1.
Phys Med ; 119: 103300, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38325222

RESUMO

PURPOSE: The aim of the present study, conducted by a working group of the Italian Association of Medical Physics (AIFM), was to define typical z-resolution values for different digital breast tomosynthesis (DBT) models to be used as a reference for quality control (QC). Currently, there are no typical values published in internationally agreed QC protocols. METHODS: To characterize the z-resolution of the DBT models, the full width at half maximum (FWHM) of the artifact spread function (ASF), a technical parameter that quantifies the signal intensity of a detail along reconstructed planes, was analyzed. Five different commercial phantoms, CIRS Model 011, CIRS Model 015, Modular DBT phantom, Pixmam 3-D, and Tomophan, were evaluated on reconstructed DBT images and 82 DBT systems (6 vendors, 9 models) in use at 39 centers in Italy were involved. RESULTS: The ASF was found to be dependent on the detail size, the DBT angular acquisition range, the reconstruction algorithm and applied image processing. In particular, a progressively greater signal spread was observed as the detail size increased and the acquisition angle decreased. However, a clear correlation between signal spread and angular range width was not observed due to the different signal reconstruction and image processing strategies implemented in the algorithms developed by the vendors studied. CONCLUSIONS: The analysis led to the identification of typical z-resolution values for different DBT model-phantom configurations that could be used as a reference during a QC program.


Assuntos
Processamento de Imagem Assistida por Computador , Mamografia , Mamografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Artefatos , Algoritmos
2.
Phys Med ; 33: 56-67, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28010921

RESUMO

The aim of this work was to evaluate how different acquisition geometries and reconstruction parameters affect the performance of four digital breast tomosynthesis (DBT) systems (Senographe Essential - GE, Mammomat Inspiration - Siemens, Selenia Dimensions - Hologic and Amulet Innovality - Fujifilm) on the basis of a physical characterization. Average Glandular Dose (AGD) and image quality parameters such as in-plane/in-depth resolution, signal difference to noise ratio (SDNR) and artefact spread function (ASF) were examined. Measured AGD values resulted below EUREF limits for 2D imaging. A large variability was recorded among the investigated systems: the mean dose ratio DBT/2D ranged between 1.1 and 1.9. In-plane resolution was in the range: 2.2mm-1-3.8mm-1 in chest wall-nipple direction. A worse resolution was found for all devices in tube travel direction. In-depth resolution improved with increasing scan angle but was also affected by the choice of reconstruction and post-processing algorithms. The highest z-resolution was provided by Siemens (50°, FWHM=2.3mm) followed by GE (25°, FWHM=2.8mm), while the Fujifilm HR showed the lowest one, despite its wide scan angle (40°, FWHM=4.1mm). The ASF was dependent on scan angle: smaller range systems showed wider ASF curves; however a clear relationship was not found between scan angle and ASF, due to the different post processing and reconstruction algorithms. SDNR analysis, performed on Fujifilm system, demonstrated that pixel binning improves detectability for a fixed dose/projection. In conclusion, we provide a performance comparison among four DBT systems under a clinical acquisition mode.


Assuntos
Mamografia/métodos , Doses de Radiação , Artefatos , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Controle de Qualidade , Razão Sinal-Ruído