Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 251
Filtrar
1.
Circ J ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38987207

RESUMO

BACKGROUND: Coronary angioscopy (CAS) has 2 unique abilities: direct visualization of thrombi and plaque color. However, in the recent drug-eluting stent (DES) era, serial CAS findings after DES implantation have not been fully elucidated. We investigated the impact of CAS findings after implantation of a polymer-free biolimus A9-coated stent (PF-BCS) or durable polymer everolimus-eluting stent (DP-EES).Methods and Results: We investigated serial CAS and optical coherence tomography (OCT) findings at 1 and 12 months in 99 patients who underwent PF-BCS or DP-EES implantation. We evaluated factors correlated with angioscopic thrombi and yellow plaque, and the clinical impact of both thrombi and yellow plaque at 12 months (BTY). The BTY group included 17 (22%) patients. The incidence and grade of thrombi and yellow plaque decreased from 1 to 12 months. Although no patients had newly appearing thrombi at 12 months, 2 DP-EES patients had newly appearing yellow plaque at 12 months. Multivariable analysis revealed HbA1c, minimum stent area, and adequate strut coverage were significant factors correlated with 12-month angioscopic thrombi, and DP-EESs were significantly correlated with 12-month yellow plaque. However, BTY was not correlated with clinical events. CONCLUSIONS: The management of diabetes, stent area, and adequate stent coverage are important for intrastent thrombogenicity and polymer-free stents are useful for stabilizing plaque vulnerability.

2.
J Cardiol Cases ; 30(1): 20-23, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007041

RESUMO

An 83-year-old woman with claudication in the right lower extremity was referred to our hospital. Since angiography showed severe stenosis with a severely calcified lesion extending from the ostial to proximal part of the right superficial femoral artery (SFA), endovascular therapy (EVT) with the Jetstream™ atherectomy system (Boston Scientific, Marlborough, MA, USA) and paclitaxel-coated balloon (PCB) was performed. Atherectomy was performed using the Jetstream™ atherectomy catheter SC 1.85, followed by an additional atherectomy using the Jetstream™ atherectomy catheter XC 2.1/3.0. Subsequently, angiography and intravascular ultrasound (IVUS) images showed the enlargement of lumen area due to the reduction of calcified plaque, but even some of the healthy media on the side free of calcified plaque had been removed. Next, a PCB dilation was performed, and the final angiography showed adequate dilation. However, the symptoms recurred 9 months after EVT. Angiography revealed an enlarged vessel suggestive of pseudoaneurysm at the ostial part of the right SFA and severe stenosis distal to the enlarged vessel. IVUS images showed a pseudoaneurysm and severe stenosis due to calcified nodules distal to the pseudoaneurysm. This case suggests that pseudoaneurysm is a potential complication of EVT with the Jetstream™ atherectomy system and PCB for SFA lesions. Learning objective: The Jetstream™ atherectomy system (Boston Scientific, Marlborough, MA, USA) has developed to improve outcomes for femoropopliteal artery lesions with severely calcified lesions in lower extremity arterial disease by removing calcified plaque and improving vascular compliance. Several clinical reports demonstrated durable patency rates and low complication rates after endovascular therapy using the atherectomy device. However, pseudoaneurysm is a potential complication of endovascular therapy with the Jetstream™ atherectomy system.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38923660

RESUMO

BACKGROUND: Although technological improvements in intravascular ultrasound (IVUS) may reduce technical failures in endovascular therapy (EVT), perioperative complications (POCs) associated with IVUS use may increase. AIMS: This study investigated the impact of IVUS on periprocedural outcomes in symptomatic lower-extremity artery disease (LEAD) patients undergoing EVT. METHODS: This study evaluated 28,088 symptomatic LEAD patients who underwent EVT between January 2021 and December 2021 using a prospective nationwide registry in Japan. Outcome measures included periprocedural outcomes, including technical failure and POCs. To compare outcomes with and without IVUS use, propensity score matching analysis was performed for overall and for each arterial region (aortoiliac [AI], femoropopliteal [FP], and infrapopliteal [IP] arteries) using a binary logistic regression model. RESULTS: IVUS was used in 75%, 72%, and 37% of AI, FP, and IP lesions, respectively. After propensity matching extraction, the IVUS group had a tendency of lower technical failure rate than the non-IVUS group, although not statistically different (3.9% vs. 5.4%, p = 0.054), without an increase in the POC rate (1.8% vs. 1.6%, p = 0.54). Regarding the per-regional analysis, the technical failure rate of FP-EVT was significantly lower in the IVUS group (3.1% vs. 4.2%, p = 0.006), whereas those of AI-EVT (2.2% vs. 3.1%, p = 0.12) and IP-EVT (6.8% vs. 6.1%, p = 0.37) were not significantly different between the two groups. Furthermore, IVUS did not increase the POC rate for any region (AI-EVT: 1.3% vs. 1.3%, p = 1.00; FP-EVT: 1.8% vs. 1.7%, p = 0.75; and IP-EVT: 2.0% vs. 1.7%, p = 0.56). CONCLUSION: The current study revealed that IVUS did not increase the POCs and technical failure for overall lesions but reduced the incidence of FP-EVT technical failure.

