Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Clin Anat ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747093

RESUMO

The two most common techniques to determine femoral tunnel placement during medial patellofemoral ligament (MPFL) reconstruction are radiographic and by palpation. Their intra/interobserver reliability is widely debated. Both techniques rely on identifying bony landmarks such as the medial epicondyle (ME) and adductor tubercle (AT) during surgery. During MPFL reconstructive surgery, the central longitudinal vessels (CLVs) are seen consistently. The aim of this study was to investigate the anatomic relationship of CLV to ME and AT and to determine if CLV might be used as a landmark during MPFL reconstruction. A retrospective review of MRI scans in skeletally mature patients was undertake. There were two groups, a PFI group that consisted of patients with a diagnosis of patellofemoral instabiliy (PFI) and a non-PFI group that underwent MRI scan for an alternative diagnosis. MRIs were measured for the CLV-ME-AT anatomy and relationship. Following exclusions, 50 patients were identified in each group. The CLV passed anterior to the AT and ME in all patients. ME morphology did not differ greatly between the groups except in the tubercle height, where there was statistically significant but not a clinically important difference (larger in the non-PFI group, 2.95 vs. 2.52 mm, p = 0.002). The CLV to ME tip distance was consistent between the groups (PFI group 3.8 mm and non-PFI group 3.9 mm). The CLV-ME-AT relationship remained consistent irrespective of patients' presenting pathology. The CLV consistently courses anterior to ME and AT. The CLV could be used as a vascular landmark assisting femoral tunnel placement during MPFL reconstruction.

2.
Clin Biomech (Bristol, Avon) ; 110: 106125, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37922607

RESUMO

BACKGROUND: High tibial osteotomy surgery is a widely successful joint-preserving procedure which alters the hip-knee-ankle axis which can delay the progression of osteoarthritis; however, conventional osteotomy surgical procedures do not adequately control the posterior tibial slope. This study aimed to determine the key variables influencing posterior tibial slope during high tibial osteotomy and provide a simple means of implementing the findings during pre-operative planning. METHODS: A virtual cohort of twenty-eight proximal tibia geometries of knee osteoarthritis patients was used in the study. Firstly, absolute posterior tibial slope values were contrasted using anatomical and posterior mechanical axis measurement approaches. Secondly, the influence of variables affecting posterior tibial slope change during osteotomy surgery was investigated using 3D preoperative planning surgical simulation and analytical modelling. FINDINGS: There was a poor correlation (R2 = 0.38) between the different clinical measurements of posterior tibial slope; with an average of 7.0 ± 1.3° and 14.8 ± 2.2° respectively. An analytical solution for the change in posterior tibial slope was derived based on the hinge axis angle and the osteotomy opening angle. For three different opening angles (6°, 9° and 12°) and seven different hinge axis orientations (-30° to +30°), the results obtained were identical for the analytical model and the 3D preoperative planning. INTERPRETATION: This study determined that the key variables affecting posterior tibial slope during high tibial osteotomy are the osteotomy opening angle and the hinge axis orientation. The derived formula provides a simple means of determining the change in posterior tibial slope resulting from a particular surgical approach.


Assuntos
Osteoartrite do Joelho , Tíbia , Humanos , Tíbia/cirurgia , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Joelho , Osteotomia/métodos
3.
J Orthop ; 46: 156-160, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37997600

RESUMO

Patellofemoral (PFJ) arthritis can be primary, or secondary to underlying trochlea dysplasia and patellofemoral malalignment. Although primary PFJ osteoarthritis affects an older patient population, just like tibiofemoral arthritis, it is common for younger patients to present with isolated PFJ arthritis secondary to an abnormal PFJ. PFJ arthroplasty (PFJA) has many benefits including being less invasive, associated with lower blood loss, is more cost-effective, and leaves the kinematics of the tibiofemoral joint undisturbed. As a result, there are arguably better functional outcomes associated with PFJA, however the historical revision rate of this procedure is high. Although registry outcome data associated with the first generation of PFJ implants shows a higher revision rate compared to TKA, the comparison of PFJ outcomes with TKA is not always age-matched and there is limited comparison on functional and patient-reported outcomes, something which is more important and relevant in a younger patient cohort. Improvements in implant design, instrumentation, surgical technique, and better patient selection has now resulted in outcomes which are comparable to that of TKA, and in some cases even better. This narrative review outlines the current outcomes of PFJA including highlighting factors which need to be considered in optimising outcomes, as well as discussing advanced techniques of robotic assisted PFJA.

