Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pharmaceuticals (Basel) ; 17(3)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38543176

RESUMO

The radionuclides 43Sc, 44g/mSc, and 47Sc can be produced cost-effectively in sufficient yield for medical research and applications by irradiating natTi and natV target materials with protons. Maximizing the production yield of the therapeutic 47Sc in the highest cross section energy range of 24-70 MeV results in the co-production of long-lived, high-γ-ray-energy 46Sc and 48Sc contaminants if one does not use enriched target materials. Mass separation can be used to obtain high molar activity and isotopically pure Sc radionuclides from natural target materials; however, suitable operational conditions to obtain relevant activity released from irradiated natTi and natV have not yet been established at CERN-MEDICIS and ISOLDE. The objective of this work was to develop target units for the production, release, and purification of Sc radionuclides by mass separation as well as to investigate target materials for the mass separation that are compatible with high-yield Sc radionuclide production in the 9-70 MeV proton energy range. In this study, the in-target production yield obtained at MEDICIS with 1.4 GeV protons is compared with the production yield that can be reached with commercially available cyclotrons. The thick-target materials were irradiated at MEDICIS and comprised of metallic natTi, natV metallic foils, and natTiC pellets. The produced radionuclides were subsequently released, ionized, and extracted from various target and ion source units and mass separated. Mono-atomic Sc laser and molecule ionization with forced-electron-beam-induced arc-discharge ion sources were investigated. Sc radionuclide production in thick natTi and natV targets at MEDICIS is equivalent to low- to medium-energy cyclotron-irradiated targets at medically relevant yields, furthermore benefiting from the mass separation possibility. A two-step laser resonance ionization scheme was used to obtain mono-atomic Sc ion beams. Sc radionuclide release from irradiated target units most effectively could be promoted by volatile scandium fluoride formation. Thus, isotopically pure 44g/mSc, 46Sc, and 47Sc were obtained as mono-atomic and molecular ScF 2+ ion beams and collected for the first time at CERN-MEDICIS. Among all the investigated target materials, natTiC is the most suitable target material for Sc mass separation as molecular halide beams, due to high possible operating temperatures and sustained release.

2.
EJNMMI Radiopharm Chem ; 8(1): 27, 2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37823964

RESUMO

BACKGROUND: In order to support the ongoing research across Europe to facilitate access to novel radionuclides, the PRISMAP consortium (European medical radionuclides programme) was established to offer the broadest catalog of non-conventional radionuclides for medical and translational research. The aim of this article is to introduce readers with current status of novel radionuclides in Europe. MAIN BODY: A consortium questionnaire was disseminated through the PRISMAP consortium and user community, professional associations and preclinical/clinical end users in Europe and the current status of clinical end-users in nuclear medicine were identified. A total of 40 preclinical/clinical users institutions took part in the survey. Clinical end users currently use the following radionuclides in their studies: 177Lu, 68 Ga, 111In, 90Y, other alpha emitters, 225Ac, 64Cu and Terbium isotopes. Radionuclides that would be of interest for users within the next 2-5 years are 64Cu, Terbium radionuclide "family" and alpha emitters, such as 225Ac. CONCLUSIONS: Thanks to a questionnaire distributed by the PRISMAP consortium, the current status and needs of clinical end-users in nuclear medicine were identified.

3.
Diagnostics (Basel) ; 12(12)2022 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-36553183

RESUMO

BACKGROUND: Early diagnosis of recurrent prostate cancer is a cornerstone for further adequate therapy planning. Therefore, clinical practice and research still focuses on diagnostic tools that can detect prostate cancer in early recurrence when it is undetectable in conventional diagnostic imaging. 18F-PSMA-1007 PET/CT is a novel method to evaluate patients with biochemical recurrent PCa. The aim of this review was to evaluate the role of 18F-PSMA-1007 PET/CT in prostate cancer local recurrence, lymph node metastases and bone metastases detection. METHODS: Original studies, reviews and five meta-analyses were included in this article. A total of 70 studies were retrieved, 31 were included in the study. RESULTS: All patients described in the studies underwent 18F-PSMA-1007 PET/CT. The administered 18F-PSMA-1007 individual dose ranged from 159 ± 31 MBq to 363.93 ± 69.40 MBq. Results showed that 18F-PSMA-1007 PET/CT demonstrates a good detection rate in recurrent prostate cancer. CONCLUSIONS: 18F-PSMA-1007 PET/CT appears to achieve reliable performance in detecting recurrent prostate cancer. The high detection rate of 18F-PSMA-1007 PET/CT in recurrent prostate cancer was confirmed, especially in local recurrence and small lymph nodes with non-specific characteristics on conventional diagnostic imaging methods. However, several authors emphasize some limitations for this tracer-for example, non-specific uptake in bone lesions that can mimic bone metastases.

