Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 156
Filtrar
2.
Ther Apher ; 5(4): 270-82, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11724512

RESUMO

The use of membranes in blood processing range from the use of large-pore structures for filtration of blood for the removal of large particles (>20 microm transfusion filters) to membranes for the dialysis of blood for the removal of low molecular weight solutes in the treatment of renal failure. Within the past 20 years, membranes have been applied in the separation of plasma from whole blood. Compared to centrifugal plasma separation membrane, plasma separation is preferred when used with online plasma fractionation since the plasma is free of cells. In addition, membranes have also been applied in the online treatment of plasma for the selective removal of macromolecules in selected disease states obviating the need for plasma replacement products. The membranes used for plasma separation and fractionation may be distinguished from conventional dialysis membranes and high-flux membranes used in hemofiltration by their very high or select passage of plasma proteins. Membrane techniques are simple and safe to apply and can be competitive to other plasma separation and treatment technologies.


Assuntos
Remoção de Componentes Sanguíneos , Membranas Artificiais , Fracionamento Celular , Hemofiltração , Hemorreologia , Humanos
3.
Ther Apher ; 5(3): 193-206, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11467756

RESUMO

The developments in apheresis technologies and techniques and their clinical applications worldwide are technologically, sociologically, and economically driven. In the past, apheresis survey statistics have highlighted both the differences by geographical region in clinical practices and in the types of technologies utilized. While a national view of apheresis is critically important, an international view of apheresis may be more representative overall of this therapeutic modality than national results that are highly dependent on the local economics and the available technologies. These regional differences have provided a basis for the scientific and clinical assessments of these apheresis technologies and their clinical outcomes and have impacted the marketing and business developments of new technologies worldwide. The results of the International Apheresis Registry for 2000 reporting on 39 centers on 4 continents are presented. This survey collected data on 1,080 patients for a total of 15,257 treatments. Information gathered included patient demographics, medical history, treatment diagnoses, treatment specifics (type, methodology, access type, anticoagulants, drugs, equipment usage), side effects, clinical response, and payment provider. As in the prior International Apheresis Registry for 1983, the survey results highlighted the regional differences in apheresis usage and treatment specifics, indicating that an international overview of apheresis may be more representative of the impact of this therapeutic modality.


Assuntos
Remoção de Componentes Sanguíneos/estatística & dados numéricos , Sistema de Registros/estatística & dados numéricos , Avaliação da Tecnologia Biomédica/estatística & dados numéricos , Adulto , Ásia , Remoção de Componentes Sanguíneos/instrumentação , Remoção de Componentes Sanguíneos/métodos , América Central , Coleta de Dados/estatística & dados numéricos , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte , América do Sul
4.
Artif Organs ; 25(2): 75-88, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11251473

RESUMO

With the first clinical use of the artificial kidney over 5 decades ago, we entered into a new era of medicine-that of substitutive and replacement therapy. Yet it took nearly another 15 years until chronic treatment was possible and nearly another 15 years until widespread treatment was possible due to government support. The history of development and clinical use of other artificial organ technologies such as the artificial heart and heart valves, the artificial lung, artificial blood, joint replacements, the artificial liver, the artificial pancreas, immunologic, metabolic, and neurologic support, neurocontrol, and tissue substitutes have followed similar long development paths. Despite their relatively long time to be put into clinical use, the contributions of artificial organ technologies to the betterment of mankind have been unquestionably a major success. For example, modern day surgery would not be possible without heart-lung support, and the technologies for heart support have led to the development of various minimally invasive technologies. The powerful impact that artificial organ technologies presently has on our lives is seen through the statistic that in the U.S.A. nearly 1 in 10 persons is living with an implanted medical device. With the aging of our population and the improvements in technologies, these numbers will only increase.


Assuntos
Órgãos Artificiais/tendências , Tecnologia Biomédica , Animais , Órgãos Artificiais/economia , Órgãos Artificiais/normas , Análise Custo-Benefício , Genômica , Coração Artificial/economia , Coração Artificial/normas , Humanos , Rins Artificiais/economia , Rins Artificiais/normas , Fígado Artificial/economia , Fígado Artificial/normas , Robótica , Análise de Sobrevida , Resultado do Tratamento , Estados Unidos , Interface Usuário-Computador
5.
Artif Organs ; 25(12): 945, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11843760
6.
ASAIO J ; 46(6): S69-72, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11110297

RESUMO

Prions are novel proteinaceous-infectious agents that have been implicated in transmissible spongiform encephalopathies. It is now generally accepted that noninfectious prion proteins are normally produced by the host and may undergo a conformational change to an abnormal, pathologic form, which appears to be responsible for disease symptoms. Many methods of decontamination and sterilization are claimed to be ineffective against prion proteins. Incidences of iatrogenic transmission of prions due to medical devices have been reported, and the recommended clinical practices when handling suspected cases are reviewed. Recent results with a peracetic acid based sterilant indicate that it may be a safe and effective means of prion inactivation on medical devices.


