Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 35(11): 2119-24, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24970546

RESUMO

BACKGROUND AND PURPOSE: Flow diverters are designed to occlude aneurysms while preserving flow to jailed arterial branches. We postulated that treatment success depended on the size of the aneurysm ostium or defect in the parent artery. MATERIALS AND METHODS: Flow diverter expansion and deformation were studied in silicone tubes with wall apertures of various sizes. Large and giant canine sidewall aneurysms, featuring a branch located immediately opposite the aneurysm, and a smaller 6- to 8-mm (group A, n = 6) or a larger 10- to 16-mm (group B, n = 6) ostium were created to study the effects of ostium size on aneurysm or branch occlusion by flow diverters. Angiographic results after deployment and at 3 months were scored by using an ordinal scale. The amount of neointima formation on the segment of the device overlying the aneurysm or the branch ostia was determined by specimen photography. RESULTS: The fusiform deformation of flow diverters was maximal with larger defects in silicone tubes. At 3 months, group B aneurysms showed worse angiographic results than group A aneurysms, with larger residual aneurysm volumes (P = .002). Neointimal coverage of the aneurysm ostia was more complete in group A compared with group B (P = .002). CONCLUSIONS: The effects of flow diversion may vary with the size of the aneurysm ostium.


Assuntos
Aneurisma/patologia , Aneurisma/cirurgia , Procedimentos Cirúrgicos Vasculares/instrumentação , Procedimentos Cirúrgicos Vasculares/métodos , Aneurisma/diagnóstico por imagem , Angiografia , Animais , Modelos Animais de Doenças , Cães , Stents
2.
Interv Neuroradiol ; 19(2): 180-5, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23693041

RESUMO

Haemorrhagic complications can occur following aneurysm treatment with flow diverters (FD), but the underlying mechanism remains unknown. We describe a case where deformation of the device may have contributed to the complication. A patient with a giant, previously unruptured cavernous aneurysm that extended intracranially to cause oedema of the internal capsule was treated with flow diversion. Treatment was followed by multiple episodes of peri-aneurysmal haemorrhages within eight days. A deformation of the device which occurred where it curved to cross the aneurysm neck created residual flows which, in the presence of a stent stenosis immediately beyond the neck, may have contributed to the observed ruptures. Following multiple haemorrhages the patient subsequently died. Autopsy demonstrated early red thrombus partially bridging the struts of the flow diverter, and intra-aneurysmal thrombus of various ages. Microscopic pathology showed an aneurysm wall consisting of collagen infiltrated with neutrophils, but the wall was absent near the cerebral peduncle, adjacent to the brain haemorrhage. Radiographs of the extracted specimen confirmed deformation of the FD construct, located at the transition zone of the stent, leading to increased pore size and porosity. The site of the deformation correlated with the angiographic presence of a continued blood inflow jet into the aneurysm. Stent deformation at the transition zone may promote persistent blood entry into the aneurysm, and in turn potentially contribute to haemorrhagic complications.


Assuntos
Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/etiologia , Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Aneurisma Intracraniano/complicações , Radiografia , Resultado do Tratamento
3.
AJNR Am J Neuroradiol ; 34(3): 570-6, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22899786

RESUMO

BACKGROUND AND PURPOSE: Endovascular treatment of wide-neck bifurcation aneurysms often results in incomplete occlusion or aneurysm recurrence. The goals of this study were to compare results of coil embolization with or without the assistance of self-expandable stents and to examine how stents may influence neointima formation. MATERIALS AND METHODS: Wide-neck bifurcation aneurysms were constructed in 24 animals and, after 4-6 weeks, were randomly allocated to 1 of 5 groups: 1) coil embolization using the assistance of 1 braided stent (n = 5); 2) coil embolization using the assistance of 2 braided stents in a Y configuration (n = 5); 3) coil embolization without stent assistance (n = 6); 4) Y-stenting alone (n = 4); and 5) untreated controls (n = 4). Angiographic results were compared at baseline and at 12 weeks, by using an ordinal scale. Neointima formation at the neck at 12 weeks was compared among groups by using a semiquantitative grading scale. Bench studies were performed to assess stent porosities. RESULTS: Initial angiographic results were improved with single stent-assisted coiling compared with simple coiling (P = .013). Angiographic results at 12 weeks were improved with any stent assistance (P = .014). Neointimal closure of the aneurysm neck was similar with or without stent assistance (P = .908), with neointima covering coil loops but rarely stent struts. Y-stent placement alone had no therapeutic effect. Bench studies showed that porosities can be decreased with stent compaction, but a relatively stable porous transition zone was a limiting factor. CONCLUSIONS: Stent-assisted coiling may improve results of embolization by allowing more complete initial coiling, but these high-porosity stents did not provide a scaffold for more complete neointimal closure of aneurysms.


