1.
Access Microbiol ; 5(8)2023.
Artigo em Inglês | MEDLINE | ID: mdl-37691837

RESUMO

Introduction: Kingella kingae is a Gram-negative micro-organism that is rarely isolated as a pathogen in the adult population. Although widely reported to affect prosthetic heart valves, there have been no previously reported cases of K. kingae infecting prosthetic joints in adults. Case Presentation: A 61-year-old patient with a history of rheumatoid arthritis presented with insidious onset of pain and swelling in her right shoulder, which had progressed to a discharging sinus. The patient had undergone a total shoulder replacement 11 years previously and had not developed any prior post-operative infections. She had been taking anti-TNF medication for 5 years prior to review for her rheumatoid disease. The patient underwent a two-stage revision replacement procedure, including implant removal, sinus excision and debridement. Deep tissue samples grew K. kingae post-operatively. The patient was commenced on intravenous ceftriaxone for 14 days, followed by a further 28 days of oral ciprofloxacin. A second-stage custom shoulder replacement was undertaken 10 months following the first stage and the patient made a good functional recovery. Conclusion: The authors suggest that clinicians should be attuned to K. kingae as a potential pathogen for prosthetic joint infection, particularly in patients who are immunosuppressed. Two-stage revision procedures can ensure a favourable outcome and eradication of this pathogen from the joint. Beta lactams remain the principal antibiotic of choice.

2.
Clin Med (Lond) ; 23(1): 24-30, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36697010

RESUMO

BACKGROUND: Healthcare workers (HCWs) are at increased risk of coronavirus 2019 (COVID-19) infection. Personal protective equipment (PPE) and infection control guidelines help limit transmission. However, poor confidence leads to higher levels of anxiety rates and infection. We assessed knowledge and confidence in PPE among HCWs and associated anxiety. METHODS: A cross-sectional, multi-centre survey using a validated questionnaire assessing actual and self-perceived knowledge on PPE was distributed among HCWs across the UK. Confidence in PPE and levels of anxiety were assessed using the General Anxiety Disorder-7 (GAD-7) tool. RESULTS: In total, 1,055 responses were received; 99% had familiarity with PPE guidance; however, only 15% correctly answered questions on PPE guidance; 86% and 80% had received mask-fitting and donning-doffing training, respectively; 33% indicated poor/very poor hospital communication. Confidence and anxiety were related to: profession; comorbidities; self-perceived knowledge; and PPE training and communication. CONCLUSION: Confidence in PPE was poor and anxiety was related to inadequate information and training. Thus, improved communication is required for effective response to subsequent COVID-19 waves and similar pandemics.


Assuntos
COVID-19 , Dispositivos de Proteção Respiratória , Humanos , Pandemias/prevenção & controle , Estudos Transversais , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Equipamento de Proteção Individual , Pessoal de Saúde/educação , Ansiedade , Reino Unido/epidemiologia
3.
Shoulder Elbow ; 13(6): 656-670, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34804215

RESUMO

BACKGROUND: Tumour resection followed by joint reconstruction is a surgical option in the appropriate patient. The evidence for such reconstructive surgery of the elbow joint is limited. The aim of this study is to review the literature to evaluate the outcomes of joint replacement surgery in tumours of the elbow. METHODS: A systematic review of PUBMED and EMBASE databases was conducted. Case series and comparative studies reporting results after total elbow arthroplasty, modular endo-prosthetic replacement and custom prosthesis were eligible for inclusion. RESULTS: Eleven eligible studies were identified (n = 134). At mean follow-up of 44 months, the overall revision rate was 14% and complication rate was 28%. The mean Mayo Elbow Performance Score was 75, with 56% of patients reporting good or excellent outcomes. The mean post-operative range of motion was 97°. DISCUSSION: Elbow prosthesis reconstruction after tumour resection can provide good functional outcomes at mid-term follow-up. The complication and revision rates are comparable to other indications for elbow replacement surgery. Further prospective studies are required to compare outcomes between different elbow arthroplasty options after tumour resection.

4.
Shoulder Elbow ; 12(5): 353-361, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33093874

RESUMO

BACKGROUND: Total elbow arthroplasty (TEA) is the established treatment for end-stage rheumatoid arthritis but improved surgical techniques have resulted in expanded indications. The aim of this study is to review the literature to evaluate the evolution of surgical indications for TEA. METHODS: A systematic review of PubMed and EMBASE databases was conducted. Case series and comparative studies reporting results after three types of primary TEA were eligible for inclusion. RESULTS: Forty-nine eligible studies were identified (n = 1995). The number of TEA cases published annually increased from 6 cases in 1980 to 135 cases in 2008. The commonest indication for TEA throughout the review period was rheumatoid arthritis but its annual proportion reduced from 77% to 50%. The mean Mayo Elbow Performance Score significantly improved for all indications. Three comparative studies reported statistically improved functional outcomes in rheumatoid arthritis over the trauma sequelae group. Complication and revision rates varied; rheumatoid arthritis 5.2-30.9% and 11-13%, acute fracture 0-50% and 10-11%, trauma sequelae 14.2-50% and 0-30%, osteoarthritis 50% and 11%, respectively. DISCUSSION: TEA can provide functional improvements in inflammatory arthritis, acute fractures, trauma sequelae and miscellaneous indications. Long-term TEA survivorship appears satisfactory in rheumatoid arthritis and fracture cases; however, further research into alternative surgical indications is still required.

5.
J Orthop ; 15(2): 549-552, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29881191

RESUMO

This laboratory-based study compared distal fibula simple oblique fracture fixation with one-third tubular plate with and without a single lag screw to determine which was mechanically more stable. A control group fixed with a limited contact dynamic compression plate was also tested. Biomechanical testing of 30 osteotomised saw bones under lateral bending and torsional forces was performed. There was no significant difference between the mean lateral bending and mean torsional stiffness between the fixation with tubular plate and lag screw and tubular plate alone. Limited contact dynamic compression plate conferred the best stability in lateral bending and torsion, as expected.

