Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
RSC Adv ; 14(25): 18103-18108, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38847004

RESUMO

We introduce an innovative solution to reduce plastic dependence in flexible electronics: a biodegradable, water-resistant, and flexible cellulose-based substrate for crafting electrochemical printed platforms. This sustainable material based on ethyl cellulose (EC) serves as an eco-friendly alternative to PET in screen printing, boasting superior water resistance compared to other biodegradable options. Our study evaluates the performance of carbon-based screen-printed electrodes (SPEs) fabricated on conventional PET, recycled PET (r-PET), and (EC)-based materials. Electrochemical characterization reveals that EC-SPEs exhibit comparable analytical performance to both P-SPEs and rP-SPEs, as evidenced by similar limits of detection (LOD), limits of quantification (LOQ), and reproducibility values for all the analytes tested (ferro-ferricyanide, hexaammineruthenium chloride, uric acid, and hydroquinone). This finding underscores the potential of our cellulose-based substrate to match the performance of conventional PET-based electrodes. Moreover, the scalability and low-energy requirements of our fabrication process highlight the potential of this material to revolutionize eco-conscious manufacturing. By offering a sustainable alternative without compromising performance, our cellulose-based substrate paves the way for greener practices in flexible electronics production.

2.
Adv Sci (Weinh) ; 10(24): e2301925, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37357140

RESUMO

Today, the key methodology to study in vitro or in vivo electrical activity in a population of electrogenic cells, under physiological or pathological conditions, is by using microelectrode array (MEA). While significant efforts have been devoted to develop nanostructured MEAs for improving the electrophysiological investigation in neurons and cardiomyocytes, data on the recording of the electrical activity from neuroendocrine cells with MEA technology are scarce owing to their weaker electrical signals. Disordered silicon nanowires (SiNWs) for developing a MEA that, combined with a customized acquisition board, successfully capture the electrical signals generated by the corticotrope AtT-20 cells as a function of the extracellular calcium (Ca2+ ) concentration are reported. The recorded signals show a shape that clearly resembles the action potential waveform by suggesting a natural membrane penetration of the SiNWs. Additionally, the generation of synchronous signals observed under high Ca2+ content indicates the occurrence of a collective behavior in the AtT-20 cell population. This study extends the usefulness of MEA technology to the investigation of the electrical communication in cells of the pituitary gland, crucial in controlling several essential human functions, and provides new perspectives in recording with MEA the electrical activity of excitable cells.


Assuntos
Nanofios , Células Neuroendócrinas , Humanos , Silício , Microeletrodos , Miócitos Cardíacos
3.
Materials (Basel) ; 15(13)2022 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-35806740

RESUMO

Fluoride-based mouthwashes and gels are preventive measures in countering demineralization and caries but, modifying environmental acidity, can reduce the wet corrosion resistance of orthodontic alloys. To evaluate chemical stability, in vitro experiments were conducted on stainless steel and nickel-titanium wires, weighed before and after immersion in household fluorinated mouthwashes and gels, measuring weight variations and elution of metal ions from acid corrosion phenomena. Elution samples were analyzed by inductively coupled plasma mass spectrometry, detecting residual ion concentration, while surface changes were analyzed under scanning electron microscopy. Results showed stainless steel wires do not undergo significant erosion when exposed to most fluorinated mouthwashes but, at prolonged exposure, alloys elute gradually greater amounts of metals and Ni-Ti wires become more sensitive to some mouthwashes. Ions' elution varies considerably, especially for Ni-Ti wires, if exposed to household fluorinated gels, for which significant negative values were obtained. Changes, affecting wires' outer layer, negatively act on shiny appearance and luster, reducing corrosion resistance. Although examined orthodontic wires showed good chemical stability and low toxicity, surface corrosion from exposure to fluorinated agents was observed. Home use must be accompanied by clinician prescription and, for household dental gels, must follow manufacturers' recommendations, ensuring prophylactic action without damaging alloys surfaces.

4.
Sci Rep ; 8(1): 16717, 2018 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-30425252

RESUMO

The understanding of brain processing requires monitoring and exogenous modulation of neuronal ensembles. To this end, it is critical to implement equipment that ideally provides highly accurate, low latency recording and stimulation capabilities, that is functional for different experimental preparations and that is highly compact and mobile. To address these requirements, we designed a small ultra-flexible multielectrode array and combined it with an ultra-compact electronic system. The device consists of a polyimide microelectrode array (8 µm thick and with electrodes measuring as low as 10 µm in diameter) connected to a miniaturized electronic board capable of amplifying, filtering and digitalizing neural signals and, in addition, of stimulating brain tissue. To evaluate the system, we recorded slow oscillations generated in the cerebral cortex network both from in vitro slices and from in vivo anesthetized animals, and we modulated the oscillatory pattern by means of electrical and visual stimulation. Finally, we established a preliminary closed-loop algorithm in vitro that exploits the low latency of the electronics (<0.5 ms), thus allowing monitoring and modulating emergent cortical activity in real time to a desired target oscillatory frequency.


Assuntos
Encéfalo/fisiologia , Estimulação Elétrica , Eletrofisiologia/instrumentação , Encéfalo/citologia , Cinética , Microeletrodos , Software
5.
IEEE Trans Neural Syst Rehabil Eng ; 23(3): 342-50, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25073174

RESUMO

Electrocorticography (ECoG) is becoming a common tool for clinical applications, such as preparing patients for epilepsy surgery or localizing tumor boundaries, as it successfully balances invasiveness and information quality. Clinical ECoG arrays use millimeter-scale electrodes and centimeter-scale pitch and cannot precisely map neural activity. Higher-resolution electrodes are of interest for both current clinical applications, providing access to more precise neural activity localization and novel applications, such as neural prosthetics, where current information density and spatial resolution is insufficient to suitably decode signals for a chronic brain-machine interface. Developing such electrodes is not trivial because their small contact area increases the electrode impedance, which seriously affects the signal-to-noise ratio, and adhering such an electrode to the brain surface becomes critical. The most straightforward approach requires increasing the array conformability with flexible substrates while improving the electrode performance using materials with superior electrochemical properties. In this paper, we propose an ultra-flexible and conformable polyimide-based micro-ECoG array of submillimeter recording sites electrochemically coated with high surface area conductive polymer-carbon nanotube composites to improve their brain-electrical coupling capabilities. We characterized our devices both electrochemically and by recording from rat somatosensory cortex in vivo. The performance of the coated and uncoated electrodes was directly compared by simultaneously recording the same neuronal activity during multiwhisker deflection stimulation. Finally, we assessed the effect of electrode size on the extraction of somatosensory evoked potentials and found that in contrast to the normal high-impedance microelectrodes, the recording capabilities of our low-impedance microelectrodes improved upon reducing their size from 0.2 to 0.1 mm.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes , Eletroencefalografia/instrumentação , Nanotubos de Carbono , Polímeros , Animais , Encéfalo/fisiologia , Mapeamento Encefálico , Interfaces Cérebro-Computador , Impedância Elétrica , Técnicas Eletroquímicas , Eletrodos , Fenômenos Eletrofisiológicos , Potenciais Somatossensoriais Evocados , Masculino , Microeletrodos , Estimulação Física , Ratos , Ratos Long-Evans , Razão Sinal-Ruído , Vibrissas/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...