Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Ophthalmic Physiol Opt ; 44(5): 894-909, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38708449

RESUMO

PURPOSE: To investigate whether there is a measurable change in meibomian gland morphological characteristics over the course of a day (12 h) and over a month. METHODS: The study enrolled 15 participants who attended a total of 11 study visits spanning a 5-week period. To assess diurnal changes in meibomian glands, seven visits were conducted on a single day, each 2 h apart. For monthly assessment, participants attended an additional visit at the same time of the day every week for three consecutive weeks. Meibography using the LipiView® II system was performed at each visit, and meibomian gland morphological parameters were calculated using custom semi-automated software. Specifically, six central glands were analysed for gland length ratio, gland width, gland area, gland intensity and gland tortuosity. RESULTS: The average meibomian gland morphological metrics did not exhibit significant changes during the course of a day or over a month. Nonetheless, certain individual gland metrics demonstrated notable variation over time, both diurnally and monthly. Specifically, meibomian gland length ratio, area, width and tortuosity exhibited significant changes both diurnally and monthly when assessed on a gland-by-gland basis. CONCLUSIONS: Meibomian glands demonstrated measurable structural change over short periods of time (hours and days). These results have implications for innovation in gland imaging and for developing precision monitoring of gland structure to assess meibomian gland health more accurately.


Assuntos
Glândulas Tarsais , Humanos , Glândulas Tarsais/diagnóstico por imagem , Glândulas Tarsais/anatomia & histologia , Projetos Piloto , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Idoso , Disfunção da Glândula Tarsal/diagnóstico , Disfunção da Glândula Tarsal/diagnóstico por imagem , Lágrimas/fisiologia , Ritmo Circadiano/fisiologia , Fatores de Tempo
3.
Ophthalmic Physiol Opt ; 44(4): 774-786, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38578134

RESUMO

PURPOSE: To investigate gaze and behavioural metrics at different viewing distances with multifocal contact lenses (MFCLs), single vision contact lenses (SVCLs) and progressive addition lenses (PALs). METHODS: Fifteen presbyopic contact lens wearers participated over five separate study visits. At each visit, participants were randomly assigned to wear one of five refractive corrections: habitual PAL spectacles, delefilcon A (Alcon Inc.) MFCLs and three separate pairs of delefilcon A single vision lenses worn as distance, intermediate and near corrections. Participants wore a Pupil Core headset to record eye and head movements while performing three visual tasks: reading, visual search and scene observation. Data were investigated using linear regression and post-hoc testing. Parameters of interest included gaze (fixation duration, head movement) and behavioural (reading speed, reading accuracy, visual search time) metrics. RESULTS: Reading speed in SVCLs was significantly faster than in MFCLs and PAL spectacles (F = 16.3, p < 0.0001). Refractive correction worn did not influence visual search times (F = 0.16, p = 0.85). Fixation duration was significantly affected by the type of visual task (F = 60.2, p < 0.001), and an interaction effect was observed between viewing distance and refractive correction (F = 4.3, p = 0.002). There was significantly more horizontal and vertical head movement (F = 3.2, p = 0.01 and F = 3.3, p = 0.01, respectively) during visual search tasks when wearing PAL spectacles compared to SVCLs or MFCLs. CONCLUSION: This work showed that the type of refractive correction affects behavioural metrics such as reading speed and gaze behaviour by affecting horizontal and vertical head movements. The findings of this study suggest that under certain conditions, wearers of MFCLs make fewer head movements compared to PAL spectacles. Gaze behaviour metrics offer a new approach to compare and understand contact lens and spectacle performance, with potential applications including peripheral optical designs for myopia management.


Assuntos
Lentes de Contato , Óculos , Fixação Ocular , Presbiopia , Leitura , Refração Ocular , Acuidade Visual , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimentos Oculares/fisiologia , Fixação Ocular/fisiologia , Movimentos da Cabeça/fisiologia , Presbiopia/fisiopatologia , Presbiopia/terapia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Estudos Cross-Over , Estudos Prospectivos
4.
Ophthalmic Physiol Opt ; 44(4): 704-717, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38546401

