Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Med Imaging ; 34(8): 1760-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25594962

RESUMO

The standing radiograph is used as a gold standard to diagnose spinal deformity including scoliosis, a medical condition defined as lateral spine curvature > 10°. However, the health concern of X-ray and large inter-observer variation of measurements on X-ray images have significantly restricted its application, particularly for scoliosis screening and close follow-up for adolescent patients. In this study, a radiation-free freehand 3-D ultrasound system was developed for scoliosis assessment using a volume projection imaging method. Based on the obtained coronal view images, two measurement methods were proposed using transverse process and spinous profile as landmarks, respectively. As a reliability study, 36 subjects (age: 30.1 ±14.5; male: 12; female: 24) with different degrees of scoliosis were scanned using the system to test the inter- and intra-observer repeatability. The intra- and inter-observer tests indicated that the new assessment methods were repeatable, with ICC larger than 0.92. Small intra- and inter-observer variations of measuring spine curvature were observed for the two measurement methods (intra-: 1.4 ±1.0° and 1.4 ±1.1°; inter-: 2.2 ±1.6° and 2.5 ±1.6°). The results also showed that the spinal curvature obtained by the new method had good linear correlations with X-ray Cobb's method (R2 = 0.8, p < 0.001, 29 subjects). These results suggested that the ultrasound volume projection imaging method can be a promising approach for the assessment of scoliosis, and further research should be followed up to demonstrate its potential clinical applications for mass screening and curve progression and treatment outcome monitoring of scoliosis patients.


Assuntos
Imageamento Tridimensional/métodos , Escoliose/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Adolescente , Adulto , Algoritmos , Feminino , Humanos , Masculino , Radiografia , Ultrassonografia , Adulto Jovem
2.
Ultrasonics ; 54(5): 1395-400, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24613414

RESUMO

Moisturizing creams and lotions are commonly used in daily life for beauty and treatment of different skin conditions such as dryness and wrinkling, and ultrasound stimulation has been used to enhance the delivery of ingredients into skin. However, there is a lack of convenient methods to study the effect of ultrasound stimulation on lotion absorption by skin in vivo. Ultrasound biomicroscopy was adopted as a viable tool in this study to investigate the effectiveness of ultrasound stimulation on the enhancement of lotion delivery into skin. The forearm skin of 10 male and 10 female young subjects was tested at three different sites, including two lotion treatment sites with (Ultrasound Equipment - UE ON) and without (UE OFF) ultrasound stimulation and a control site without any lotion treatment. 1 MHz ultrasound with a duty cycle of 1.7%, a spatial peak temporal peak pressure of 195 kPa and an average power of 0.43 W was used for the stimulation. The skin thickness before, immediately after (0 min), and 15 and 30 min after the treatment was measured by an ultrasound biomicroscopic system (55 MHz). It was found that the skin thickness significantly increased immediately after the lotion treatment for both UE ON (from 1.379 ± 0.187 mm to 1.466 ± 0.182 mm, p<0.001) and UE OFF (from 1.396 ± 0.193 mm to 1.430 ± 0.194 mm, p<0.001) groups. Further comparison between the two groups revealed that the skin thickness increase of UE ON group was significantly larger than that of UE OFF group (6.5 ± 2.4% vs. 2.5 ± 1.3%, p<0.001). Furthermore, it was disclosed that the enhancement of lotion delivery by ultrasound stimulation was more effective for the female subjects than the male subjects (7.6 ± 2.3% vs. 5.4 ± 2.0% immediately after treatment, p=0.017). In conclusion, this study demonstrated that ultrasound biomicroscopy was a feasible method for studying the effectiveness of lotion treatment in vivo, and ultrasound stimulation was effective to enhance the rate of lotion absorption into skin.


Assuntos
Técnicas Cosméticas/instrumentação , Emolientes/administração & dosagem , Microscopia Acústica , Pele/efeitos dos fármacos , Pele/diagnóstico por imagem , Absorção , Braço , Desenho de Equipamento , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Adulto Jovem
3.
Ultrasound Med Biol ; 39(6): 956-66, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23562022

RESUMO

Liver fibrosis is a kind of chronic damage of the liver and can lead to cirrhosis, one of the top 10 causes of death in the Western world. However, there is still a lack of noninvasive methods for diagnosing liver fibrosis. Fibroscan (Echosens, Paris, France), a device based on A-mode transient elastography, has shown promising results. In this study, a transient elastography system with real-time B-mode imaging for non-invasive liver fibrosis assessment, named Liverscan, was developed; its performance was tested and compared with that of the Fibroscan. A specific measurement probe was designed and fabricated with a B-mode ultrasound transducer fixed along the axis of a mechanical vibrator. It was integrated with the Liverscan to measure liver stiffness based on the shear wave propagation in liver tissues. The system was validated by mechanical indentation test using custom-made agar-gelatin phantoms with different stiffness. To further test its feasibility, in vivo measurements were conducted in 67 volunteers (age, 34 ± 3 years; body mass index, 21.3 ± 2.8 kg/m(2); Mean ± SD., 34 male and 33 female), including 20 patients with various liver diseases, and 28 (19 male and 9 female) being tested by both Liverscan and Fibroscan. A significant linear correlation between the stiffness measured by the mechanical indentation test and that by the Liverscan (r = 0.973; p < 0.001) was obtained. The in vivo liver stiffness measured by Liverscan was also correlated with that by Fibroscan significantly (r = 0.886; p < 0.001). There was a significant difference in liver stiffness between the 20 patients and the other healthy subjects (14.1 ± 3.4 kPa vs. 10.5 ± 2.1 kPa; p = 0.001). The intra- and inter-observer tests indicated that the measurements were repeatable with intra-class correlation coefficients being 0.987 (p < 0.001) and 0.988 (p < 0.001), respectively. This study demonstrated that Liverscan with a specifically designed probe was able to measure and differentiate liver of different stiffness using the established measurement protocol under the guidance of real-time B-mode ultrasound imaging.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Testes de Dureza/instrumentação , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/fisiopatologia , Adulto , Sistemas Computacionais , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...