BMC Pulm Med ; 23(1): 477, 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38017501

RESUMO

BACKGROUND: Continuous positive airway pressure (CPAP) therapy has profound effects in obesity hypoventilation syndrome (OHS). Current therapy initiation focuses on upper airway patency rather than the assessment of altered respiratory mechanics due to increased extrapulmonary mechanical load. METHODS: We aimed to examine the viability of intra-breath oscillometry in optimizing CPAP therapy for OHS. We performed intra-breath oscillometry at 10 Hz in the sitting and supine positions, followed by measurements at increasing CPAP levels (none-5-10-15-20 cmH2O) in awake OHS patients. We plotted intra-breath resistance and reactance (Xrs) values against flow (V') and volume (V) to identify tidal expiratory flow limitation (tEFL). RESULTS: Thirty-five patients (65.7% male) completed the study. We found a characteristic looping of the Xrs vs V' plot in all patients in the supine position revealing tEFL: Xrs fell with decreasing flow at end-expiration. Intra-breath variables representing expiratory decrease of Xrs became more negative in the supine position [end-expiratory Xrs (mean ± SD): -1.9 ± 1.8 cmH2O·s·L- 1 sitting vs. -4.2 ± 2.2 cmH2O·s·L- 1 supine; difference between end-expiratory and end-inspiratory Xrs: -1.3 ± 1.7 cmH2O·s·L- 1 sitting vs. -3.6 ± 2.0 cmH2O·s·L- 1 supine, p < 0.001]. Increasing CPAP altered expiratory Xrs values and loop areas, suggesting diminished tEFL (p < 0.001). 'Optimal CPAP' value (able to cease tEFL) was 14.8 ± 4.1 cmH2O in our cohort, close to the long-term support average of 13.01(± 2.97) cmH2O but not correlated. We found no correlation between forced spirometry values, patient characteristics, apnea-hypopnea index and intra-breath oscillometry variables. CONCLUSIONS: tEFL, worsened by the supine position, can be diminished by stepwise CPAP application in most patients. Intra-breath oscillometry is a viable method to detect tEFL during CPAP initiation in OHS patients and tEFL is a possible target for optimizing therapy in OHS patients.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Síndrome de Hipoventilação por Obesidade , Humanos , Masculino , Feminino , Síndrome de Hipoventilação por Obesidade/terapia , Oscilometria/métodos , Expiração , Mecânica Respiratória
2.
Front Pediatr ; 10: 867883, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35444964

RESUMO

Background: Oscillometry has been employed widely as a non-invasive and standardized measurement of respiratory function in children and adults; however, limited information is available on infants. Aims: To establish the within-session variability of respiratory impedance (Zrs), to characterize the degree and profile of intra-breath changes in Zrs and to assess their impact on conventional oscillometry in newborns. Methods: 109 healthy newborns were enrolled in the study conducted in the first 5 postpartum days during natural sleep. A custom-made wave-tube oscillometry setup was used, with an 8-48 Hz pseudorandom and a 16 Hz sinusoidal signal used for spectral and intra-breath oscillometry, respectively. A resistance-compliance-inertance (R-C-L) model was fitted to average Zrs spectra obtained from successive 30-s recordings. Intra-breath measures, such as resistance (Rrs) and reactance (Xrs) at the end-expiratory, end-inspiratory and maximum-flow points were estimated from three 90-s recordings. All natural and artifact-free breaths were included in the analysis. Results: Within-session changes in the mean R, C and L values, respectively, were large (mean coefficients of variation: 10.3, 20.3, and 26.6%); the fluctuations of the intra-breath measures were of similar degree (20-24%). Intra-breath analysis also revealed large swings in Rrs and Xrs within the breathing cycle: the peak-to-peak changes amounted to 93% (range: 32-218%) and 41% (9-212%), respectively, of the zero-flow Zrs magnitude. Discussion: Intra-breath tracking of Zrs provides new insight into the determinants of the dynamics of respiratory system, and highlights the biasing effects of mechanical non-linearities on the average Zrs data obtained from the conventional spectral oscillometry.