RESUMO

PURPOSE: To investigate differences in key clinical parameters between asymptomatic and highly symptomatic soft contact lens (CL) wearers after 14 h of wear. METHODS: In this pilot investigation, Phase 1 identified asymptomatic (CLDEQ-8 score ≤ 7) and highly symptomatic (CLDEQ-8 score ≥ 20) subjects after fitting with nelfilcon A CLs. Phase 2 investigated the following over a single nelfilcon A CL-wearing day (14 ± 2 h): blinking characteristics, tear meniscus height (TMH), non-invasive tear break-up time (NIBUT), tear film osmolarity and eyelid margin staining. Parameters for the two groups were compared using linear mixed models and post-hoc testing. The relationship between comfort scores and the clinical parameters was also investigated. RESULTS: Overall, 161 and 42 subjects were enrolled into Phase 1 and 2, respectively. Twenty-five asymptomatic and 17 symptomatic subjects completed Phase 2. Lower eyelid TMH was decreased after 14 h in symptomatic compared with asymptomatic subjects (least square mean [LSM] difference -0.04 mm, 95% CI: -0.07, -0.01). Osmolarity was lower in symptomatic than in asymptomatic subjects at fitting (LSM difference -9.89, 95% CI: -18.91, -0.86). Upper eyelid margin staining was greater after 14 h in symptomatic than in asymptomatic subjects (LSM difference 0.53, 95% CI: 0.01, 1.05) and greater after 14 h than baseline in the symptomatic group (LSM difference 0.61, 95% CI: 0.16, 1.07). There was a significant relationship between comfort and upper eyelid margin staining (r = -0.40, 95% CI: -0.63, -0.11) and blink rate (r = -0.31, 95% CI: -0.57, -0.003). CONCLUSION: The potential parameters most effective in differentiating asymptomatic from symptomatic wearers were upper eyelid margin staining and lower TMH. The parameter with the strongest relationship to comfort was upper eyelid margin staining, where higher comfort scores were associated with lower levels of staining.


Assuntos
Piscadela , Lentes de Contato Hidrofílicas , Lágrimas , Humanos , Lentes de Contato Hidrofílicas/efeitos adversos , Masculino , Feminino , Adulto , Lágrimas/metabolismo , Lágrimas/fisiologia , Projetos Piloto , Piscadela/fisiologia , Adulto Jovem , Concentração Osmolar , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/fisiopatologia , Pálpebras
5.
Cont Lens Anterior Eye ; 46(6): 102068, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37919220

RESUMO

PURPOSE: All neophyte contact lens wearers require training on how to handle contact lenses. Currently, almost no published information exists describing the most common approaches used by those involved in such training in soft contact lens wearers. This study aimed to gather information on the approaches taken by those conducting this training worldwide. METHODS: An online survey was created in English and translated to Spanish and distributed internationally via social media, conference attendees, and professional contacts. The anonymous survey included information on workplace setting of respondents, information about the typical approaches used for application and removal of soft contact lenses, length of the appointment, and success rate with their approach. Survey responses were received between May 2021 and April 2022. RESULTS: A total of 511 individuals completed the survey and responses were received from 31 countries with 48.7% from the UK. The most common approach taught for application was to have the patient hold the upper eyelashes (84.7%) and to hold the lower eyelid with the same hand as the lens (89.4%). Lenses were applied directly to the cornea by 57.7% of the respondents. The most common approach taught for lens removal was to drag the lens inferiorly from the cornea prior to removal (49.3%). Most respondents did not use videos to aid the teaching appointment (62.0%); however, they felt that their approach was successful in most cases (90). Application and removal training sessions lasted a median of 30 min and contact lenses were typically dispensed after the instructor witnessing successful application and removal three times. CONCLUSION: Various methods are adopted globally for training of application and removal of soft contact lenses, with many advising a patient-specific approach is required for success. The results of this survey provide novel insights into soft contact lens handling training in clinical practice.


Assuntos
Lentes de Contato Hidrofílicas , Humanos , Córnea , Pálpebras , Inquéritos e Questionários
6.
Ophthalmol Sci ; 3(4): 100334, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37920420

