Algorithm and Reference Standard was 71% (respective Cohen's kappa and delta values were 0.64 and 0.70), the overall diagnostic agreement between Senior Physician and Reference Standard was 32% (0.20 and 0.19, respectively). Regarding the therapeutic consequences, the diagnostic accuracy of the Algorithm was 86% (0.70 and 0.72, respectively) and of the Senior Physician was 48% (0.01 and 0.04, respectively). In retrospect, by disregarding the patient's extracellular fluid volume and assessing the effective arterial blood volume by determination of the fractional urate excretion, the Algorithm improved its diagnostic accuracy to 95%. CONCLUSION: Although the Algorithm performed reasonably well, several shortcomings became apparent, rendering it difficult to apply the Algorithm without reservation. Whether some modifications may enhance its diagnostic accuracy and simplify the management of hyponatremia needs to be determined.


Assuntos
Hiponatremia/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Diagnóstico Diferencial , Feminino , Humanos , Hiponatremia/terapia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Padrões de Referência , Sódio/sangue , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...