3.
Physiol Meas ; 43(4)2022 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-35263717

RESUMO

Objective. Recent studies in respiratory system impedance (Zrs) with single-frequency oscillometry have demonstrated the utility of novel intra-breath measures of Zrs in the detection of pathological alterations in respiratory mechanics. In the present work, we addressed the feasibility of extracting intra-breath information from Zrs data sets obtained with conventional oscillometry.Approach. Multi-frequency recordings obtained in a pulmonology practice were re-analysed to track the 11 Hz component of Zrs during normal breathing and compare the intra-breath measures to that obtained with a single 10 Hz signal in the same subjects. A nonlinear model was employed to simulate changes in Zrs in the breathing cycle. The values of resistance (R) and reactance (X) at end expiration and end inspiration and their corresponding differences (ΔRand ΔX) were compared.Main results. All intra-breath measures exhibited similar mean values at 10 and 11 Hz in each subject; however, the variabilities were higher at 11 Hz, especially for ΔRand ΔX. The poorer quality of the 11 Hz data was primarily caused by the overlapping of modulation side lobes of adjacent oscillation frequencies. This cross-talk was enhanced by double breathing frequency components due to flow nonlinearities.Significance. Retrospective intra-breath assessment of large or special data bases of conventional oscillometry can be performed to better characterise respiratory mechanics in different populations and disease groups. The results also have implications in the optimum design of multiple-frequency oscillometry (avoidance of densely spaced frequencies) and the use of filtering procedures that preserve the intra-breath modulation information.


Assuntos
Mecânica Respiratória , Sistema Respiratório , Impedância Elétrica , Humanos , Oscilometria/métodos , Estudos Retrospectivos
4.
Ann Allergy Asthma Immunol ; 127(3): 372-377, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34146698

RESUMO

BACKGROUND: Asthma control is not well reflected by spirometry, yet this is the most frequently used measure of lung function in asthma clinics. Oscillometry is an alternative technique suitable for those with severe asthma. OBJECTIVE: To investigate usefulness of oscillometry in subjects with severe asthma to determine which outcome variables best reflected asthma control. METHODS: Adults with severe asthma were recruited from a severe asthma clinic in Brazil. Oscillometry (conventional multifrequency measurements between 6 and 32 Hz; intrabreath tracking at 8 Hz) and spirometry were performed. Asthma control was determined by the asthma control test. RESULTS: A total of 60 adults were evaluated; mean age was 56.7 years. There was predominance of women (82%), and most patients (63%) reported onset of asthma symptoms in childhood or adolescence. There were no differences between controlled and uncontrolled asthma in spirometry. Uncontrolled asthma was associated with higher resistance (at 8 and 10 Hz) and more negative reactance (for 6, 8, and 10 Hz) (P < .05) on conventional oscillometry. Intrabreath oscillometry revealed significant differences between controlled and uncontrolled patients with asthma (P < .01 for changes in resistance and reactance between end expiration and end inspiration). The accuracy of the lung function tests in discriminating between controlled and uncontrolled asthma was higher for intrabreath variables (area under the curve = 0.65-0.72). CONCLUSION: Oscillometry, particularly the intrabreath technique, better reflected asthma control than spirometry measures. Our findings suggest that oscillometry may be a useful technique to aid management of severe asthma, with a potential to reflect loss of disease control.