RESUMO

Purpose: To develop and evaluate a deep learning algorithm for Meibomian gland characteristics calculation. Design: Evaluation of diagnostic technology. Subjects: A total of 1616 meibography images of both the upper (697) and lower (919) eyelids from a total of 282 individuals. Methods: Images were collected using the LipiView II device. All the provided data were split into 3 sets: the training, validation, and test sets. Data partitions used proportions of 70/10/20% and included data from 2 optometry settings. Each set was separately partitioned with these proportions, resulting in a balanced distribution of data from both settings. The images were divided based on patient identifiers, such that all images collected for one participant could end up only in one set. The labeled images were used to train a deep learning model, which was subsequently used for Meibomian gland segmentation. The model was then applied to calculate individual Meibomian gland metrics. Interreader agreement and agreement between manual and automated methods for Meibomian gland segmentation were also carried out to assess the accuracy of the automated approach. Main Outcome Measures: Meibomian gland metrics, including length ratio, area, tortuosity, intensity, and width, were measured. Additionally, the performance of the automated algorithms was evaluated using the aggregated Jaccard index. Results: The proposed semantic segmentation-based approach achieved average aggregated Jaccard index of mean 0.4718 (95% confidence interval [CI], 0.4680-0.4771) for the 'gland' class and a mean of 0.8470 (95% CI, 0.8432-0.8508) for the 'eyelid' class. The result for object detection-based approach was a mean of 0.4476 (95% CI, 0.4426-0.4533). Both artificial intelligence-based algorithms underestimated area, length ratio, tortuosity, widthmean, widthmedian, width10th, and width90th. Meibomian gland intensity was overestimated by both algorithms compared with the manual approach. The object detection-based algorithm seems to be as reliable as the manual approach only for Meibomian gland width10th calculation. Conclusions: The proposed approach can successfully segment Meibomian glands; however, to overcome problems with gland overlap and lack of image sharpness, the proposed method requires further development. The study presents another approach to utilizing automated, artificial intelligence-based methods in Meibomian gland health assessment that may assist clinicians in the diagnosis, treatment, and management of Meibomian gland dysfunction. Financial Disclosures: The authors have no proprietary or commercial interest in any materials discussed in this article.

7.
Clin Exp Optom ; : 1-11, 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-37989323

RESUMO

CLINICAL RELEVANCE: Evaluating how Meibomian glands can change in appearance has the potential to advance the understanding of Meibomian gland health and may lead to enhanced diagnosis and therapy. BACKGROUND: This work aimed to investigate Meibomian gland appearance after therapeutic Meibomian gland expression. METHODS: Fifteen subjects attended three study visits over a two-week period. Meibography was performed before and after therapeutic Meibomian gland expression, the following day, and 2 weeks after expression. Six central glands were used to calculate Meibomian gland morphological parameters such as gland length ratio, gland width, gland area, gland tortuosity, and gland contrast. A custom semi-automated image analysis software was used to calculate Meibomian gland metrics. Furthermore, a high-resolution imaging system was developed to capture clear images of the Meibomian glands, free of any artefacts, which were used for precise calculations of Meibomian gland contrast. RESULTS: The expression procedure had a significant impact on Meibomian gland contrast and length ratio immediately afterwards. The least square mean difference (95% CI) from baseline for Michelson contrast was -0.006 (-0.010, -0.001) and -1.048 (-2.063, -0.033) for simple contrast. The least square mean ratio of the gland length ratio immediately after the expression to baseline was 0.758 (0.618, 0.931). CONCLUSIONS: Following therapeutic expression, Meibomian glands exhibit reduced brightness and length. However, within 24 h, they appear to recover and return to their baseline state, indicating a relatively short recovery time. This sheds light on whether meibography is solely focused on capturing gland structure or if it also captures acinar activity. The hyperreflective properties of lipids suggest that the decrease in contrast observed after expression could be attributed to a reduction in the visualisation of acini activity. A decrease in Meibomian gland length ratio implies that the loss of gland structure following treatment may be indicative of a temporary structural alteration.

