Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 14(3)2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36984905

RESUMO

Miniaturization of electrochemical components has become less common in the last decade, with the focus predominantly being the design and development of state-of-the-art microelectrodes for achieving small volume analysis of samples. However, such microelectrodes involve cumbersome processing procedures to convert the base material for the required application. A potential paradigm shift in such miniaturization could be achieved by using cheaper alternatives such as plastics to build electrochemical components, such as micropipette tips made of polypropylene, which are commercially available at ease. Hence, this work presents the design of an electrochemical working electrode based upon a micropipette tip, involving minimal processing procedures. Furthermore, such a working electrode was realized by sputtering silver onto a bare micropipette tip using a radio-frequency sputtering technique, to obtain electrical contacts on the tip, followed by hydrothermal growth of ZnO, which acted as the active electrode material. The ZnO nanostructures grown on the micropipette tip were characterized for their morphology and surface properties using a scanning electron microscope (SEM), laser microscope, Raman spectrometer, and X-ray photoelectron spectrometer (XPS). The developed micropipette tip-based electrode was then used as the working electrode in a three-electrode system, wherein its electrochemical stability and properties were analyzed using cyclic voltammetry (CV). Furthermore, the above system was used to detect glucose concentrations of 10-200 µM, to evaluate its sensing properties using amperometry. The developed working electrode exhibited a sensitivity of 69.02 µA/µM cm-2 and limit of detection of 67.5 µM, indicating the potential for using such modified micropipette tips as low-cost miniaturized sensors to detect various bio-analytes in sample solutions.

2.
Indian J Thorac Cardiovasc Surg ; 37(4): 438-441, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34220028

RESUMO

A 46-year-old male presented with breathlessness for a few months. He had been operated twice for liver hydatid cysts and once for right pulmonary hydatid cysts at other hospitals. Now he was found to have one hydatid cyst in the upper lobe of the left lung and multiple hydatid cysts adjoining left heart border. On computed tomography (CT) scan chest and echocardiography, it was difficult to ascertain whether these cysts were pulmonary or intrapericardial. Left ventricular ejection fraction (LVEF) was 25%. Enzyme-linked immunosorbent assay (ELISA) was positive for hydatid. Left posterolateral thoracotomy revealed dead hydatid cyst in upper lobe of the lung that was removed. Infected mother hydatid cyst was encountered inside pericardial sac. Scores of daughter hydatid cysts, varying in size from 1 to 30 mm, were scooped out intact from the pericardial cavity. There was significant improvement in cardiac activity, once the tamponade effect of hydatid cyst was removed. Pericardium was about 1 cm thick with lot of purulent and necrotic slough. To prevent future constrictive pericarditis, subtotal pericardiectomy was done. Intrapericardial hydatid cyst should be kept in mind whenever it obscures the heart border and patient has features of cardiac tamponade. Early surgical intervention may be required in these cases.

3.
J Nanosci Nanotechnol ; 21(9): 4861-4864, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33691879

RESUMO

For painless skin penetration, microneedles require optimal geometry due to human skin's inherent elastic properties. The fabrication of desired shape microneedle is very critical. To our knowledge, the polygonal geometry microneedle has not been investigated before. To address this issue, in this communication, we propose a novel cleanroom free fabrication of single metal microneedle with square cross section. The microneedle was fabricated using sputtering technique without any mask or template. The morphological analysis with respect to various sputtering parameters via. Argon (Ar) pipe position, rotating speed, working pressure was discussed in detail. The microneedle geometry, its assisted pain was visualized using finite element analysis (FEM). The theoretical evaluations were subsequently compared with experimentally fabricated microneedle. This is the first step towards more rational design of polygonal microneedle geometry.


Assuntos
Sistemas de Liberação de Medicamentos , Agulhas , Administração Cutânea , Desenho de Equipamento , Humanos , Microinjeções , Pele/metabolismo , Absorção Cutânea
4.
J Nanosci Nanotechnol ; 21(4): 2132-2138, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33500028

RESUMO

Industrialization can be greatly appreciated only by limiting the downside of the proposed technology. In this aeon, the recurrent monitoring of industries is statutory in detecting harmful gases and explosions for the global environment safety. Hence, employing specific gas sensors for detecting malicious gases benefits the welfare of the society. Thus, in this present work, we developed an energy efficient toxic gas sensor using ZnO thin film by seed layer assisted hydrothermal technique. The sensing mechanism of ZnO with the CO analyte was explained and the sensing parameters such as sensitivity, selectivity, response and recovery time were studied. Further, the developed energy efficient sensor was embedded with wireless sensor assembly for online monitoring which may be functional in developing portable, compact and cost-effective system for various real time industrial control applications.