4.
Clin Cardiol ; 47(6): e24310, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38888132

RESUMO

BACKGROUNDS: Lead dislodgement is a severe complication in cardiac implantable electronic device (CIED) implantation. Inflammation after CIED implantation results in the development of adhesions between lead and tissues, resulting in the lead becoming fixed in the body. In patients with immunosuppressive therapy, however, adhesion is inhibited by anti-inflammatory effects. However, the association between lead dislodgement and immunosuppressive therapy has not been clarified. The purpose of this study was to investigate the association between lead dislodgement and immunosuppressive therapy. HYPOTHESIS: We hypothesized that lead dislodgement more frequently occur in patients with immunosuppressive therapy than those without. METHODS: In total, 651 consecutive patients who underwent CIED implantation or lead addition (age, 76 ± 11 years; and males, 374 [58%], high voltage device, 121 [19%], lead addition 23 [4%]) were retrospectively enrolled. Immunosuppressive therapy was with regular steroids or immunosuppressants. Lead placement was guided by fluoroscopy, and active fixation leads were used. Restraint of the upper limb by chest tape was performed for 1 week after the procedure. Lead dislodgement was defined as a change in lead position and/or lead failure requiring reoperation. RESULTS: Twenty (3.1%) patients received immunosuppressive therapy. Among these, 15 (2.3%) patients regularly took steroids and 8 (1.2%) took immunosuppressants. Lead dislodgement occurred in 10 (1.5%) patients. Lead dislodgement was more frequent in patients with immunosuppressive therapy than in those without (3 [15%] vs. 7 [1%], p = 0.003). CONCLUSION: In patients with CIED implantation or lead addition, lead dislodgement is more frequent in patients with immunosuppressive therapy than in those without.


Assuntos
Desfibriladores Implantáveis , Imunossupressores , Marca-Passo Artificial , Humanos , Masculino , Feminino , Idoso , Estudos Retrospectivos , Imunossupressores/efeitos adversos , Imunossupressores/uso terapêutico , Idoso de 80 Anos ou mais , Fatores de Risco , Resultado do Tratamento , Pessoa de Meia-Idade , Remoção de Dispositivo , Dispositivos de Terapia de Ressincronização Cardíaca
5.
JACC Cardiovasc Interv ; 17(13): 1547-1556, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38842992

RESUMO

BACKGROUND: Sirolimus-coated balloons (SCB) for the treatment of femoropopliteal (FP) lesions have not been systematically studied, but initial outcomes from early studies are promising. OBJECTIVES: The authors sought to evaluate the safety and efficacy of the SELUTION SLR SCB, composed of proprietary microreservoir technology combining sirolimus and biodegradable polymer, when used to treat mild-to-moderate FP disease in a Japanese population. METHODS: This multicenter, prospective, single-arm study (SELUTION SFA JAPAN) enrolled 134 patients with FP disease. It was independently adjudicated by an imaging core laboratory and clinical events committee. The primary endpoint was 12-month primary patency, defined as peak systolic velocity ratio ≥2.5 by duplex ultrasound and compared against a prespecified performance goal of 60% based on established angioplasty data. RESULTS: The mean age was 73.8 ± 6.9 years, and 60.3% of patients had diabetes mellitus. The mean lesion length was 127.4 ± 59.7 mm, 17.2% were chronic total occlusions, and 47.8% involved the popliteal artery. Data on 12-month restenosis were available in 127 patients (94.8%). The 12-month primary patency rate was 87.9%, and the freedom from clinically driven target lesion revascularization (CD-TLR) was 97.0% per Kaplan-Meier estimate. The major adverse event rate was 6.7%, driven by 4 CD-TLRs and 5 deaths, none of which were related to the device or procedure. Ankle-brachial index data improved significantly from 0.73 ± 0.16 at baseline to 0.96 ± 0.14 at 30 days postprocedure and was sustained through 12 months (0.94 ± 0.13). CONCLUSIONS: The SELUTION SFA JAPAN trial demonstrated that a novel SELUTION SCB is a safe and effective treatment option for FP disease in symptomatic patients.