4.
Indian J Orthop ; 57(9): 1376-1386, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37609016

RESUMO

Background: While the literature suggests a correlation between posterior tibial slope and sagittal stability of the knee, there is a lack of consensus relating to how to measure the slope, what a normal slope value would be, and which critical values should guide extra surgical treatment. We performed a systematic literature review looking at the posterior tibial slope and cruciate ligament surgery. Our aims were to define a gold standard measurement technique of posterior tibial slope, as well as determining its normal range and the important values for consideration of adjuncts during cruciate ligament surgery. Methods: Electronic searches of MEDLINE (PubMed), CINAHL, Cochrane, Embase, ScienceDirect, and NICE in June 2020 were completed. Inclusion criteria were original studies in peer-reviewed English language journals. A quality assessment of included studies was completed using the Methodological Index for Non-Randomized Studies (MINORS) Criteria. Results: Two-hundred and twenty-one papers were identified; following exclusions 34 papers were included for data collection. The mean MINORS score was 13.8 for non-comparative studies and 20.4 for comparative studies, both indicating fair to good quality studies. A large variation in the posterior tibial slope measurement technique was identified, resulting in a wide range of values reported. A significant variation in slope value also existed between different races, ages and genders. Conclusion: Cautiously, the authors suggest a normal range of 6-12º, using the proximal tibial axis at 5 and 15 cms below the joint. We suggest 12º as a cut-off value for slope-reducing osteotomy as an adjunct to revision ligament reconstruction.

5.
J Med Econ ; 26(1): 537-546, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36974460

RESUMO

AIMS: For patients with cartilage defects of the knee, a new biocompatible and in situ cross-linkable albumin-hyaluronan-based hydrogel has been developed for matrix-associated autologous chondrocyte implantation (M-ACI) - NOVOCART Inject plus (Ninject; TETEC AG, Reutlingen, Germany). We aimed to estimate the potential cost-effectiveness of NInject, that is not available on the market, yet compared to spheroids of human autologous matrix-associated chondrocytes (Spherox; CO.DON GmbH, Leipzig, Germany) and microfracture. MATERIALS AND METHODS: An early Markov model was developed to estimate the cost-effectiveness in the United Kingdom (UK) from the payer perspective. Transition probabilities, response rates, utility values and costs were derived from literature. Since NInject has not yet been launched and no prices are available, its costs were assumed equal to those of Spherox. Cycle length was set at one year and the time horizon chosen was notional patients' remaining lifetime. Model robustness was evaluated with deterministic and probabilistic sensitivity analyses (DSA; PSA) and value of information analysis (VOIA). The Markov model was built using TreeAge Pro Healthcare. RESULTS: NInject was cost-effective compared to microfracture (ICER: £5,147) while Spherox was extendedly dominated. In sensitivity analyses, the ICER exceeded conventional WTP threshold of £20,000 only when the utility value after successful first treatment with NInject was decreased by 20% (ICER: £69,620). PSA corroborated the cost-effectiveness findings of NInject, compared to both alternatives, with probabilities of 60% of NInject undercutting the aforementioned WTP threshold and being the most cost-effective alternative. The VOIA revealed that obtaining additional evidence on the new technology will likely not be cost-effective for the UK National Health Service. LIMITATIONS AND CONCLUSION: This early Markov model showed that NInject is cost-effective for the treatment of articular cartilage defects in the knee, compared to Spherox and microfracture. However, as the final price of NInject has yet to be determined, the cost-effectiveness analysis performed in this study is provisional, assuming equal prices for NInject and Spherox.