5.
Mikrochim Acta ; 187(4): 253, 2020 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-32236746

RESUMO

This review (with 200 references) summarises the state of the art of gas and vapour sensors based on the use of vanadium oxide (VOx; with V occurring in various valencies) nanostructures. Following an introduction that covers the discussion of VOx and their stable forms, the first large section covers experimental techniques employed for preparing VOx nanostructures, with methods such as precipitation, hydrothermal synthesis, electrospinning, polyol techniques, laser deposition, and magnetron sputtering. The next section deals with VOx-based sensors for oxidising gases such as nitrogen dioxide, carbon dioxide, oxygen, and ozone. We then discuss sensors for reducing gases and vapour, such as various alcohols, formaldehyde, hydrogen, methane, various amines, hydrogen sulphide, LPG, and neutral gases and vapours such as helium and humidity. An overview of the wealth of materials, methods, and sensing characteristics such as sensor response, analytical ranges, and operational temperatures is presented in Tables. The final section briefs the VOx-based flexible sensors, followed by a concluding section that summarises the current status and challenges, and gives an outlook on potential future perspectives. Graphical abstract The state of the art of vanadium oxide nanostructures in gas/vapour sensing has been discussed in this work.

6.
Anal Chim Acta ; 1106: 148-160, 2020 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-32145843

RESUMO

Methane (CH4) gas, the second most potent greenhouse gas share a substantial role in contributing to the global warming and it is a necessary pre-requisite to detect the release of CH4 into the environment at its early stage to combat climate change. In that front, this work is focussed to develop an effective CH4 gas sensor using vanadium pentoxide (V2O5) thin films that works at an operating temperature of ∼100 °C. To understand the effect of sputtering power towards the structural characteristics of V2O5 films, X-ray diffraction (XRD) and high-resolution transmission electron microscopy (HR-TEM) analysis were performed from which the orthorhombic polycrystalline structure of V2O5 thin films was confirmed with varied texture co-efficient. Further, the surface elemental studies using X-ray photoelectron spectroscopy (XPS) confirmed the prominence of V+5 oxidation state from the binding energy of V2p3/2 and O1s peak. The effect of sputtering power on the growth of different nanostructures were observed using field-emission scanning electron microscopy (FE-SEM). The critical role of adsorption and desorption kinetics of the deposited nanostructures were explained through first order kinetics based on Elovich model and the phase stability of different nanostructures were evaluated using Raman spectral analysis. This work achieved the sensor response of about ∼8% towards CH4 at an operating temperature of 100 °C towards 50 ppm concentration.

7.
ACS Sens ; 5(4): 911-916, 2020 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-32157870

RESUMO

Heatstroke is a serious illness that can potentially damage many victims every year. Many intelligent physical sensors have been developed to prevent heatstroke fatalities. However, it remains a challenge to fabricate skin-adhesive, small, and low-cost sensors for in situ heatstroke detection to overcome the weaknesses of the physical sensors. As far as we know, this is the first breakthrough for exploiting a PDMS based freestanding nanosheet skin patch consisting of pH sensing elements (antimony/antimony oxide and silver/silver iodate) to achieve high pH sensitivity and repeatability. The sensing elements were investigated for structural and morphological properties. The easy to use and easy to fabricate nanosheet sensor exhibited a linear pH response of -43 mV/pH. Overall, the developed sensor showed high sensitivity, repeatability, and stability. Our initial results indicate that the developed sensor adhered well to a skin surface. It is expected that this proof of concept approach gives reliable fabrication and measurement unlike other physical sensors.


Assuntos
Golpe de Calor/diagnóstico , Dispositivos Eletrônicos Vestíveis/tendências , Humanos , Concentração de Íons de Hidrogênio
8.
ACS Appl Mater Interfaces ; 11(33): 30247-30258, 2019 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-31330096

RESUMO

In this present work, TiO2-SiO2-sulfur (Ti-Si-S) nanohybrid material was successfully prepared using TiO2 nano powder, TEOS sol-gel precursor, and elemental sulfur as raw material by sol-gel process and hydrothermal method at 120 °C temperature. Raman spectroscopy, XRD, SEM, TEM, and N2 absorption-desorption characterized the synthesized nanohybrid material. The characterization results confirmed the homogeneous distribution of sulfur in the nanohybrid material. The size of the Ti-Si-S nanohybrid material is vary between 20 and 40 nm and the surface areas of the nanohybrid material was measured using N2 absorption-desorption, which showed value of 57.2 m2 g-1. The potential of Ti-Si-S nanohybrid material as an adsorbent was further tested to adsorb methylene blue (MB) from aqueous solution. Adsorption performance of hybrid material was highly influenced by the solution pH and mass of adsorbent. The adsorption of MB using Ti-Si-S nanohybrid material was homogeneous monolayer adsorption, which followed the Langmuir adsorption isotherm with a qe,max value of 804.80 mg g-1 and pseudo-second-order rate equation. The dye diffusion mechanism partially followed both intraparticle and liquid film diffusion mechanisms. Thermodynamics studies predicted the spontaneous and endothermic nature of the whole adsorption process. The Ti-Si-S nanohybrid material was used for six repeated cycles of MB dye adsorption-desorption.

