Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
NMR Biomed ; : e5144, 2024 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-38556777

RESUMO

OBJECTIVES: To evaluate the role of combined intravoxel incoherent motion and diffusion kurtosis imaging (IVIM-DKI) and their machine-learning-based texture analysis for the detection and assessment of severity in prostate cancer (PCa). MATERIALS AND METHODS: Eighty-eight patients underwent MRI on a 3 T scanner after giving informed consent. IVIM-DKI data were acquired using 13 b values (0-2000 s/mm2) and analyzed using the IVIM-DKI model with the total variation (TV) method. PCa patients were categorized into two groups: clinically insignificant prostate cancer (CISPCa) (Gleason grade ≤ 6) and clinically significant prostate cancer (CSPCa) (Gleason grade ≥ 7). One-way analysis-of-variance, t test, and receiver operating characteristic analysis was performed to measure the discriminative ability to detect PCa using IVIM-DKI parameters. A chi-square test was used to select important texture features of apparent diffusion coefficient (ADC) and IVIM-DKI parameters. These selected texture features were used in an artificial neural network for PCa detection. RESULTS: ADC and diffusion coefficient (D) were significantly lower (p < 0.001), and kurtosis (k) was significantly higher (p < 0.001), in PCa as compared with benign prostatic hyperplasia (BPH) and normal peripheral zone (PZ). ADC, D, and k showed high areas under the curves (AUCs) of 0.92, 0.89, and 0.88, respectively, in PCa detection. ADC and D were significantly lower (p < 0.05) as compared with CISPCa versus CSPCa. D for detecting CSPCa was high, with an AUC of 0.63. A negative correlation of ADC and D with GS (ADC, ρ = -0.33; D, ρ = -0.35, p < 0.05) and a positive correlation of k with GS (ρ = 0.22, p < 0.05) were observed. Combined IVIM-DKI texture showed high AUC of 0.83 for classification of PCa, BPH, and normal PZ. CONCLUSION: D, f, and k computed using the IVIM-DKI model with the TV method were able to differentiate PCa from BPH and normal PZ. Texture features of combined IVIM-DKI parameters showed high accuracy and AUC in PCa detection.

2.
Cancers (Basel) ; 16(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38539565

RESUMO

The spectral quality of magnetic resonance spectroscopic imaging (MRSI) can be affected by strong magnetic field inhomogeneities, posing a challenge for 3D-MRSI's widespread clinical use with standard scanner-equipped 2nd-order shim coils. To overcome this, we designed an empirical unified shim-RF head coil (32-ch RF receive and 51-ch shim) for 3D-MRSI improvement. We compared its shimming performance and 3D-MRSI brain coverages against the standard scanner shim (2nd-order spherical harmonic (SH) shim coils) and integrated parallel reception, excitation, and shimming (iPRES) 32-ch AC/DC head coil. We also simulated a theoretical 3rd-, 4th-, and 5th-order SH shim as a benchmark to assess the UNIfied shim-RF coil (UNIC) improvements. In this preliminary study, the whole-brain coverage was simulated by using B0 field maps of twenty-four healthy human subjects (n = 24). Our results demonstrated that UNIC substantially improves brain field homogeneity, reducing whole-brain frequency standard deviations by 27% compared to the standard 2nd-order scanner shim and 17% compared to the iPRES shim. Moreover, UNIC enhances whole-brain coverage of 3D-MRSI by up to 34% compared to the standard 2nd-order scanner shim and up to 13% compared to the iPRES shim. UNIC markedly increases coverage in the prefrontal cortex by 147% and 47% and in the medial temporal lobe and temporal pole by 29% and 13%, respectively, at voxel resolutions of 1.4 cc and 0.09 cc for 3D-MRSI. Furthermore, UNIC effectively reduces variations in shim quality and brain coverage among different subjects compared to scanner shim and iPRES shim. Anticipated advancements in higher-order shimming (beyond 6th order) are expected via optimized designs using dimensionality reduction methods.

3.
Bioengineering (Basel) ; 11(3)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38534485

RESUMO

B0 field inhomogeneity is a long-lasting issue for Cardiac MRI (CMR) in high-field (3T and above) scanners. The inhomogeneous B0 fields can lead to corrupted image quality, prolonged scan time, and false diagnosis. B0 shimming is the most straightforward way to improve the B0 homogeneity. However, today's standard cardiac shimming protocol requires manual selection of a shim volume, which often falsely includes regions with large B0 deviation (e.g., liver, fat, and chest wall). The flawed shim field compromises the reliability of high-field CMR protocols, which significantly reduces the scan efficiency and hinders its wider clinical adoption. This study aims to develop a dual-channel deep learning model that can reliably contour the cardiac region for B0 shim without human interaction and under variable imaging protocols. By utilizing both the magnitude and phase information, the model achieved a high segmentation accuracy in the B0 field maps compared to the conventional single-channel methods (Dice score: 2D-mag = 0.866, 3D-mag = 0.907, and 3D-mag-phase = 0.938, all p < 0.05). Furthermore, it shows better generalizability against the common variations in MRI imaging parameters and enables significantly improved B0 shim compared to the standard method (SD(B0Shim): Proposed = 15 ± 11% vs. Standard = 6 ± 12%, p < 0.05). The proposed autonomous model can boost the reliability of cardiac shimming at 3T and serve as the foundation for more reliable and efficient high-field CMR imaging in clinical routines.