Assuntos
Cartilagem Articular , Fraturas de Estresse , Masculino , Humanos , Análise Custo-Benefício , Medicina Estatal , Antígeno Prostático Específico , Condrócitos
6.
Arch Orthop Trauma Surg ; 143(4): 2141-2151, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35690965

RESUMO

INTRODUCTION: Alignment goals in total knee replacement (TKR) is a topical subject. This study compares the short-term functional outcomes and patient reported outcome measures (PROMs) of two philosophies for knee arthroplasty alignment: measured resection (MR) and an individualised alignment philosophy, with the tibia mechanically aligned and an instrumented gap balancer (GB) to align the femur in both flexion and extension. PATIENTS AND METHODS: 94 knees were enrolled in this randomised controlled trial. The surgical protocol used a MR technique for mechanical alignment or a GB technique for individualised alignment. Primary outcome was quadriceps strength. Secondary outcomes included validated functional tests and PROMs as well as patient satisfaction. Outcomes were assessed pre-operatively, at 6 weeks, 3, 6 and 12 months post-operatively. RESULTS: At 12-month follow-up, there was no significant difference in the change from baseline mean quadriceps peak torque between the two groups (p = 0.988). Significant improvement in the change in range of motion (ROM) in the GB group compared to the MR group at 3 months (13° vs 6° p = 0.028) but this improvement was not significant at 1 year (20° vs 17° p = 0.21). The functional test of balance showed statistically significant improvement at 6 weeks (p = 0.03) in the GB group but this difference was not maintained. PROMs favoured the GB group, with the KOOS pain scoring statistically better (p ≤ 0.05) at 6 weeks, 3, 6 and 12 months. CONCLUSIONS: Individualised alignment philosophy utilising a GB technique did not demonstrate an improvement in the primary outcome measure quadriceps peak torque. Improvement was seen in the GB group in PROM pain scores that was significant, both statistically and clinically, out to at least 1 year. Gains that were seen in functional assessment with GB, although significant at some time points, were no longer significant at 1 year and no difference was seen in quads strength. Compared to a MR technique, the individualised GB technique appears to confer some improvement in pain, ROM and some functional tests following TKR in the short-term.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Articulação do Joelho/cirurgia , Artroplastia do Joelho/métodos , Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular
7.
Knee ; 40: 201-219, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36512892

RESUMO

BACKGROUND (INCLUDING AIMS OF THE STUDY): To investigate the impact medial opening wedge high tibial osteotomy (MOWHTO) has on the progression of patellofemoral (PF) OA, patella height, contact pressure within the PF joint and clinical outcomes. METHODS: A systematic review was conducted in January 2022 according to PRISMA guidelines. The ICRS cartilage grade of the PF joint at the initial MOWHTO surgery and at second look surgery was compared and relative risk of progression of PF OA was calculated. Evaluation of patella height was assessed by Caton-Deschamps index, Blackburne-Peel index or Insall-Salvati index pre and post MOWHTO. Cadaveric studies assessing contact pressures in the PF after MOWHTO were included. RESULTS: Forty-two studies comparing 2419 patients were included. The mean age was 53.1 years (16-84), 61.3% female. The risk of progression of PF OA was highest in the uniplanar and biplanar MOWHTO with proximal tubercle osteotomy groups (RR = 1.28-1.51) compared to biplanar MOHWTO with distal tubercle osteotomy (RR = 0.96-1.04). Patella height was not affected after biplanar MOWHTO with distal tubercle osteotomy (p < 0.001). Cadaveric studies demonstrate that PF contact pressures increase with more severe corrections (15°) but suggest biplanar MWOHTO and distal tubercle osteotomy induces lower contact pressures within the PF joint than other MOWHTO techniques. Significant over correction is associated with worse clinical outcomes and anterior knee pain. CONCLUSION: Biplanar MOWHTO and distal tubercle osteotomy has minimal effect on the contact pressures in the PF joint resulting in less severe progression of PF OA and has minimal impact on patella height.


