Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Oncol ; 14(1): 172, 2019 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-31533746

RESUMO

BACKGROUND: Vendor-independent Monte Carlo (MC) dose calculation (IDC) for patient-specific quality assurance of multi-leaf collimator (MLC) based CyberKnife treatments is used to benchmark and validate the commercial MC dose calculation engine for MLC based treatments built into the CyberKnife treatment planning system (Precision MC). METHODS: The benchmark included dose profiles in water in 15 mm depth and depth dose curves of rectangular MLC shaped fields ranging from 7.6 mm × 7.7 mm to 115.0 mm × 100.1 mm, which were compared between IDC, Precision MC and measurements in terms of dose difference and distance to agreement. Dose distributions of three phantom cases and seven clinical lung cases were calculated using both IDC and Precision MC. The lung PTVs ranged from 14 cm3 to 93 cm3. Quantitative comparison of these dose distributions was performed using dose-volume parameters and 3D gamma analysis with 2% global dose difference and 1 mm distance criteria and a global 10% dose threshold. Time to calculate dose distributions was recorded and efficiency was assessed. RESULTS: Absolute dose profiles in 15 mm depth in water showed agreement between Precision MC and IDC within 3.1% or 1 mm. Depth dose curves agreed within 2.3% / 1 mm. For the phantom and clinical lung cases, mean PTV doses differed from - 1.0 to + 2.3% between IDC and Precision MC and gamma passing rates were > =98.1% for all multiple beam treatment plans. For the lung cases, lung V20 agreed within ±1.5%. Calculation times ranged from 2.2 min (for 39 cm3 PTV at 1.0 × 1.0 × 2.5 mm3 native CT resolution) to 8.1 min (93 cm3 at 1.1 × 1.1 × 1.0 mm3), at 2% uncertainty for Precision MC for the 7 examined lung cases and 4-6 h for IDC, which, however, is not optimized for efficiency but used as a gold standard for accuracy. CONCLUSIONS: Both accuracy and efficiency of Precision MC in the context of MLC based planning for the CyberKnife M6 system were benchmarked against MC based IDC framework. Precision MC is used in clinical practice at our institute.


Assuntos
Algoritmos , Neoplasias Pulmonares/cirurgia , Método de Monte Carlo , Imagens de Fantasmas , Neoplasias da Próstata/cirurgia , Radiocirurgia/instrumentação , Radiocirurgia/métodos , Benchmarking , Humanos , Neoplasias Pulmonares/patologia , Masculino , Órgãos em Risco/efeitos da radiação , Prognóstico , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
2.
Phys Med Biol ; 63(1): 015015, 2017 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-29256450

RESUMO

This work aims to develop, implement and validate a Monte Carlo (MC)-based independent dose calculation (IDC) framework to perform patient-specific quality assurance (QA) for multi-leaf collimator (MLC)-based CyberKnife® (Accuray Inc., Sunnyvale, CA) treatment plans. The IDC framework uses an XML-format treatment plan as exported from the treatment planning system (TPS) and DICOM format patient CT data, an MC beam model using phase spaces, CyberKnife MLC beam modifier transport using the EGS++ class library, a beam sampling and coordinate transformation engine and dose scoring using DOSXYZnrc. The framework is validated against dose profiles and depth dose curves of single beams with varying field sizes in a water tank in units of cGy/Monitor Unit and against a 2D dose distribution of a full prostate treatment plan measured with Gafchromic EBT3 (Ashland Advanced Materials, Bridgewater, NJ) film in a homogeneous water-equivalent slab phantom. The film measurement is compared to IDC results by gamma analysis using 2% (global)/2 mm criteria. Further, the dose distribution of the clinical treatment plan in the patient CT is compared to TPS calculation by gamma analysis using the same criteria. Dose profiles from IDC calculation in a homogeneous water phantom agree within 2.3% of the global max dose or 1 mm distance to agreement to measurements for all except the smallest field size. Comparing the film measurement to calculated dose, 99.9% of all voxels pass gamma analysis, comparing dose calculated by the IDC framework to TPS calculated dose for the clinical prostate plan shows 99.0% passing rate. IDC calculated dose is found to be up to 5.6% lower than dose calculated by the TPS in this case near metal fiducial markers. An MC-based modular IDC framework was successfully developed, implemented and validated against measurements and is now available to perform patient-specific QA by IDC.


Assuntos
Método de Monte Carlo , Neoplasias/cirurgia , Imagens de Fantasmas , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Humanos , Radiometria , Dosagem Radioterapêutica
3.
Strahlenther Onkol ; 189(9): 765-70, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23934329

RESUMO

BACKGROUND: Tumor bed stereotactic radiosurgery (SRS) after resection of brain metastases is a new strategy to delay or avoid whole-brain irradiation (WBRT) and its associated toxicities. This retrospective study analyzes results of frameless image-guided linear accelerator (LINAC)-based SRS and stereotactic hypofractionated radiotherapy (SHRT) as adjuvant treatment without WBRT. MATERIALS AND METHODS: Between March 2009 and February 2012, 44 resection cavities in 42 patients were treated with SRS (23 cavities) or SHRT (21 cavities). All treatments were delivered using a stereotactic LINAC. All cavities were expanded by ≥ 2 mm in all directions to create the clinical target volume (CTV). RESULTS: The median planning target volume (PTV) for SRS was 11.1 cm(3). The median dose prescribed to the PTV margin for SRS was 17 Gy. Median PTV for SHRT was 22.3 cm(3). The fractionation schemes applied were: 4 fractions of 6 Gy (5 patients), 6 fractions of 4 Gy (6 patients) and 10 fractions of 4 Gy (10 patients). Median follow-up was 9.6 months. Local control (LC) rates after 6 and 12 months were 91 and 77 %, respectively. No statistically significant differences in LC rates between SRS and SHRT treatments were observed. Distant brain control (DBC) rates at 6 and 12 months were 61 and 33 %, respectively. Overall survival (OS) at 6 and 12 months was 87 and 63.5 %, respectively, with a median OS of 15.9 months. One patient treated by SRS showed symptoms of radionecrosis, which was confirmed histologically. CONCLUSION: Frameless image-guided LINAC-based adjuvant SRS and SHRT are effective and well tolerated local treatment strategies after resection of brain metastases in patients with oligometastatic disease.