Assuntos
Asma/diagnóstico , Oscilometria/métodos , Testes de Função Respiratória/métodos , Adulto , Idoso , Antiasmáticos/uso terapêutico , Asma/tratamento farmacológico , Asma/fisiopatologia , Feminino , Humanos , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade
5.
J Appl Physiol (1985) ; 129(3): 591-598, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32702268

RESUMO

Oscillometric measurements of respiratory system resistance (Rrs) in infants are usually made via the nasal pathways, which not only significantly contribute to overall Rrs but also introduce marked flow (V')-dependent changes. We employed intrabreath oscillometry in casts of the upper airways constructed from head CT images of 46 infants. We examined oscillometric nasal resistance (Rn) in upper airway casts with no respiratory flow (R0) and the effect of varying V' on Rn by simulating tidal breathing. A characteristic nonlinear relationship was found between Rn and V', exhibiting segmental linearity and a prominent breakpoint (V'bp) after log-log transformation. V'bp was linearly related to the preceding value of end-expiratory volume acceleration (V″eE; on average r2 = 0.96, P < 0.001). Rn depended on V', and R at end-expiration (ReE) showed a strong dependence on V″eE in every cast (r2 = 0.994, P < 001) with considerable interindividual variability. The intercept of the linear regression of ReE versus V″eE was found to be a close estimate of R0. These findings were utilized in reanalyzed Rrs data acquired in vivo in a small group of infants (n = 15). Using a graphical method to estimate R0 from ReE, we found a relative contribution of V'-dependent nonlinearity to total resistance of up to 33%. In conclusion, we propose a method for correcting the acceleration-dependent nonlinearity error in ReE. This correction can be adapted to estimate R0 from a single intrabreath oscillometric measurement, which would reduce the masking effects of the upper airways on the changes in the intrathoracic resistance.NEW & NOTEWORTHY Oscillometric measurements of respiratory system resistance (Rrs) in infants are usually made via the nasal pathways, which not only significantly contribute to overall Rrs but also introduce marked flow acceleration-dependent distortions. Here, we propose a method for correcting flow acceleration-dependent nonlinearity error based on in vitro measurements in 3D-printed upper airway casts of infants as well as in vivo measurements. This correction can be adapted to estimate Rrs from a single intrabreath oscillometric measurement.


Assuntos
Resistência das Vias Respiratórias , Respiração , Humanos , Lactente , Modelos Lineares , Oscilometria , Respiração Artificial
6.
Eur Respir J ; 49(2)2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28202552

RESUMO

Tracking of the within-breath changes of respiratory mechanics using the forced oscillation technique may provide outcomes that characterise the dynamic behaviour of the airways during normal breathing.We measured respiratory resistance (Rrs) and reactance (Xrs) at 8 Hz in 55 chronic obstructive pulmonary disease (COPD) patients and 20 healthy controls, and evaluated Rrs and Xrs as functions of gas flow (V') and volume (V) during normal breathing cycles. In 12 COPD patients, additional measurements were made at continuous positive airway pressure (CPAP) levels of 4, 8, 14 and 20 hPa.The Rrs and Xrsversus V' and V relationships displayed a variety of loop patterns, allowing characterisation of physiological and pathological processes. The main outcomes emerging from the within-breath analysis were the Xrsversus V loop area (AXV) quantifying expiratory flow limitation, and the tidal change in Xrs during inspiration (ΔXI) reflecting alteration in lung inhomogeneity in COPD. With increasing CPAP, AXV and ΔXI approached the normal ranges, although with a large variability between individuals, whereas mean Rrs remained unchanged.Within-breath tracking of Rrs and Xrs allows an improved assessment of expiratory flow limitation and functional inhomogeneity in COPD; thereby it may help identify the physiological phenotypes of COPD and determine the optimal level of respiratory support.


Assuntos
Resistência das Vias Respiratórias , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/terapia , Idoso , Estudos de Casos e Controles , Pressão Positiva Contínua nas Vias Aéreas , Impedância Elétrica , Expiração , Feminino , Humanos , Hungria , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Respiração , Testes de Função Respiratória/métodos
7.
Thorax ; 71(10): 907-15, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27178219