Assuntos
Osteoartrite do Joelho , Articulação Patelofemoral , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Osteoartrite do Joelho/cirurgia , Articulação Patelofemoral/cirurgia , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Osteotomia/efeitos adversos , Osteotomia/métodos , Patela/cirurgia , Cadáver , Estudos Retrospectivos
8.
Musculoskeletal Care ; 21(2): 434-443, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36398738

RESUMO

BACKGROUND: Physiotherapists are often key decision-makers on when to refer patients with recurrent patellar dislocation for surgical opinion. Limited guidance exists to aid this decision. Differences in orthopaedic surgeons' and physiotherapists' views on which patients and when to refer people for surgical consideration or non-operative care may affect outcome. This study aimed to explore orthopaedic surgeons and physiotherapists decision-making surrounding treatment opinions for patients with recurrent patellar dislocation. METHODS: An online survey performed. UK registered and practicing orthopaedic surgeons and physiotherapists were invited to participate. The survey utilised two vignettes and a series of related questions to ascertain respondents' views on decision-making to surgical referral for people with recurrent patellar dislocation. Data were analysed using descriptive statistics and inferential statistical tests to explore factors related to responses. RESULTS: Eighty four respondent surveys were analysed (38 surgeons, 46 physiotherapists). Overall, there was a low level of agreement amongst respondents for the management of the vignettes (k = 0.215, p = < 0.0005). Some disparity existed between the professions on the definition of recurrent patellar dislocations and the clinical features which may require an early surgical assessment. Physiotherapists were three times more likely to delay a surgical opinion for the vignettes presented in this study than the surgeons. CONCLUSION: This is the first study to investigate orthopaedic surgeons' and physiotherapists' views on decision-making around surgical or non-operative management for recurrent patellar dislocations. High-quality research is required to underpin explicit guidance on decision-making regarding management of recurrent patellar dislocation.


Assuntos
Instabilidade Articular , Luxação Patelar , Fisioterapeutas , Cirurgiões , Humanos , Luxação Patelar/cirurgia , Inquéritos e Questionários , Reino Unido
9.
Indian J Orthop ; 56(12): 2110-2118, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36507211

RESUMO

In this article we wish to provide MAKO robotic knee users a surgical guide including tips and tricks on performing MAKO robotic-assisted patellofemoral joint replacements. The senior authors in this paper from the Exeter Knee Reconstruction Unit, United Kingdom are highly experienced MAKO users who have been performing MAKO assisted Patellofemoral joint replacements since 2017.

10.
Bone Jt Open ; 3(3): 268-274, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35321559

RESUMO

Recognized anatomic variations that lead to patella instability include patella alta and trochlea dysplasia. Lateralization of the extensor mechanism relative to the trochlea is often considered to be a contributing factor; however, controversy remains as to the degree this contributes to instability and how this should be measured. As the tibial tuberosity-trochlear groove (TT-TG) is one of most common imaging measurements to assess lateralization of the extensor mechanism, it is important to understand its strengths and weaknesses. Care needs to be taken while interpreting the TT-TG value as it is affected by many factors. Medializing tibial tubercle osteotomy is sometimes used to correct the TT-TG, but may not truly address the underlying anatomical problem. This review set out to determine whether the TT-TG distance sufficiently summarizes the pathoanatomy, and if this assists with planning of surgery in patellar instability. Cite this article: Bone Jt Open 2022;3(3):268-274.

11.
J Knee Surg ; 35(8): 838-843, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33231282

RESUMO

Patella alta is a common and significant abnormality responsible for many patellofemoral joint-related conditions. Many methods of patella height measurements are described; however, patellotrochear index (PTI) is the most logical method as it measures the direct relation between patella and trochlea. The aim of this study is to investigate PTI in normal healthy asymptomatic volunteers to understand the patellofemoral relation in normal knees. Twenty-five healthy volunteers underwent magnetic resonance imaging (MRI) scans of both knees. Two observers independently measured PTI on two different occasions at 6-week interval. Statistical analysis was performed to identify intra- and interobserver correlation between two observers and the mean value of PTI. Agreement analysis was performed according to Bland and Altman. Comparisons of means were made using paired t-tests. The mean age of 25 healthy volunteers was 21.28 years (19-23) with a male:female ratio of 14:11. The overall mean PTI value of all observations was 36.8% and pooled standard deviation (SD) 11.5%. Intraclass correlation (ICC) testing showed "good" interobserver ICC between two observers for PTI for both first (0.80) and second (0.84) set of measurements. There was "excellent" intraobserver correlation for two sets of measurements of PTI made by each first (0.96) and second (0.91) observer. Intraobserver repeatability for PTI was ± 0.07 and ± 0.1, respectively, for the first and second observer. Interobserver repeatability for PTI was ± 0.159 and ± 0.133, respectively, for the first and second set of measurements. Analysis of individual measurements of patella and trochlear articular cartilage revealed that the largest repeatability values were for trochlea measurements. The study reports that the average PTI in asymptomatic healthy knee utilizing current clinical MRI scanning conditions is 36.8%. This provides surgeons with a gold standard normal PTI value, which can serve as a target value in clinical diagnosis as well as surgical correction of patella height. There is good to excellent intra- and interobserver correlation with limited variability in assessing patella height using PTI on MRI scan.