Assuntos
Angioplastia com Balão , Fármacos Cardiovasculares , Materiais Revestidos Biocompatíveis , Artéria Femoral , Doença Arterial Periférica , Artéria Poplítea , Sirolimo , Dispositivos de Acesso Vascular , Grau de Desobstrução Vascular , Humanos , Artéria Poplítea/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Idoso , Masculino , Feminino , Artéria Femoral/fisiopatologia , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/terapia , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/diagnóstico por imagem , Estudos Prospectivos , Japão , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Fatores de Tempo , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Idoso de 80 Anos ou mais , Recidiva , Resultado do Tratamento , Desenho de Equipamento , Fatores de Risco , Pessoa de Meia-Idade
6.
ESC Heart Fail ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38853626

RESUMO

AIMS: Atrial fibrillation (AF) and heart failure (HF) affect each other and are often co-morbid. The fact that HF development is not uncommon even after ablation suggests that we need a deeper understanding of the pathology of these conditions. Atrial myocardial degeneration is an underlying factor in AF patients and may be associated with HF development after ablation. This study aimed to investigate the impact of low-voltage areas (LVAs) on HF prognosis after AF ablation. METHODS AND RESULTS: This observational study included 1481 consecutive patients undergoing initial ablation for AF. Left atrial LVAs were defined as regions with a bipolar peak-to-peak voltage of <0.50 mV. Patients were divided into three groups: no LVA (LVA size indexed to body surface area <3 cm2/m2, n = 1129), small LVA (3-10 cm2/m2, n = 217), and extensive LVA (≥10 cm2/m2, n = 135). A composite endpoint of HF hospitalization or death occurred more frequently in patients with larger LVAs (3.3% vs. 6.5% vs. 13.3%, P < 0.0001) during the 3-year follow up period. The extent of LVAs was independently related to the risk of the composite endpoint with an adjusted hazard ratio of 1.55 (95% confidence interval, 1.16-2.10) for each additional step of LVA classification (P = 0.003). CONCLUSIONS: LVA presence and its extent were associated with frequent HF hospitalization and death. Underlying atrial myopathy appears to define a poor HF prognosis after AF ablation.

7.
Cardiovasc Intervent Radiol ; 47(6): 730-740, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38816504

RESUMO

PURPOSE: In the present trial, the 24-month safety and effectiveness of the TCD-17187 drug-coated balloon (DCB) for the treatment of atherosclerotic lesions in the superficial femoral artery (SFA) and proximal popliteal artery (PA) were evaluated in Japanese patients. METHODS: This was a prospective, multicenter, core laboratory-adjudicated, single-arm trial. From 2019 to 2020, 121 patients with symptomatic peripheral artery disease were enrolled. The primary effectiveness outcome measure was primary patency. The safety outcome measure was the major adverse event (MAE) rate. RESULTS: Age was 74.5 ± 7.3 years, and diabetes mellitus was present in 67.5%. Lesion length and reference vessel diameter (RVD) were 106.0 ± 52.6 mm and 5.2 ± 0.8 mm, respectively. Chronic total occlusion (CTO) and bilateral calcification rate (Grade 3 and 4 by peripheral arterial calcium scoring system (PACSS)) were 17.5% and 50.8%, respectively. The 24-month primary patency rate by duplex ultrasound was 71.3%, while freedom from clinically driven target lesion revascularization (CD-TLR) was 87.0%. The MAE rate was 13.2% and all events consisted of CD-TLR. There were no instances of device- or procedure-related deaths major amputations throughout the 24 months. Multivariate Cox proportional hazards regression analysis revealed significant differences associated with loss of primary patency in the following characteristics: CTO, restenotic lesion and RVD. CONCLUSION: This trial confirmed the safety and effectiveness of TCD-17187 DCB for atherosclerotic lesions of the SFA and/or proximal PA for up to 24 months. LEVEL OF EVIDENCE: Level 3, Cohort study. CLINICAL TRIAL REGISTRATION: URL: https://center6.umin.ac.jp/cgi-open-bin/ctr/ctr.cgi?function=brows&action=brows&recptno=R000038612&type=summary&language=J:Registration ID: UMIN000034122. Registration Date: September 13, 2018.


