1.
Audiol Res ; 14(3): 401-411, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38804458

RESUMO

Despite the spread of novel-generation cochlear-implant (CI) magnetic systems, access to magnetic resonance imaging (MRI) for CI recipients is still limited due to safety concerns. The aim of this study is to assess and record the experiences of Hires Ultra 3D (Advanced Bionics) recipients who underwent an MRI examination. A multicentric European survey about this topic was conducted focusing on safety issues, and the results were compared with the current literature. We collected a total of 65 MRI scans performed in 9 otologic referral centers for a total of 47 Hires Ultra 3D recipients, including, for the first time, 2 children and 3 teenagers. Preventive measures were represented by scanning time and sedation for children. Head wrapping was used in eight cases, and six of the eight cases received local anesthesia, even if both measures were not needed. Only three patients complained of pain (3/65 examinations, 4.6%) due to the tight head bandage, and one of the three cases required MRI scan interruption. No other adverse events were reported. We believe that these results should encourage MRI execution in accordance with manufacturer recommendations for Ultra 3D recipients.

2.
J Funct Biomater ; 14(12)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38132815

RESUMO

Ossiculoplasty is a surgical operation performed to restore auditory transmission through the reconstruction of the ossicular chain using prosthetics. Tissue bioengineering has assumed a pivotal role in implementing alternatives to conventional ossicular middle ear replacement prostheses, to overcome extrusion while preserving acoustic properties. This in vitro study aims to explore, for the first time in current literature, the feasibility of a biohybrid middle ear prosthesis, composed of titanium surrounded by a bone extracellular matrix as bio-coating. We have hereby studied the adhesion and proliferation of human adipose-derived mesenchymal stem cells (hASC) on titanium scaffolds in vitro. Moreover, we identified the osteogenic differentiation of hASC using an immunofluorescence assay to analyze osteoblasts' gene expression profiles (Alp, Runx2, Col1a1, Osx, and Bglap), and we counted the presence of collagen as a marker of hASC's ability to secrete an extracellular matrix. We utilized scanning electron microscopy to evaluate the presence of an extracellular matrix on the scaffolds. Our preliminary data demonstrated the titanium's ability to support human adipose-derived mesenchymal stem cell colonization, proliferation, and osteoblastic differentiation, in order to obtain a biohybrid device. Our experience seems encouraging; thus, we advocate for further in vivo research to corroborate our results regarding bone transplantation.

3.
Acta Otorhinolaryngol Ital ; 43(Suppl. 1): S67-S75, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37698103

RESUMO

Objective: To establish the safety and effectiveness of subtotal petrosectomy with cochlear implantation in patients affected by chronic middle ear disorders to refractory to previous surgical treatments. Methods: A multicentre, retrospective study was conducted on patients affected by recalcitrant chronic middle ear disorders who underwent cochlear implantation in combination with subtotal petrosectomy. Patients' details were collected from databases of 11 Italian tertiary referral centres. Additionally, a review of the most updated literature was carried out. Results: 55 patients were included with a mean follow-up time of 44 months. Cholesteatoma was the most common middle ear recurrent pathology and 50.9% of patients had an open cavity. 80% of patients underwent a single stage surgery. One case of explantation for device failure was reported among the 7 patients with post-operative complications. Conclusions: Subtotal petrosectomy with cochlear implantation is a benchmark for management of patients with recalcitrant chronic middle ear disorders. A single stage procedure is the most recommended strategy. Optimal follow-up is still debated. Further studies are required to investigate the role of this surgery in paediatric patients.


Assuntos
Colesteatoma , Implante Coclear , Otite Média Supurativa , Humanos , Orelha Média/cirurgia , Estudos Retrospectivos
4.
Acta Otorhinolaryngol Ital ; 43(4): 273-282, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37488991

RESUMO

Objective: To assess artifact size and MRI visibility when applying the "Orthopedic-Metal Artifact Reduction" (O-MAR) algorithm for cochlear implant (CI) scanning. Methods: Two volunteers were submitted to 1.5 T MRI with an Ultra 3D CI receiver stimulator placed on their head. Four angular CI orientations were adopted: 90, 120, 135 and 160 degrees. Volunteers were scanned in each condition using T1w and T2w TSE sequences, as well as O-MAR sequences, in both axial and coronal planes. Quantitative comparisons were made of signal void and penumbra extent. Additionally, qualitative evaluations of global image quality, MRI readability with respect to 12 anatomical structures and visibility through the penumbra were undertaken. Results: After application of the O-MAR protocol, the radius of the signal void reduced from 50.76 mm to 45.43 mm and from 49.22 mm to 40.15 mm on T1w and T2w TSE axial sequences, respectively (p < 0.05). Qualitatively, sequences acquired with O-MAR produced better outcomes in terms of image quality and anatomical depiction. Despite the area of the penumbra being increased for the O-MAR protocol, visibility through penumbra was improved. Conclusions: Application of O-MAR may provide a complementary strategy to those already in use to obtain diagnostically useful MRI examinations in the presence of a CI, especially in case of skull base diseases requiring MRI monitoring.


Assuntos
Implantes Cocleares , Tomografia Computadorizada por Raios X , Humanos , Algoritmos , Artefatos , Base do Crânio/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética
5.
Acta Otorhinolaryngol Ital ; 41(1): 91-99, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33746228

RESUMO

INTRODUCTION: The retrosigmoidal (RS) placement of the Bonebridge system (BB) has been advocated for cases of unfavourable anatomical or clinical conditions which contraindicate transmastoid-presigmoidal positioning. However, these disadvantageous conditions, combined with the considerable dimensions of the implant, may represent a challenge, especially for surgeons with no skull base experience. Moreover, the literature reports only limited experience concerning RS implantation of the BB system. METHODS: A multicentre, retrospective study was conducted to analyse the surgical and functional outcomes of a wide population of patients undergoing RS placement of the BB system by means of a surgical technique specifically developed to overcome the intraoperative issues related to this surgery. Twenty patients with conductive or mixed hearing loss and single sided deafness were submitted to RS implantation of the BB system. RESULTS: Audiological assessment concerning the measurement of the functional and effective gain by pure-tone audiometry (28 dB HL and -12.25 dB HL, respectively) and speech audiometry (24.7 dB HL and -21 dB HL, respectively) was conducted. A high overall subjective improvement of quality of life was recorded with the Glasgow Benefit Inventory questionnaire. No major complications, such as device extrusions or other conditions requiring revision surgery, were reported during the follow-up period (median: 42 months). CONCLUSIONS: In our study, which has one of the largest cohort of patients reported in the literature, RS placement of the BB system was safe and effective. Our functional results showed comparable hearing outcomes with presigmoidal placement. The effective gain, rarely investigated in this field, may be the object of further research to improve our understanding of bone conduction mechanisms exploited by bone conduction hearing implants.


Assuntos
Condução Óssea , Auxiliares de Audição , Percepção da Fala , Adulto , Idoso , Audiometria de Tons Puros , Feminino , Perda Auditiva Condutiva , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...