8.
Cont Lens Anterior Eye ; 46(5): 101887, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37460374

RESUMO

PURPOSE: To determine clinical performance and the 'Willingness To Pay' for toric vs. spherical soft contact lenses in an astigmatic population. METHODS: In the clinical study, subjects with binocular low to moderate astigmatism (-0.75DC to -1.50DC) wore pairs of soft toric (Biofinity toric) and spherical (Biofinity) contact lenses in random sequence. Visual acuity (high and low contrast, monocular and binocular), subjective comfort and subjective vision were recorded. In the economics study, first subjects who had participated in the clinical study were presented with a series of randomised economic scenarios in order to determine their Willingness To Pay a premium (i.e. an increase) for toric lenses. Then, a similar set of scenarios were presented to a much larger group of online respondents and again, Willingness To Pay was established. RESULTS: For the four measures of visual acuity, the Biofinity toric lens out-performed the Biofinity spherical lens by 0.6 to 1.1 lines.. Subjective vision performance was statistically significantly better with the toric lens for the distance task only. Comfort scores were not significantly different. Similar findings for Willingness To Pay were established for the clinical subjects and for the online respondents. The Willingness To Pay premium (additional fee) for a monthly supply of toric lenses (over spherical lenses) was between £13 and £16, if a toric lens provides better vision and similar comfort, as shown in the clinical study. CONCLUSION: Consumers are willing to pay a monthly premium of around 50% to benefit from the typical experience of better vision and similar comfort for toric vs. spherical lenses. The level of additional cost for toric lenses compared to their spherical equivalents is less than this in the market, so eye care professionals should consider that toric lenses are delivering a greater clinical return than anticipated by wearers for the relatively small increase in price.


Assuntos
Astigmatismo , Lentes de Contato Hidrofílicas , Humanos , Acuidade Visual , Refração Ocular , Astigmatismo/terapia
9.
Transl Vis Sci Technol ; 12(2): 9, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36749580

RESUMO

Purpose: To develop and evaluate a custom imaging system to provide high-resolution, wide depth-of-field, reflection-free, multispectral infrared (IR) imaging of the Meibomian glands. Methods: Lower eyelids of 15 volunteers were everted to obtain multispectral images of the Meibomian glands with custom imaging setup. Photographs were captured at 10 different ISO settings (from underexposure to overexposure) and using nine IR imaging filters (ranging from 600 nm to 1000 nm in 50-nm steps). Meibomian gland contrast (simple and Michelson) was calculated for the images to choose an optimal wavelength for Meibomian gland imaging and to determine differences in contrast across individuals. Results: The overall linear regression model showed a significant effect of wavelength on Meibomian gland contrast (Simple contrast: F = 7.24, P < 0.0001; Michelson contrast: F = 7.19, P < 0.0001). There was a significant negative correlation between Meibomian gland contrast and Meibomian gland depth for 750-nm IR filter (ρs= -0.579; P = 0.026). Conclusions: Meibomian gland contrast varies across individuals and depends on Meibomian gland depth. IR filter of 750 nm is the optimal choice for Meibomian gland imaging because it provides images of greatest contrast. Translational Relevance: This study adds to our understanding of Meibomian gland imaging. It has successfully demonstrated that Meibomian glands that are deeper in the tarsal plate require longer wavelengths for imaging.


Assuntos
Glândulas Tarsais , Humanos , Glândulas Tarsais/diagnóstico por imagem
10.
Int J Mol Sci ; 23(17)2022 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-36077001

RESUMO

Meibomian gland orifices (MGOs) are located along the eyelid margin and secrete meibum into the tear film. The profile of resident innate immune cells (ICs) at this site is not well understood. The distribution and phenotype of resident ICs around MGOs in mice was investigated and herein defined as MGO-associated immune cells (MOICs). The effect of topical 0.1% benzalkonium chloride (BAK) on MOICs was also assessed. Eyelids from healthy CD11ceYFP and Cx3cr1gfp/gfp mice aged three or seven months were compared. ICs were identified as CD11c+, Cx3cr1+, and MHC-II+ using four-colour immunostaining and confocal microscopy. MOIC density was variable but clustered around MGOs. There were more CD11c+ MOICs in three-month-old compared with seven-month-old mice (three-month-old: 893 ± 449 cells/mm2 vs. seven-month-old: 593 ± 493 cells/mm2, p = 0.004). Along the eyelid margin, there was a decreasing gradient of CD11c+ MOIC density in three-month-old mice (nasal: 1003 ± 369 cells/mm2, vs. central: 946 ± 574 cells/mm2, vs. temporal: 731 ± 353 cells/mm2, p = 0.044). Cx3cr1-deficient mice had two-fold fewer MHC-II+ MOICs, suggesting a role for Cx3cr1 receptor signaling in meibomian gland surveillance. CD11c+ MOIC density was lower in BAK-exposed eyes compared to saline-treated controls, suggesting a change in homeostasis. This study provides novel insight into resident ICs located at MGOs, and their contribution to MG homeostasis.