6.
Hip Int ; 28(1): 50-52, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28885647

RESUMO

INTRODUCTION: Recent controversies surrounding metal-on-metal (MoM) hip resurfacing has led to a substantial decline in its use. Despite this, there is good evidence to support the use of specific implants in select patients. PATIENTS AND METHODS: A retrospective analysis of Birmingham Hip Resurfacing (BHR) patients with a minimum of 10 years follow-up was performed. Functional scoring was performed with the Oxford Hip Score (OHS) and failure was defined as revision for any cause. 111 patients underwent 121 BHR procedures. All patients had a minimum follow-up of 10 years. 70 patients (63%) were male. Mean patient age at surgery was 52.5 years (male 53.9 years, female 48.8 years). RESULTS: Overall survival at 10 years was 91% (97% male, 80% female). There was a statistically significant improvement in OHS postoperatively which remains at 10-year follow-up (p = <0.05). There was no significant difference in scores between the male and female groups. Revisions were most often in patients with smaller component sizes but this was not found to be statistically significant. CONCLUSIONS: Our results reflect that of the wider literature in that good outcomes can be obtained with this implant in a select group of patients and results are comparable to that of conventional hip arthroplasty in patients of a similar age.


Assuntos
Artroplastia de Quadril/instrumentação , Articulação do Quadril , Prótese de Quadril , Artropatias/cirurgia , Próteses Articulares Metal-Metal , Adulto , Idoso , Feminino , Humanos , Artropatias/etiologia , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
7.
J Orthop Traumatol ; 17(2): 149-53, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26206329

RESUMO

BACKGROUND: Metal-on-metal total hip replacements (THRs) with large femoral heads have been associated with elevated levels of cobalt (Co) and chromium (Cr), which have been attributed to high levels of wear at the articular surface. Our unit recently published data showing a significant increase in the mean levels of Co ions in patients with a 36-mm diameter femoral head with the metal-on-polyethylene Trident-Accolade system. The aim of this study is to assess the levels of Co and Cr in the Exeter-Trident hybrid system, as similar findings would raise concern over the V40 taper trunnion. MATERIALS AND METHODS: The study included 83 patients (45 male and 38 female with a mean age of 75.6 years) who received Exeter-Trident hybrid metal-on-polyethylene THRs. The patients were then divided into two groups according to the diameter of the femoral head used-38 patients in the 28-mm group (control), and 45 in the 36-mm (experimental) group. Serum levels of blood Co and Cr were analysed for all recruited patients. RESULTS: In the control group (28-mm femoral head) all Co and Cr values were normal (under the abnormal threshold), as were the experimental group (36-mm femoral head). The data values were below <10 nmol and <40 nmol for Co and Cr, respectively. CONCLUSION: Since the National Joint Registry (NJR) states that the Exeter femoral stem is the commonest cemented femoral stem prosthesis used in the UK, we found it imperative that these results are documented given the corresponding findings in the Trident-Accolade system in our previous study. This study provides relative reassurance that the issue does not lie with the V40 taper trunnion, but raises suspicion that the issue may be with the titanium Accolade stem with large diameter femoral heads.


Assuntos
Artroplastia de Quadril/instrumentação , Cromo/sangue , Cobalto/sangue , Prótese de Quadril , Idoso , Inglaterra , Feminino , Cabeça do Fêmur/patologia , Humanos , Íons , Masculino , Polietileno , Desenho de Prótese
8.
BMJ Case Rep ; 20142014 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-24895390

RESUMO

The anatomy of the shoulder joint comprises a relatively large humeral head with a shallow glenoid cavity allowing a remarkable range of motion at the expense of inherent instability. Despite anterior shoulder dislocations being the most common type encountered, bilateral dislocations are rare and almost always posterior. The aetiology is usually direct or indirect trauma related to sports, seizures, electric shock or electroconvulsive therapy. We present the first reported case of atraumatic bilateral acute anterior shoulder dislocations with associated Hill-Sachs lesions in a young, fit and well patient with no comorbidities. MRI illustrated the Hill-Sachs lesions with superior labral tear from anterior to posterior, and confirmed the acute nature of the injury by demonstrating the bone marrow oedema. The patient was treated surgically with arthroscopic anterior stabilisation. At 6 months following surgery, the patient has a pain free full range of movement of both shoulders with no further dislocations and has returned to work.


Assuntos
Medula Óssea/patologia , Edema/complicações , Úmero/patologia , Luxação do Ombro/etiologia , Doença Aguda , Artroscopia , Edema/diagnóstico , Edema/cirurgia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Luxação do Ombro/diagnóstico , Luxação do Ombro/cirurgia
9.
BMJ Case Rep ; 20142014 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-24827648

RESUMO

Achilles tendon ruptures tend to occur more commonly in healthy men between the ages of 30 and 50 years who have had no previous injury or problem reported in the affected leg. The injury is usually due to sudden forced plantar flexion of the foot, unexpected dorsiflexion of the foot and violent dorsiflexion of a plantar flexed foot, all of which occur during high impact activities. We present the first reported case of interactive activity with Nintendo Wii games that have resulted in Achilles tendon rupture in a 46-year-old man. There have been no previous reports of Achilles tendon rupture with Nintendo Wii usage; it is a relatively uncommon mode of injury and is rare in terms of epidemiology of motion sensing video game injuries.


Assuntos
Tendão do Calcâneo/lesões , , Perna (Membro) , Ruptura/etiologia , Traumatismos dos Tendões/etiologia , Jogos de Vídeo/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...