Assuntos
Angioplastia com Balão , Materiais Revestidos Biocompatíveis , Artéria Femoral , Doença Arterial Periférica , Artéria Poplítea , Grau de Desobstrução Vascular , Humanos , Masculino , Artéria Poplítea/diagnóstico por imagem , Feminino , Idoso , Artéria Femoral/diagnóstico por imagem , Estudos Prospectivos , Doença Arterial Periférica/terapia , Doença Arterial Periférica/diagnóstico por imagem , Angioplastia com Balão/métodos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Japão
8.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38767127

RESUMO

AIMS: Understanding of the tissue cooling properties of cryoballoon ablation during pulmonary vein (PV) isolation is lacking. The purpose of this study was to delineate the depth of the tissue cooling effect during cryoballoon freezing at the pulmonary venous ostium. METHODS AND RESULTS: A left atrial-PV model was constructed using a three-dimensional printer with data from a patient to which porcine thigh muscle of various thicknesses could be affixed. The model was placed in a 37°C water tank with a PV water flow at a rate that mimicked biological blood flow. Cryofreezing at the PV ostium was performed five times each for sliced porcine thigh muscle of 2, 4, and 6 mm thickness, and sliced muscle cooling on the side opposite the balloon was monitored. The cooling effect was assessed using the average temperature of 12 evenly distributed thermocouples covering the roof region of the left superior PV. Tissue cooling effects were in the order of the 2, 4, and 6 mm thicknesses, with an average temperature of -41.4 ± 4.2°C for 2 mm, -33.0 ± 4.0°C for 4 mm, and 8.0 ± 8.7°C for 6 mm at 180 s (P for trend <0.0001). In addition, tissue temperature drops were steeper in thin muscle (maximum temperature drop per 5 s: 5.2 ± 0.9°C, 3.9 ± 0.7°C, and 1.3 ± 0.7°C, P for trend <0.0001). CONCLUSION: The cooling effect of cryoballoon freezing is weaker in the deeper layers. Cryoballoon ablation should be performed with consideration to myocardial thickness.


Assuntos
Criocirurgia , Veias Pulmonares , Criocirurgia/métodos , Criocirurgia/instrumentação , Criocirurgia/efeitos adversos , Animais , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Suínos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Humanos , Modelos Cardiovasculares , Músculo Esquelético/cirurgia , Modelos Anatômicos
9.
J Cardiol ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38641319

RESUMO

BACKGROUND: The relationship between baseline yellow plaque (YP) and vascular response after stent implantation has not been fully investigated. METHODS: This was a sub-analysis of the Collaboration-1 study (multicenter, retrospective, observational study). A total of 88 lesions from 80 patients with chronic coronary syndrome who underwent percutaneous coronary intervention were analyzed. Optical coherence tomography (OCT) and coronary angioscopy (CAS) were serially performed immediately and 11 months after stent implantation. YP was defined as the stented segment with yellow or intensive yellow color assessed by CAS. Neoatherosclerosis was defined as a lipid or calcified neointima assessed by OCT. OCT and CAS findings at 11 months were compared between lesions with baseline YP (YP group) and lesions without baseline YP (Non-YP group). RESULTS: Baseline YP was detected in 37 lesions (42 %). OCT findings at 11 months showed that the incidence of neoatherosclerosis was significantly higher in the YP group (11 % versus 0 %, p = 0.028) and mean neointimal thickness tended to be lower (104 ±â€¯43 µm versus 120 ±â€¯48 µm, p = 0.098). CAS findings at 11 months demonstrated that the dominant and minimum neointimal coverage grades were significantly lower (p = 0.049 and P = 0.026) and maximum yellow color grade was significantly higher (p < 0.001) in the YP group. CONCLUSIONS: Baseline YP affected the incidence of neoatherosclerosis as well as poor neointimal coverage at 11 months after stent implantation.