Assuntos
Equipamentos e Provisões/efeitos adversos , Doenças Priônicas/transmissão , Animais , Desinfecção/métodos , Humanos , Ácido Peracético , Doenças Priônicas/etiologia , Doenças Priônicas/prevenção & controle , Segurança , Esterilização/métodos
8.
J AOAC Int ; 83(2): 269-75, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10772163

RESUMO

The AOAC sporicidal method (966.04) recommends the use of porcelain penicylinders and black waxed silk sutures as carriers for demonstrating the sporicidal activity of sterilants. However, the silk carriers are not suitable for evaluating the sporicidal efficacy of oxidizing agents, and an inert polyester material (Dacron) is recommended as an alternative. Dacron provides an equivalent microbial and physical challenge to silk. Microbiologically, both materials demonstrated similar HCI resistance, which is required by the AOAC test, as well as equivalent spore loading and spore wash-off. Electron microscopy showed that both materials present the same braided microstructure, providing an equivalent physical challenge to the test sterilant. Dacron was more consistent than silk, and did not require extraction prior to spore loading. The extraction method for black waxed silk was variable and incomplete, which may compromise the activity of oxidizing sterilants and add to method variability. Silk was also structurally altered in the presence of oxidizing sterilants and increased sterilant degradation. Dacron did not affect the sterilant and was inert in the presence of oxidizing agents. Dacron sutures are proposed as inert alternatives to silk for evaluating the sporicidal efficacy of oxidizing agents.


Assuntos
Oxidantes/farmacologia , Polietilenotereftalatos , Esporos Bacterianos/efeitos dos fármacos , Esterilização , Ácido Clorídrico/farmacologia , Proteínas de Insetos , Cinética , Microscopia Eletrônica , Microscopia Eletrônica de Varredura , Ácido Peracético/química , Polietilenotereftalatos/química , Seda , Resistência à Tração
17.
Med Eng Phys ; 20(5): 383-92, 1998 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9773691

RESUMO

A model describing the sieving and transmembrane pressure behavior of plasma filtration is developed and numerically simulated. The model assumes a mechanistic criteria for particle passage through a membrane with cylindrical pores. The initial pore diameter distribution and porosity are assumed to be known. Model inputs include the particle diameter distribution, concentration and total flow rate of the permeate plasma solution. Outputs of the model include transmembrane pressure, the time-averaged sieving coefficients, and size distributions of the deposited particles and accumulated filtrate particles. Optimal filtration is characterized by high, stable sieving coefficients for desired particles, high retention of larger particles and relatively small increases in transmembrane pressure. These characteristics are realized for membranes with mean pore diameters equal to or slightly larger than mean permeate particle diameters. Simulations demonstrate that the incorporation of membrane properties into models of plasma filtration is both significant and readily possible.


Assuntos
Hemofiltração , Modelos Biológicos , Plasma/fisiologia , Fenômenos Biofísicos , Biofísica , Proteínas Sanguíneas/isolamento & purificação , Hemofiltração/estatística & dados numéricos , Humanos , Mecânica , Membranas Artificiais , Porosidade
18.
J Thorac Cardiovasc Surg ; 114(3): 448-60, 1997 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9305199

RESUMO

OBJECTIVE(S): The reuse of disposable devices is a potential source of significant cost savings to hospitals. Venous and arterial perfusion cannulas under new and reused conditions were selected to identify the clinical, safety, technical, logistic, and economic issues that must be addressed to realize these savings. METHODS: Single- and dual-stage venous and arterial cannulas from two manufacturers were tested when new, after initial clinical use, and after a single clinical use plus up to nine simulated reuses. Reuse was simulated by end-to-end bending, coupling and uncoupling of the connectors, and by two 1-hour soaks in plasma at 4 degrees and 40 degrees C, respectively. Cannulas were decontaminated and then processed by a peracetic acid-based liquid chemical sterilization system after each use/reuse. Sterilization was validated by eliminating Bacillus subtilis spores from the cannulas on each of five consecutive cycles. Cannulas were tested for physical changes, functional integrity, biocompatibility, and in vivo performance in sheep. A cost analysis was also performed. RESULTS: Sterilization was successfully achieved. Mechanical changes were less than 20% on all variables studied and were undetectable by experienced cardiac surgeons in selective evaluation. No clinically important differences were found between new and reused cannulas, even after nine simulated reuses. Reusing cannulas four times would reduce the cost per procedure from $53 to $19 (64%). CONCLUSIONS: Preliminary data suggest that the perfusion cannulas tested can be safely and efficaciously used five times. Limited reuse of these disposable cannulas is technically feasible and cost-effective. Cannula reuse would result in a small incremental savings; however, with more expensive devices and higher-volume sterilization procedures, the savings could be considerably greater. This program provides a model for evaluation of other single-use medical devices for reuse.


