Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Int J Mol Sci ; 22(10)2021 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-34068980

RESUMO

Ultraviolet (UV) exposure has been linked to skin damage and carcinogenesis, but recently UVB has been proposed as a therapeutic approach for cancer. Herein, we investigated the cellular and molecular effects of UVB in immortal and tumorigenic HPV positive and negative cells. Cells were irradiated with 220.5 to 1102.5 J/m2 of UVB and cell proliferation was evaluated by crystal violet, while cell cycle arrest and apoptosis analysis were performed through flow cytometry. UVB effect on cells was recorded at 661.5 J/m2 and it was exacerbated at 1102.5 J/m2. All cell lines were affected by proliferation inhibition, cell cycle ablation and apoptosis induction, with different degrees depending on tumorigenesis level or HPV type. Analysis of the well-known UV-responsive p53, E2F1 and microtubules system proteins was performed in SiHa cells in response to UVB through Western-blotting assays. E2F1 and the Microtubule-associated protein 2 (MAP2) expression decrease correlated with cellular processes alteration while p53 and Microtubule-associated Protein 1S (MAP1S) expression switch was observed since 882 J/m2, suggesting they were required under more severe cellular damage. However, expression transition of α-Tubulin3C and ß-Tubulin was abruptly noticed until 1102.5 J/m2 and particularly, γ-Tubulin protein expression remained without alteration. This study provides insights into the effect of UVB in cervical cancer cell lines.


Assuntos
Fator de Transcrição E2F1/metabolismo , Regulação Neoplásica da Expressão Gênica/efeitos da radiação , Microtúbulos/efeitos da radiação , Proteína Supressora de Tumor p53/metabolismo , Raios Ultravioleta , Neoplasias do Colo do Útero/patologia , Apoptose , Ciclo Celular , Proliferação de Células , Fator de Transcrição E2F1/genética , Feminino , Humanos , Células Tumorais Cultivadas , Proteína Supressora de Tumor p53/genética , Neoplasias do Colo do Útero/genética , Neoplasias do Colo do Útero/metabolismo , Neoplasias do Colo do Útero/radioterapia
2.
Rev. med. nucl. Alasbimn j ; 11(42)oct. 2008. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-504084

RESUMO

Mediante métodos Monte Carlo se calcularon las dosis en los órganos internos de una mujer, con tres meses de embarazo, debidas al radioiodo captado por su tiroides, así como a 1 metro de la glándula. Se utilizó un modelo tridimensional del cuerpo de la mujer y mediante Monte Carlo, los fotones de radioiodo se transportaron isotrópicamente desde la tiroides hacia todo el cuerpo y se calculó la dosis absorbida por sus órganos internos. También se determinó el Kerma en aire (K) y la dosis equivalente ambiental (H*(10)) a 1 m de la glándula. Se determinaron dos factores de actividad a dosis, también llamados Factores Gamma, que permiten estimar la dosis que la paciente produce a personas a su alrededor. De la radiación gamma que emite el 131I en la tiroides se encontró que el timo recibe la mayor dosis mientras que el útero es el órgano que menor dosis recibe. Los factores gamma determinados fueron: ΓKAire = 52.06 μGy-m2-h-1-GBq-1, y ΓH*(10) = 67.72 μSv-m2-h-1-GBq-1. La distribución de la dosis absorbida por los órganos internos se atribuye a la distancia relativa entre la tiroides y los otros órganos, al blindaje inter-órganos, su tamaño y a su composición elemental. Los factores ΓKAire y ΓH*(10) permiten estimar la exposición que la paciente produce sobre el personal a su alrededor. Con esto, el médico nuclear, el físico médico o el responsable de la seguridad radiológica en el hospital pueden dar indicaciones mas precisas sobre el comportamiento de las personas en torno al paciente.


Assuntos
Humanos , Feminino , Gravidez , Método de Monte Carlo , Radioisótopos do Iodo/administração & dosagem , Radioisótopos do Iodo/farmacocinética , Radiometria/métodos , Simulação por Computador , Distribuição Tecidual , Doses de Radiação , Glândula Tireoide/efeitos da radiação , Glândulas Mamárias Humanas/efeitos da radiação , Modelos Biológicos , Primeiro Trimestre da Gravidez , Raios gama , Transferência de Energia , Útero/efeitos da radiação
3.
Salud Publica Mex ; 48(3): 212-9, 2006.
Artigo em Espanhol | MEDLINE | ID: mdl-16813129

RESUMO

OBJECTIVE: To determine the lead concentration in the blood of children and nursing or pregnant women from San Ignacio, Fresnillo, in Zacatecas, Mexico as well as in soil, plants, ash and lead-glazed pottery, in order to determine exposure due to a metal-recycling facility. MATERIAL AND METHODS: The study was carried out from December 2004 to April 2005. Lead in blood was measured with anodic stripping voltammetry, while dispersive energy X-ray fluorescence was used in the other matrices. RESULTS: Based upon the criteria outlined in the Official Mexican Standards, 90% of the children was identified as category 1, 5% as category II and another 5% as category III. The soil in the land near the facility contained from 73 to 84,238 microg/g, with an average of 4940 microg/g. Larger lead concentrations were found on sites located closer to the facility. San Ignacio's soil contained, on average, 109 microg/g. High lead levels were found in glazed pottery and the concentration in agricultural crops was greater than 300 microg/g. CONCLUSIONS: Although the majority of children in San Ignacio have blood lead concentrations considered to be acceptable according to the Official Mexican Standards, several studies indicate that deleterious effects on children's health exist even at low concentrations. The land around the metal recycling facility is contaminated with lead, and to that extent, the crops that are produced there, once ingested, are a source of contamination, which is compounded by the use of glazed pottery.