9.
RSC Adv ; 9(52): 30226-30239, 2019 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-35530198

RESUMO

In recent times, the development of breath sensors for the detection of Diabetic Keto-Acidosis (DKA) has been gaining prominent importance in the field of health care and advanced diagnostics. Acetone is one of the prominent biomarkers in the exhaled breath of persons affected by DKA. In this background, nanostructured cobalt oxide sensing elements were fabricated using a spray pyrolysis technique at different deposition temperatures (473 to 773 K in steps of 100 K) towards the fabrication of an acetone sensor. The influence of deposition temperature on the various properties of the nanostructured cobalt oxide thin films was investigated. Formation of cubic spinel phase cobalt oxide was confirmed from the structural analysis. The shifting of plane orientation from (3 1 1) to (2 2 0) at 773 K deposition temperature revealed the migration of cobalt atoms to the highly favorable energy positions. Further, the downshifted peak absorption wavelength and upshifted PL profile at higher deposition temperature confirmed the migration of cobalt ions. The sensor fabricated at higher deposition temperature (773 K) showed a sensing response of 235 at room temperature towards 50 ppm of acetone. Also, the fabricated sensor showed a lower detection limit (LOD) of 1 ppm with the response-recovery times of 6 and 4 s, respectively. The LOD reported here is lower than the minimum threshold level (1.71 ppm) signifying the presence of DKA.

10.
ACS Appl Mater Interfaces ; 9(26): 21651-21659, 2017 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-28585801

RESUMO

Acid-base homeostasis (body pH) inside the body is precisely controlled by the kidneys and lungs and buffer systems, such that even a minor pH change could severely affect many organs. Blood and urine pH tests are common in day-to-day clinical trials and require little effort for diagnosis. There is always a great demand for in vivo testing to understand more about body metabolism and to provide effective diagnosis and therapy. In this article, we report the simple fabrication of microneedle-based direct, label-free, and real-time pH sensors. The reference and working electrodes were Ag/AgCl thick films and ZnO thin films on tungsten (W) microneedles, respectively. The morphological and structural characteristics of microneedles were carefully investigated through various analytical methods. The developed sensor exhibited a Nernstian response of -46 mV/pH. Different conditions were used to test the sensor to confirm their accuracy and stability, such as various buffer solutions, with respect to time, and we compared the reading with commercial pH electrodes. Besides that, the fabricated microneedle sensor ability is proven by in vivo testing in mouse cerebrospinal fluid (CSF) and bladders. The pH sensor procedure reported here is totally reversible, and results were reproducible after several rounds of testing.


Assuntos
Bexiga Urinária/química , Animais , Técnicas Biossensoriais , Eletrodos , Concentração de Íons de Hidrogênio , Camundongos , Agulhas
11.
ACS Appl Mater Interfaces ; 9(6): 5193-5203, 2017 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-28117972

RESUMO

The present study is concerned about the development of highly sensitive and stable microfluidic pH sensor for possible identification of circulating tumor cells (CTCs) in blood. The precise pH measurements between silver-silver chloride (Ag/AgCl) reference electrode and zinc oxide (ZnO) working electrode have been investigated in the microfluidic device. Since there is a direct link between pH and cancer cells, the developed device is one of the valuable tools to examine circulating tumor cells (CTCs) in blood. The ZnO-based working electrode was deposited by radio frequency (rf) sputtering technique. The potential voltage difference between the working and reference electrodes (Ag/AgCl) is evaluated on the microfluidic device. The ideal Nernstian response of -43.71165 mV/pH was achieved along with high stability and quick response time. Finally, to evaluate the real time capability of the developed microfluidic device, in vitro testing was done with A549, A7r5, and MDCK cells.


Assuntos
Microfluídica , Eletrodos , Humanos , Concentração de Íons de Hidrogênio , Células Neoplásicas Circulantes , Óxido de Zinco
12.
J Nanosci Nanotechnol ; 16(1): 489-96, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27398478

RESUMO

Zinc oxide (ZnO) thin films were deposited on glass substrates using chemical spray pyrolysis technique at different substrate temperatures such as 523, 623 and 723 K. X-ray diffraction (XRD) patterns confirmed the formation of polycrystalline films with hexagonal wurtzite crystal structure and revealed the change in preferential orientation of the crystal planes. Scanning electron micrographs showed the formation of uniformly distributed spherical shaped grains at low deposition temperature and pebbles like structure at the higher temperature. Transmittance of 85% was observed for the film deposited at 723 K. The band gap of the films was found to be increased from 3.15 to 3.23 eV with a rise in deposition temperature. The electrical conductivity of the films was found to be improved with an increase in substrate temperature. Surface of ZnO thin films deposited at 523 K, 623 K and 723 K were found to be hydrophobic with the contact angles of 92°, 105° and 128° respectively. The room temperature gas sensing characteristics of all the films were studied and found that the film deposited at 623 K showed a better response towards ammonia vapour.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...