Assuntos
Cateterismo Periférico/instrumentação , Equipamentos Descartáveis , Animais , Bacillus subtilis , Materiais Biocompatíveis , Cateterismo Periférico/economia , Análise Custo-Benefício , Custos e Análise de Custo , Equipamentos Descartáveis/economia , Contaminação de Equipamentos , Reutilização de Equipamento/economia , Estudos de Viabilidade , Humanos , Teste de Materiais , Perfusão/instrumentação , Ovinos , Esterilização , Resistência à Tração , Anormalidade Torcional
19.
Biomed Instrum Technol ; 31(3): 248-9, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9181243

RESUMO

The reuse of disposable devices is a potential source of significant cost savings to hospitals. Venous and arterial perfusion cannulae under new and reused conditions were selected to identify the clinical, safety, technical, logistic, and economic issues that must be addressed to realize these savings. Single- and dual-stage venous and arterial cannulae from two manufacturers were tested when new, after initial clinical use, and after a single clinical use plus up to nine simulated reuses. Reuse was simulated by end-to-end bending, coupling and uncoupling the connectors, and by two 1-hour soaks in plasma at 4 degrees C and 40 degrees C, respectively. Cannulae were decontaminated and then sterilized by a peracetic acid based liquid chemical sterilization system following each use/reuse. Sterilization was validated by eliminating Bacillus subtilis spores from the cannulae on each of five consecutive cycles. Cannulae were tested for physical changes, functional integrity, biocompatibility, and in vivo performance in sheep. A cost minimization analysis was also performed. No clinically important differences were found between new and reused cannulae, even after nine simulated reuses. Mechanical changes were less than 20% on all variables studied and were undetectable by experienced cardiac surgeons in selective evaluation. Sterilization was successfully achieved. Reusing cannulae for times would reduce the cost per procedure from $53 to $19 (64%). Perfusion cannulae tested can be safely and efficaciously used five times. This study suggests that reuse would result in a small incremental savings; however, with more expensive devices and higher-volume sterilization procedures, the savings could be exponentially greater. Although this study demonstrates that it may be technically feasible and cost-effective to reuse disposable cannulae, the U.S. Food and Drug Administration does not sanction the reuse of disposable cannulae.


Assuntos
Cateterismo/instrumentação , Equipamentos Descartáveis , Perfusão/instrumentação , Animais , Bacillus subtilis/efeitos dos fármacos , Materiais Biocompatíveis , Procedimentos Cirúrgicos Cardíacos/instrumentação , Cateterismo/economia , Temperatura Baixa , Redução de Custos , Análise Custo-Benefício , Desinfetantes/uso terapêutico , Equipamentos Descartáveis/economia , Elasticidade , Desenho de Equipamento , Reutilização de Equipamento/economia , Segurança de Equipamentos , Estudos de Viabilidade , Custos Hospitalares , Temperatura Alta , Humanos , Ácido Peracético/uso terapêutico , Perfusão/economia , Plasma , Ovinos , Esporos Bacterianos/efeitos dos fármacos , Esterilização/métodos , Propriedades de Superfície , Estados Unidos , United States Food and Drug Administration
20.
Artif Organs ; 20(4): 346-54, 1996 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9139623

RESUMO

Since the application by Thompson et al. in 1975 of plasma exchange for the treatment of 2 patients with familial hyperlipidemia, plasma purification techniques for selective low-density lipoprotein (LDL) removal (i.e., LDL apheresis) have been developed and adopted for the management of this disease. Thermofiltration is one of the LDL apheresis systems that utilizes membrane techniques developed by Nose and Malchesky's group in 1985. This article reviews its rationale, in vitro studies, animal studies, and clinical investigation. Thermofiltration effectively and selectively removes LDL cholesterol while retaining in the plasma physiologically important macromolecules such as albumin and high-density lipoprotein (HDL) cholesterol. Based on the global view of the treatment of atherosclerosis by LDL apheresis, membrane techniques are as effective, safe, and simpler to apply than other methods. Additionally, these methods are effective for the removal of lipoprotein (a) and fibrinogen; thus, they can address the needs in these application areas.


Assuntos
Arteriosclerose/terapia , LDL-Colesterol/isolamento & purificação , Membranas Artificiais , Plasmaferese/tendências , Animais , Precipitação Química , HDL-Colesterol/sangue , LDL-Colesterol/sangue , VLDL-Colesterol/sangue , Ensaios Clínicos como Assunto , Sulfato de Dextrana/química , Sulfato de Dextrana/metabolismo , Filtração , Heparina/farmacologia , Temperatura Alta , Humanos , Imunoadsorventes/química , Imunoadsorventes/metabolismo , Peso Molecular , Tamanho da Partícula , Plasmaferese/normas , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...