Assuntos
Cartilagem Articular , Articulação Patelofemoral , Adulto , Cartilagem Articular/diagnóstico por imagem , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Patela/diagnóstico por imagem , Articulação Patelofemoral/diagnóstico por imagem , Reprodutibilidade dos Testes
12.
J Knee Surg ; 35(7): 731-738, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33126284

RESUMO

Patello-femoral arthroplasty (PFA) is successful in a selected group of patients and yields a good functional outcome. Robotic-assisted knee arthroplasty has been shown to provide better implant positioning and alignment. We aim to report our early outcomes and to compare Mako's (Robotic Arm Interactive Orthopaedic System [RIO]) preoperative implant planning position to our intraoperative PFA implant position. Data for this study was prospectively collected for 23 (two bilateral) patients who underwent robotic-assisted PFA between April 2017 and May 2018. All preoperative implant position planning and postoperative actual implant position were recorded. Presence of trochlear dysplasia and functional outcome scores were also collected. There were 17 (two bilateral) female and 6 male patients with a mean age of 66.5 (range: 41-89) years. The mean follow-up period was 30 (range: 24-37) months. Eighteen knees (72%) had evidence of trochlear dysplasia. The anterior trochlear line was on average, 7.71 (range: 3.3-11.3) degrees, internally rotated to the surgical transepicondylar axis and on average 2.9 (range: 0.2-6.5) degrees internally rotated to the posterior condylar line. The preoperative planning range was 4-degree internal to 4-degree external rotation, 4-degree varus to 6-degree valgus, and 7-degree flexion to 3-degree extension. The average difference between preoperative planning and intraoperative implant position was 0.43 degrees for rotation (r = 0.93), 0.99 degrees for varus/valgus (r = 0.29), 1.26 degrees for flexion/extension (r = 0.83), and 0.34 mm for proudness (r = 0.80). Six patients (24%) had a different size component from their preoperative plan (r = 0.98). The mean preoperative Oxford Knee Score (OKS) was 16 and the mean postoperative OKS was 42. No patient had implant-related revision surgery or any radiological evidence of implant loosening at final follow-up. Our early results of robotic PFA are promising. Preoperative Mako planning correlates closely with intraoperative implant positioning. Longer follow-up is needed to assess long-term patient outcomes and implant survivorship.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Idoso , Artroplastia do Joelho/efeitos adversos , Feminino , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Masculino , Osteoartrite do Joelho/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos
13.
Knee ; 33: 73-83, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34562741

RESUMO

BACKGROUND: There are significant deficiencies in the evidence base of modern-day osteotomy which result in significant variation in practice between surgeons. The purpose of this statement was to develop a consensus statement on the practice of osteotomy so that a more standardized approach to the indications, surgical technique, and postoperative care could be outlined. The article is also intended to educate and inform the practice of individuals who are early in their experience and/or clinical practice. METHOD: A group of 29 specialist knee surgeons who regularly perform osteotomy was convened to form the Knee Osteotomy consensus Group (KOG). Consensus was determined utilizing the consensus group technique described by List. A total of 37 questions were asked covering all aspects of clinical practice. RESULTS: 20 statements were generated and debated until a criterion level of 70% was met. CONCLUSIONS: Consensus was achieved regarding 20 statements concerning Indications for surgery, decision making, surgical planning, technique, post-operative assessment and recovery.


