Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 32(8): 14471-14489, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38859391

RESUMO

We propose a method to analyze the characteristics of scintillator screens for neutron imaging applications. Using calculations based on the theory of cascaded linear steps as well as experimental measurements, we compared the characteristics of different lithium- and gadolinium-based scintillator screens. Our results show that, despite their much lower light output, gadolinium-based scintillators outperform lithium-based scintillators in terms of noise characteristics for a variety of imaging setups. However, the relative performance of scintillator screens is highly dependent on the other setup characteristics such as the beam spectrum, field of view, used optical lens and size of the camera sensor. Consequently, the selection of the best scintillator screen - as well as the scintillator characteristics assessment in new developments - requires a systematic consideration of all these elements, as enabled by the framework presented here.

2.
Mater Struct ; 57(4): 56, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38601013

RESUMO

The steel-concrete interface (SCI) is known to play a major role in corrosion of steel in concrete, but a fundamental understanding is still lacking. One reason is that concrete's opacity complicates the study of internal processes. Here, we report on the application of bimodal X-ray and neutron microtomography as in-situ imaging techniques to elucidate the mechanism of steel corrosion in concrete. The study demonstrates that the segmentation of the specimen components of relevance-steel, cementitious matrix, aggregates, voids, corrosion products-obtained through bimodal X-ray and neutron imaging is more reliable than that based on the results of each of the two techniques separately. Further, we suggest the combination of tomographic in-situ imaging with ex-situ SEM analysis of targeted sections, selected based on the segmented tomograms. These in-situ and ex-situ characterization techniques were applied to study localized corrosion in a very early stage under laboratory chloride-exposure conditions, using reinforced concrete cores retrieved from a concrete bridge. Several interesting observations were made. First, the acquired images revealed the formation of several corrosion sites close to each other. Second, the morphology of the corrosion pits was relatively shallow. Finally, only about half of the total 31 corrosion initiation spots were in close proximity to interfacial macroscopic air voids, and > 90% of the more than 160 interfacial macroscopic air voids were free from corrosion. The findings have implications for the mechanistic understanding of corrosion of steel in concrete and suggest that multimodal in-situ imaging is a valuable technique for further related studies. Supplementary Information: The online version contains supplementary material available at 10.1617/s11527-024-02337-7.

3.
Pharm Res ; 41(3): 547-556, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38326531

RESUMO

OBJECTIVE: This study aimed to investigate the movement of liquid in the needle region of staked-in-needle pre-filled syringes using neutron imaging and synchrotron X-ray tomography. The objective was to gain insights into the dynamics of liquid presence and understand the factors contributing to needle clogging. METHODS: Staked-in-needle pre-filled syringes were examined using neutron radiography and synchrotron X-ray phase-contrast computed tomography. Neutron radiography provided a 2D visualization of liquid presence in the needle, while synchrotron X-ray tomography offered high-resolution 3D imaging to study detailed morphological features of the liquid. RESULTS: Neutron radiography revealed liquid presence in the needle region for as-received samples and after temperature and pressure cycling. Pressure cycling had a more pronounced effect on liquid formation. Synchrotron X-ray tomography confirmed the presence of liquid and revealed various morphologies, including droplets of different sizes, liquid segments blocking sections of the needle, and a thin layer covering the needle wall. Liquid presence was also observed between the steel needle and the glass barrel. CONCLUSIONS: The combination of neutron imaging and synchrotron X-ray tomography provided valuable insights into the dynamics of liquid movement in staked-in-needle pre-filled syringes. Temperature and pressure cycling were found to contribute to additional liquid formation, with pressure changes playing a significant role. The detailed morphological analysis enhanced the understanding of microstructural arrangements within the needle. This research contributes to addressing the issue of needle clogging and can guide the development of strategies to improve pre-filled syringe performance.


Assuntos
Agulhas , Tomografia Computadorizada por Raios X , Pressão , Temperatura , Vidro/química
4.
ACS Energy Lett ; 6(12): 4365-4373, 2021 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-34917771