Assuntos
Doenças Palpebrais , Glândulas Tarsais , Animais , Compostos de Benzalcônio/farmacologia , Camundongos , Fenótipo , Lágrimas
11.
Ocul Surf ; 25: 119-128, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35724917

RESUMO

Meibography is a visualisation technique that has been used for over 40 years. There have been significant improvements in image quality, examination technique and image interpretation over this period. Although meibography has received sporadic reviews in the past, an updated review is timely due to the rapid recent rise of relevant technology and advances in both image processing and artificial intelligence. The primary aim of this paper is to review recent research into Meibomian gland imaging and update the community about the most relevant technologies and approaches used in the field.


Assuntos
Síndromes do Olho Seco , Doenças Palpebrais , Inteligência Artificial , Síndromes do Olho Seco/diagnóstico , Doenças Palpebrais/diagnóstico , Humanos , Processamento de Imagem Assistida por Computador , Glândulas Tarsais/diagnóstico por imagem , Lágrimas
12.
Cont Lens Anterior Eye ; 45(4): 101469, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34034960

RESUMO

AIM: To determine if a gradual adaptation period is necessary for neophytes when fitted with modern hydrogel or silicone hydrogel reusable disposable contact lenses. METHOD: Across four sites, 74 neophytes (18-28 years) were randomly assigned to a reusable lens cleaned nightly with Opti-Free® Puremoist® multi-purpose contact lens solution: Proclear® (hydrogel) or Biofinity® (silicone hydrogel) and an adaptation schedule: fast (10 h wear from the first day) or gradual (4 h on the first day, increasing their wear time by 2 h on each subsequent day until they had reached 10 h). Masked investigators graded ocular surface physiology and non-invasive tear breakup time (NIBUT) and a range of comfort, vision and lens handling subjective ratings (0-100 visual analogue scales) were recorded at the baseline visit and after 10 h of lens wear, 4-6 days and 12-14 days after lens fitting. Subjective scores were also repeated after 7 days. RESULTS: There was no difference (p > 0.05) in ocular surface physiology or NIBUT between fast and gradual adaptation groups at any time point in either lens type with the exception of increased corneal staining (p = 0.019) in the silicone hydrogel fast adaptation group after 4-6 days, but was similar by 12-14 days. Subjective scores were also similar across the visits and lens types with the exception of 'lens awareness' (p = 0.019) which was less in the gradual versus the fast adaptation silicone hydrogel lens group at 12-14 days. CONCLUSION: There seems to be no clinical benefit for recommending a gradual adaptation period in new wearers fitted with modern soft reusable disposable contact lenses. The findings of this work add to a growing body of evidence suggesting that such advice is unnecessary in regular soft contact lens wear, which has important ramifications for the initial clinical management of these patients.


Assuntos
Lentes de Contato Hidrofílicas , Hidrogel de Polietilenoglicol-Dimetacrilato , Humanos , Hidrogéis , Satisfação do Paciente , Silicones
13.
Cont Lens Anterior Eye ; 45(5): 101516, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34607768

RESUMO

PURPOSE: To test the hypothesis that various subjective ocular and task-related parameters associated with wearing a face mask would be better in neophyte contact lens (CL) wear compared to habitual spectacle (Sp) wear. METHODS: Thirty participants were randomised to continue in Sp (n = 15) or wear somofilcon A daily disposable CL (n = 15) ('group'). A surgical face mask (Type II R) was worn for at least one hour per day on four or more days per week. After two weeks, participants completed the Quality of Life Impact of Refractive Correction Questionnaire (QIRC), a two-part face mask usability questionnaire and graded ocular-related symptoms using 0-100 visual analogue scales. RESULTS: There was no difference between groups for overall QIRC score but some individual question scores reflected better quality of life in the CL: 'outdoor activities', 'keep fit' and 'able to do things' (all p < 0.05). Differences in favour of the CL were seen for the following in the face mask usability questionnaire: 'breathing', 'heat', 'comfort on ears', 'overall comfort', 'walking', 'driving', 'reading', 'computer use', 'exercising' and 'socialising' (all p < 0.05). Significant differences were also seen for the 0-100 VAS symptoms probing vision quality in favour of the CL: glare, distance and near vision, fogging, restricted field of view and peripheral blur. CONCLUSION: This work supports anecdotal reports that CL are a better vision correction option than Sp when used in conjunction with a face mask. Participants reported a range of benefits to the CL/face mask combination for vision-related symptoms, breathing and heat-related symptoms and a number of day-to-day activities including walking, driving and exercising. All of the benefits relating to the CL are likely to result in improved adherence to face mask use. Overall, the findings of this work suggest that where possible, CL should be the preferred vision correction option for people using face masks.