Assuntos
Osteotomia , Tíbia , Consenso , Humanos , Articulação do Joelho/cirurgia , Reino Unido
14.
Commun Med (Lond) ; 1: 6, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35602226

RESUMO

Background: Despite favourable outcomes relatively few surgeons offer high tibial osteotomy (HTO) as a treatment option for early knee osteoarthritis, mainly due to the difficulty of achieving planned correction and reported soft tissue irritation around the plate used to stablise the osteotomy. To compare the mechanical safety of a new personalised 3D printed high tibial osteotomy (HTO) device, created to overcome these issues, with an existing generic device, a case-control in silico virtual clinical trial was conducted. Methods: Twenty-eight knee osteoarthritis patients underwent computed tomography (CT) scanning to create a virtual cohort; the cohort was duplicated to form two arms, Generic and Personalised, on which virtual HTO was performed. Finite element analysis was performed to calculate the stresses in the plates arising from simulated physiological activities at three healing stages. The odds ratio indicative of the relative risk of fatigue failure of the HTO plates between the personalised and generic arms was obtained from a multi-level logistic model. Results: Here we show, at 12 weeks post-surgery, the odds ratio indicative of the relative risk of fatigue failure was 0.14 (95%CI 0.01 to 2.73, p = 0.20). Conclusions: This novel (to the best of our knowledge) in silico trial, comparing the mechanical safety of a new personalised 3D printed high tibial osteotomy device with an existing generic device, shows that there is no increased risk of failure for the new personalised design compared to the existing generic commonly used device. Personalised high tibial osteotomy can overcome the main technical barriers for this type of surgery, our findings support the case for using this technology for treating early knee osteoarthritis.

15.
Commun Med (Lond) ; 1(1): 6, 2021 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-36737534

RESUMO

BACKGROUND: Despite favourable outcomes relatively few surgeons offer high tibial osteotomy (HTO) as a treatment option for early knee osteoarthritis, mainly due to the difficulty of achieving planned correction and reported soft tissue irritation around the plate used to stablise the osteotomy. To compare the mechanical safety of a new personalised 3D printed high tibial osteotomy (HTO) device, created to overcome these issues, with an existing generic device, a case-control in silico virtual clinical trial was conducted. METHODS: Twenty-eight knee osteoarthritis patients underwent computed tomography (CT) scanning to create a virtual cohort; the cohort was duplicated to form two arms, Generic and Personalised, on which virtual HTO was performed. Finite element analysis was performed to calculate the stresses in the plates arising from simulated physiological activities at three healing stages. The odds ratio indicative of the relative risk of fatigue failure of the HTO plates between the personalised and generic arms was obtained from a multi-level logistic model. RESULTS: Here we show, at 12 weeks post-surgery, the odds ratio indicative of the relative risk of fatigue failure was 0.14 (95%CI 0.01 to 2.73, p = 0.20). CONCLUSIONS: This novel (to the best of our knowledge) in silico trial, comparing the mechanical safety of a new personalised 3D printed high tibial osteotomy device with an existing generic device, shows that there is no increased risk of failure for the new personalised design compared to the existing generic commonly used device. Personalised high tibial osteotomy can overcome the main technical barriers for this type of surgery, our findings support the case for using this technology for treating early knee osteoarthritis.


Surgical treatment to realign the knee, called a high tibial osteotomy, is effective at relieving symptoms of knee osteoarthritis but the operation is difficult. A new personalised treatment with simpler surgery has been designed. The aim of this study was to investigate the safety of the new personalised treatment compared to the standard treatment. For the first time, a detailed computer simulation clinical trial was performed, using imaging data from 28 real patients. The computer simulation compared the risk of the implant failure between the personalised and standard treatments. The personalised treatment did not have a higher risk of implant failure than standard treatment. This supports further clinical studies looking at the benefits of personalised over standard realignment surgery. The personalised treatment has the potential to allow much more widespread use of realignment surgery to treat early knee osteoarthritis.

