Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Av. odontoestomatol ; 24(5): 323-332, sept.-oct. 2008. ilus, tab
Artigo em Es | IBECS | ID: ibc-68082

RESUMO

El presente trabajo evaluó el movimiento de los dientes artificiales en prótesis totales maxilares, sometidas a diversas presiones durante el prensado y el efecto de este en relación al material usado en la inclusión. Treinta y seis réplicas de prótesis totales previamente confeccionadas, fueran divididas en seis grupos: Los grupos G1,G2 y G3 fueron incluidos con yeso tipo III, a una presión de 800, 1.000 y 1.250 kgf respectivamente y los grupos S1, S2 y S3 fueron incluidos con una barrera de silicona y yeso, a una presión de 800, 1.000 y 1.250kgf, respectivamente. Las prótesis fueron medidas en puntos demarcados previamente en los segundos molares, premolares e incisivo central con el programa de computación gráfica (AutoCad 2000), después de cada etapa: encerado, polimerización y emuflado. La comparación entre estas dos fases permitió observar que: en los grupos (G1 y S1) donde se utilizó la menor presión (800 kgf) ocurrieron las mayores alteraciones en el posicionamiento de los dientes artificiales y que el grupo que mostró menores alteraciones fue cuando se utilizó 1.250 kgf de presión y la inclusión fue con yeso (AU)


The present study evaluated artificial teeth movement in complete dentures, submitted to different flasking loading and the effect of these loading pressures on the material used in the flasking procedure. Thirty-six dentures were fabricated and equally divided into six groups: Groups G1, G2 and G3 were processed with type III gypsum and 800, 1000 and 1250 kgf loading pressures, respectively, and groups S1, S2 and S3 were processed with silicone barrier and 800, 1000 and 1250 kgf loading pressures, respectively. In order to evaluate the artificial teeth movement, measurements were performed from previously determined points down in the second molars tips and in the second pre-molars cusps and in the central incisor. Those points were scanned (Scan Jet 6100C - Hewlett Packard) and then the measurements were performed and analyzed through the use of the AutoCad 2000 software, during the wax and the post-polymerization phases. The comparison between these two phases allowed the following observations: in groups (G1 and S1) where less loading pressure was used (800 kgf), the movements in the artificial teeth positions were the highest, and the group that presented the lowest changes was the one processed with type III gypsum and 1250 kgf loading pressure (AU)


Assuntos
Prótese Total/tendências , Prótese Total , Técnicas de Movimentação Dentária/métodos , Técnicas de Movimentação Dentária/tendências , Resinas Acrílicas/farmacologia , Resinas Acrílicas/uso terapêutico , Prótese Total Superior/classificação , Prótese Total Superior/tendências , Prótese Total Superior , Prótese Total/classificação , Próteses e Implantes/tendências , Próteses e Implantes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...