Assuntos
Lesões Encefálicas/epidemiologia , Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/cirurgia , Lesões por Radiação/epidemiologia , Radiocirurgia/mortalidade , Radioterapia Adjuvante/mortalidade , Radioterapia Guiada por Imagem/mortalidade , Adulto , Idoso , Neoplasias Encefálicas/mortalidade , Fracionamento da Dose de Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida , Suíça/epidemiologia , Resultado do Tratamento
4.
Biochemistry ; 26(18): 5826-33, 1987 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-3676294

RESUMO

Deuterium nuclear magnetic resonance was used to investigate the structure of different lipid fractions isolated from the anaerobic bacteria Clostridium butyricum and Clostridium beijerinckii. The fractions isolated from C. butyricum were (1) phosphatidylethanolamine/plasmenylethanolamine and (2) the glycerol acetal of plasmenylethanolamine, and from C. beijerinckii similar fractions containing principally (1) phosphatidyl-N-monomethylethanolamine, along with its plasmalogen, and (2) the glycerol acetal of this plasmalogen were isolated. The third fraction from both species consisted largely of the acidic lipids phosphatidylglycerol and cardiolipin along with plasmalogen forms of these lipids. Palmitic acid with deuterium labels at C-2, C-3, or C-4 or oleic acid with deuterium labels at C-2 and C-9,10 was added to the growth medium and incorporated to various extents in the lipid fractions. Biochemical analysis showed that palmitic acid and oleic acid were preferentially bound to the sn-2 and sn-1 positions, respectively, of the glycerol backbone when both fatty acids were added to the medium. From the 2H NMR spectra, the hydrocarbon chain ordering near the lipid-water interface could be determined and appeared to be similar for all three lipid fractions. The deuterium quadrupole splitting and order parameter were low at the C-2 segment and increased by almost a factor of 2 at positions C-3 and C-4 for cells fed with deuterated palmitic acid along with unlabeled oleic acid. These results agree with previous findings on pure diacyl lipids in which the sn-2 chain was found to adopt a bent conformation at the carbon segment C-2. However, two unusual quadrupole splittings could be detected for the plasmalogens.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Clostridium/análise , Plasmalogênios/isolamento & purificação , Acetais , Acilação , Alquilação , Deutério , Glicerol , Espectroscopia de Ressonância Magnética/métodos , Especificidade da Espécie
5.
Biochim Biophys Acta ; 900(2): 191-7, 1987 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-3593714

RESUMO

Deuterium nuclear magnetic resonance (2H-NMR) was used to investigate the structure and dynamics of the sn-2 hydrocarbon chain of semi-synthetical choline and ethanolamine plasmalogen in bilayers containing 0, 30, and 50 mol% cholesterol. The deuterium NMR spectra of the choline plasmalogen yielded well-resolved quadrupolar splittings which could be assigned to the corresponding hydrocarbon chain deuterons. The sn-2 acyl chain was found to adopt a similar conformation as observed in the corresponding diacyl phospholipid, however, the flexibility at the level of the C-2 methylene segment of the plasmalogen was increased. Deuterium NMR spectra of bilayers composed of the ethanolamine plasmalogen yielded quadrupolar splittings of the C-2 segment much larger than those of the corresponding diacyl lipids, suggesting that the sn-2 chain is oriented perpendicular to the membrane surface at all segments. Cholesterol increased the ordering of the choline plasmalogen acyl chain to the same extent as in diacyl lipid bilayers. T1 relaxation time measurements demonstrated only minor dynamical differences between choline plasmalogen and diacyl lipids in model membranes.


Assuntos
Colesterol , Bicamadas Lipídicas , Modelos Biológicos , Plasmalogênios , Espectroscopia de Ressonância Magnética/métodos , Conformação Molecular , Relação Estrutura-Atividade
6.
Biochim Biophys Acta ; 899(2): 302-6, 1987 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-3580370

RESUMO

Palmitic acid specifically deuterated at different carbon atoms, has been incorporated biosynthetically into the membrane lipids of Clostridium butyricum. The lipids of this organism are rich in plasmalogens and their glycerol acetals and exhibit an unusual fatty acyl and alkenyl chain distribution with saturated chains mainly at the sn-2 position and unsaturated chains at the sn-1 position. The ordering of the deuterated hydrocarbon chains in whole cells was measured with deuterium nuclear magnetic resonance and was compared to the order profiles of isolated cell membranes and membranes formed from the total phospholipid extract. The shape of the order profiles was similar for all three membranes, but the absolute values of the order profiles in whole cells and isolated membranes were lower than those of the liposomal lipids. The order profiles have the same characteristic shape as those found for the lamellar liquid-crystalline phases of synthetic diacylphospholipids.


Assuntos
Clostridium/análise , Lipídeos de Membrana/análise , Plasmalogênios/análise , Membrana Celular/análise , Deutério , Ácidos Graxos/análise , Espectroscopia de Ressonância Magnética/métodos , Fosfolipídeos/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...