16.
Knee Surg Sports Traumatol Arthrosc ; 29(4): 1157-1163, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32602038

RESUMO

PURPOSE: Remnant preservation, in anterior cruciate ligament (ACL) reconstruction, has potential biological advantages. However, graft positioning remains vital to functional outcome and the prevention of failure. The aim of this study was to investigate the accuracy and precision of tibial tunnel positioning in remnant preservation single-bundle hamstring reconstruction. METHODS: Fifty consecutive adult patients, with isolated ACL rupture, were recruited to a prospective study. Remnant preservation was performed in all cases where > 25% of the native ACL was present. Three-dimensional computer tomography was preformed 3-6 months post-operatively to assess tibial tunnel position (using a grid-based measurement). Accuracy and precision of this technique were assessed against published anatomical data in direct comparison with the group where remnant preservation could not be performed. RESULTS: Two patients withdrew following surgery. In the remaining groups (31 remnant preservation; 17 non-remnant preservation), no difference was demonstrated in tunnel position (40.4 ± 6.7% (anterior-to-posterior) and 47.4 ± 1.5% (medial-to-lateral) vs. 38.8 ± 4.9% and 46.7 ± 1.5%, respectively; n.s.), accuracy (6.1% vs. 4.8%; n.s.) or precision (3.9% vs. 2.8%; n.s.). CONCLUSIONS: Remnant preservation can be safely performed without compromising tunnel position. Therefore, the potential benefits of this technique can be utilised, in clinical practice, without sacrificing the ability to optimize tibial tunnel positioning. LEVEL OF EVIDENCE: III.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Tíbia/cirurgia , Adulto , Feminino , Tendões dos Músculos Isquiotibiais/transplante , Humanos , Imageamento Tridimensional/métodos , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Tíbia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
17.
Knee ; 27(5): 1370-1377, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33010750

RESUMO

INTRODUCTION: The meniscal deficient knee often exists within the setting of associated pathology including instability, malalignment and chondral injury. The aim of this study was to establish the role of meniscal allograft transplantation (MAT) as part of a staged approach to treatment of the previously menisectomised knee and report: (a) primary data endpoints (pre and post-operative Knee Injury and Osteoarthritis outcome scores (KOOS), Tegner scores, satisfaction scores and graft survival), and (b) secondary endpoints:(complication/reoperation rates, and meniscal extrusion measurements as determined by MRI). MATERIAL AND METHODS: This prospective study included all patients that underwent arthroscopic fresh frozen allograft MAT at our institution (2010-2017) using a soft tissue fixation technique. RESULTS: Twenty-seven MAT procedures were performed in 26 patients (16 lateral, 11 medial). Ten patients underwent ACL reconstruction, three ACI and two osteotomy in the pre-MAT phase. Seven patients underwent ACI within the post-operative phase. Post-operative mean KOOS scores improved significantly in all subscales (p < .002) as did Tegner scores (p < .05). Graft survival was 100%, satisfaction rate 92%, and mean meniscal extrusion 3.04 mm. Post operatively, three patients required meniscal repair and a single patient, partial menisectomy of graft. Two patients underwent arthroscopic arthrolysis following MAT. CONCLUSIONS: This series highlights the multifactorial profile of the meniscal deficient knee and the role of MAT as a safe and reliable technique in the staged and comprehensive biologic treatment available to minimise symptoms and maximise outcomes. LEVEL OF EVIDENCE: 4.


Assuntos
Aloenxertos , Menisco/transplante , Adolescente , Adulto , Feminino , Seguimentos , Humanos , Masculino , Meniscectomia , Pessoa de Meia-Idade , Procedimentos Ortopédicos , Avaliação de Resultados da Assistência ao Paciente , Satisfação do Paciente , Cuidados Pós-Operatórios , Estudos Prospectivos , Adulto Jovem
18.
Knee Surg Relat Res ; 32(1): 17, 2020 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-32660634

RESUMO

BACKGROUND: Graft malposition is a risk factor for failure of anterior cruciate ligament reconstruction. A 70° arthroscope improves visualisation of the medial wall of the lateral femoral condyle without switching portals. We investigated whether the use of this arthroscope affected the accuracy and precision of femoral tunnel placement. METHODS: Fifty consecutive adult patients were recruited. Following one withdrawal and two exclusions, 47 patients (30 in group 1 (70° arthroscope), 17 in group 2 (30° arthroscope)) underwent three-dimensional computed tomography imaging using a grid-based system to measure tunnel position. RESULTS: No difference was found in the accuracy or precision of tunnels (mean position: group 1 = 33.3 ± 6.0% deep-shallow, 27.2 ± 5.2% high-low; group 2 = 31.7 ± 6.9% deep-shallow, 29.0 ± 6.2% high-low; not significant). A post-hoc power analysis suggests a study of 106 patients would be required. CONCLUSIONS: This pilot study suggests that tunnel position is not affected by the arthroscope used. An appropriately powered study could investigate this finding alongside other potential benefits of using a 70° arthroscope for this procedure. TRIAL REGISTRATION: ClinicalTrials.gov, NCT02816606. Registered on 28 June 2016.