Assuntos
Lentes de Contato Hidrofílicas , Lentes de Contato , Óculos , Humanos , Máscaras , Satisfação do Paciente , Qualidade de Vida , Acuidade Visual
14.
Cont Lens Anterior Eye ; 45(4): 101489, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34281726

RESUMO

PURPOSE: To investigate the ocular subclinical inflammatory response in two soft contact lens materials when used in combination with two different care systems ('solutions'). METHODS: Fifteen established soft contact lens wearers wore each of two lenses: Acuvue® 2 (CH) and Acuvue® Oasys® (SiH) or no lenses in random sequence for one week. Two care systems were used: a peroxide system: Oxysept 1 Step® (P) for the right lens and Opti-Free® Replenish® (MPS) for the left lens. After one week of lens/no lens wear, in vivo confocal microscopy (IVCM) of corneal and conjunctival regions was carried out. Density of presumed dendritic cells (DC) and 'white spots' (WS) were quantified. Impression cytology of the bulbar and upper eyelid margin conjunctivae was carried out and samples were analysed for CD45+, CD3+ and CD11c+ cells. RESULTS: The SiH + MPS combination showed a greater inflammatory response compared to SiH + P in seven out of 12 parameters investigated (p < 0.05). The remaining five were not statistically different between the two solutions. The converse was found for the CH lens, with four of the 12 parameters showing a greater response with the P solution compared to the MPS (p < 0.05). CONCLUSION: This study suggests that the SiH lens investigated demonstrated an upregulated response when used with a MPS compared to a P solution whereas the converse is true for the CH lens which showed a reduced response when used with a MPS compared to a P solution. This finding aids in the understanding of the biological underpinnings of manifest corneal inflammatory events during contact lens wear.


Assuntos
Lentes de Contato Hidrofílicas , Hidrogel de Polietilenoglicol-Dimetacrilato , Córnea , Humanos , Inflamação/etiologia , Visão Ocular
15.
Cont Lens Anterior Eye ; 44(2): 132-156, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33775375

RESUMO

A key element of contact lens practice involves clinical evaluation of anterior eye health, including the cornea and limbus, conjunctiva and sclera, eyelids and eyelashes, lacrimal system and tear film. This report reviews the fundamental anatomy and physiology of these structures, including the vascular supply, venous drainage, lymphatic drainage, sensory innervation, physiology and function. This is the foundation for considering the potential interactions with, and effects of, contact lens wear on the anterior eye. This information is not consistently published as academic research and this report provides a synthesis from all available sources. With respect to terminology, the report aims to promote the consistent use of nomenclature in the field, and generally adopts anatomical terms recommended by the Federative Committee for Anatomical Terminology. Techniques for the examination of the ocular surface are also discussed.


Assuntos
Lentes de Contato , Lágrimas , Túnica Conjuntiva , Córnea , Pálpebras , Humanos
16.
Cont Lens Anterior Eye ; 44(4): 101387, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33308907

RESUMO

PURPOSE: This work set out to investigate if there was an association between subjective comfort and both subjective and measured vision during the use of contemporary daily disposable soft toric contact lenses. METHODS: Thirty-eight habitual soft contact lens wearers wore each of three daily disposable toric lenses for one week in a prospective, crossover, randomised, single-masked study. The following clinical measures were recorded at dispensing and follow-up visits: biomicroscopy scores, lens fitting (including rotation and rotational stability), high and low contrast visual acuity, subjective vision quality and subjective ocular surface comfort. Subjective scores were collected using 0-10 numerical grading scales. Comfort scores were analysed using a linear regression model with age, sex, visit, phase of crossover ('phase'), lens type, lens rotation, lens rotational stability, visual acuity, cylinder power and subjective vision quality as factors of interest and then refined using backward stepwise regression. RESULTS: Thirty six participants (31.1 ± 13.5 years) completed the study. Comfort scores were found to be associated with subjective vision quality (F = 127.0 ; p < 0.0001), phase (F = 7.2; p = 0.001) and lens type (F = 4.9; p = 0.009). Greater comfort scores were observed with greater subjective vision quality scores. Visual acuity was not statistically significant in the model. CONCLUSION: This work suggests that symptoms of ocular discomfort may be more intense if there is also perceived visual compromise in daily disposable soft toric lenses. There was a stronger positive correlation between comfort and subjective vision quality compared with comfort and measured visual acuity.