Assuntos
Poluição Ambiental/análise , Chumbo/análise , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Chumbo/sangue , Masculino , México , Gravidez , Fatores de Risco
4.
Salud pública Méx ; 48(3): 212-219, mayo-jun. 2006. tab
Artigo em Espanhol | LILACS | ID: lil-430077

RESUMO

OBJETIVO: Determinar la concentración de plomo en la sangre de niños y mujeres, en periodo de lactancia o embarazadas, de la comunidad de San Ignacio, Fresnillo, en Zacatecas, así como en matrices de suelo, plantas, ceniza y barro vidriado, para determinar la exposición que genera una empresa recicladora de metales. MATERIAL Y MÉTODOS: El estudio se realizó de diciembre de 2004 al mes de abril de 2005. El Pb en sangre se midió por voltamperometría de redisolución anódica, mientras que se utilizó energía dispersa de fluorescencia por rayos X para las otras matrices. RESULTADOS: Con base en los criterios de la Norma Oficial Mexicana (NOM) se encontró que 90 por ciento de los menores está en la categoría I, 5 por ciento se encuentra en la categoría II y el otro 5 por ciento se ubica en la categoría III. El suelo de los terrenos aledaños a la recicladora tiene en promedio 4 940 µg/g, en un intervalo de 73 a 84 238 µg/g. Las mayores concentraciones se localizan en los puntos más cercanos a la empresa. El suelo de San Ignacio tiene en promedio 109 µg/g. Se encontraron valores altos en el barro vidriado y la concentración del Pb en las plantas es superior a los 300 µg/g. CONCLUSIONES: A pesar de que la mayoría de los niños analizados presenta niveles de plomo en sangre que la Norma Mexicana señala como aceptables, varios estudios indican que existen efectos nocivos aun a concentraciones bajas. Los terrenos aledaños a la empresa están contaminados, y en esa medida los alimentos que ahí se producen, al ser consumidos, son una fuente de contaminación, que se agudiza con el uso de barro vidriado.


Assuntos
Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Gravidez , Poluição Ambiental/análise , Chumbo/análise , Chumbo/sangue , México , Fatores de Risco
5.
Rev. med. nucl. Alasbimn j ; 6(22)oct. 2003. ilus, tab, graf
Artigo em Inglês | LILACS | ID: lil-385324

RESUMO

Se diseñó una fuente de neutrones para la Sinovectomía por Captura de Neutrones en Boro. La fuente utiliza una fuente isotópica de 239PuBe que se inserta en el centro de contenedor cilindrico con un arreglo heterogéneo de dos moderadores. Los moderadores estudiados son agua ligera/agua pesada, grafito/agua pesada, lucita/agua pesada y polietileno/agua pesada. La fluencia total y la de los neutrones térmicos producidas se emplearon para seleccionar el mejor embalaje. Así, el espectro que produce una fuente de 239PuBe dentro del moderador con polietileno/agua pesada se utilizó como término fuente para calcular los espectros de neutrones dentro de un modelo de rodilla. La composición elemental utilizada para modelar el saco y el líquido sinovial fue la del agua, la del tejido sanguíneo y la de este último con dos concentraciones de boro. Encontramos que cuando la composición elemental del saco sinovial se asume igual a la del tejido sanguíneo con 0.278 por ciento en peso de boro el kerma debido a los neutrones es 7351 veces mayor al que se obtiene cuando la composición del saco sinovial es la del agua.


Assuntos
Bolsa Sinovial , Terapia por Captura de Nêutron de Boro , Bolsa Sinovial/cirurgia , Boro , Modelos Teóricos
6.
Appl Radiat Isot ; 57(2): 167-70, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12150274

RESUMO

Neutron and gamma-ray spectra of 239PuBe and 241AmBe were measured and their dosimetric features were calculated. Neutron spectra were measured using a multisphere neutron spectrometer with a 6LiI(Eu) scintillator. The 239PuBe neutron spectrum was measured in an open environment, while the 241AmBe neutron spectrum was measured in a closed environment. Gamma-ray spectra were measured using a NaI(Tl) scintillator using the same experimental conditions for both sources. The effect of measuring conditions for the 241AmBe neutron spectrum indicates the presence of epithermal and thermal neutrons. The low-resolution neutron spectra obtained with the multisphere spectrometer allows one to calculate the dosimetric features of neutron sources. At 100 cm both sources produce approximately the same count rate as that of the 4.4 MeV gamma-ray per unit of alpha emitter activity.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...