Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Sci Pollut Res Int ; 30(41): 93531-93545, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37507560

RESUMO

The growing concerns about water pollution have prompted researchers to explore new materials for remediating and purifying it. In recent years, there has been a focus on polysaccharides as eco-friendly polymers that exhibit high efficiency in removing chlorophenols from waste water. This study aims to develop a trifunctional polysaccharide structure using a biodegradable matrix. The chitosan/alginate-polyethyleneimine-phenyl-phosphonamidic acid (CHIT/ALG-PEIPPAA) matrix was employed for removing chlorophenols from water. The study carefully examined the impact of various physicochemical parameters such as pH, reaction time, chlorophenols concentration, temperature, and ionic strength to determine the optimal conditions for the adsorption process. Several techniques were used to confirm the morphology, physicochemical properties, structure, and functionalization of the polymer. Scanning electron microscopy (SEM) images revealed a heterogeneous morphology with agglomerates of different particle sizes, ranging from a few micrometers with irregular shapes. The FTIR spectrum and zeta potential characterization indicated the presence of hydrophilic groups and a highly positive charge (around 31.4 mV) on the surface of the CHIT/ALG-PEIPPAA adsorbent. The optimal pH for chlorophenols removal was found to be approximately 4.4. The kinetic data supported the pseudo-second-order kinetic model, which accurately described the adsorption behavior of both chlorophenol molecules. The fitting of the isotherm analysis revealed that the Langmuir model provided a better representation of the adsorption process. The maximum adsorption capacities for 4-chlorophenol and 2,4-chlorophenol were approximately 118 mg.g-1 and 249 mg.g-1, respectively. The calculated thermodynamic functions confirmed an exothermic and spontaneous adsorption process for chlorophenols, with ∆H values of -6.98 kJ.mol-1 and -2.74 kJ.mol-1 for 4-chlorophenol and 2,4-chlorophenol, respectively. The regeneration process of the CHIT/ALG-PEIPPAA adsorbent showed higher efficacy in the presence of hydrochloric acid (2.0 mol.L-1), resulting in up to 91% desorption of chlorophenols. The CHIT/ALG-PEIPPAA adsorbent demonstrated good reusability after regeneration, with only a slight decrease in extraction efficiency: 34.63% for 4-chlorophenol and 79.03% for 2,4-chlorophenol, under the same optimal conditions as the initial adsorption cycle.


Assuntos
Clorofenóis , Poluentes Químicos da Água , Poluentes Químicos da Água/análise , Clorofenóis/química , Termodinâmica , Fenol/análise , Alginatos/química , Adsorção , Cinética , Concentração de Íons de Hidrogênio
2.
Med Image Comput Comput Assist Interv ; 17(Pt 2): 659-66, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25485436

RESUMO

We present the idea of a user interface concept, which resolves the challenges involved in the control of angiographic C-arms for their constant repositioning during interventions by either the surgeons or the surgical staff. Our aim is to shift the paradigm of interventional image acquisition workflow from the traditional control device interfaces to 'desired-view' control. This allows the physicians to only communicate the desired outcome of imaging, based on simulated X-rays from pre-operative CT or CTA data, while the system takes care of computing the positioning of the imaging device relative to the patient's anatomy through inverse kinematics and CT to patient registration. Together with our clinical partners, we evaluate the new technique using 5 patient CTA and their corresponding intraoperative X-ray angiography datasets.


Assuntos
Angiografia/métodos , Aneurisma Aórtico/diagnóstico por imagem , Aumento da Imagem/métodos , Robótica/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Interface Usuário-Computador , Algoritmos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Robótica/instrumentação , Sensibilidade e Especificidade , Software , Cirurgia Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...