RESUMO

Fast neutron imaging is a nondestructive technique for large-scale objects such as nuclear fuel rods. However, present detectors are based on conventional phosphors (typically microcrystalline ZnS:Cu) that have intrinsic drawbacks, including light scattering, γ-ray sensitivity, and afterglow. Fast neutron imaging with colloidal nanocrystals (NCs) was demonstrated to eliminate light scattering. While lead halide perovskite (LHP) FAPbBr3 NCs emitting brightly showed poor spatial resolution due to reabsorption, the Mn2+-doped CsPb(BrCl)3 NCs with oleyl ligands had higher resolution because of large apparent Stokes shift but insufficient concentration for high light yield. In this work, we demonstrate a NC scintillator that features simultaneously high quantum yields, high concentrations, and a large apparent Stokes shift. In particular, we use long-chain zwitterionic ligand capping in the synthesis of Mn2+-doped CsPb(BrCl)3 NCs that allows for attaining very high concentrations (>100 mg/mL) of colloids. The emissive behavior of these ASC18-capped NCs was carefully controlled by compositional tuning that permitted us to select for high quantum yields (>50%) coinciding with Mn-dominated emission for minimal self-absorption. These tailored Mn2+:CsPb(BrCl)3 NCs demonstrated over 8 times brighter light yield than their oleyl-capped variants under fast neutron irradiation, which is competitive with that of near-unity FAPbBr3 NCs, while essentially eliminating self-absorption. Because of their rare combination of concentrations above 100 mg/mL and high quantum yields, along with minimal self-absorption for good spatial resolution, Mn2+:CsPb(BrCl)3 NCs have the potential to displace ZnS:Cu as the leading scintillator for fast neutron imaging.

5.
ACS Nano ; 14(11): 14686-14697, 2020 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-32897688

RESUMO

Fast neutrons offer high penetration capabilities for both light and dense materials due to their comparatively low interaction cross sections, making them ideal for the imaging of large-scale objects such as large fossils or as-built plane turbines, for which X-rays or thermal neutrons do not provide sufficient penetration. However, inefficient fast neutron detection limits widespread application of this technique. Traditional phosphors such as ZnS:Cu embedded in plastics are utilized as scintillators in recoil proton detectors for fast neutron imaging. However, these scintillation plates exhibit significant light scattering due to the plastic-phosphor interface along with long-lived afterglow (on the order of minutes), and therefore alternative solutions are needed to increase the availability of this technique. Here, we utilize colloidal nanocrystals (NCs) in hydrogen-dense solvents for fast neutron imaging through the detection of recoil protons generated by neutron scattering, demonstrating the efficacy of nanomaterials as scintillators in this detection scheme. The light yield, spatial resolution, and neutron-vs-gamma sensitivity of several chalcogenide (CdSe and CuInS2)-based and perovskite halide-based NCs are determined, with only a short-lived afterglow (below the order of seconds) observed for all of these NCs. FAPbBr3 NCs exhibit the brightest total light output at 19.3% of the commercial ZnS:Cu(PP) standard, while CsPbBrCl2:Mn NCs offer the best spatial resolution at ∼2.6 mm. Colloidal NCs showed significantly lower gamma sensitivity than ZnS:Cu; for example, 79% of the FAPbBr3 light yield results from neutron-induced radioluminescence and hence the neutron-specific light yield of FAPbBr3 is 30.4% of that of ZnS:Cu(PP). Concentration and thickness-dependent measurements highlight the importance of increasing concentrations and reducing self-absorption, yielding design principles to optimize and foster an era of NC-based scintillators for fast neutron imaging.

6.
Sci Rep ; 9(1): 18611, 2019 12 09.
Artigo em Inglês | MEDLINE | ID: mdl-31819087

RESUMO

Violin varnishes are known to affect both moisture absorption and vibrational properties of violin wood. However, traditional multi-layered varnish systems suffer from substantial wear as a result of intensive use, which calls for deeper understanding of the specific impact of individual layers. Using sophisticated in-situ neutron imaging and vibrational modal analysis, we show how wood sorption and vibrational behavior of tonewood depend on the build-up of the varnish system. The results demonstrate the protective effect of complete coatings and emphasize that strongly worn regions cannot accomplish the function as an effective moisture barrier, which might pose a risk for frequently played or aged string instruments. Furthermore, the build-up of the varnish system affects the vibrational properties of the tonewood, influencing its final sound quality. This delicate interplay should be considered both for the handling of antique and aged violins and for the production of modern high-quality instruments.

7.
Herit Sci ; 7(1): 29, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31231523

RESUMO

Chloride ions are an important actor in the corrosion of iron-based archaeological artifact. To stop this degradation, excavated objects are subjected to dechlorination treatment. However, there is no guarantee that this will remove all chloride from the object, as some can be found deep inside the object. To assess the ability of dechlorination treatment to remove chloride, we propose to use both neutron and X-ray tomography. Indeed, these tomographic techniques have sensitivities to different elements and are thus complementary. Neutron tomography in particular is highly sensitive to the presence of chloride. This study demonstrate that this methodology allows to detect local and global changes caused by the dechlorination treatment, an useful tool to assess the effectiveness of a treatment and potentially improve it.