Assuntos
Prótese Vascular , Procedimentos Endovasculares/instrumentação , Aneurisma Intracraniano/cirurgia , Trombólise Mecânica/instrumentação , Stents , Animais , Terapia Combinada/instrumentação , Cães , Procedimentos Endovasculares/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Aneurisma Intracraniano/diagnóstico por imagem , Radiografia , Resultado do Tratamento
4.
AJNR Am J Neuroradiol ; 34(3): 596-602, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22878007

RESUMO

BACKGROUND AND PURPOSE: Braided self-expandable stents and flow diverters of uniform construction may develop zones of heterogeneous porosity in vivo. Unwanted stenoses may also occur at the extremities of the device. We studied these phenomena in dedicated benchtop experiments. MATERIALS AND METHODS: Five braided devices of decreasing porosity were studied. To simulate discrepancies in diameters between the landing zones of the parent vessel and the aneurysm neck area, device extremities were inserted into silicone tubes of various diameters (2-3 mm), leaving the midportion free to react to experimental manipulations, which included axial approximation of the tubes (0-7 mm), and curvature (0-135°), with or without axial compression (0-2 mm). The length of the landing zone was sequentially decreased to study terminal device stenosis. RESULTS: All devices adopted a conformation characterized by 3 different zones: bilateral landing zones, a middle compaction zone, and 2 transition zones. It is possible, during deployment, to compact stents and FDs to decrease porosity, but a limiting factor was the transition zone, which remained relatively unchanged and of higher porosity than the expansion zone. Length of the transition zone increased when devices were constrained in smaller tubes. Heterogeneities in porosity with compaction and curvatures were predictable and followed simple geometric rules. Extremity stenoses occurred increasingly with decreasing length of the landing zone. CONCLUSIONS: Braided self-expandable devices show predictable changes in porosity according to device size, vessel diameter, and curvature. Adequate landing zones are required to prevent terminal device stenosis.


Assuntos
Prótese Vascular , Falha de Prótese , Stents , Desenho de Equipamento , Análise de Falha de Equipamento , Porosidade
5.
AJNR Am J Neuroradiol ; 34(2): 346-53, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23153870

RESUMO

BACKGROUND AND PURPOSE: The relationship between aneurysm dimensions, flow, thrombosis, and rupture remains poorly understood. We attempted to clarify this relationship by exploring various swine aneurysm models. MATERIALS AND METHODS: Bilateral carotid aneurysms were constructed according to 3 protocols in 24 animals: small aneurysms with wide necks (group 1; n = 6 animals); small aneurysms with small necks (group 2; n = 4 animals), and giant aneurysms with large necks (group 3; n = 14 animals). Group 3 included 3 subgroups, related to testing the model in various experimental conditions: The neck was clipped in 3 animals; venous pouches lacked an endothelial lining in 4 animals; and 7 were control animals. Animals were followed until rupture, or for 1-4 weeks. Angiography was performed postoperatively and before euthanasia. We studied lesion pathology, paying attention to thrombosis, recanalization, wall composition, and perianeurysmal hemorrhage. RESULTS: Groups differed significantly in aneurysm dimensions and aspect ratio (P = .002). Ruptures occurred more frequently in animals with untreated giant aneurysms (7/7) than in animals with small wide-neck (0/6) or small-neck (2/4) aneurysms (P = .002). Ruptures occurred only in animals with thrombosed aneurysms. Lesions lacking an endothelial lining and 5 of 6 clipped venous pouches thrombosed but did not rupture. One giant lesion ruptured despite complete clipping. The wall was deficient in α-actin and was infiltrated with inflammatory cells and erythrocytes in all thrombosed cases, ruptured or not. Ruptures were associated with recanalizing channels in 9 of 10 cases. CONCLUSIONS: Thrombosis, inflammation, and recanalization may precipitate aneurysmal ruptures in a swine model.


Assuntos
Aneurisma Roto/fisiopatologia , Doenças das Artérias Carótidas/fisiopatologia , Aneurisma Intracraniano/fisiopatologia , Trombose/fisiopatologia , Aneurisma Roto/complicações , Aneurisma Roto/patologia , Animais , Biópsia , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/patologia , Doenças das Artérias Carótidas/complicações , Doenças das Artérias Carótidas/patologia , Angiografia Cerebral , Circulação Cerebrovascular/fisiologia , Modelos Animais de Doenças , Aneurisma Intracraniano/complicações , Aneurisma Intracraniano/patologia , Índice de Gravidade de Doença , Sus scrofa , Trombose/complicações , Trombose/patologia , Vasculite/complicações , Vasculite/patologia , Vasculite/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...