Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Curr Res Transl Med ; 66(1): 1-7, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29487039

RESUMO

BACKGROUND: The zinc transporter 8 (ZnT8) is an islet ß-cell secretory granule membrane protein coded by the SLC30A8 gene, identified as a novel autoantigen in human type 1 diabetes (T1D). As no data of ZnT8ab in Algerian patients have been reported, we aim to evaluate the prevalence of ZnT8ab in young Algerians with T1D and determine whether ZnT8ab could be a better diagnostic tool to replace the other conventional autoantibodies detected in patients with type 1 diabetes. For this purpose, we evaluated the prevalence of islets cells antibodies (ICA), glutamic acid decarboxylase (GAD), islet antigen type 2 (IA2), insulin (IA) autoantibodies (ab) and for the first time in Algeria, the zinc transporter 8 (ZnT8) in young Algerian patients with type 1 diabetes. PATIENTS AND METHODS: In our cross-sectional study, 160 patients between 1 and 35 years old, diagnosed with type 1 diabetes were enrolled. ICAab was analyzed by indirect immunofluorescence (IIF), GADab, IA2ab, IAab and ZnT8ab were analyzed by ELISA, fasting blood glucose was performed by enzymatic method (glucose-oxidase) and HbA1c by turbid metric method. RESULTS: Our cohort was composed with 74 males and 86 females (OR=1.16); the mean of age was 14.09 [1-35] years old and the median diabetes duration was 4.10 [1-18] years. Our cohort had a mean of HbA1c of 9.22 [5.40-15]%, the mean of birth weight was 3360.52 [2200-4800]g; the mean of BMI was 19.30 [16.04-22.46]kg/m2. Out of 160 patients, 44 (27.5%) were under mother breastfeeding and 116/160 (72.5%) were under artificial feeding. One antibody, at least, was found in 94.38% and the ZnT8ab was significantly more positive in females (70.3%) than in males (10.7%) (***P=8.033×10-15). The concentration of ZnT8ab was higher in females than in males (females=122.25UI/mL versus males=51.38UI/mL; *P=0.03); ICAab, GADab and ZnT8ab were more present in patients with consanguineous parents (***P=0.0002, *P=0.019 and *P=0.03; respectively) CONCLUSION: Our study on ZnT8ab in T1D is the first in the Maghreb region and we observed a prevalence of 46.25%. The positivity of ZnT8ab enabled us to classify in T1DA 50% of diabetics with obvious T1D phenotype and negative routine autoantibodies, thus ZnT8ab is a good tool for differential diagnosis of type 1 diabetes. According to our results, a simultaneous analysis for ZnT8 and IA2 autoantibodies can be a better and efficient diagnosis of type 1A diabetes from the beginning of the disease.


Assuntos
Autoanticorpos/sangue , Diabetes Mellitus Tipo 1/diagnóstico , Glutamato Descarboxilase/imunologia , Anticorpos Anti-Insulina/sangue , Transportador 8 de Zinco/imunologia , Adolescente , Adulto , Argélia/epidemiologia , Autoanticorpos/análise , Biomarcadores/análise , Biomarcadores/sangue , Criança , Pré-Escolar , Estudos Transversais , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/epidemiologia , Diabetes Mellitus Tipo 1/imunologia , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Lactente , Anticorpos Anti-Insulina/análise , Masculino , Valor Preditivo dos Testes , Proteínas Tirosina Fosfatases Classe 8 Semelhantes a Receptores/imunologia , Sensibilidade e Especificidade , Estudos Soroepidemiológicos , Adulto Jovem
2.
Arch Inst Pasteur Alger ; 57: 151-62, 1989.
Artigo em Francês | MEDLINE | ID: mdl-2489398

RESUMO

The Coomassie blue method of proteins quantitation initially reported by Bradford and modified by Macart et al. appears to be simple, fast, sensitive and of low cost. In this study, we report an improved micromethod derived from the technic described by Macart. Applied to the protein quantitation of 100 cerebrospinal fluid (CSF) specimens and 50 serum specimens our method showed a very good correlation with the macromethod of Macart (r = 0.985 for CSF proteins, r = 0.944 for serum proteins) and also with the Lowry technic (r = 0.986 for CSF proteins, r = 0.898 for serum proteins). Our technic may be used with various biological fluids (urines, tears, saliva...) and seems to be of particular interest for low protein level fluids and for little volume samples (it needs only 20 mcl).


Assuntos
Proteínas/análise , Corantes de Rosanilina , Líquidos Corporais/química , Colorimetria , Humanos , Microquímica , Doenças do Sistema Nervoso/sangue , Doenças do Sistema Nervoso/líquido cefalorraquidiano
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...