Assuntos
Lentes de Contato Hidrofílicas , Satisfação do Paciente , Humanos , Estudos Prospectivos , Visão Ocular , Acuidade Visual
17.
Ophthalmic Physiol Opt ; 40(4): 519-528, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32452570

RESUMO

PURPOSE: Development and validation of a non-invasive imaging system to capture spontaneous blinking and characterise blink dynamics using a custom image analysis algorithm. METHODS: A pilot study investigated the influence of illumination type on blink dynamics. Spontaneous blinking was recorded in eight subjects using a high-speed camera under two illumination conditions: white light and infrared. Custom semi-automated software assessed palpebral aperture height (PAH), blink rate, blink speed, blink completeness and blink duration. The main clinical study compared two different image analysis techniques. Spontaneous blinking was recorded in 20 subjects using a high-speed infrared camera. Blink speed and duration were determined using two techniques: manual tracking and semi-automated tracking. Agreement between the two techniques was assessed using Bland-Altman analysis. Coefficients of repeatability (COR) were calculated for the semi-automated technique. RESULTS: There were significant differences between white light and infrared illumination for PAH (p < 0.0001), blink rate (p = 0.04), closing speed (p = 0.009), opening speed (p < 0.0001) and blink duration (p = 0.0003). The mean differences (95% limits of agreement) between the two techniques were 0.6 mm s-1 (-15.9 to 17.0) closing speed, 1.5 mm s-1 (-6.8 to 9.8) opening speed, 2.4 ms (-6.8 to 11.5) closed phase duration and 5.0 ms (-19.4 to 29.3) total blink duration. COR values were 10.1 mm s-1 closing speed, 3.7 mm s-1 opening speed, 6.7 ms closed phase duration and 11.2 ms total blink duration. CONCLUSIONS: This study has shown that spontaneous blinking can be characterised using a non-invasive imaging system. The semi-automated analysis provides a rapid characterisation of blink dynamics, allowing its application in large-scale trials in a number of clinical areas.


Assuntos
Piscadela/fisiologia , Diagnóstico por Imagem/métodos , Pálpebras/fisiologia , Processamento de Imagem Assistida por Computador/instrumentação , Software , Adulto , Feminino , Humanos , Masculino , Projetos Piloto , Gravação em Vídeo
18.
Cont Lens Anterior Eye ; 43(5): 476-483, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32151528

RESUMO

PURPOSE: To investigate ocular discomfort during contact lens wear using a wrist-mounted electronic 'lens awareness logger' (LAL). METHODS: Thirty symptomatic contact lens wearers wore study contact lenses for three days. On the first two days, two lens types which are known to differ in end-of-day comfort (lens A: senofilcon A and lens B: balafilcon A), were worn as a matching pair (randomised order). On day three, a pair of lens B was worn. On each day, the participant used a LAL. On day one and two, the participant pressed a button on the LAL whenever they became aware of their lenses due to discomfort. On day three, the participant used a multiple click protocol (1 = mild awareness to 3 = severe awareness) to report discomfort. RESULTS: LAL events were similar on days one and two (17.3 vs. 15.8 events per day). There were significantly more LAL events for lens B (21.6 events per day) in comparison with lens A (11.6 events per day) (p = 0.006). The LAL event profile highlighted peaks in awareness following lens application and towards the end of the wearing cycle. Comparison of the LAL event profile for the two lens types showed significant differences in lens awareness, particularly in the first half of the wearing cycle. LAL events on day 3, showed a uniform distribution of single and double clicks through the day, but a marked peak in triple clicks in the last two hours of lens wear. CONCLUSION: The LAL was able to differentiate between the study lenses and demonstrated differences in their LAL event profiles. Lens awareness associated with discomfort appeared to increase not only in frequency, but also in intensity towards the end of the wearing cycle. The ability of the LAL to track lens awareness suggests it is likely to be a useful tool in furthering understanding of ocular discomfort.


