Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-27601429

RESUMO

BACKGROUND: The risk for stroke after transcatheter aortic valve replacement (TAVR) is an important concern. Identification of predictors for stroke is likely to be a critical factor aiding patient selection and management as TAVR use becomes widespread. METHODS AND RESULTS: Patients enrolled in the CoreValve US Extreme Risk and High Risk Pivotal Trials or Continued Access Study treated with the self-expanding CoreValve bioprosthesis were included in this analysis. The 1-year stroke rate after TAVR was 8.4%. Analysis of the stroke hazard rate identified an early phase (0-10 days; 4.1% of strokes) and a late phase (11-365 days; 4.3% of strokes). Baseline predictors of early stroke included National Institutes of Health stroke scale score >0, prior stroke, prior transient ischemic attack, peripheral vascular disease, absence of prior coronary artery bypass surgery, angina, low body mass index (<21 kg/m(2)), and falls within the past 6 months. Significant procedural predictors were total time in the catheterization laboratory or operating room, delivery catheter in the body time, rapid pacing used during valvuloplasty, and repositioning of the prosthesis. Predictors of stroke between 11 and 365 days were small body surface area, severe aortic calcification, and falls within the past 6 months. There were no significant imaging predictors of early or late stroke. CONCLUSIONS: Predictors of early stroke after TAVR included clinical and procedural factors; predictors of later stroke were limited to patient but not anatomic characteristics. These findings indicate that further refinement of imaging to identify anatomic factors predisposing to embolization may help improve stroke prediction in patients undergoing TAVR. CLINICAL TRIAL REGISTRATIONS: URL: http://www.clinicaltrials.gov. Unique identifiers: NCT01240902, NCT01531374.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Calcinose/cirurgia , Embolia Intracraniana/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Bioprótese , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Calcinose/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Ensaios Clínicos como Assunto , Feminino , Próteses Valvulares Cardíacas , Humanos , Incidência , Embolia Intracraniana/diagnóstico , Embolia Intracraniana/mortalidade , Estimativa de Kaplan-Meier , Masculino , Modelos de Riscos Proporcionais , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...