Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Circ Cardiovasc Interv ; 12(7): e007258, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31296082

RESUMO

BACKGROUND: Open surgical closure and small-bore suture-based preclosure devices have limitations when used for transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or percutaneous thoracic endovascular aortic aneurysm repair. The MANTA vascular closure device is a novel collagen-based technology designed to close large bore arteriotomies created by devices with an outer diameter ranging from 12F to 25F. In this study, we determined the safety and effectiveness of the MANTA vascular closure device. METHODS AND RESULTS: A prospective, single arm, multicenter investigation in patients undergoing transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or thoracic endovascular aortic aneurysm repair at 20 sites in North America. The primary outcome was time to hemostasis. The primary safety outcomes were accessed site-related vascular injury or bleeding complications. A total of 341 patients, 78 roll-in, and 263 in the primary analysis cohort, were entered in the study between November 2016 and September 2017. For the primary analysis cohort, transcatheter aortic valve replacement was performed in 210 (79.8%), and percutaneous endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair was performed in 53 (20.2%). The 14F MANTA was used in 42 cases (16%), and the 18F was used in 221 cases(84%). The mean effective sheath outer diameter was 22F (7.3 mm). The mean time to hemostasis was 65±157 seconds with a median time to hemostasis of 24 seconds. Technical success was achieved in 257 (97.7%) patients, and a single device was deployed in 262 (99.6%) of cases. Valve Academic Research Consortium-2 major vascular complications occurred in 11 (4.2%) cases: 4 received a covered stent (1.5%), 3 had access site bleeding (1.1%), 2 underwent surgical repair (0.8%), and 2 underwent balloon inflation (0.8%). CONCLUSIONS: In a selected population, this study demonstrated that the MANTA percutaneous vascular closure device can safely and effectively close large bore arteriotomies created by current generation transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, and thoracic endovascular aortic aneurysm repair devices. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02908880.


Assuntos
Cateterismo Periférico , Procedimentos Endovasculares , Hemorragia/prevenção & controle , Técnicas Hemostáticas/instrumentação , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Cateterismo Periférico/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Desenho de Equipamento , Feminino , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , América do Norte , Estudos Prospectivos , Punções , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Dispositivos de Oclusão Vascular/efeitos adversos
2.
JACC Cardiovasc Interv ; 10(6): 613-619, 2017 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-28335899

RESUMO

OBJECTIVES: The authors sought to study the safety and efficacy of the MANTA Vascular Closure Device (VCD), a novel collagen-based technology dedicated to closure of large-bore arteriotomies. BACKGROUND: Novel transfemoral therapeutic interventions requiring large-bore catheters have become valid minimally invasive options but have inherent access management challenges. To date, no dedicated vascular closure devices exist for large arteriotomies. METHODS: A prospective, single-arm clinical investigation enrolling patients who underwent elective percutaneous interventions with large-bore catheters and planned percutaneous arteriotomy closure in 3 European institutions. RESULTS: A total of 50 patients with a mean age of 79.5 ± 8.3 years underwent high-risk percutaneous coronary intervention, balloon aortic valvuloplasty, or transcatheter aortic valve replacement with large-bore catheters sized 12-F to 19-F. MANTA closure was performed by 9 different operators. The 14-F MANTA VCD was deployed in one-third of the overall cohort (16 of 50, 32%), and the 18-F MANTA VCD in the remainder. The MANTA VCD was deployed successfully in all patients. The mean time to hemostasis was 2 min, 23 s. One patient had a major vascular and major bleeding complication with prolonged femoral bleeding that was successfully treated with a covered stent and eventual surgical repair. There were no other access site-related complications. CONCLUSIONS: This first multicenter experience demonstrates rapid and reliable hemostasis and low complication rates with the use of the plug-based MANTA VCD for large-bore arteriotomy closure.


Assuntos
Cateterismo Periférico/instrumentação , Artéria Femoral , Hemorragia/prevenção & controle , Técnicas Hemostáticas/instrumentação , Dispositivos de Acesso Vascular , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Cateterismo Periférico/efeitos adversos , Angiografia por Tomografia Computadorizada , Desenho de Equipamento , Europa (Continente) , Feminino , Artéria Femoral/diagnóstico por imagem , Hemorragia/etiologia , Humanos , Masculino , Estudos Prospectivos , Punções , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...