Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 11736, 2023 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-37474743

RESUMO

Consumer wearable technology use is widespread and there is a need to validate measures obtained in uncontrolled settings. Because no standard exists for the treatment of heart rate data during exercise, the effect of different approaches on reliability (Coefficient of Variation [CV], Intraclass Correlation Coefficient [ICC]) and validity (Mean Absolute Percent Error [MAPE], Lin's Concordance Correlation Coefficient [CCC)] were determined in the Polar Verity Sense and OH1 during trail running. The Verity Sense met the reliability (CV < 5%, ICC > 0.7) and validity thresholds (MAPE < 5%, CCC > 0.9) in all cases. The OH1 met reliability thresholds in all cases except entire session average (ICC = 0.57). The OH1 met the validity MAPE threshold in all cases (3.3-4.1%), but not CCC (0.6-0.86). Despite various heart rate data processing methods, the approach may not affect reliability and validity interpretation provided adequate data points are obtained. It is also possible that a large volume of data will artificially inflate metrics.


Assuntos
Exercício Físico , Dispositivos Eletrônicos Vestíveis , Humanos , Frequência Cardíaca/fisiologia , Reprodutibilidade dos Testes , Exercício Físico/fisiologia , Algoritmos
2.
Int J Exerc Sci ; 15(4): 834-845, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35992502

RESUMO

Indoor sport rock climbing has been increasing in popularity both recreationally and competitively. Despite this increase in popularity, the physiological responses to sport climbing as an exercise to specific muscle groups are not well defined. The purpose of this study was to quantify the change in handgrip strength over a 30-minute bout of continuous climbing, specifically in intermediate-level sport climbers. Ten intermediate rock climbers (age = 27 ± 2 years; climbing experience: 7.3 ± 1.5 years) completed baseline handgrip strength and forearm girth measurements. Each participant ascended one of two 5.9 difficulty routes as many times as possible in 30 minutes. After each ascent, heart rate was obtained, and handgrip strength and forearm girth were measured. Data were analyzed using repeated-measures ANOVA with significance set at α < 0.05. Dominant arm handgrip strength decreased by 22%, and non-dominant handgrip strength reduced by 23%. Dominant and non-dominant forearm girth increased by 4.5% and 4.4%, respectively. Weak but significant negative correlations were observed between handgrip strength and forearm girth in dominant (r = -0.311, p = 0.001) and non-dominant limbs (r = -.491, p = 0.001). These results indicate a relationship between increased forearm girth and decreases in muscular strength. Since handgrip strength decreases substantially during a 30-min climb in intermediate rock climbers, this population would be advised to carefully monitor recovery time between bouts.

3.
Artigo em Inglês | MEDLINE | ID: mdl-34360425

RESUMO

This double-blinded, placebo-controlled, crossover study examined the effect of induced painful sensation (via acute Beta Alanine (B-ALA) ingestion) on Love and Care of Nature (LCN), heart rate (HR), rating of perceived exertion (RPE), and McGill Pain Questionnaire (MPQ) during outdoor exercise. Twenty participants volunteered on consecutive days to complete a 0.8 km (0.5 mi) up-hill hike after consuming either B-ALA (6.4 g) or placebo. Immediately after consumption participants answered LCN, RPE, and MPQ questionnaires, immersed in a natural environment for 45 min, and then completed a hike as quickly as possible without running. No difference in HR (p = 0.846), or RPE (p = 0.606) were observed between treatments. Total MPQ scores increased with consumption of B-ALA (p = 0.001). An increased LCN score was observed following exercise regardless of condition (p = 0.035). The results demonstrate that acute B-ALA supplementation is effective in increasing perceived pain sensations. The results also demonstrate an increase in LCN in the presence of increased perceptions of pain sensations during exercise.


Assuntos
Imersão , Esforço Físico , Estudos Cross-Over , Método Duplo-Cego , Ingestão de Alimentos , Frequência Cardíaca , Humanos , Consumo de Oxigênio , Dor , Percepção da Dor , beta-Alanina
4.
PLoS One ; 15(8): e0238569, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32866216

RESUMO

Validation of heart rate responses in wearable technology devices is generally composed of laboratory-based protocols that are steady state in nature and as a result, high accuracy measures are returned. However, there is a need to understand device validity in applied settings that include varied intensities of exercise. The purpose was to determine concurrent heart rate validity during trail running. Twenty-one healthy participants volunteered (female n = 10, [mean (SD)]: age = 31 [11] years, height = 173.0 [7] cm, mass = 75.6 [13] kg). Participants were outfitted with wearable technology devices (Garmin Fenix 5 wristwatch, Jabra Elite Sport earbuds, Motiv ring, Scosche Rhythm+ forearm band, Suunto Spartan Sport watch with accompanying chest strap) and completed a self-paced 3.22 km trail run while concurrently wearing a criterion heart rate strap (Polar H7 heart rate monitor). The trail runs were out-and-back with the first 1.61 km in an uphill direction, and the 1.61 return being downhill in nature. Validity was determined through three methods: Mean Absolute Percent Error (MAPE), Bland-Altman Limits of Agreement (LOA), and Lin's Concordance Coefficient (rC). Validity measures overall are as follows: Garmin Fenix 5 (MAPE = 13%, LOA = -32 to 162, rC = 0.32), Jabra Elite Sport (MAPE = 23%, LOA = -464 to 503, rC = 0.38), Motiv ring (MAPE = 16%, LOA = -52 to 96, rC = 0.29), Scosche Rhythm+ (MAPE = 6%, LOA = -114 to 120, rC = 0.79), Suunto Spartan Sport (MAPE = 2%, LOA = -62 to 61, rC = 0.96). All photoplethysmography-based (PPG) devices displayed poor heart rate agreement during variable intensity trail running. Until technological advances occur in PPG-based devices allowing for acceptable agreement, heart rate in outdoor environments should be obtained using an ECG-based chest strap that can be connected to a wristwatch or other comparable receiver.


