Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Ophthalmol Case Rep ; 11: 64-65, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29892726

RESUMO

To report a case of recurrent hypotony and choroidal effusion following trabeculectomy. OBSERVATIONS: A 70 year old male with advanced pseudoexfoliation glaucoma in both eyes underwent trabeculectomy in the left eye. Initially intraocular pressure (IOP) was controlled without topical therapy, but dorzolamide-timolol and brimonidine were added when IOP elevated above target. Aqueous suppressant glaucoma medications were thought to cause three episodes of hypotony resolving with discontinuation of these medications. Conclusions and Importance: Although hypotony and choroidal detachment associated with the use of aqueous suppressants is rare, it should be considered in patients with hypotony of unclear etiology following a glaucoma filtering procedure. Aqueous suppressants should be discontinued and it is recommended that the glaucoma drop regimen be switched to non-aqueous suppressants in patients with these findings.

2.
Int J Angiol ; 24(1): 71-4, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25780332

RESUMO

Appropriate placement of an inferior vena cava (IVC) filter necessitates imaging of the renal veins because when an IVC filter is deployed its tip should be at or below the inferior aspect of the inferiormost renal vein. Traditionally, imaging during placement of IVC filters has been with conventional cavography and fluoroscopy. Recently, intravascular ultrasound has been used for the same purpose but with additional expense. Morbidly obese patients often exceed the weight limit of fluoroscopy tables. In addition, short obese patients are at risk of falling from narrow fluoroscopy tables. For such patients, computed tomography (CT) guidance is a viable alternative to conventional fluoroscopic guidance. IVC placement was performed in the CT suite for two obese patients who exceeded the weight limits of the available fluoroscopy tables. In one case, a Vena-Tech filter (Braun Medical, Melsungen, Germany) was placed using CT fluoroscopy. In the second case, a Recovery (Bard, Murray Hill, NJ) filter was placed using intermittent limited z-axis scanning. In the first case, the filter was placed below the level of the renal veins and above the confluence of the iliac veins, which is acceptable placement. In the second case, with refinement of technique, the filter tip was placed less than 1 cm below the inferiormost renal vein, which is considered optimal placement. CT of the IVC precisely images the renal veins and can characterize their number and their confluence with the IVC. CT guidance is a viable alternative to fluoroscopic guidance for the placement of IVC filters in morbidly obese patients.

3.
Clin Imaging ; 39(3): 513-5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25631234

RESUMO

The presence of tumor thrombus in patients with lung cancer confers a risk of stroke and other end-organ ischemic events. This case highlights a potential role for electrocardiogram (ECG)-gated computed tomography (CT) in the diagnosis of this pathologic process. In this case, pulmonary vein thrombus was definitively identified by an ECG-CT following discordant results between CT and transthoracic echocardiogram. In addition, this case demonstrates how management decisions are affected by physician accessibility to and familiarity with specific imaging tests.


Assuntos
Eletrocardiografia , Células Neoplásicas Circulantes , Veias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Trombose Venosa/diagnóstico , Ecocardiografia , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...