Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Angiología ; 69(3): 137-146, mayo.-jun. 2017. graf, ilus
Artigo em Espanhol | IBECS | ID: ibc-164475

RESUMO

Introducción: Debido a las características electromagnéticas únicas del microhilo amorfo magnetoelástico, los cambios en la presión de un fluido provocarán una variación de la tensión mecánica sobre el sensor, lo que supondrá una variación de su imanación que será detectable de forma inalámbrica. Utilizando esta tecnología, se podrá desarrollar un sistema inalámbrico para el seguimiento de procedimientos en cirugía vascular. Métodos: El sensor diseñado consiste en un anillo de microhilo magnetoelástico que se integró en un modelo in vitro con flujo pulsátil. Se simularon distintos grados de estenosis en distintas localizaciones, tanto en arteria bovina como en un segmento de PTFE. Se realizó el análisis de Fourier de las señales registradas, y se emplearon el test de correlación de Pearson y curvas COR para el análisis de la información. Resultados: Se obtuvo un índice de correlación de Pearson de 0,945 (p < 0,001) entre la presión invasiva del fluido y la potencia de la señal emitida por el microhilo magnetoelástico en arteria bovina. Se obtuvieron unas excelentes curvas COR, tanto en el caso de las estenosis preanastomóticas (AUC 0,98; IC 95%: 0,97-1) y anastomóticas (AUC 0,93; IC 95%: 0,86-0,99), como en el caso de las estenosis distales (AUC 0,88; IC 95%: 0,79-0,98), comparadas con un grupo control. Conclusiones: El microhilo magnetoelástico es capaz de detectar, localizar y cuantificar el grado de estenosis en arteria bovina, así como en una anastomosis latero-terminal, con una elevada potencia estadística. Por primera vez se ha desarrollado un sensor inalámbrico in vitro para el seguimiento postoperatorio de los procedimientos en cirugía vascular (AU)


Introduction: Due to the unique electromagnetic characteristics of the magnetoelastic microwire, the changes in the pressure of a fluid will lead to changes in the mechanical pressure on the sensor, which will then cause a variation of its magnetisation which will be detectable wirelessly. Thus, a wireless system can be developed for following-up vascular surgery procedures. Methods: The sensor consists of a magnetoelastic microwire ring which was integrated into an in vitro model with pulsatile flow. Different degrees of stenosis were simulated in different locations in bovine artery, as well as in a polytetrafluoroethylene anastomosis. A Fourier analysis of the registered signals was performed, with a statistical analysis using Pearson test and ROC curves. Results: A Pearson index of .945 (P < .001) was obtained between the invasive pressure of the fluid and the power of the signal transmitted by the sensor in bovine artery. The sensor obtained very good ROC curves in the analysis of the registered the signals, in the case of pre-anastomotic stenosis (AUC .98; 95% CI: .97-1), anastomosis (AUC .93; 95% CI: .86-.99), as well as distal (AUC .88; 95% CI: .79-.98), compared to the control group. Conclusions: The magnetoelastic microwire has shown that it is capable of detecting, locating and quantifying the degree of stenosis in bovine artery, as well as in a latero- terminal anastomosis, with a high statistical power. For the first time, a wireless in vitro sensor has been developed for the post-operative follow-up of vascular surgery procedures (AU)


Assuntos
Humanos , Procedimentos Cirúrgicos Vasculares/estatística & dados numéricos , Doença Arterial Periférica/diagnóstico , Telemetria/instrumentação , Técnicas In Vitro/métodos , Monitorização Ambulatorial/instrumentação , Seguimentos , Tecnologia sem Fio , Cuidados Pós-Operatórios/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...