Assuntos
Determinação da Frequência Cardíaca/instrumentação , Determinação da Frequência Cardíaca/métodos , Frequência Cardíaca/fisiologia , Corrida/fisiologia , Tecnologia/instrumentação , Tecnologia/métodos , Adulto , Exercício Físico/fisiologia , Teste de Esforço/instrumentação , Teste de Esforço/métodos , Feminino , Monitores de Aptidão Física , Humanos , Masculino , Fotopletismografia/métodos , Dispositivos Eletrônicos Vestíveis
5.
Int J Sports Med ; 40(8): 498-502, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31288288

RESUMO

Footpod monitors are wearable devices attaching to the shoe with the ability to sense oscillations in leg movement; however, few studies provide reliability. The purpose was to provide reliability data for outdoor tasks as measured by the Stryd Power Meter, which is a footpod monitor. Young healthy individuals (N=20, male n=12, female n=8) completed two 5-min self-paced walks along a trail, and two 5-min trail runs. Reliability of the tasks was determined using Coefficient of Variation (CV), Intraclass Correlation (ICC), and 95% confidence intervals (CI). Measures during trail running that returned a CV less than 10%, met the ICC threshold of 0.70, and displayed good to excellent 95% CI included pace, average elapsed power, average elapsed form power, average elapsed leg spring, and vertical oscillation. The only variable during walking to meet these criteria was maximal power (CV=4.02%, ICC=0.968, CI=0.902, 0.989). Running tasks completed on a trail generally return more consistent measures for variables that can be obtained from the Stryd footpod device than walking tasks.


Assuntos
Monitores de Aptidão Física/normas , Corrida/fisiologia , Caminhada/fisiologia , Desenho de Equipamento , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Análise e Desempenho de Tarefas , Adulto Jovem
6.
Int J Exerc Sci ; 8(4): 425-430, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-27293503

RESUMO

Use of wearable technology to obtain various body metrics appears to be a trending phenomenon. However there is very little literature supporting the notion that these apparatuses can be used for research purposes in the field. The purpose of this study was to utilize Hexoskin wearable technology shirts (HxS) to obtain data in a pilot study using a trail hiking situation. Ten individuals (male, n = 4, female n = 6) volunteered to participate. On the first day, volunteers completed two approximately flat trail hikes at a self-preferred pace with a 15-minute rest between trials. On the second day, participants completed a strenuous uphill hike (17.6% grade) with a 15-minute rest at the summit and then completed the downhill portion. Body metrics provided by the HxS were average heart rate (HR), maximal HR (MHR), total energy expenditure (EE), average respiratory rate (RR), maximal respiratory rate (MRR), total steps (SC), and cadence (CA). Other measurements obtained were systolic and diastolic blood pressure (SBP, DBP), and ratings of perceived exertion (RPE). Data were analyzed using both one-way repeated measures analysis of variance (ANOVA) with significance accepted at p≤0.05 and intraclass correlation coefficients (ICC) for each variable. Both were determined using Statistical Package for the Social Sciences software (SPSS). No significant differences for trail type were noted for MHR (p=0.38), RR (p=0.45) or MRR (p=0.31). The uphill trail elicited significantly elevated HR (up=154±24 bpm, easy=118±11 bpm, down=129±19 bpm; p=0.04) and EE (up=251±78 kcal, easy=124±38 kcal, down=171±52 kcal; p=0.02). Significant ICC were observed for DBP (r = 0.80, p = 0.02), RR (r = 0.98, p = 0.01), SC (r = 0.97, p = 0.01) and RPE (r = 0.94, p = 0.01). Non-significant correlation were noted for uphill RR vs CA (r=0.51, p=0.16) or RPE vs SBP (r=0.03, p=0.94), HR (r=0.60, p=0.12), and MHR (r=0.70, p=0.051). We utilized HxS to provide physiological data in an applied setting. It should be noted that HR did not register in 5 out of 10 subjects on the easy trail, and 8 of 10 participants during the uphill hike. Additionally, estimated EE appears to be linked to HR intensity. Future investigations taken in an outdoor environment should take these findings into consideration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...