Assuntos
Lentes de Contato Hidrofílicas , Lentes de Contato , Lentes de Contato Hidrofílicas/efeitos adversos , Eletrônica , Olho , Humanos , Satisfação do Paciente , Visão Ocular , Punho
19.
Cont Lens Anterior Eye ; 43(3): 268-273, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31543407

RESUMO

PURPOSE: Despite the widespread practice of gradually adapting all new soft contact lens wearers (neophytes), there is little evidence-based research underpinning such practice. This work determined if a gradual adaptation period is necessary for neophytes when fitted with modern hydrogel or silicone-hydrogel daily disposable contact lenses. METHOD: At four sites, neophytes (19-32 years) were randomly assigned to an adaptation schedule: fast (10 h wear from the first day) or gradual (4 h on the first day, increasing their wear-time by 2 h on each subsequent day until they had reached 10 h) with hydrogel (n = 24 fast; n = 21 gradual) or silicone-hydrogel (n = 10 fast; n = 10 gradual) contact lenses. Masked investigators graded ocular surface physiology and non-invasive tear breakup time (NIBUT). A range of subjective scores (using 0-100 visual analogue scales) were recorded at the initial visit and after 10 h of lens wear, 4-6 days and 12-14 days after initial fitting. Subjective scores were also repeated after 7 days. RESULTS: There was no difference (p > 0.05) in ocular surface physiology between the fast and gradual adaptation groups at any time point in either lens type. NIBUT was similar at all time points for both adaptation groups in both lens types with the exception that the gradual adaptation silicone-hydrogel wearers had a slightly longer NIBUT (p = 0.007) than the fast adaptation group at 12-14 days. Subjective scores were also similar across the visits and lens types with the exception of 'lens awareness' and 'ease of lens removal' which were better (p < 0.05) in the fast compared with the gradual adaptation hydrogel lens group at day 7. Additionally, 'end-of-day discomfort' was better (p = 0.02) in the fast compared with the gradual adaptation hydrogel lens group at 12-14 days. CONCLUSION: There appears to be no benefit in daily disposable soft contact lens adaptation for neophytes with modern contact lens materials.


Assuntos
Adaptação Ocular/fisiologia , Lentes de Contato de Uso Prolongado , Córnea/fisiopatologia , Satisfação do Paciente , Erros de Refração/terapia , Lágrimas/metabolismo , Adulto , Córnea/metabolismo , Equipamentos Descartáveis , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Erros de Refração/metabolismo , Erros de Refração/fisiopatologia , Método Simples-Cego , Adulto Jovem
20.
Cont Lens Anterior Eye ; 43(4): 378-388, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31451311

RESUMO

PURPOSE: Fluorescein-labelled wheat germ agglutinin (F-WGA) acts as a marker for ocular surface mucins. This clinical study sought to investigate whether the degree of F-WGA fluorescence observed at the ocular surface differed between symptomatic contact lens wearers, asymptomatic contact lens wearers and non-contact lens wearers, using a novel imaging system. METHODS: Twenty-five participants (10 symptomatic contact lens wearers, 10 asymptomatic contact lens wearers and 5 non-contact lens wearers) attended a single study visit. Photographs of the cornea, bulbar and tarsal conjunctiva were captured following application of F-WGA solution. RESULTS: The imaging system captured high-resolution images of F-WGA fluorescence at the ocular surface. The degree of fluorescence differed between the ocular surface regions (p < 0.001). A significant difference in fluorescence was observed between participant groups for the cornea (p = 0.01), with both the symptomatic and asymptomatic contact lens wearers showing lower fluorescence than the non-lens wearers. F-WGA associated fluorescence appeared diminished in the lid wiper region of the symptomatic lens wearers, compared to the asymptomatic group (p = 0.025). CONCLUSION: The use of F-WGA as a clinical marker for ocular surface mucins allows an improved understanding of their distribution across the ocular surface. Contact lens wear appears to negatively impact mucin density across the ocular surface, with the most marked effect on the cornea. F-WGA fluorescence appeared diminished in the lid wiper region for the symptomatic contact lens wearing group, indicating that mechanical interaction in this region may play a role in the aetiology of contact lens discomfort. Given the ability of F-WGA to disclose mucin distribution across the ocular surface it is likely to be a key clinical tool in furthering our understanding of (i) the aetiology of contact lens related discomfort, (ii) contact lens designs/materials to minimise interaction with the ocular surface and (iii) dry eye disease and other ocular surface diseases.


Assuntos
Lentes de Contato Hidrofílicas , Síndromes do Olho Seco , Túnica Conjuntiva , Humanos , Mucinas , Imagem Óptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...