8.
PLoS One ; 14(1): e0210300, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30608985

RESUMO

We describe in this paper the experimental procedure, the data treatment and the quantification of the black body correction: an experimental approach to compensate for scattering and systematic biases in quantitative neutron imaging based on experimental data. The correction algorithm is based on two steps; estimation of the scattering component and correction using an enhanced normalization formula. The method incorporates correction terms into the image normalization procedure, which usually only includes open beam and dark current images (open beam correction). Our aim is to show its efficiency and reproducibility: we detail the data treatment procedures and quantitatively investigate the effect of the correction. Its implementation is included within the open source CT reconstruction software MuhRec. The performance of the proposed algorithm is demonstrated using simulated and experimental CT datasets acquired at the ICON and NEUTRA beamlines at the Paul Scherrer Institut.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Difração de Nêutrons/métodos , Nêutrons , Algoritmos , Viés , Simulação por Computador , Cobre/química , Bases de Dados Factuais , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Chumbo/química , Difração de Nêutrons/estatística & dados numéricos , Imagens de Fantasmas , Software , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Água/química
9.
Sci Rep ; 5: 15627, 2015 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-26496823

RESUMO

Gas generation as a result of electrolyte decomposition is one of the major issues of high-performance rechargeable batteries. Here, we report the direct observation of gassing in operating lithium-ion batteries using neutron imaging. This technique can be used to obtain qualitative as well as quantitative information by applying a new analysis approach. Special emphasis is placed on high voltage LiNi0.5Mn1.5O4/graphite pouch cells. Continuous gassing due to oxidation and reduction of electrolyte solvents is observed. To separate gas evolution reactions occurring on the anode from those associated with the cathode interface and to gain more insight into the gassing behavior of LiNi0.5Mn1.5O4/graphite cells, neutron experiments were also conducted systematically on other cathode/anode combinations, including LiFePO4/graphite, LiNi0.5Mn1.5O4/Li4Ti5O12 and LiFePO4/Li4Ti5O12. In addition, the data were supported by gas pressure measurements. The results suggest that metal dissolution in the electrolyte and decomposition products resulting from the high potentials adversely affect the gas generation, particularly in the first charge cycle (i.e., during graphite solid-electrolyte interface layer formation).

10.
PLoS One ; 8(1): e54730, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23382949

RESUMO

Olive trees are a classic component of Mediterranean environments and some of them are known historically to be very old. In order to evaluate the possibility to use olive tree-rings for dendrochronology, we examined by various methods the reliability of olive tree-rings identification. Dendrochronological analyses of olive trees growing on the Aegean island Santorini (Greece) show that the determination of the number of tree-rings is impossible because of intra-annual wood density fluctuations, variability in tree-ring boundary structure, and restriction of its cambial activity to shifting sectors of the circumference, causing the tree-ring sequences along radii of the same cross section to differ.


Assuntos
Olea/anatomia & histologia , Olea/crescimento & desenvolvimento , Cronologia como Assunto , Grécia
11.
Ann Bot ; 107(2): 293-302, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21131386

RESUMO

BACKGROUND AND AIMS: Density is a crucial variable in forest and wood science and is evaluated by a multitude of methods. Direct gravimetric methods are mostly destructive and time-consuming. Therefore, faster and semi- to non-destructive indirect methods have been developed. METHODS: Profiles of wood density variations with a resolution of approx. 50 µm were derived from one-dimensional resistance drillings, two-dimensional neutron scans, and three-dimensional neutron and X-ray scans. All methods were applied on Terminalia superba Engl. & Diels, an African pioneer species which sometimes exhibits a brown heart (limba noir). KEY RESULTS: The use of X-ray tomography combined with a reference material permitted direct estimates of wood density. These X-ray-derived densities overestimated gravimetrically determined densities non-significantly and showed high correlation (linear regression, R(2) = 0·995). When comparing X-ray densities with the attenuation coefficients of neutron scans and the amplitude of drilling resistance, a significant linear relation was found with the neutron attenuation coefficient (R(2) = 0·986) yet a weak relation with drilling resistance (R(2) = 0·243). When density patterns are compared, all three methods are capable of revealing the same trends. Differences are mainly due to the orientation of tree rings and the different characteristics of the indirect methods. CONCLUSIONS: High-resolution X-ray computed tomography is a promising technique for research on wood cores and will be explored further on other temperate and tropical species. Further study on limba noir is necessary to reveal the causes of density variations and to determine how resistance drillings can be further refined.


Assuntos
Terminalia/crescimento & desenvolvimento , Tomografia Computadorizada por Raios X/métodos , Árvores/crescimento & desenvolvimento , Fenômenos Biomecânicos , Conservação dos Recursos Naturais , Densitometria , Madeira/crescimento & desenvolvimento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...