4.
Am J Nucl Med Mol Imaging ; 11(5): 395-405, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34754610

RESUMO

The aim of this study was to compare the diagnostic tools-18F-PSMA-1007 positron emission tomography (PET/CT), magnetic resonance imaging (MRI) and bone scintigraphy for the evaluation of local recurrence, regional lymph nodes and bone metastases of recurrent prostate cancer (PCa). 28 PCa patients after radical prostatectomy and/or radiation therapy and with biochemical relapse were enrolled in this study. The evaluation of local recurrence and regional lymph node metastases was based on results of PET/CT and MRI. Local recurrent disease in 28 patients was detected by PET/CT in 36% (10/28) and by MRI in 32% (9/28) with sensitivity, specificity, accuracy of 90.9%, 100%, 96.4% and 81.8%, 100%, 92.9%, respectively (kappa 0.92, P<0.001). Nodal involvement was confirmed by PET/CT and MRI in 46% (13/28) and 25% (7/28) with sensitivity, specificity and accuracy for PET/CT 92.3%, 93.3%, 92.9% and for MRI-53.8%, 100%, 78.6%, respectively (kappa 0.57, P<0.001). The evaluation of skeletal metastases was based on PET/CT and bone scintigraphy. Bone metastases were seen on PET/CT and bone scintigraphy in 21% (6/28) and 20% (5/25) with sensitivity, specificity and accuracy of 100%; 91.7%; 92.9% and 50.0%; 85.7%; 80.0%, respectively (kappa 0.41, P<0.01). In conclusion, our comparative study demonstrates advantages of 18F-PSMA-1007 PET/CT compared to MRI and scintigraphy for the evaluation of recurrent prostate cancer. Both methods, 18F-PSMA-1007 PET/CT and MRI, detect local recurrence with high accuracy and excellent agreement, which may be attributed to the low urinary background clearance of 18F-PSMA-1007.

5.
Am J Nucl Med Mol Imaging ; 10(2): 106-118, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32419979

RESUMO

Anatomical and functional imaging plays a decisive role for detection and staging, of prostate cancer both primarily and post-treatment. While multiparametric MRI offers anatomic imaging with excellent soft tissue contrast, hybrid imaging based on positron emission tomography in combination with computed tomography (PET/CT) contributes functional imaging capacities. Since 68Ga-PSMA-11 was expected to be more efficient than the prior Choline-based PET radiotracers, it was the aim of the study to evaluate the diagnostic performance of the 68Ga-PSMA-11 PET/CT and multiparametric MRI in patients with recurrent prostate cancer and low PSA levels. 32 out of a cohort of 128 prostate cancer patients with biochemical relapse were referred for 68Ga-PSMA-11 PET/CT, MRI and bone scintigraphy. According to the histopathologically or clinically defined reference standard all results were classified as true positive, false positive, true negative or false negative. Local recurrence was present in 11/32 patients, lymph node metastases - in 13/32 patients and, bone metastases - in 6/32 patients. Against the standard of reference, sensitivity, specificity and accuracy for local recurrence of PET/CT were 63.6 %; 73.7%; 77.8%, respectively. MRI reached 90.9%; 94.7%; 92.3%, respectively. For local lymph node metastases PET/CT - 83.3%; 80.0% and 90.6%, respectively. MRI - 41.7%; 94.4%; 72.0%, respectively. For evaluation of bone metastases in PET/CT - 83.3%; 92.0%; 71.0%, respectively. Bone scintigraphy - 50.0%; 84.0%; 77.4%, respectively. In conclusion, mpMRI offered the better diagnostic accuracy in the detection of local recurrence and while PSMA PET/CT was superior in the detection of distant and lymph node metastases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...