RESUMO

RATIONALE: Individual assessment of airway obstruction in preschool-age children requires sensitive and specific lung function methods with low demand of cooperation. Although the forced oscillation technique (FOT) is feasible in young children, conventional measurements of respiratory impedance (Zrs) have limited diagnostic power in individuals. OBJECTIVE: To find descriptors of within-breath Zrs that are sensitive indicators of airway obstruction during tidal breathing in children. METHODS: Zrs was measured with (i) a standard multifrequency FOT (4-26 Hz) to assess the mean values of resistance and reactance for whole breaths and (ii) a 10 Hz signal to track the within-breath changes. Various Zrs measures obtained in healthy children (n=75) and those with acute wheeze (n=31) were investigated with receiver operator characteristic (ROC) analysis. The cut-off values obtained for airway obstruction were then tested in children with recurrent wheeze (n=20) before and after administration of salbutamol. RESULTS: The largest area under the ROC curve (0.95) was observed for the tidal changes of resistance between the zero-flow values (ΔR). The ΔR cut-off value of 1.42 hPa s/L detected airway obstruction with sensitivity of 92% and specificity of 89% in children with acute wheeze and distinguished children with recurrent wheeze (16/20 above the cut-off value) from healthy children (22/23 below the cut-off value). Furthermore, ΔR significantly decreased after salbutamol in wheezy children but remained unchanged in healthy children. CONCLUSIONS: New lung function measure ΔR is able to detect airway obstruction with high sensitivity and specificity and is suitable for use in lung function testing in young children.


Assuntos
Resistência das Vias Respiratórias/fisiologia , Pneumopatias Obstrutivas/diagnóstico , Volume de Ventilação Pulmonar/fisiologia , Resistência das Vias Respiratórias/efeitos dos fármacos , Albuterol/farmacologia , Antropometria/métodos , Asma/complicações , Asma/diagnóstico , Asma/fisiopatologia , Broncodilatadores/farmacologia , Criança , Pré-Escolar , Feminino , Humanos , Pneumopatias Obstrutivas/complicações , Pneumopatias Obstrutivas/fisiopatologia , Masculino , Curva ROC , Recidiva , Testes de Função Respiratória/métodos , Sons Respiratórios/etiologia , Sons Respiratórios/fisiopatologia , Sensibilidade e Especificidade
8.
Pediatr Pulmonol ; 50(4): 344-52, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25154334

RESUMO

BACKGROUND: Lung function data in healthy newborn infants are scarce largely due to lack of suitable techniques, although data for developmental and prenatal exposure studies are much needed. We have modified the forced oscillation technique (FOT) for the measurement of respiratory mechanical impedance (Zrs) in unsedated sleeping infants in the first 3 days of life. METHODS: Zrs was measured during 30-s epochs of quiet sleep in term neonates born via spontaneous vaginal delivery with a non-invasive FOT between 8 and 48 Hz. Total respiratory resistance (R), compliance (C) and inertance (I) were obtained by fitting Zrs spectra. Cluster analysis was used to determine a set of minimal Zrs spectra representing optimal respiratory mechanics for each infant. RESULTS: Successful measurements were obtained in each of the first 3 days in 30/38 (78.9%) neonates. Group mean (± SD) values of R, C, I, and resonant frequency pooled for the 3 days were 45.9 ± 16.6 hPa s L(-1), 0.97 ± 0.21 ml hPa(-1), 0.082 ± 0.031 hPa s(2) L(-1) and 19.2 ± 3.2 Hz, respectively. Within-session variability represented by coefficient of variation was 5.34 ± 3.18% for R and 13.80 ± 8.57% for C. Greater between-session variability was observed for the individual infants; however, the only statistically significant change over time was a 13% increase in R from day 1 to day 2. Parameter interdependence was significant (r(2) = 0.63) between R and I reflecting the large contribution of the upper airways to the total Zrs. CONCLUSIONS: Noninvasive measurement of Zrs can be made in neonates during natural sleep with a high success rate, even in the first hours of life.


Assuntos
Oscilação da Parede Torácica , Mecânica Respiratória/fisiologia , Resistência das Vias Respiratórias/fisiologia , Análise por Conglomerados , Feminino , Humanos , Recém-Nascido , Masculino , Testes de Função Respiratória , Sono/fisiologia