4.
Bioengineering (Basel) ; 10(1)2023 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-36671655

RESUMO

Non-invasive characterization of pancreatic masses aids in the management of pancreatic lesions. Intravoxel incoherent motion-diffusion kurtosis imaging (IVIM-DKI) and machine learning-based texture analysis was used to differentiate pancreatic masses such as pancreatic ductal adenocarcinoma (PDAC), pancreatic neuroendocrine tumor (pNET), solid pseudopapillary epithelial neoplasm (SPEN), and mass-forming chronic pancreatitis (MFCP). A total of forty-eight biopsy-proven patients with pancreatic masses were recruited and classified into pNET (n = 13), MFCP (n = 6), SPEN (n = 4), and PDAC (n = 25) groups. All patients were scanned for IVIM-DKI sequences acquired with 14 b-values (0 to 2500 s/mm2) on a 1.5T MRI. An IVIM-DKI model with a 3D total variation (TV) penalty function was implemented to estimate the precise IVIM-DKI parametric maps. Texture analysis (TA) of the apparent diffusion coefficient (ADC) and IVIM-DKI parametric map was performed and reduced using the chi-square test. These features were fed to an artificial neural network (ANN) for characterization of pancreatic mass subtypes and validated by 5-fold cross-validation. Receiver operator characteristics (ROC) analyses were used to compute the area under curve (AUC). Perfusion fraction (f) was significantly higher (p < 0.05) in pNET than PDAC. The f showed better diagnostic performance for PDAC vs. MFCP with AUC:0.77. Both pseudo-diffusion coefficient (D*) and f for PDAC vs. pNET showed an AUC of 0.73. ADC and diffusion coefficient (D) showed good diagnostic performance for pNET vs. MFCP with AUC: 0.79 and 0.76, respectively. In the TA of PDAC vs. non-PDAC, f and combined IVIM-DKI parameters showed high accuracy ≥ 84.3% and AUC ≥ 0.84. Mean f and combined IVIM-DKI parameters estimated that the IVIM-DKI model with TV texture features has the potential to be helpful in characterizing pancreatic masses.

5.
MAGMA ; 35(4): 609-620, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34052899

RESUMO

OBJECTIVE: To implement an advanced spatial penalty-based reconstruction to constrain the intravoxel incoherent motion (IVIM)-diffusion kurtosis imaging (DKI) model and investigate whether it provides a suitable alternative at 1.5 T to the traditional IVIM-DKI model at 3 T for clinical characterization of prostate cancer (PCa) and benign prostatic hyperplasia (BPH). MATERIALS AND METHODS: Thirty-two patients with biopsy-proven PCa were recruited for MRI examination (n = 16 scanned at 1.5 T, n = 16 scanned at 3 T). Diffusion-weighted imaging (DWI) with 13 b values (b = 0 to 2000 s/mm2 up to 3 averages, 1.5 T: TR = 5.774 s, TE = 81 ms and 3 T: TR = 4.899 s, TE = 100 ms), T2-weighted, and T1-weighted imaging were used on the 1.5 T and 3 T MRI scanner, respectively. The IVIM-DKI signal was modeled using the traditional IVIM-DKI model and a novel model in which the total variation (TV) penalty function was combined with the traditional model to optimize non-physiological variations. Paired and unpaired t-tests were used to compare intra-scanner and scanner group differences in IVIM-DKI parameters obtained using the novel and the traditional models. Analysis of variance with post hoc test and receiver operating characteristic (ROC) curve analysis were used to assess the ability of parameters obtained using the novel model (at 1.5 T) and the traditional model (at 3 T) to characterize prostate lesions. RESULTS: IVIM-DKI modeled using novel model with TV spatial penalty function at 1.5 T, produced parameter maps with 50-78% lower coefficient of variation (CV) than traditional model at 3 T. Novel model estimated higher D with lower D*, f and k values at both field strengths compared to traditional model. For scanner differences, the novel model at 1.5 T estimated lower D* and f values as compared to traditional model at 3 T. At 1.5 T, D and f values were significantly lower with k values significantly higher in tumor than BPH and healthy tissue. D (AUC: 0.98), f (AUC: 0.82), and k (AUC: 0.91) parameters estimated using novel model showed high diagnostic performance in cancer lesion detection at 1.5 T. DISCUSSION: In comparison with the IVIM-DKI model at 3 T, IVIM-DKI signal modeled with the TV penalty function at 1.5 T showed lower estimation errors. The proposed novel model can be utilized for improved detection of prostate lesions.


Assuntos
Imagem de Tensor de Difusão , Hiperplasia Prostática , Neoplasias da Próstata , Imagem de Tensor de Difusão/métodos , Humanos , Masculino , Movimento (Física) , Hiperplasia Prostática/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Reprodutibilidade dos Testes
6.
MAGMA ; 32(5): 519-527, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31214819

RESUMO

OBJECTIVE: To investigate the effect of number and combination of b values used on the accuracy of estimated Intravoxel Incoherent Motion (IVIM) parameters using simulation and clinical data. MATERIALS AND METHODS: Simulations with seven combinations of b values were performed for 4, 6, 8, and 13 numbers of b values with six different values of D, D*, and f parameters. Two methodologies were implemented for IVIM analysis: standard biexponential model (BE) and biexponential model with total variation penalty function (BE + TV). Clinical data set of six patients with prostate cancer was retrospectively analyzed using 4, 8, and 13 b values. RESULTS: BE + TV method showed lesser error and lower variability in simulation and clinical data, respectively. 8 and 13 b values showed good agreement in the values of parameters estimated with high correlation coefficient (ρ = 0.83-0.93). Clinical data showed high spurious noise with lower b values [4 b values leading to high coefficient of variation (CV); however, substantially, lower CV was observed with 8 and 13 b values]. DISCUSSION: BE model with TV penalty function is robust to combination of b values used for IVIM analysis. Combination of 8 b values provided a reasonably good accuracy in IVIM parameters.


Assuntos
Imagem de Difusão por Ressonância Magnética , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Algoritmos , Simulação por Computador , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Perfusão , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...