10.
Am J Cardiol ; 218: 43-50, 2024 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-38479607

RESUMO

Low-voltage areas have been used as atrial structural substrates in estimating fibrotic degeneration in patients with atrial fibrillation (AF). The high-resolution maps obtained by recently developed mapping catheters allow the visualization of several functional abnormalities. We investigated the association between left atrial (LA) functional abnormal findings on a high-resolution substrate map and AF recurrence in patients who underwent pulmonary vein isolation without any additional LA substrate ablation. This observational study included 100 consecutive patients who underwent second ablation for AF (paroxysmal, 48%; persistent, 52%). Patients with extra-pulmonary-vein LA substrate ablation during the initial and second ablation were excluded. LA mapping was performed using a 64-pole mini-basket catheter on the RHYTHMIA mapping system (Boston Scientific, Marlborough [Cambridge] Massachusetts). Patients were followed for 2 years. AF recurrence developed in 39 (39%) patients. On the high-resolution substrate map, AF recurrence was associated with the presence of the following findings: low-voltage areas (<1.0 mV, >5 cm2; hazard ratio [HR] = 2.53; 95% confidence interval [CI] = 1.30 to 4.93; p <0.006), fractionated-electrogram areas (≥5 peaks, >5 cm2; HR = 2.15, 95% CI = 1.10 to 4.19; p = 0.025), LA conduction time of >130 ms (HR = 3.11, 95% CI = 1.65 to 5.88, p <0.0001), deceleration zone (≥5 isochrones/cm2; HR = 1.97, 95% CI = 1.04 to 3.37, p = 0.039), and multiple septal break-out points (HR = 3.27, 95% CI = 1.50 to 7.16, p = 0.003). Accumulation of these risk factors increased AF recurrence in a stepwise manner, with an HR = 1.90, 95% CI = 1.44 to 2.52, p <0.00001 for each additional risk factor. In conclusion, a high-resolution map revealed new LA functional substrates associated with AF recurrence. Implementation of functional substrates may improve the prediction of AF recurrence after ablation, and possibly aid the development of tailored AF ablation strategies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Átrios do Coração , Frequência Cardíaca , Veias Pulmonares/cirurgia , Recidiva , Fatores de Risco , Resultado do Tratamento
11.
Vasc Med ; 29(2): 182-188, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38457137

RESUMO

BACKGROUND: Although the 1-year clinical outcomes of fluoropolymer-based drug-eluting stents (FP-DES) were favorable for the treatment of real-world femoropopliteal lesions in symptomatic peripheral artery disease (PAD), their performance beyond 1 year remained unknown. The current study determined the 3-year clinical course of FP-DES implantation for real-world femoropopliteal lesions. METHODS: This multicenter, prospective, observational study evaluated 1204 limbs (chronic limb-threatening ischemia, 34.8%; mean lesion length, 18.6 ± 9.9 cm, chronic total occlusion: 53.2%) of 1097 patients with PAD (age, 75 ± 9 years; diabetes mellitus, 60.8%) undergoing FP-DES implantation for femoropopliteal lesions. The primary outcome measure was 3-year restenosis. The secondary outcome measures included 3-year occlusive restenosis, stent thrombosis, target lesion revascularization (TLR), and aneurysmal degeneration. RESULTS: The 3-year cumulative occurrence of restenosis was 27.3%, whereas that of occlusive restenosis, stent thrombosis, and TLR was 16.1%, 7.3%, and 19.6%, respectively. The annual occurrence of restenosis decreased by 12.0%, 9.5%, and 5.8% in the first, second, and third year, respectively (p < 0.001). Similarly, the rates of occlusive restenosis and stent thrombosis decreased (p < 0.001 and p = 0.007, respectively), whereas the rate of TLR remained unchanged for 3 years (p = 0.15). The incidence of aneurysmal degeneration at 3 years (15.7%) did not significantly differ from that at 1 and 2 years (p = 0.69 and 0.20, respectively). CONCLUSIONS: This study highlights the favorable long-term clinical course of FP-DES in real-world practice, emphasizing the importance of monitoring for occlusive restenosis and stent thrombosis while considering the potential onset of aneurysmal degeneration.


