1.
Biomed Opt Express ; 4(2): 245-59, 2013 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-23411636

RESUMO

We report a newly developed high speed 1050nm spectral domain optical coherence tomography (SD-OCT) system for imaging posterior segment of human eye. The system is capable of an axial resolution at ~10 µm in air, an imaging depth of 6.1 mm in air, a system sensitivity fall-off at ~6 dB/3mm and an imaging speed of 120,000 A-scans per second. We experimentally demonstrate the system's capability to perform phase-resolved imaging of dynamic blood flow within retina, indicating high phase stability of the SDOCT system. Finally, we show an example that uses this newly developed system to image posterior segment of human eye with a large view of view (10 × 9 mm(2)), providing detailed visualization of microstructural features from anterior retina to posterior choroid. The demonstrated system parameters and imaging performances are comparable to those that a typical 1 µm swept source OCT would deliver for retinal imaging.

2.
J Biomed Opt ; 18(1): 16012, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23334687

RESUMO

ABSTRACT. We demonstrate a 1050-nm spectral domain optical coherence tomography (OCT) system with a 12 mm imaging depth in air, a 120 kHz A-scan rate and a 10 µm axial resolution for anterior-segment imaging of human eye, in which a new prototype InGaAs linescan camera with 2048 active-pixel photodiodes is employed to record OCT spectral interferograms in parallel. Combined with the full-range complex technique, we show that the system delivers comparable imaging performance to that of a swept-source OCT with similar system specifications.


Assuntos
Segmento Anterior do Olho/anatomia & histologia , Técnicas de Diagnóstico Oftalmológico , Processamento de Imagem Assistida por Computador/métodos , Tomografia de Coerência Óptica/métodos , Segmento Anterior do Olho/química , Humanos
3.
Opt Lett ; 33(21): 2479-81, 2008 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-18978893

RESUMO

A high-speed (47,000 A-scans/s), ultrahigh axial resolution Fourier domain optical coherence tomography (OCT) system for retinal imaging at approximately 1060 nm, based on a 1024 pixel linear array, 47 kHz readout rate InGaAs camera is presented. When interfaced with a custom superluminescent diode (lambda(c) = 1020 nm, Deltalambda = 108 nm, Pout = 9 mW), the system provides 3.3 microm axial OCT resolution at the surface of biological tissue, approximately 4.5 microm in vivo in rat retina, approximately 5.7 microm in vivo in human retina, and 110 dB sensitivity for 870 microW incident power and 21 mus integration time. Retinal tomograms acquired in vivo from a human volunteer and a rat animal model show clear visualization of all intraretinal layer and increased penetration into the choroid.


Assuntos
Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Retina/citologia , Retinoscopia/métodos , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Tomografia de Coerência Óptica/métodos , Animais , Humanos , Ratos , Sensibilidade e Especificidade