19.
Indian J Orthop ; 54(4): 426-443, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32549958

RESUMO

BACKGROUND: Anterior cruciate ligament (ACL) injury is a common sports injury. Symptomatic knee instability after this injury is usually treated operatively through ACL reconstruction. The surgery involves a tendon graft being fixed in bony tunnels drilled through femur and tibia. The fixation of the graft is of critical importance to achieving good results. One of the commonest devices used to fix the graft in the femoral bony tunnel is a fixed loop cortical suspensory device. More recently, adjustable loop cortical suspension devices have been introduced, and have gained popularity for ACL reconstruction. These allow for adjusting the length of the suspension loop after insertion. There is currently much debate concerning whether the adjustable loop devices are superior or inferior to the fixed loop devices. PURPOSE: To critique and review the current biomechanical and clinical evidence on the use of adjustable loop devices in hamstring ACL reconstruction. To our knowledge, there have been no previous reviews of this topic. STUDY DESIGN: Systematic review. METHODS: This systematic review was conducted in accordance with PRISMA. Five databases were searched using multiple search terms and MeSH terms where possible. The following limits were applied: papers published in English and papers published in the last 21 years. RESULTS: Eleven laboratory and six clinical studies were reviewed. The laboratory-based studies have frequently shown elongation of adjustable loop devices to more than 3 mm under loading protocols, whereas the clinical studies have not shown any significant differences between the patients with fixed loop and the ones with adjustable loop devices. CLINICAL SIGNIFICANCE: This review shows a discrepancy between laboratory-based and clinical studies. The review of clinical studies in our paper would give future researchers confidence and act as a prompt to construct randomised clinical trials to investigate these devices further. CONCLUSION: We feel that more robust clinical randomised studies and trials are needed to evaluate these new devices.

20.
J Exp Orthop ; 7(1): 27, 2020 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-32394303

RESUMO

PURPOSE: To compare loop elongation after 5000 cycles, loop-elongation at failure, and load at failure of the fixed-loop G-Lok device and three adjustable-loop devices (UltraButton, RigidLoop Adjustable and ProCinch RT), during testing over extended cycles under high loading. METHODS: Five devices of each type were tested on a custom-built rig fixed to an Instron machine. The testing protocol had four stages: preloading, cyclic preconditioning, incremental cyclic loading and pull-to-failure. Outcome measures were loop elongation after 5000 cycles, loop-elongation at failure, and load at failure. RESULTS: The loop elongation after 5000 cycles for G-Lok was 1.46 ± 0.25 mm, which was comparable to that of RigidLoop (1.51 ± 0.16 mm, p = 1.000) and ProCinch (1.60 ± 0.09 mm, p = 1.000). In comparison, the loop elongation for UltraButton was 2.66 ± 0.28 mm, which was significantly larger than all other devices (p = 0.048). The failure load for all devices ranged between 1455 and 2178 N. G-Lok was significantly stronger than all adjustable-loop devices (p = 0.048). The elongation at failure was largest for UltraButton (4.20 ± 0.33 mm), which was significantly greater than G-Lok (3.17 ± 0.33 mm, p = 0.048), RigidLoop (2.88 ± 0.20 mm, p = 0.048) and ProCinch (2.78 ± 0.08 mm, p = 0.048). There was no significant difference in elongation at failure for the rest of the devices. CONCLUSIONS: Our study has shown that the G-Lok fixed-loop device and the three adjustable-loop devices (UltraButton, RigidLoop Adjustable and ProCinch RT) all elongated less than 3 mm during testing over an extended number of cycles at high loads, nonetheless, the fixed loop device performed best in terms of least elongation and highest load at failure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...