Assuntos
Stents Farmacológicos , Doença Arterial Periférica , Trombose , Humanos , Idoso , Idoso de 80 Anos ou mais , Artéria Femoral/diagnóstico por imagem , Artéria Poplítea/diagnóstico por imagem , Polímeros de Fluorcarboneto , Resultado do Tratamento , Estudos Prospectivos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Progressão da Doença , Grau de Desobstrução Vascular , Desenho de Prótese
12.
Circ Rep ; 6(2): 19-27, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38344391

RESUMO

Background: The relationship between sex differences and long-term outcomes after fractional flow reserve (FFR)- and instantaneous wave-free ratio (iFR)-guided deferral of revascularization has yet to be elucidated. Methods and Results: From the J-CONFIRM registry (long-term outcomes of Japanese patients with deferral of coronary intervention based on FFR in a multicenter registry), this study included 432 lesions from 385 patients (men, 323 lesions in 286 patients; women, 109 lesions in 99 patients) with paired data of FFR and iFR. The primary endpoint was the cumulative 5-year incidence of target vessel failure (TVF), including cardiac death, target vessel-related myocardial infarction, and clinically driven target vessel revascularization. The median FFR value was lower in men than in women (0.85 [0.81, 0.88] vs. 0.87 [0.83, 0.91], P=0.002), but the iFR value was comparable between men and women (0.94 [0.90, 0.98] vs. 0.93 [0.89, 0.98], P=0.26). The frequency of discordance between FFR and iFR was comparable between men and women (19.5% vs. 23.9%, P=0.34), although with different discordance patterns (P=0.036). The cumulative incidence of 5-year TVF did not differ between men and women after adjustment for baseline characteristics (13.9% vs. 6.9%, adjusted hazard ratio 1.82 [95% confidence interval: 0.44-7.56]; P=0.41). Conclusions: Despite sex differences in the results for physiological indexes, the 5-year TVF in deferred lesions did not differ between men and women after adjustment for baseline characteristics.

13.
J Cardiovasc Electrophysiol ; 35(4): 775-784, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38375957

RESUMO

INTRODUCTION: Left atrial low-voltage areas (LVAs) are known to be correlated with atrial scarring and atrial fibrillation (AF) recurrence after ablation. However, the association between LVAs and glycemic status before ablation has not been fully clarified. The purpose of this study was to investigate associations among the prevalence of diabetes mellitus (DM), glycemic control, and the prevalence of LVAs in patients with AF ablation. METHODS: In total, 912 (age, 68 ± 10 years; female, 299 [33%]; persistent AF, 513 [56%]) consecutive patients who underwent initial AF ablation were included. A preprocedure glycated hemoglobin A1c (HbA1c) ≥7% was set as the cutoff for poor glycemic control in patients with DM. LVAs were defined as areas with a bipolar voltage of <0.5 mV covering ≥5 cm2 of left atrium. RESULTS: LVAs existed in 208 (23%) patients, and 168 (18%) patients had DM. LVAs were found more frequently in patients with DM and poor glycemic control. On multivariate analysis, DM with HbA1c ≥7% was an independent predictor of LVAs (odds ratio, 3.3; 95% confidence interval: 1.6-6.7; p = .001). In patients with LVAs, freedom from AF recurrence during the 24-month study period was significantly lower in patients who had DM with HbA1c ≥7% than in those without DM (37.9% vs. 54.7%, p = .02). CONCLUSION: In patients with AF ablation, LVAs were found more frequently in patients with DM and poor glycemic control. DM with HbA1c ≥7% was an independent predictor of LVAs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Diabetes Mellitus , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Prevalência , Hemoglobinas Glicadas , Controle Glicêmico , Átrios do Coração/cirurgia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva , Resultado do Tratamento
15.
J Vasc Interv Radiol ; 35(2): 259-268, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37898458

RESUMO

PURPOSE: To investigate the impact of compliance with recommended procedural techniques on the midterm patency of a fluoropolymer-based drug-eluting stent (FP-DES) in the femoropopliteal artery. MATERIALS AND METHODS: This retrospective study included 200 femoropopliteal lesions (chronic limb-threatening ischemia, 59%; chronic total occlusion, 41%) in 173 patients (male, 66%; diabetes mellitus, 62%; hemodialysis, 40%) with lower extremity arterial disease who underwent intravascular ultrasound (IVUS)-guided endovascular therapy with FP-DES between January 2016 and July 2021. The primary outcome measure was restenosis, defined as a peak systolic velocity ratio of >2.4 based on the duplex US findings. The association between procedural techniques and incidence of restenosis was investigated using Cox proportional hazards regression models. RESULTS: The 2-year cumulative incidence of restenosis was 19.5% (SD ± 3.3). Multivariate analysis revealed that noncompliance with recommended procedural techniques, such as plaque burden at the stent edge of <50%, a minimum stent area (MSA) of >12 mm2, and stent placement within the P1 segment, was independently associated with an increased risk of restenosis (hazard ratios [HRs], 3.22, 4.71, and 4.67 and P = .004, P < .001, and P < .001, respectively). The 2-year restenosis risk for procedures performed in compliance with all 3-technical criteria was 8.4% (SD ± 3.4), whereas the risks for those in compliance with 2-technical criteria or 0- or 1-technical criteria were 25.0% (SD ± 6.2) and 48.6% (SD ± 10.4), respectively. HRs relative to 3-technical criteria compliance were 3.79 (P = .007) and 11.85 (P < .001), respectively. CONCLUSIONS: Noncompliance with recommended procedural techniques, including plaque burden at the stent edge of <50%, MSA of >12 mm2, and stent placement within the P1 segment, was significantly associated with an increased risk of 2-year restenosis after FP-DES implantation in the femoropopliteal artery.


