Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cornea ; 40(6): 755-763, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33630814

RESUMO

PURPOSE: To compare the reliability of microkeratome dissection with the anterior chamber pressurizer (ACP) system versus conventional pressurization for ultrathin Descemet-stripping automated endothelial keratoplasty (UT-DSAEK) graft preparation. METHODS: A retrospective review of a consecutive series of dissected donor corneas processed at Pavia Eye Bank for UT-DSAEK surgery was performed. Grafts were prepared through single-pass microkeratome dissection with artificial anterior chamber internal pressure regulation through either ACP or the conventional method using a water column with tube clamp. The target central graft thickness (CGT) was ≤100 µm. Cutting predictability was determined as the difference between the microkeratome head size and the thickness actually removed. Graft regularity was investigated as central-to-peripheral thickness increase, central-to-peripheral (CP) ratio, and graft thickness uniformity. Thickness was measured with anterior segment optical coherence tomography (horizontal and vertical meridians). RESULTS: Of the 265 UT-DSAEK grafts, ACP achieved the target "CGT ≤ 100 µm" in 87 of 120 (72.5%), whereas the conventional technique achieved the same in 85 of 145 (58.6%) (P = 0.018). ACP predictability was -3.9 µm (SD: 2.3), whereas predictability of the conventional technique was -54.6 µm (SD: 3.7) (P < 0.001). Thickness increased similarly (P = 0.212); CP ratio was better with ACP for only 2 mm diameter (P = 0.001); graft thickness uniformity was comparable (P > 0.05). CONCLUSIONS: Compared with conventional pressurization, ACP improved microkeratome-assisted preparation reliability of UT-DSAEK grafts, achieving CGT ≤ 100 µm with significantly higher frequency (P = 0.018) and predictability (P < 0.001). ACP improved CP ratio only at 2 mm (P = 0.001); for other graft thickness, the 2 methods proved equivalent.


Assuntos
Câmara Anterior/cirurgia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos , Coleta de Tecidos e Órgãos/métodos , Idoso , Idoso de 80 Anos ou mais , Lâmina Limitante Posterior/diagnóstico por imagem , Endotélio Corneano/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Estudos Retrospectivos , Obtenção de Tecidos e Órgãos , Tomografia de Coerência Óptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...