Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Sci ; 39(5): 671-677, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36637706

RESUMO

Radioactive isotope (RI) metals are a new type of tracer for positron emission tomography generated from the target metal by proton irradiation using a cyclotron. The generated metal RIs need to be separated from the target metal rapidly and effectively. In the present study, we developed a 3D-printed flow device to separate metal RIs from target metals. The separation was performed with selective formation of ethylenediaminetetraacetic acid (EDTA) complex based on the difference in formation constants. The RI metal selectively formed a EDTA complex, thus changing its ionic charge in solution. The solution was then introduced into a cation exchange column for selective adsorption of the target metal. The solution with added chelator and controlled pH was introduced into the developed system and automatically separated metal RI from target metals within 14 min. The separation method was applied to separate RI 67Ga from target metal Zn using a mixture of 107 pg L-1 67Ga in 250 mg L-1 Zn2+. The recoveries of 67Ga and Zn were 97% and 100%, respectively. Furthermore, an ultraviolet (UV) radiation reactor was integrated into the system to decompose the EDTA complex and recover the Ga3+ ion. Ga3+ recovery by UV radiation was effective, 87%. The developed system was also successfully applied to the separation of Zr and Y. Therefore, the method and system can be applied to separate other metal RIs from target metals.

2.
ACS Omega ; 7(18): 15779-15785, 2022 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-35571765

RESUMO

Preparing compounds containing the radioisotope 64Cu for use in positron emission tomography cancer diagnostics is an ongoing area of research. In this study, a highly efficient separation method to recover 64Cu generated by irradiating the target 64Ni with a proton beam was developed by employing a flow electrolysis cell (FE). This system consists of (1) applying a reduction potential for the selective adsorption of 64Cu from the target solution when dissolved in HCl and (2) recovering the 64Cu deposited onto the carbon working electrode by desorbing it from the FE during elution with 10 mmol/L HNO3, which applies an oxidation potential. The 64Cu was selectively eluted at approximately 30 min under a flow rate of 0.5 mL/min from the injection to recovery. The newly developed flow electrolysis system can separate the femtomolar level of ultratrace radioisotopes from the larger amount of target metals as an alternative to conventional column chromatography.

3.
Anal Chem ; 93(51): 17069-17075, 2021 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-34910462

RESUMO

Short-lived radioactive metals are important tracers in clinical diagnosis. Radioactive metals for clinical use are produced from suitable target metals in cyclotrons. The trace amount of radioactive metal produced is contained in a relatively large amount of target metal. A rapid and effective method is required to isolate the radioactive metal. In the present study, selective complex formation followed by cation-exchange adsorption was performed in a continuous flow-based system. Ethylenediamine-N,N,N',N'-tetraacetic acid (EDTA) was selected as the ligand after simulation of the separation of radioactive Ga from the target (Zn). Selectively, the Ga-EDTA complex passed through the cation trap, while Zn2+ was trapped. This separation principle is opposite to that of typical solid-phase extraction, which captures the target ion. The proposed separation was performed in a flow-based system with a parallel, open-channel ion trap. The performance was optimized by altering the channel dimensions, channel-filling mesh, and flow rate. Finally, the target radioactive metal, Ga, was selectively and effectively (>99%) separated from a mixture of 50 fg Ga/L and 100 mg Zn/L. The concentration of Zn remaining in the Ga solution was 2.3 µg/L. The complexed Ga was converted to free Ga3+ by a simple UV irradiation method. The proposed method effectively and rapidly separates trace amounts of radioactive metals contained in larger amounts of target metals using a simple flow system that can be operated on site.


Assuntos
Ciclotrons , Metais , Indicadores e Reagentes , Extração em Fase Sólida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...