Assuntos
Stents Farmacológicos , Doença Arterial Periférica , Humanos , Masculino , Artéria Femoral/diagnóstico por imagem , Artéria Poplítea/diagnóstico por imagem , Polímeros de Fluorcarboneto , Estudos Retrospectivos , Resultado do Tratamento , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Grau de Desobstrução Vascular , Desenho de Prótese
17.
J Cardiovasc Electrophysiol ; 35(1): 171-181, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38018401

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is accompanied by various types of remodeling, including volumetric enlargement and histological degeneration. Electrical remodeling reportedly reflects histological degeneration. PURPOSE: To clarify the differences in determinants and clinical impacts among types of remodeling. METHODS: This observational study included 1118 consecutive patients undergoing initial ablation for AF. Patients were divided into four groups: minimal remodeling (left atrial volume index [LAVI] < mean value and no low-voltage area [LVA], n = 477); volumetric remodeling (LAVI ≥ mean value and no LVA, n = 361); electrical remodeling (LAVI < mean value and LVA presence, n = 96); and combined remodeling (LAVI ≥ mean value and LVA presence, n = 184). AF recurrence and other clinical outcomes were followed up for 2 and 5 years, respectively. RESULTS: Major determinants of each remodeling pattern were high age for electrical (odds ratio = 2.32, 95% confidence interval = 1.68-3.25) and combined remodeling (2.57, 1.88-3.49); female for electrical (3.85, 2.21-6.71) and combined remodeling (4.92, 2.90-8.25); persistent AF for combined remodeling (7.09, 3.75-13.4); and heart failure for volumetric (1.71, 1.51-2.53) and combined remodeling (2.21, 1.30-3.75). Recurrence rate after initial ablation increased in the order of minimal remodeling (20.1%), volumetric (27.4%) or electrical remodeling (36.5%), and combined remodeling (50.0%, p < .0001). A composite endpoint of heart failure, stroke, and death occurred in the order of minimal (3.4%), volumetric (7.5%) or electrical (8.3%), and combined remodeling (15.2%, p < .0001). CONCLUSION: Volumetric, electrical, and combined remodeling were each associated with a unique patient background, and defined rhythm and other clinical outcomes.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Remodelamento Atrial , Insuficiência Cardíaca , Feminino , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Recidiva , Resultado do Tratamento , Masculino
18.
Pacing Clin Electrophysiol ; 47(1): 28-35, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38029377

RESUMO

BACKGROUND: Recently, a new OCTARAY® mapping catheter was commercially launched. The catheter is designed to enable high-density mapping and precise signal recording via 48 small electrodes arranged on eight radiating splines. The purpose of this study was to compare bipolar voltage and low-voltage-area size, and mapping efficacy between the OCTARAY catheter and the PENTARAY® catheter METHODS: Twelve consecutive patients who underwent initial and second ablations for persistent atrial fibrillation within 2 years were considered for enrollment. Voltage mapping was performed twice, first during the initial ablation using the PENTARY catheter and second during the second ablation using the OCTARAY Long 3-3-3-3-3 (L3) catheter. RESULTS: Mean voltage with the OCTARAY-L3 catheter (1.64 ± 0.57 mV) was 32.3% greater than that with the PENTARAY catheter (1.24 ± 0.46 mV, p < .0001) in total left atrium. Low-voltage-area (<0.50 mV) size with the OCTARAY-L3 catheter was smaller than that with the PENTARAY catheter (6.9 ± 9.7 vs. 11.4 ± 13.0 cm2 , p < .0001). The OCTARAY-L3 catheter demonstrated greater efficacy than the PENTARAY catheter in terms of shorter mapping time (606 ± 99 vs. 782 ± 211 s, p = .008) and more mapping points (3,026 ± 838 vs. 781 ± 342 points, p < .0001). CONCLUSION: The OCTARAY catheter demonstrated higher voltage recordings, narrower low-voltage areas, and a more efficacious mapping procedure than the PENTARAY catheter.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Técnicas Eletrofisiológicas Cardíacas , Ablação por Cateter/métodos , Fibrilação Atrial/cirurgia , Átrios do Coração , Catéteres
19.
Int J Cardiol ; 399: 131686, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38151161

RESUMO

BACKGROUND: There are little clinical data on imaging-guided percutaneous coronary intervention (PCI) 1 year after the biodegradable-polymer sirolimus-eluting stents (BP-SES) implantation, when the polymer disappears. METHODS: We retrospectively analyzed 2455 patients who underwent successful PCI with BP-SES or durable-polymer everolimus-eluting stents (DP-EES) between September 2011 and March 2021, and compared 2-year clinical outcomes of BP-SES (n = 459) with DP-EES (n = 1996). The outcome measures were target lesion revascularization (TLR) and major adverse cardiac events (MACE), defined as a composite of cardiac death, myocardial infarction, target vessel revascularization, and stent thrombosis. Multivariate analysis using the Cox proportional hazard model and inverse probability weighting (IPW) analysis based on the propensity score were used to evaluate the clinical outcomes. RESULTS: The 2-year cumulative incidences of TLR (BP-SES: 4.9% vs. DP-SES: 6.1%, p = 0.304) and MACE (10.3% vs. 12.5%, p = 0.159) were similar between the two groups. Multivariable and IPW analysis revealed the risks of TLR (p = 0.388 and p = 0.500) and MACE (p = 0.139 and p = 0.083) also had no significant difference. There was a significant interaction between none/mild and moderate/severe calcification with respect to MACE and TLR (adjusted p for interaction = 0.036 and 0.047, respectively). The risk of MACE was significantly lower in BP-SES than in DP-EES in lesions with none/mild calcification (adjusted hazard ratio [aHR]: 0.53; 95% confidence interval [CI]: 0.30-0.91), while it was similar in those with moderate/severe calcification (aHR: 0.95; 95% CI: 0.58-1.55). CONCLUSIONS: Compared with DP-EES, BP-SES demonstrated durable 2-year clinical outcomes. However, BP-SES showed better clinical performance than DP-EES for lesions with none/mild calcification.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Sirolimo/farmacologia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Everolimo , Polímeros , Implantes Absorvíveis , Desenho de Prótese , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia
20.
Heart Rhythm ; 21(4): 378-386, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38157922

RESUMO

BACKGROUND: Atrial cardiomyopathy is known as an underlying pathophysiological factor in the majority of patients with atrial fibrillation (AF). Left atrial low-voltage areas (LVAs) are reported to coincide with fibrosis and likely represent atrial cardiomyopathy. OBJECTIVE: The purpose of this study was to delineate differences in the long-term prognosis of patients stratified by the size of LVAs. METHODS: This observational study included 1488 consecutive patients undergoing initial ablation for AF. LVAs were defined as regions with a bipolar peak-to-peak voltage <0.50 mV. The total study population was divided into 3 groups stratified by LVA size: patients with no LVAs (n = 1136); those with small (<20 cm2) LVAs (n = 250) LVAs; and those with extensive (≥20 cm2) LVAs (n = 102). Composite endpoints of death, heart failure, and stroke were followed for up to 5 years. RESULTS: Composite endpoints developed in 105 of 1488 patients (7.1%), and AF recurrence occurred in 410 (27.6%). Composite endpoints developed more frequently in the order of patients with extensive LVAs (19.1%), small LVAs (10.8%), and no LVAs (5.1%) (P for trend <.0001). Multivariable analysis revealed that LVA presence was independently associated with higher incidence of composite endpoints, irrespective of AF recurrence (modified hazard ratio 1.73; 95% confidence interval 1.13-2.64; P = .011) CONCLUSION: LVA presence and its extent both were associated with poor long-term composite endpoints of death, heart failure, and stroke, irrespective of AF recurrence or other confounders. Underlying atrial cardiomyopathy seems to define a poor prognosis after AF ablation.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Insuficiência Cardíaca , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Prognóstico , Seguimentos , Átrios do Coração , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Ablação por Cateter/efeitos adversos , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...